Reproducibility of choroidal thickness measurements in subjects on 3 spectral domain optical coherence tomography machines

verfasst von: Chiang Ling Koay, Matthew Justin Quo, Visvaraja Subrayan

Erschienen in: International Ophthalmology | Ausgabe 3/2017

Einloggen, um Zugang zu erhalten

Abstract

The purpose of this study was to investigate the reproducibility of choroidal thickness measurements in normal subjects on 3 spectral domain optical coherence tomography instruments, namely: Zeiss Cirrus HD-OCT (Carl Zeiss Meditec Inc., Dublin, CA), Heidelberg Spectralis (Heidelberg Engineering, Heidelberg, Germany), and Optovue RTVue (Optovue Inc., Fremont, CA). This cross-sectional non-interventional study was performed in a single institution. Images were obtained in 47 eyes of 47 healthy volunteers which age ranged between 23 and 72 without ocular pathology. All subjects were imaged on the fovea using Cirrus HD 1-line raster, Spectralis enhanced depth imaging, and RTVue retina-cross. The choroid was measured subfoveally and at intervals of 500 µm from the fovea nasally and temporally up to 2500 µm. Paired t test, modified Bland–Altman plot, and Pearson’s correlation were used to compare the results. There is no significant difference between the systems for any measurement within 2500 µm either side of the fovea for most points. Inter-observer correlation was strong for RTVue, and moderate in both Cirrus and Spectralis.
Literatur
1.
Zurück zum Zitat Yanoff M, Duker JS (eds) (2008) Ophthalmology, 3rd edn. Mosby, Philadelphia Yanoff M, Duker JS (eds) (2008) Ophthalmology, 3rd edn. Mosby, Philadelphia
2.
Zurück zum Zitat Manjunath V, Taha M, Fujimoto JG et al (2010) Choroidal thickness in normal eyes measured using Cirrus HD optical coherence tomography. Am J Ophthalmol 150(3):325–329CrossRefPubMedPubMedCentral Manjunath V, Taha M, Fujimoto JG et al (2010) Choroidal thickness in normal eyes measured using Cirrus HD optical coherence tomography. Am J Ophthalmol 150(3):325–329CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Fujiwara T, Imamura Y, Margolis R et al (2009) Enhanced depth imaging optical coherence tomography of the choroid in highly myopic eyes. Am J Ophthalmol 148(3):445–450CrossRefPubMed Fujiwara T, Imamura Y, Margolis R et al (2009) Enhanced depth imaging optical coherence tomography of the choroid in highly myopic eyes. Am J Ophthalmol 148(3):445–450CrossRefPubMed
4.
Zurück zum Zitat Margolis R, Spaide RF (2009) A pilot study of enhanced depth imaging optical coherence tomography of the choroid in normal eyes. Am J Ophthalmol 147(5):811–815CrossRefPubMed Margolis R, Spaide RF (2009) A pilot study of enhanced depth imaging optical coherence tomography of the choroid in normal eyes. Am J Ophthalmol 147(5):811–815CrossRefPubMed
5.
Zurück zum Zitat Ramrattan RS, van der Schaft TL, Mooy CM et al (1994) Morphometric analysis of Bruch’s membrane, the choriocapillaris, and the choroid in aging. Invest Ophthalmol Vis Sci 35(6):2857–2864PubMed Ramrattan RS, van der Schaft TL, Mooy CM et al (1994) Morphometric analysis of Bruch’s membrane, the choriocapillaris, and the choroid in aging. Invest Ophthalmol Vis Sci 35(6):2857–2864PubMed
6.
Zurück zum Zitat Ho M, Liu DT, Chan VC et al (2013) Choroidal thickness measurement in myopic eyes by enhanced depth optical coherence tomography. Ophthalmology 120(9):1909–1914CrossRefPubMed Ho M, Liu DT, Chan VC et al (2013) Choroidal thickness measurement in myopic eyes by enhanced depth optical coherence tomography. Ophthalmology 120(9):1909–1914CrossRefPubMed
7.
8.
Zurück zum Zitat Ikuno Y, Kawaguchi K, Nouchi T et al (2010) Choroidal thickness in healthy Japanese subjects. Invest Ophthalmol Vis Sci 51(4):2173–2176CrossRefPubMed Ikuno Y, Kawaguchi K, Nouchi T et al (2010) Choroidal thickness in healthy Japanese subjects. Invest Ophthalmol Vis Sci 51(4):2173–2176CrossRefPubMed
9.
Zurück zum Zitat Regatieri CV, Branchini L, Carmody J et al (2012) Choroidal thickness in patients with diabetic retinopathy analyzed by spectral-domain optical coherence tomography. Retina (Philadelphia, Pa.) 32(3):563CrossRef Regatieri CV, Branchini L, Carmody J et al (2012) Choroidal thickness in patients with diabetic retinopathy analyzed by spectral-domain optical coherence tomography. Retina (Philadelphia, Pa.) 32(3):563CrossRef
11.
Zurück zum Zitat Chung SE, Kang SW, Lee JH et al (2011) Choroidal thickness in polypoidal choroidal vasculopathy and exudative age-related macular degeneration. Ophthalmology 118(5):840–845CrossRefPubMed Chung SE, Kang SW, Lee JH et al (2011) Choroidal thickness in polypoidal choroidal vasculopathy and exudative age-related macular degeneration. Ophthalmology 118(5):840–845CrossRefPubMed
12.
Zurück zum Zitat Gemenetzi M, De Salvo G, Lotery A (2010) Central serous chorioretinopathy: an update on pathogenesis and treatment. Eye 24(12):1743–1756CrossRefPubMed Gemenetzi M, De Salvo G, Lotery A (2010) Central serous chorioretinopathy: an update on pathogenesis and treatment. Eye 24(12):1743–1756CrossRefPubMed
13.
Zurück zum Zitat Imamura Y, Fujiwara T, Margolis R et al (2009) Enhanced depth imaging optical coherence tomography of the choroid in central serous chorioretinopathy. Retina 29(10):1469–1473CrossRefPubMed Imamura Y, Fujiwara T, Margolis R et al (2009) Enhanced depth imaging optical coherence tomography of the choroid in central serous chorioretinopathy. Retina 29(10):1469–1473CrossRefPubMed
14.
Zurück zum Zitat Wu L, Alpizar-Alvarez N (2013) Choroidal imaging by spectral domain-optical coherence tomography. Taiwan J Ophthalmol 3(1):3–13CrossRef Wu L, Alpizar-Alvarez N (2013) Choroidal imaging by spectral domain-optical coherence tomography. Taiwan J Ophthalmol 3(1):3–13CrossRef
15.
Zurück zum Zitat Maruko I, Iida T, Sugano Y et al (2011) Subfoveal choroidal thickness after treatment of Vogt–Koyanagi–Harada disease. Retina 31(3):510–517CrossRefPubMed Maruko I, Iida T, Sugano Y et al (2011) Subfoveal choroidal thickness after treatment of Vogt–Koyanagi–Harada disease. Retina 31(3):510–517CrossRefPubMed
16.
Zurück zum Zitat Reibaldi M, Boscia F, Avitabile T et al (2011) Enhanced depth imaging optical coherence tomography of the choroid in idiopathic macular hole: a cross-sectional prospective study. Am J Ophthalmol 151(1):112–117CrossRefPubMed Reibaldi M, Boscia F, Avitabile T et al (2011) Enhanced depth imaging optical coherence tomography of the choroid in idiopathic macular hole: a cross-sectional prospective study. Am J Ophthalmol 151(1):112–117CrossRefPubMed
17.
Zurück zum Zitat Spaide RF, Koizumi H, Pozonni MC (2008) Enhanced depth imaging spectral-domain optical coherence tomography. Am J Ophthalmol 146(4):496–500CrossRefPubMed Spaide RF, Koizumi H, Pozonni MC (2008) Enhanced depth imaging spectral-domain optical coherence tomography. Am J Ophthalmol 146(4):496–500CrossRefPubMed
18.
Zurück zum Zitat Brown JS, Flitcroft DI, G-s Ying et al (2009) In vivo human choroidal thickness measurements: evidence for diurnal fluctuations. Invest Ophthalmol Vis Sci 50(1):5–12CrossRefPubMed Brown JS, Flitcroft DI, G-s Ying et al (2009) In vivo human choroidal thickness measurements: evidence for diurnal fluctuations. Invest Ophthalmol Vis Sci 50(1):5–12CrossRefPubMed
20.
Zurück zum Zitat Ikuno Y, Tano Y (2009) Retinal and choroidal biometry in highly myopic eyes with spectral-domain optical coherence tomography. Invest Ophthalmol Vis Sci 50(8):3876–3880CrossRefPubMed Ikuno Y, Tano Y (2009) Retinal and choroidal biometry in highly myopic eyes with spectral-domain optical coherence tomography. Invest Ophthalmol Vis Sci 50(8):3876–3880CrossRefPubMed
21.
Zurück zum Zitat Branchini L, Regatieri CV, Flores-Moreno I et al (2012) Reproducibility of choroidal thickness measurements across three spectral domain optical coherence tomography systems. Ophthalmology 119(1):119–123CrossRefPubMed Branchini L, Regatieri CV, Flores-Moreno I et al (2012) Reproducibility of choroidal thickness measurements across three spectral domain optical coherence tomography systems. Ophthalmology 119(1):119–123CrossRefPubMed
22.
Zurück zum Zitat Yamashita T, Yamashita T, Shirasawa M et al (2012) Repeatability and reproducibility of subfoveal choroidal thickness in normal eyes of Japanese using different SD-OCT devices. Invest Ophthalmol Vis Sci 53(3):1102–1107CrossRefPubMed Yamashita T, Yamashita T, Shirasawa M et al (2012) Repeatability and reproducibility of subfoveal choroidal thickness in normal eyes of Japanese using different SD-OCT devices. Invest Ophthalmol Vis Sci 53(3):1102–1107CrossRefPubMed
23.
Zurück zum Zitat Mrejen S, Spaide RF (2013) Optical coherence tomography: imaging of the choroid and beyond. Surv Ophthalmol 58(5):387–429CrossRefPubMed Mrejen S, Spaide RF (2013) Optical coherence tomography: imaging of the choroid and beyond. Surv Ophthalmol 58(5):387–429CrossRefPubMed
Metadaten
Titel
Reproducibility of choroidal thickness measurements in subjects on 3 spectral domain optical coherence tomography machines
verfasst von
Chiang Ling Koay
Matthew Justin Quo
Visvaraja Subrayan
Publikationsdatum
24.08.2016
Verlag
Springer Netherlands
Erschienen in
International Ophthalmology / Ausgabe 3/2017
Print ISSN: 0165-5701
Elektronische ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-016-0306-4

Weitere Artikel der Ausgabe 3/2017

International Ophthalmology 3/2017 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.