Skip to main content
Erschienen in: Arthritis Research & Therapy 1/2018

Open Access 01.12.2018 | Letter

Response to: “Monosodium urate crystal deposition associated with the progress of radiographic grade at the sacroiliac joint in axial SpA: a dual-energy CT study”

verfasst von: Andrea S. Klauser, Johann Gruber

Erschienen in: Arthritis Research & Therapy | Ausgabe 1/2018

Hinweise
This comment refers to the article available at: https://​doi.​org/​10.​1186/​s13075-017-1286-0.
Abkürzungen
DECT
dual-energy computed tomography
MSU
monosodium urate
We read with great interest the article by Zhu et al. [1] entitled “Monosodium urate crystal deposition associated with the progress of radiographic grade at the sacroiliac joint in axial SpA: a dual-energy CT study” which was published in Arthritis Research & Therapy in May 2017. We congratulate the authors on attempting to verify gouty deposits at the sacroiliac joint in axial SpA patients using dual-energy computed tomography (DECT), a relatively new imaging method to detect gouty deposits.
Deposition of monosodium urate (MSU) in the spine is a rare manifestation of gout, and only case and series reports exist in the literature [2].
Axial SpA patients without gout and with no hyperuricemia were included in this study; however, a case–control group would be of interest to compare results with gout patients and with nonaxial SpA patients in order to elucidate the prevalence of spinal gout involvement, which is actually unknown [2].
In addition, matters of concern arise when considering the presented figures.
DECT artifacts according to ACR/EULAR guidelines have to be differentiated from gouty deposits when submillimeter deposits, skin deposits, deposits obscured by motion, beam hardening, and vascular artifact are present [3, 4].
Submillimeter artifacts may be single or may form part of a diffuse pattern of the scatter. They are thought to occur as a result of and as a form of noise [4].
Furthermore, it has been shown recently using DECT that MSU crystal deposition is generally present within the joint, on the bone surface, and within bone erosion, but is not observed within bone in the absence of a cortical break [5]. Interestingly, the green DECT pixels presented in the figures (rated as MSU deposits) are mainly depicted inside the sacrum and the iliac bone, and not in the sacroiliac joint nor pronounced on the bone surface. This is contrary to the “bone cortex concept” where MSU crystals deposit outside bone and contribute to bone erosion through an “outside-in” mechanism [5].

Acknowledgements

Not applicable.

Funding

Not applicable.

Availability of data and materials

Data sharing is not applicable to this article as no datasets were generated or analyzed during the current study.
Not applicable.
Not applicable.

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
Literatur
3.
Zurück zum Zitat Mallinson PI, Coupal T, Reisinger C, et al. Artifacts in dual-energy CT gout protocol: a review of 50 suspected cases with an artifact identification guide. AJR. 2014;203:103–9.CrossRef Mallinson PI, Coupal T, Reisinger C, et al. Artifacts in dual-energy CT gout protocol: a review of 50 suspected cases with an artifact identification guide. AJR. 2014;203:103–9.CrossRef
4.
Zurück zum Zitat Neogi T, Jansen TL, Dalbeth N, et al. 2015 Gout Classification Criteria: an American College of Rheumatology/European League Against Rheumatism collaborative initiative. Arthritis Rheum Dis. 2015;67:2557–68.CrossRef Neogi T, Jansen TL, Dalbeth N, et al. 2015 Gout Classification Criteria: an American College of Rheumatology/European League Against Rheumatism collaborative initiative. Arthritis Rheum Dis. 2015;67:2557–68.CrossRef
Metadaten
Titel
Response to: “Monosodium urate crystal deposition associated with the progress of radiographic grade at the sacroiliac joint in axial SpA: a dual-energy CT study”
verfasst von
Andrea S. Klauser
Johann Gruber
Publikationsdatum
01.12.2018
Verlag
BioMed Central
Erschienen in
Arthritis Research & Therapy / Ausgabe 1/2018
Elektronische ISSN: 1478-6362
DOI
https://doi.org/10.1186/s13075-018-1524-0

Weitere Artikel der Ausgabe 1/2018

Arthritis Research & Therapy 1/2018 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.