Skip to main content
Erschienen in: Skeletal Radiology 3/2012

01.03.2012 | Scientific Article

Reliability of the assessment of lower limb torsion using computed tomography: analysis of five different techniques

verfasst von: Emmanouil Liodakis, Iosifina Doxastaki, Kongfai Chu, Christian Krettek, Ralph Gaulke, Musa Citak, Mohamed Kenawey

Erschienen in: Skeletal Radiology | Ausgabe 3/2012

Einloggen, um Zugang zu erhalten

Abstract

Objective

Various methods have been described to define the femoral neck and distal tibial axes based on a single CT image. The most popular are the Hernandez and Weiner methods for defining the femoral neck axis and the Jend, Ulm, and bimalleolar methods for defining the distal tibial axis. The purpose of this study was to calculate the intra- and interobserver reliability of the above methods and to determine intermethod differences.

Methods

Three physicians separately measured the rotational profile of 44 patients using CT examinations on two different occasions. The average age of patients was 36.3 ± 14.4 years, and there were 25 male and 19 female patients. After completing the first two sessions of measurements, one observer chose certain cuts at the levels of the femoral neck, femoral condylar area, tibial plateau, and distal tibia. The three physicians then repeated all measurements using these CT cuts.

Results

The greatest interclass correlation coefficients were achieved with the Hernandez (0.99 intra- and 0.93 interobserver correlations) and bimalleolar methods (0.99 intra- and 0.92 interobserver correlations) for measuring the femoral neck and distal tibia axes, respectively. A statistically significant decrease in the interobserver median absolute differences could be achieved through the use of predefined CT scans only for measurements of the femoral condylar axis and the distal tibial axis using the Ulm method. The bimalleolar axis method underestimated the tibial torsion angle by an average of 4.8° and 13° compared to the Ulm and Jend techniques, respectively.

Conclusions

The methods with the greatest inter- and intraobserver reliabilities were the Hernandez and bimalleolar methods for measuring femoral anteversion and tibial torsion, respectively. The high intermethod differences make it difficult to compare measurements made with different methods.
Literatur
1.
Zurück zum Zitat Paley D, Herzenberg JE, Tetsworth K, McKie J, Bhave A. Deformity planning for frontal and sagittal plane corrective osteotomies. Orthop Clin North Am. 1994;25:425–65.PubMed Paley D, Herzenberg JE, Tetsworth K, McKie J, Bhave A. Deformity planning for frontal and sagittal plane corrective osteotomies. Orthop Clin North Am. 1994;25:425–65.PubMed
2.
Zurück zum Zitat Paley D, Tetsworth K. Mechanical axis deviation of the lower limbs. Preoperative planning of multiapical frontal plane angular and bowing deformities of the femur and tibia. Clin Orthop Relat Res 1992:65–71. Paley D, Tetsworth K. Mechanical axis deviation of the lower limbs. Preoperative planning of multiapical frontal plane angular and bowing deformities of the femur and tibia. Clin Orthop Relat Res 1992:65–71.
3.
Zurück zum Zitat Paley D, Tetsworth K. Mechanical axis deviation of the lower limbs. Preoperative planning of uniapical angular deformities of the tibia or femur. Clin Orthop Relat Res 1992:48–64. Paley D, Tetsworth K. Mechanical axis deviation of the lower limbs. Preoperative planning of uniapical angular deformities of the tibia or femur. Clin Orthop Relat Res 1992:48–64.
4.
Zurück zum Zitat Feldman DS, Henderson ER, Levine HB, et al. Interobserver and intraobserver reliability in lower-limb deformity correction measurements. J Pediatr Orthop. 2007;27:204–8.PubMedCrossRef Feldman DS, Henderson ER, Levine HB, et al. Interobserver and intraobserver reliability in lower-limb deformity correction measurements. J Pediatr Orthop. 2007;27:204–8.PubMedCrossRef
5.
Zurück zum Zitat Noyes FR, Goebel SX, West J. Opening wedge tibial osteotomy: the 3-triangle method to correct axial alignment and tibial slope. Am J Sports Med. 2005;33:378–87.PubMedCrossRef Noyes FR, Goebel SX, West J. Opening wedge tibial osteotomy: the 3-triangle method to correct axial alignment and tibial slope. Am J Sports Med. 2005;33:378–87.PubMedCrossRef
6.
Zurück zum Zitat Jaarsma RL, Bruggeman AW, Pakvis DF, et al. Computed tomography determined femoral torsion is not accurate. Arch Orthop Trauma Surg. 2004;124:552–4.PubMedCrossRef Jaarsma RL, Bruggeman AW, Pakvis DF, et al. Computed tomography determined femoral torsion is not accurate. Arch Orthop Trauma Surg. 2004;124:552–4.PubMedCrossRef
7.
Zurück zum Zitat Murphy SB, Simon SR, Kijewski PK, Wilkinson RH, Griscom NT. Femoral anteversion. J Bone Joint Surg Am. 1987;69:1169–76.PubMed Murphy SB, Simon SR, Kijewski PK, Wilkinson RH, Griscom NT. Femoral anteversion. J Bone Joint Surg Am. 1987;69:1169–76.PubMed
8.
Zurück zum Zitat Sugano N, Noble PC, Kamaric E. A comparison of alternative methods of measuring femoral anteversion. J Comput Assist Tomogr. 1998;22:610–4.PubMedCrossRef Sugano N, Noble PC, Kamaric E. A comparison of alternative methods of measuring femoral anteversion. J Comput Assist Tomogr. 1998;22:610–4.PubMedCrossRef
9.
Zurück zum Zitat Kuo TY, Skedros JG, Bloebaum RD. Measurement of femoral anteversion by biplane radiography and computed tomography imaging: comparison with an anatomic reference. Invest Radiol. 2003;38:221–9.PubMed Kuo TY, Skedros JG, Bloebaum RD. Measurement of femoral anteversion by biplane radiography and computed tomography imaging: comparison with an anatomic reference. Invest Radiol. 2003;38:221–9.PubMed
10.
Zurück zum Zitat Bouchard R, Meeder PJ, Krug F, Libicher M. Evaluation of tibial torsion—comparison of clinical methods and computed tomography. Rofo. 2004;176:1278–84.PubMedCrossRef Bouchard R, Meeder PJ, Krug F, Libicher M. Evaluation of tibial torsion—comparison of clinical methods and computed tomography. Rofo. 2004;176:1278–84.PubMedCrossRef
11.
Zurück zum Zitat Hernandez RJ, Tachdjian MO, Poznanski AK, Dias LS. CT determination of femoral torsion. AJR Am J Roentgenol. 1981;137:97–101.PubMed Hernandez RJ, Tachdjian MO, Poznanski AK, Dias LS. CT determination of femoral torsion. AJR Am J Roentgenol. 1981;137:97–101.PubMed
12.
Zurück zum Zitat Weiner DS, Cook AJ, Hoyt Jr WA, Oravec CE. Computed tomography in the measurement of femoral anteversion. Orthopedics. 1978;1:299–306.PubMed Weiner DS, Cook AJ, Hoyt Jr WA, Oravec CE. Computed tomography in the measurement of femoral anteversion. Orthopedics. 1978;1:299–306.PubMed
13.
Zurück zum Zitat Jend HH, Heller M, Dallek M, Schoettle H. Measurement of tibial torsion by computer tomography. Acta Radiol Diagn (Stockh). 1981;22:271–6. Jend HH, Heller M, Dallek M, Schoettle H. Measurement of tibial torsion by computer tomography. Acta Radiol Diagn (Stockh). 1981;22:271–6.
14.
Zurück zum Zitat Jend HH, Heller M, Schontag H, Schoettle H. A computer tomographic method for the determination of tibial torsion (author’s transl). Rofo. 1980;133:22–5.PubMedCrossRef Jend HH, Heller M, Schontag H, Schoettle H. A computer tomographic method for the determination of tibial torsion (author’s transl). Rofo. 1980;133:22–5.PubMedCrossRef
15.
Zurück zum Zitat Reikeras O, Hoiseth A. Torsion of the leg determined by computed tomography. Acta Orthop Scand. 1989;60:330–3.PubMedCrossRef Reikeras O, Hoiseth A. Torsion of the leg determined by computed tomography. Acta Orthop Scand. 1989;60:330–3.PubMedCrossRef
16.
Zurück zum Zitat Yagi T, Sasaki T. Tibial torsion in patients with medial-type osteoarthritic knee. Clin Orthop Relat Res. 1986:177–182. Yagi T, Sasaki T. Tibial torsion in patients with medial-type osteoarthritic knee. Clin Orthop Relat Res. 1986:177–182.
17.
Zurück zum Zitat Goutallier D, Van Driessche S, Manicom O, et al. Influence of lower-limb torsion on long-term outcomes of tibial valgus osteotomy for medial compartment knee osteoarthritis. J Bone Joint Surg Am. 2006;88:2439–47.PubMedCrossRef Goutallier D, Van Driessche S, Manicom O, et al. Influence of lower-limb torsion on long-term outcomes of tibial valgus osteotomy for medial compartment knee osteoarthritis. J Bone Joint Surg Am. 2006;88:2439–47.PubMedCrossRef
18.
Zurück zum Zitat Waidelich HA, Strecker W, Schneider E. Computed tomographic torsion-angle and length measurement of the lower extremity. The methods, normal values and radiation load. Rofo. 1992;157:245–51.PubMedCrossRef Waidelich HA, Strecker W, Schneider E. Computed tomographic torsion-angle and length measurement of the lower extremity. The methods, normal values and radiation load. Rofo. 1992;157:245–51.PubMedCrossRef
19.
Zurück zum Zitat Fleiss J. The design and analysis of clinical experiments. New York: John Wiley; 1986. Fleiss J. The design and analysis of clinical experiments. New York: John Wiley; 1986.
20.
Zurück zum Zitat Strecker W, Keppler P, Gebhard F, Kinzl L. Length and torsion of the lower limb. J Bone Joint Surg Br. 1997;79:1019–23.PubMedCrossRef Strecker W, Keppler P, Gebhard F, Kinzl L. Length and torsion of the lower limb. J Bone Joint Surg Br. 1997;79:1019–23.PubMedCrossRef
21.
Zurück zum Zitat Jaarsma RL, Pakvis DF, Verdonschot N, Biert J, van Kampen A. Rotational malalignment after intramedullary nailing of femoral fractures. J Orthop Trauma. 2004;18:403–9.PubMedCrossRef Jaarsma RL, Pakvis DF, Verdonschot N, Biert J, van Kampen A. Rotational malalignment after intramedullary nailing of femoral fractures. J Orthop Trauma. 2004;18:403–9.PubMedCrossRef
22.
Zurück zum Zitat Puloski S, Romano C, Buckley R, Powell J. Rotational malalignment of the tibia following reamed intramedullary nail fixation. J Orthop Trauma. 2004;18:397–402.PubMedCrossRef Puloski S, Romano C, Buckley R, Powell J. Rotational malalignment of the tibia following reamed intramedullary nail fixation. J Orthop Trauma. 2004;18:397–402.PubMedCrossRef
23.
Zurück zum Zitat Jaarsma RL, Ongkiehong BF, Gruneberg C, et al. Compensation for rotational malalignment after intramedullary nailing for femoral shaft fractures. An analysis by plantar pressure measurements during gait. Injury. 2004;35:1270–8.PubMedCrossRef Jaarsma RL, Ongkiehong BF, Gruneberg C, et al. Compensation for rotational malalignment after intramedullary nailing for femoral shaft fractures. An analysis by plantar pressure measurements during gait. Injury. 2004;35:1270–8.PubMedCrossRef
24.
Zurück zum Zitat Tornetta 3rd P, Ritz G, Kantor A. Femoral torsion after interlocked nailing of unstable femoral fractures. J Trauma. 1995;38:213–9.PubMedCrossRef Tornetta 3rd P, Ritz G, Kantor A. Femoral torsion after interlocked nailing of unstable femoral fractures. J Trauma. 1995;38:213–9.PubMedCrossRef
Metadaten
Titel
Reliability of the assessment of lower limb torsion using computed tomography: analysis of five different techniques
verfasst von
Emmanouil Liodakis
Iosifina Doxastaki
Kongfai Chu
Christian Krettek
Ralph Gaulke
Musa Citak
Mohamed Kenawey
Publikationsdatum
01.03.2012
Verlag
Springer-Verlag
Erschienen in
Skeletal Radiology / Ausgabe 3/2012
Print ISSN: 0364-2348
Elektronische ISSN: 1432-2161
DOI
https://doi.org/10.1007/s00256-011-1185-4

Weitere Artikel der Ausgabe 3/2012

Skeletal Radiology 3/2012 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.