Skip to main content
main-content

01.06.2014 | Functional Neuroradiology | Ausgabe 6/2014

Neuroradiology 6/2014

Reproducibility of diffusion tensor imaging in normal subjects: an evaluation of different gradient sampling schemes and registration algorithm

Zeitschrift:
Neuroradiology > Ausgabe 6/2014
Autoren:
Xin Liu, Yong Yang, Jubao Sun, Gang Yu, Jin Xu, Chen Niu, Hongjun Tian, Pan Lin
Wichtige Hinweise

Electronic supplementary material

The online version of this article (doi:10.​1007/​s00234-014-1342-2) contains supplementary material, which is available to authorized users.
Xin Liu and Jubao Sun contributed equally to the manuscript.

Abstract

Introduction

Diffusion tensor imaging (DTI) is very useful for investigating white matter integrity in ageing and neurological disorders; thus, evaluating its reproducibility under different acquisition protocols and analysis methods may assist in the design of clinical studies.

Methods

To measure the reproducibility of DTI in normal subjects, this study include (1) depicting the reproducibility of DTI measurements in commonly used regions-of-interest analysis by intraclass correlation coefficient (ICC) and coefficient of variation (CV), (2) evaluating and comparing inter and intrasession test-retest reproducibility, and (3) illustrating the effect of the number of diffusion-encoding directions (NDED) and registration algorithms on measurement reproducibility.

Results

DTI measurements exhibit high reproducibility, with overall (430/480) ICC ≥ 0.70, (478/480) within-subject CV (CVws) ≤10.00 % and between-subject CV (CVbs) ranging from 1.32 to 13.63 %. Repeated measures ANOVAs and paired t tests were conducted to compare inter and intrasession reproducibility with different diffusion sampling schemes and registration algorithms. Our results also confirmed that increasing the NDED could improve the accuracy and reproducibility of DTI measurements. In addition, we compared reproducibility indices that were derived using different registration algorithms, and a tensor-based deformable registration yielded the most reproducible results. Finally, we found that increasing the NDED could reduce the difference between the reproducibility of measurement derived using different registration algorithms and between the reproducibility of intersession and intrasession.

Conclusion

Our results suggest that the choice of DTI acquisition protocol and post-processing methods can influence the accurate estimation and reproducibility of DTI measurements and should be considered carefully for clinical applications.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de. Zusätzlich können Sie eine Zeitschrift Ihrer Wahl in gedruckter Form beziehen – ohne Aufpreis.

Weitere Produktempfehlungen anzeigen
Zusatzmaterial
Table S1 Reproducibility of DTI measurements using the FLIRTreg registration algorithm. Note: highly reproducible cases (both intra- and intersession ICC ≥ 0.80 and CVws ≤ 10 %) are indicated in bold. Abbreviations: NDED, number of diffusion encoding directions; CC, corpus callosum; GCC, genu of the corpus callosum; SCC, splenium of the corpus callosum; PIC, posterior limb of the internal capsule; AIC, anterior limb of the internal capsule; ICC, intraclass correlation coefficient; CV, coefficient of variation; FA, fractional anisotropy, MD, mean diffusivity; λ∥, axial diffusivity; λ⊥, radial diffusivities. (DOC 93 kb)
234_2014_1342_MOESM1_ESM.doc
Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 6/2014

Neuroradiology 6/2014 Zur Ausgabe
  1. Sie können e.Med Neurologie & Psychiatrie 14 Tage kostenlos testen (keine Print-Zeitschrift enthalten). Der Test läuft automatisch und formlos aus. Es kann nur einmal getestet werden.

  2. Sie können e.Med Neurologie 14 Tage kostenlos testen (keine Print-Zeitschrift enthalten). Der Test läuft automatisch und formlos aus. Es kann nur einmal getestet werden.

  3. Sie können e.Med Radiologie 14 Tage kostenlos testen (keine Print-Zeitschrift enthalten). Der Test läuft automatisch und formlos aus. Es kann nur einmal getestet werden.

Neu im Fachgebiet Radiologie

Meistgelesene Bücher aus der Radiologie

2016 | Buch

Medizinische Fremdkörper in der Bildgebung

Thorax, Abdomen, Gefäße und Kinder

Dieses einzigartige Buch enthält ca. 1.600 hochwertige radiologische Abbildungen und Fotos iatrogen eingebrachter Fremdmaterialien im Röntgenbild und CT.

Herausgeber:
Dr. med. Daniela Kildal

2011 | Buch

Atlas Klinische Neuroradiologie des Gehirns

Radiologie lebt von Bildern! Der vorliegende Atlas trägt dieser Tatsache Rechnung. Sie finden zu jedem Krankheitsbild des Gehirns Referenzbilder zum Abgleichen mit eigenen Befunden.

Autoren:
Priv.-Doz. Dr. med. Jennifer Linn, Prof. Dr. med. Martin Wiesmann, Prof. Dr. med. Hartmut Brückmann

Mail Icon II Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Radiologie und bleiben Sie gut informiert – ganz bequem per eMail.

Bildnachweise