Skip to main content
Erschienen in: Clinical Oral Investigations 5/2019

06.10.2018 | Original Article

Retentive force of PEEK secondary crowns on zirconia primary crowns over time

verfasst von: Oliver Schubert, Josef Reitmaier, Josef Schweiger, Kurt Erdelt, Jan-Frederik Güth

Erschienen in: Clinical Oral Investigations | Ausgabe 5/2019

Einloggen, um Zugang zu erhalten

Abstract

Objectives

The purpose of the present study was to evaluate the retentive forces of CAD/CAM-fabricated polyetheretherketone (PEEK) secondary crowns on zirconia primary crowns over an artificial aging period representing 10 years of clinical service and compare them to electroformed secondary crowns made from pure gold.

Material and methods

Implant-supported zirconia primary crowns (N = 20) were CAD/CAM milled and provided either with electroformed secondary crowns (group ZE; N = 10) or CAD/CAM-fabricated PEEK secondary crowns (group ZP; N = 10). All secondary crowns were attached to a casted tertiary structure to ensure adequate stability. A universal testing machine was used to determine the retentive force values at baseline and after 1, 3, 5, and 10 years of simulated aging in the presence of artificial saliva. Data were analyzed applying Kolmogorov-Smirnov, Kruskal-Wallis, and Mann-Whitney U test. Level of significance was set at p < 0.05.

Results

Retentive forces were not different for the groups ZE and ZP at baseline (median ZE 2.85 N; ZP 2.8 N; p ≤ 0.218). Because retentive force values changed significantly over simulation time for group ZE (Kruskal-Wallis; p ≤ 0.028), the values between the test groups ZE and ZP differed significantly (Mann-Whitney U) at 5 years (ZE 3.03 N; ZP 2.76 N; p ≤ 0.003) and 10 years (ZE 3.1 N; ZP 2.78 N; p ≤ 0.011).

Conclusions

PEEK secondary crowns exhibit stable retentive force values over 10 years of simulated aging showing no signs of deterioration while the retentive force values of electroformed secondary crowns increase over time.

Clinical relevance

PEEK might be a suitable alternative to proven metallic materials for the fabrication of secondary crowns.
Literatur
2.
Zurück zum Zitat Starr W (1886) Removable bridge-work. - porcelain cap-crowns. The Dental cosmos; a monthly record of dental science 28 (1):17–19 Starr W (1886) Removable bridge-work. - porcelain cap-crowns. The Dental cosmos; a monthly record of dental science 28 (1):17–19
3.
Zurück zum Zitat Langer A (1981) Telescope retainers for removable partial dentures. J Prosthet Dent 45(1):37–43CrossRefPubMed Langer A (1981) Telescope retainers for removable partial dentures. J Prosthet Dent 45(1):37–43CrossRefPubMed
5.
Zurück zum Zitat Rammelsberg P, Bernhart G, Lorenzo Bermejo J, Schmitter M, Schwarz S (2014) Prognosis of implants and abutment teeth under combined tooth-implant-supported and solely implant-supported double-crown-retained removable dental prostheses. Clin Oral Implants Res 25(7):813–818. https://doi.org/10.1111/clr.12197 CrossRefPubMed Rammelsberg P, Bernhart G, Lorenzo Bermejo J, Schmitter M, Schwarz S (2014) Prognosis of implants and abutment teeth under combined tooth-implant-supported and solely implant-supported double-crown-retained removable dental prostheses. Clin Oral Implants Res 25(7):813–818. https://​doi.​org/​10.​1111/​clr.​12197 CrossRefPubMed
7.
Zurück zum Zitat Böttger H (1953) Die prothetische Versorgung des Lü̧ckengebisses mit Teleskopprothesen. Zahnärztl Rundsch (62):18–23 Böttger H (1953) Die prothetische Versorgung des Lü̧ckengebisses mit Teleskopprothesen. Zahnärztl Rundsch (62):18–23
8.
Zurück zum Zitat Hofmann M (1966) Die Versorgung von Gebissen mit einzelstehenden Restzähnen mittels sog. Cover-Denture-Prothesen. Dtsch Zahnärztl Z 21:478–482 Hofmann M (1966) Die Versorgung von Gebissen mit einzelstehenden Restzähnen mittels sog. Cover-Denture-Prothesen. Dtsch Zahnärztl Z 21:478–482
9.
Zurück zum Zitat Körber K (1968) Konuskronen – ein physikalisch definiertes Teleskopsystem. Dtsch Zahnärztl Z 23:619–630PubMed Körber K (1968) Konuskronen – ein physikalisch definiertes Teleskopsystem. Dtsch Zahnärztl Z 23:619–630PubMed
10.
Zurück zum Zitat Koller B, Att W, Strub JR (2011) Survival rates of teeth, implants, and double crown-retained removable dental prostheses: a systematic literature review. Int J Prosthodont 24(2):109–117PubMed Koller B, Att W, Strub JR (2011) Survival rates of teeth, implants, and double crown-retained removable dental prostheses: a systematic literature review. Int J Prosthodont 24(2):109–117PubMed
11.
Zurück zum Zitat Wostmann B, Balkenhol M, Kothe A, Ferger P (2008) Dental impact on daily living of telescopic crown-retained partial dentures. Int J Prosthodont 21(5):419–421PubMed Wostmann B, Balkenhol M, Kothe A, Ferger P (2008) Dental impact on daily living of telescopic crown-retained partial dentures. Int J Prosthodont 21(5):419–421PubMed
13.
Zurück zum Zitat Langer A (1980) Telescope retainers and their clinical application. J Prosthet Dent 44(5):516–522 doi:0022-3913(80)90070-0CrossRefPubMed Langer A (1980) Telescope retainers and their clinical application. J Prosthet Dent 44(5):516–522 doi:0022-3913(80)90070-0CrossRefPubMed
15.
Zurück zum Zitat Diedrichs G, Rosenhain P (1991) Galvano-Außenteleskope in der direkten Technik. Quintessenz 42:49–55PubMed Diedrichs G, Rosenhain P (1991) Galvano-Außenteleskope in der direkten Technik. Quintessenz 42:49–55PubMed
16.
Zurück zum Zitat Vence BS (1997) Electroforming technology for galvanoceramic restorations. J Prosthet Dent 77(4):444–449CrossRefPubMed Vence BS (1997) Electroforming technology for galvanoceramic restorations. J Prosthet Dent 77(4):444–449CrossRefPubMed
17.
Zurück zum Zitat Weigl P, Hahn L, Lauer HC (2000) Advanced biomaterials used for a new telescopic retainer for removable dentures. J Biomed Mater Res 53(4):320–336CrossRefPubMed Weigl P, Hahn L, Lauer HC (2000) Advanced biomaterials used for a new telescopic retainer for removable dentures. J Biomed Mater Res 53(4):320–336CrossRefPubMed
18.
Zurück zum Zitat Weigl P, Lauer HC (2000) Advanced biomaterials used for a new telescopic retainer for removable dentures. J Biomed Mater Res 53(4):337–347CrossRefPubMed Weigl P, Lauer HC (2000) Advanced biomaterials used for a new telescopic retainer for removable dentures. J Biomed Mater Res 53(4):337–347CrossRefPubMed
19.
Zurück zum Zitat Bayer S, Kraus D, Keilig L, Golz L, Stark H, Enkling N (2012) Wear of double crown systems: electroplated vs. casted female part. J Appl Oral Sci 20(3):384–391CrossRefPubMedPubMedCentral Bayer S, Kraus D, Keilig L, Golz L, Stark H, Enkling N (2012) Wear of double crown systems: electroplated vs. casted female part. J Appl Oral Sci 20(3):384–391CrossRefPubMedPubMedCentral
21.
Zurück zum Zitat Faber F, Huber C (2001) Electroformed telescope crowns – a hydraulic system. J Dent Res 80(Spec Iss):551 Faber F, Huber C (2001) Electroformed telescope crowns – a hydraulic system. J Dent Res 80(Spec Iss):551
24.
Zurück zum Zitat Bayer S, Kraus D, Keilig L, Golz L, Stark H, Enkling N (2012) Changes in retention force with electroplated copings on conical crowns: a comparison of gold and zirconia primary crowns. Int J Oral Maxillofac Implants 27(3):577–585PubMed Bayer S, Kraus D, Keilig L, Golz L, Stark H, Enkling N (2012) Changes in retention force with electroplated copings on conical crowns: a comparison of gold and zirconia primary crowns. Int J Oral Maxillofac Implants 27(3):577–585PubMed
27.
Zurück zum Zitat Miyazaki T, Hotta Y, Kunii J, Kuriyama S, Tamaki Y (2009) A review of dental CAD/CAM: current status and future perspectives from 20 years of experience. Dent Mater J 28:44–56CrossRefPubMed Miyazaki T, Hotta Y, Kunii J, Kuriyama S, Tamaki Y (2009) A review of dental CAD/CAM: current status and future perspectives from 20 years of experience. Dent Mater J 28:44–56CrossRefPubMed
29.
Zurück zum Zitat Skinner HB (1988) Composite technology for total hip arthroplasty. Clin Orthop Relat Res (235):224-236 Skinner HB (1988) Composite technology for total hip arthroplasty. Clin Orthop Relat Res (235):224-236
34.
Zurück zum Zitat Stock V, Schmidlin PR, Merk S, Wagner C, Roos M, Eichberger M, Stawarczyk B (2016) PEEK primary crowns with cobalt-chromium, zirconia and galvanic secondary crowns with different tapers-a comparison of retention forces. Materials (Basel) 9(3). https://doi.org/10.3390/ma9030187 Stock V, Schmidlin PR, Merk S, Wagner C, Roos M, Eichberger M, Stawarczyk B (2016) PEEK primary crowns with cobalt-chromium, zirconia and galvanic secondary crowns with different tapers-a comparison of retention forces. Materials (Basel) 9(3). https://​doi.​org/​10.​3390/​ma9030187
35.
Zurück zum Zitat Wagner C, Stock V, Merk S, Schmidlin PR, Roos M, Eichberger M, stawarczyk B (2018) Retention load of telescopic crowns with different taper angles between cobalt-chromium and polyetheretherketone made with three different manufacturing processes examined by pull-off test. J Prosthodont 27(2):162–168CrossRefPubMed Wagner C, Stock V, Merk S, Schmidlin PR, Roos M, Eichberger M, stawarczyk B (2018) Retention load of telescopic crowns with different taper angles between cobalt-chromium and polyetheretherketone made with three different manufacturing processes examined by pull-off test. J Prosthodont 27(2):162–168CrossRefPubMed
36.
Zurück zum Zitat Merk S, Wagner C, Stock V, Eichberger M, Schmidlin PR, Roos M, Stawarczyk B (2016) Suitability of secondary PEEK telescopic crowns on zirconia primary crowns: the influence of fabrication method and taper. Materials (Basel) 9(11). https://doi.org/10.3390/ma9110908 Merk S, Wagner C, Stock V, Eichberger M, Schmidlin PR, Roos M, Stawarczyk B (2016) Suitability of secondary PEEK telescopic crowns on zirconia primary crowns: the influence of fabrication method and taper. Materials (Basel) 9(11). https://​doi.​org/​10.​3390/​ma9110908
38.
Zurück zum Zitat Ohkawa S, Okane H, Nagasawa T, Tsuru H (1990) Changes in retention of various telescope crown assemblies over long-term use. J Prosthet Dent 64(2):153–158CrossRefPubMed Ohkawa S, Okane H, Nagasawa T, Tsuru H (1990) Changes in retention of various telescope crown assemblies over long-term use. J Prosthet Dent 64(2):153–158CrossRefPubMed
40.
Zurück zum Zitat Hatton MN, Levine MJ, Margarone JE, Aguirre A (1987) Lubrication and viscosity features of human saliva and commercially available saliva substitutes. J Oral Maxillofac Surg 45(6):496–499CrossRefPubMed Hatton MN, Levine MJ, Margarone JE, Aguirre A (1987) Lubrication and viscosity features of human saliva and commercially available saliva substitutes. J Oral Maxillofac Surg 45(6):496–499CrossRefPubMed
41.
Zurück zum Zitat Dillschneider T, Nothdurft F, Abed-Rabbo M, Mitov G, Pospiech P (2009) In vitro-investigations on the wear behavior of different double crown systems. Dent Mater 25(5):e20CrossRef Dillschneider T, Nothdurft F, Abed-Rabbo M, Mitov G, Pospiech P (2009) In vitro-investigations on the wear behavior of different double crown systems. Dent Mater 25(5):e20CrossRef
42.
Zurück zum Zitat Becker H (1982) Untersuchung der Abzugskräfte abnehmbarer Teleskop-Prothesen. Zahnärztl Prax 33:153–156PubMed Becker H (1982) Untersuchung der Abzugskräfte abnehmbarer Teleskop-Prothesen. Zahnärztl Prax 33:153–156PubMed
Metadaten
Titel
Retentive force of PEEK secondary crowns on zirconia primary crowns over time
verfasst von
Oliver Schubert
Josef Reitmaier
Josef Schweiger
Kurt Erdelt
Jan-Frederik Güth
Publikationsdatum
06.10.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Oral Investigations / Ausgabe 5/2019
Print ISSN: 1432-6981
Elektronische ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-018-2657-x

Weitere Artikel der Ausgabe 5/2019

Clinical Oral Investigations 5/2019 Zur Ausgabe

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.