Skip to main content
main-content

01.03.2018 | Original Article | Ausgabe 4/2018 Open Access

Netherlands Heart Journal 4/2018

Reproducibility of right-to-left shunt quantification using transthoracic contrast echocardiography in hereditary haemorrhagic telangiectasia

Zeitschrift:
Netherlands Heart Journal > Ausgabe 4/2018
Autoren:
V. M. M. Vorselaars, S. Velthuis, M. P. Huitema, A. E. Hosman, C. J. J. Westermann, R. J. Snijder, J. J. Mager, M. C. Post
Wichtige Hinweise

Electronic supplementary material

The online version of this article (https://​doi.​org/​10.​1007/​s12471-018-1094-4) contains supplementary material, which is available to authorized users.

Abstract

Aim

Transthoracic contrast echocardiography (TTCE) is recommended for screening of pulmonary arteriovenous malformations (PAVMs) in hereditary haemorrhagic telangiectasia. Shunt quantification is used to find treatable PAVMs. So far, there has been no study investigating the reproducibility of this diagnostic test. Therefore, this study aimed to describe inter-observer and inter-injection variability of TTCE.

Methods

We conducted a prospective single centre study. We included all consecutive persons screened for presence of PAVMs in association with hereditary haemorrhagic telangiectasia in 2015. The videos of two contrast injections per patient were divided and reviewed by two cardiologists blinded for patient data. Pulmonary right-to-left shunts were graded using a three-grade scale. Inter-observer and inter-injection agreement was calculated with κ statistics for the presence and grade of pulmonary right-to-left shunts.

Results

We included 107 persons (accounting for 214 injections) (49.5% male, mean age 45.0 ± 16.6 years). A pulmonary right-to-left shunt was present in 136 (63.6%) and 131 (61.2%) injections for observer 1 and 2, respectively. Inter-injection agreement for the presence of pulmonary right-to-left shunts was 0.96 (95% confidence interval (CI) 0.9–1.0) and 0.98 (95% CI 0.94–1.00) for observer 1 and 2, respectively. Inter-injection agreement for pulmonary right-to-left shunt grade was 0.96 (95% CI 0.93–0.99) and 0.95 (95% CI 0.92–0.98) respectively. There was disagreement in right-to-left shunt grade between the contrast injections in 11 patients (10.3%). Inter-observer variability for presence and grade of the pulmonary right-to-left shunt was 0.95 (95% CI 0.91–0.99) and 0.97 (95% CI 0.95–0.99) respectively.

Conclusion

TTCE has an excellent inter-injection and inter-observer agreement for both the presence and grade of pulmonary right-to-left shunts.
Zusatzmaterial
Video 1 Pulmonary right-to-left shunt grade 1. Transthoracic contrast echocardiogram, apical 4chamber view.
Video 2 Pulmonary right-to-left shunt grade 2. Transthoracic contrast echocardiogram, apical 4chamber view.
Video 3 Pulmonary right-to-left shunt grade 3. Transthoracic contrast echocardiogram, apical 4chamber view.
Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 4/2018

Netherlands Heart Journal 4/2018 Zur Ausgabe

Neu im Fachgebiet Kardiologie

Mail Icon II Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Kardiologie und bleiben Sie gut informiert – ganz bequem per eMail.

Bildnachweise