Retinal VEGF levels correlate with ocular circulation measured by a laser speckle-micro system in an oxygen-induced retinopathy rat model

Zeitschrift:
Graefe's Archive for Clinical and Experimental Ophthalmology > Ausgabe 10/2017
Autoren:
Tadashi Matsumoto, Yuta Saito, Takashi Itokawa, Tomoaki Shiba, Mari S. Oba, Haruo Takahashi, Yuichi Hori

Abstract

Purpose

We used a Laser speckle flowgraphy (LSFG)-micro system to examine the relationship between ocular blood flow and retinal vascular endothelial growth factor (VEGF) at retinopathy onset in oxygen-induced ischemic retinopathy (OIR) model rats.

Methods

Sixteen 50/10 OIR rats were compared with 17 control rats reared in room air. In postnatal day 14 (P14) and P18 rats, we measured and analyzed the left eye’s mean blur rate (MBR) by setting a rubber band on the optic nerve head center, using the LSFG-Micro. At P18, the rats were sacrificed and their left-eye retinas were fixed, flat-mounted and stained with adenosine diphosphatase (ADPase). The right-eye retinas were homogenized; the lysate was centrifuged for an enzyme-linked immunosorbent assay (ELISA). The avascular area was measured as the percentage (%AVA) of the total retinal area. Retinal VEGF was measured by an ELISA.

Results

The examination’s reproducibility was good. Our multivariate linear mixed model analysis revealed significantly high MBRs in the OIR rats (p = 0.0017). In the P18 OIR rats, significant correlations were seen between the MBR and %AVA (r = 0.80, p = 0.0002) and between the MBR and VEGF (r = 0.76, p = 0.0006).

Conclusions

The LSFG-Micro provided reproducible blood flow measurements in neonatal rats. Because of the vitreous blood vessels, measurement of only the retinal vessels was not possible. However, the MBR was higher in the OIR rats than in the control rats, and the MBR and %AVA were correlated, as were the MBR and retinal VEGF. The MBR may thus serve as an indicator of OIR severity.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag als Mediziner

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Alle e.Med Abos bis 30. April 2021 zum halben Preis!

Jetzt e.Med zum Sonderpreis bestellen!

Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 10/2017

Graefe's Archive for Clinical and Experimental Ophthalmology 10/2017 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

08.03.2021 | Video plus | Ausgabe 4/2021

„Simple limbal epithelial transplantation“ (SLET)

Eine einfache Technik zur Behandlung der kompletten, einseitigen Limbusstammzellinsuffizienz. Videobeitrag