Skip to main content
Erschienen in: Neuroradiology 9/2016

23.06.2016

Reliability of cerebral vein volume quantification based on susceptibility-weighted imaging

verfasst von: K. Egger, A. K. Dempfle, S. Yang, R. Schwarzwald, A. Harloff, H. Urbach

Erschienen in: Neuroradiology | Ausgabe 9/2016

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Susceptibility-weighted imaging (SWI) visualizes even small cerebral veins and might, therefore, be valuable in monitoring neurological diseases affecting cerebral veins. Since it is generally difficult to evaluate individual results of quantitative MRI measurements, an automatic approach would be highly appreciated to assist the diagnostic process. The aim of this study was to evaluate the rescan and reanalysis reliability using an automatic venous volumetric approach based on SWI in healthy controls.

Methods

SWI was performed in ten healthy controls undergoing MRI examinations using a 32-channel head coil at 3 T five times on five different days. To test for rescan and reanalysis variability, the deep cerebral vein volume was quantified using ANTs and SPM8.

Results

Total volumes of cerebral deep veins measured during five MRI scans in ten individuals (n = 50 scans) showed intra-individual volume changes ranging from 0.07 to 1.03 ml (mean variability = 10.2 %). Automatic reanalyses revealed exactly the same results in all scans.

Conclusion

Automatic SWI-based cerebral vein volumetry shows acceptable rescan—and excellent reanalyses—reliability in healthy volunteers. Therefore, this approach might be beneficial in intra-individual follow-up studies of neurological diseases affecting the cerebral venous system.
Literatur
1.
Zurück zum Zitat Ogawa S, Lee TM, Kay AR et al (1990) Brain magnetic resonance imaging with contrast dependent on blood oxygenation. Proc Natl Acad Sci U S A 87(24):9868–9872CrossRefPubMedPubMedCentral Ogawa S, Lee TM, Kay AR et al (1990) Brain magnetic resonance imaging with contrast dependent on blood oxygenation. Proc Natl Acad Sci U S A 87(24):9868–9872CrossRefPubMedPubMedCentral
2.
Zurück zum Zitat Reichenbach JR, Barth M, Haacke EM et al (2000) High-resolution MR venography at 3.0 Tesla. J Comput Assist Tomogr 24(6):949–957CrossRefPubMed Reichenbach JR, Barth M, Haacke EM et al (2000) High-resolution MR venography at 3.0 Tesla. J Comput Assist Tomogr 24(6):949–957CrossRefPubMed
9.
Zurück zum Zitat Luo S, Yang L, Wang L (2014) Comparison of susceptibility-weighted and perfusion-weighted magnetic resonance imaging in the detection of penumbra in acute ischemic stroke. J Neuroradiol. doi:10.1016/j.neurad.2014.07.002 Luo S, Yang L, Wang L (2014) Comparison of susceptibility-weighted and perfusion-weighted magnetic resonance imaging in the detection of penumbra in acute ischemic stroke. J Neuroradiol. doi:10.​1016/​j.​neurad.​2014.​07.​002
15.
Zurück zum Zitat Chang K, Barnes S, Haacke EM et al (2014) Imaging the effects of oxygen saturation changes in voluntary apnea and hyperventilation on susceptibility-weighted imaging. AJNR Am J Neuroradiol 35(6):1091–1095. doi:10.3174/ajnr.A3818 CrossRefPubMed Chang K, Barnes S, Haacke EM et al (2014) Imaging the effects of oxygen saturation changes in voluntary apnea and hyperventilation on susceptibility-weighted imaging. AJNR Am J Neuroradiol 35(6):1091–1095. doi:10.​3174/​ajnr.​A3818 CrossRefPubMed
Metadaten
Titel
Reliability of cerebral vein volume quantification based on susceptibility-weighted imaging
verfasst von
K. Egger
A. K. Dempfle
S. Yang
R. Schwarzwald
A. Harloff
H. Urbach
Publikationsdatum
23.06.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Neuroradiology / Ausgabe 9/2016
Print ISSN: 0028-3940
Elektronische ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-016-1712-z

Weitere Artikel der Ausgabe 9/2016

Neuroradiology 9/2016 Zur Ausgabe

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.