Skip to main content
Erschienen in: World Journal of Surgical Oncology 1/2014

Open Access 01.12.2014 | Research

Risk factors for venous port migration in a single institute in Taiwan

verfasst von: Wen-Chieh Fan, Cheng-Han Wu, Ming-Ju Tsai, Ying-Ming Tsai, Hsu-Liang Chang, Jen-Yu Hung, Pei-Huan Chen, Chih-Jen Yang

Erschienen in: World Journal of Surgical Oncology | Ausgabe 1/2014

download
DOWNLOAD
print
DRUCKEN
insite
SUCHEN

Abstract

Background

An implantable port device provides an easily accessible central route for long-term chemotherapy. Venous catheter migration is one of the rare complications of venous port implantation. It can lead to side effects such as pain in the neck, shoulder, or ear, venous thrombosis, and even life-threatening neurologic problems. To date, there are few published studies that discuss such complications.

Methods

This retrospective study of venous port implantation in a single center, a Taiwan hospital, was conducted from January 2011 to March 2013. Venous port migration was recorded along with demographic and characteristics of the patients.

Results

Of 298 patients with an implantable import device, venous port migration had occurred in seven, an incidence rate of 2.3%. All seven were male and had received the Bard port Fr 6.6 which had smaller size than TYCO port Fr 7.5 and is made of silicon. Significantly, migration occurred in male patients (P = 0.0006) and in those with lung cancer (P = 0.004). Multivariable logistic regression analysis revealed that lung cancer was a significant risk factor for port migration (odds ratio: 11.59; P = 0.0059). The migration rate of the Bard port Fr 6.6 was 6.7%. The median time between initial venous port implantation and port migration was 35.4 days (range, 7 to 135 days) and 71.4% (5/7) of patients had port migration within 30 days after initial port implantation.

Conclusions

Male sex and lung cancer are risk factors for venous port migration. The type of venous port is also an important risk factor.
Hinweise

Electronic supplementary material

The online version of this article (doi:10.​1186/​1477-7819-12-15) contains supplementary material, which is available to authorized users.
Wen-Chieh Fan, Cheng-Han Wu contributed equally to this work.

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

CJY designed the study. WCF and CHW drafted the manuscript. MJT did the analysis. YMT and HLC participated in study design and data collection. JYH and PHC collected data and processed the data. All of the authors read and approved the final manuscript.
Abkürzungen
BMI
Body mass index.

Background

Venous port implantation is widely used for the safe delivery of systemic chemotherapy in patients with cancer. However, various complications have been documented and the total complication rate ranges from 0.4% to 29% [16]. Catheter migration is a rare complication with an unknown cause that occurs in about 0.9 to 2% of patients [3, 5, 7, 8]. It can lead to side effects such as pain in the neck, shoulder, or ear, venous thrombosis [912], and even life-threatening neurologic problems [1315]. Because of its rarity, very few studies have been published that extensively tackled venous catheter migration [3, 7]. This retrospective study is an investigation of venous port migration in a hospital in Taiwan. Related literature is also reviewed.

Methods

All patients who underwent venous port implantation (BardPort® 6.6 Fr implantable port, NJ, USA (Bard port) or Autosuture Chemosite® Fr 7.5, Tyco healthcare group, Connecticut, USA (TYCO port)) for chemotherapy at Kaohsiung Municipal Ta-Tung Hospital between 1 January 2011 and 31 March 2013, were retrospectively evaluated. The Bard port® was made of silicon while the Autosuture Chemosite® was made of polyurethane (PU). The procedures were all performed by an experienced surgeon (Dr. WC Fan) under local anesthesia. The vessel cut-down method was used for catheter cannulation. After venostomy, the distal end of the entry vessel was controlled and the catheter was inserted via the superior vena cava. The cephalic vein was the first choice for entry exploration and occasionally, the subclavian vein was the point of entry if the cephalic vein was difficult to access.
All locations of the implanted venous ports were confirmed by fluoroscopy and post-operative x-rays. The surgeon ensured that all of the tips of the venous catheters were located at the junction of the superior vena cava and right atrium (cavo-atrial junction) intra-operatively. The cavo-atrial junction was the point at which the superior vena cava met and joined the superior wall of the right atrium. For purposes of radiographic visualization, the most reliable indicators of the junction were the carina and the overlying vertebrae. The junction lay two vertebral body units below the carina [16].
The term ‘venous port migration’ referred to a venous port that was not in the correct position. This was diagnosed based on chest x-ray taken before the course of chemotherapy in a patient (Figure 1). The Institutional Review Board of Kaohsiung Medical University Hospital approved this study.
Data were entered and analyzed using the JMP statistical software (version 9.0, SAS Institute Inc., Cary, NC, USA). Demographic data, underlying cancer, and related covariates were compared between the group with and without port migration using the Fisher’s exact test for categorical variables or Wilcoxon rank sum test for continuous variables. To identify the major factors associated with port migration, multivariable logistic regression was performed. Statistical significance level was set at P < 0.05.

Results

A total of 298 patients with mean (± standard deviation) age of 61.4 ± 12.3 years were enrolled. Among them, 145 (48.7%) were male (Table 1). Moreover, 104 patients received the Bard port and 194 received the TYCO port. The patients who received the Bard port implantation were older, with male predominance. More patients in the Bard port group received their port through the right side via the cephalic vein. In terms of port migration, the Bard port had a significantly higher migration rate, up to 6.7%, compared to 0% of the TYCO port (P = 0.0006).
Table 1
Baseline characteristics of the patients using different ports
 
All patients
Bard port
TYCO port
P value
 
n
%
n
%
n
%
 
Patient number
298
 
104
 
194
  
Age
      
0.0116
  mean ± standard deviation
61.4 ± 12.3
63.9 ± 11.3
60.1 ± 12.7
 
  median (inter-quartile range)
61 (54 to 70.8)
63.1 (56.3 to 72)
60 (51 to 69)
 
Sex
      
0.0034
  Female
153
51.3%
41
39.4%
112
57.7%
 
  Male
145
48.7%
63
60.6%
82
42.3%
 
Body mass index
      
0.1077
  mean ± standard deviation
24.2 ± 6.8
23.4 ± 3.6
24.7 ± 8.0
 
  medium (inter-quartile range)
23.6 (21.1 to 26.4)
23.4 (21.1 to 25.4)
23.9 (21.0 to 26.7)
 
Migration
      
0.0006
  No
291
97.7%
97
93.3%
194
100.0%
 
  Yes
7
2.3%
7
6.7%
0
0.0%
 
Side
      
< 0.0001
  Left
97
32.6%
19
18.3%
78
40.2%
 
  Right
201
67.5%
85
81.7%
116
59.8%
 
Entering vessel
      
< 0.0001
  Cephalic vein
261
87.6%
102
98.1%
159
82.0%
 
  Subclavian vein
37
12.4%
2
1.9%
35
18.0%
 
Malignancy (indication for the port)
       
  Head and neck tumor
17
5.7%
4
3.9%
13
6.7%
 
  Lung cancer
59
19.8%
32
30.8%
27
13.9%
 
  Esophageal cancer
2
0.7%
0
0.0%
2
1.0%
 
  Breast cancer
55
18.5%
4
3.9%
51
26.3%
 
  Gastric cancer
14
4.7%
7
6.7%
7
3.6%
 
  Colorectal cancer
64
21.5%
29
27.9%
35
18.0%
 
  Hepatobiliary and pancreatic tumor
8
2.7%
3
2.9%
5
2.6%
 
  Ovary cancer and cervical cancer
26
8.7%
7
6.7%
19
9.8%
 
  Urological cancer
37
12.4%
12
11.5%
25
12.9%
 
  Leukemia and lymphoma
11
3.7%
3
2.9%
8
4.1%
 
  Other malignancy
3
1.0%
1
1.0%
2
1.0%
 
  Malnutrition, no malignancy
2
0.7%
2
1.9%
0
0.0%
 
Lung cancer
      
0.0007
  Yes
59
19.8%
32
30.8%
27
13.9%
 
  No
239
80.2%
72
69.2%
167
86.1%
 
Based on the occurrence of port migration, the patients were further classified into the migration group and non-migration group (Table 2). The mean age and mean body mass index (BMI) did not differ significantly between the two groups. Venous port migration occurred in only seven patients in this retrospective study. All of them were male, used the Bard port, and received their port via the cephalic vein. Five (71.4%) of them were lung cancer patients.
Table 2
Characteristics of the patients with and without port migration
 
Migration group
Non-migration group
P value
 
n
%
n
%
 
Patient number
7
 
291
  
Age
    
0.1181
  mean ± SD
68.1 ± 10.7
61.2 ± 12.4
 
  median (inter-quartile range)
71 (62 to 74)
61 (54 to 70.3)
 
Gender
    
0.0060
  Female
0
0.0%
153
52.6%
 
  Male
7
100.0%
138
47.4%
 
Body mass index
    
0.3211
  mean ± standard deviation
24.9 ± 1.8
24.2 ± 6.9
 
  medium (inter-quartile range)
24.7 (23.3 to 26.9)
23.6 (21 to 26.4)
 
Venous port type
    
0.0006
  Bard Fr 6.6
7
100.0%
97
33.3%
 
  TYCO Fr 7.5
0
0.0%
194
66.7%
 
Side
    
0.4338
  Left
1
14.3%
96
33.0%
 
  Right
6
85.7%
195
67.0%
 
Entering vessel
    
0.6025
  Cephalic vein
7
100.0%
254
87.3%
 
  Subclavian vein
0
0.0%
37
12.7%
 
Malignancy (indication for the port)
     
  Head and neck tumor
0
0.0%
17
5.8%
 
  Lung cancer
5
71.4%
54
18.6%
 
  Esophageal cancer
0
0.0%
2
0.7%
 
  Breast cancer
0
0.0%
55
18.9%
 
  Gastric cancer
1
14.3%
13
4.5%
 
  Colorectal cancer
0
0.0%
64
22.0%
 
  Hepatobiliary and pancreatic tumor
0
0.0%
8
2.7%
 
  Ovary cancer and cervical cancer
0
0.0%
26
8.9%
 
  Urological cancer
0
0.0%
37
12.7%
 
  Leukemia and lymphoma
1
14.3%
10
3.4%
 
  Other malignancy
0
0.0%
3
1.0%
 
  Malnutrition, no malignancy
0
0.0%
2
0.7%
 
Lung cancer
    
0.0040
  Yes
5
71.4%
54
18.6%
 
  No
2
28.6%
237
81.4%
 
Multivariable logistic regression analysis of the factors related to port migration revealed that lung cancer was a significant risk factor for port migration (odds ratio (OR): 11.59, 95% confidence interval (CI): 2.25 to 87.73; P = 0.0059). Sex and venous port type were not included in the model because all of the patients in the migration group were male and had been fitted with the Bard port (Table 3).
Table 3
Multivariable logistic regression analysis of factors affecting port migration
Variables
Odds Ratio
95%CI
P value
All study subjects
   
  Age > 60 versus age ≤ 60
4.85
(0.77 to 94.61)
0.1542
  BMI ≥ 24 versus BMI < 24
2.60
(0.50 to 15.34)
0.2578
  Right versus left
2.15
(0.31 to 42.73)
0.4980
  Lung cancer versus others
11.59
(2.25 to 87.73)
0.0059
Patients using Bard port
   
  Age > 60 versus age ≤ 60
4.28
(0.64 to 86.22)
0.2019
  BMI ≥ 24 versus BMI < 24
2.46
(0.47 to 14.54)
0.2877
  Right versus left
1.22
(0.16 to 25.72)
0.8638
  Lung cancer versus others
7.59
(1.47 to 58.03)
0.0235
Male patients
   
  Age > 60 versus age ≤ 60
3.35
(0.51 to 68.47)
0.2826
  BMI ≥ 24 versus BMI < 24
2.45
(0.47 to 14.56)
0.2911
  Right versus left
2.27
(0.33 to 45.38)
0.4704
  Lung cancer versus others
7.03
(1.37 to 53.15)
0.0283
Lung cancer patients
   
  Age > 60 versus age ≤ 60
2.59
(0.34 to 53.55)
0.4152
  BMI ≥ 24 versus BMI < 24
1.65
(0.19 to 12.53)
0.6216
  Right versus left
1.32
(0.14 to 28.65)
0.8201
The median time between initial venous port implantation and port migration was 35.4 days (range, 7 to 135 days), 71.4% of which occurred within 30 days after initial port implantation.
There were no complications associated with the port migration as it was promptly detected before intravenous chemotherapy was administered. All of the patients successfully underwent surgical revision of the venous port and no recurrence of port migration was noted till the end of the study.

Discussion

This report demonstrates that the type of venous port may lead to different migration rates. Moreover, male sex and lung cancer patients also have significantly higher migration rates.
An implantable port device provides easy access for long-term chemotherapy. A recent retrospective analysis of more than 3,000 chest-port placements by interventional radiologists provides a good analysis of outcomes, including a nearly 100% technical success rate and an overall complication rate of 11.8% (1.3% peri-procedural, 3.3% early, and 9.4% late complications) [17]. Early complications include pneumothorax, hematoma, malposition, embolism, or arrhythmia, which are often related to the placement technique. Delayed complications include skin necrosis, infection, catheter fracture, occlusion, thrombosis, and migration [1, 2, 68, 17].
Infectious and thrombotic issues dominate port complications. The reported rates of long-term venous access infections range from 0.6% to 27% and depend on catheter location, catheter type, and patient’s immune status [18]. Spontaneous venous port migration is rare and occurs in about 0.9 to 2% of patients, according to published articles [3, 5, 7, 8]. In one study, the indicated incidence of catheter migration is about 0.04/1,000 catheter days.
In fluoroscopy-assisted port catheter implantation, primary migration (intra-operative) of the catheter tip is rare but secondary migration (post-operative) may occur due to high intra-thoracic pressure, arm movement, or other unknown causes. This current study reveals a similar incidence of venous port migration of 2.34%. However, there is a significantly higher incidence of venous port migration in patients whose venous port is Bard Fr 6.6 compared to the Autosuture Chemosite® Fr 7.5. Some reasons can be posited. The smaller caliber port (Bardport® Fr 6.6) may be more flexible and have more potential of migrating to the ipsilateral internal jugular vein. Furthermore, BardPort® is made of silicon whereas the Autosuture Chemosite® is made of PU. Silicon is more flexible than PU and this may account for the higher migration rate.
In a report of Wu et al., there is no difference between any port types. However, the incidence of migration in the Bard Fr 6.6 is as high as 3.69% (15/406), much higher than that of other types [3].
The most common migration site is the internal jugular vein. Sometimes, catheters migrate to the peri-cardiophrenic vein and cause cardiac tamponade [19]. Cough-induced port migration to the right axillary vein has also been reported. Other migration/malposition sites are the left subclavian vein, right internal thoracic vein, inferior thyroid vein, left brachial vein, and right brachiocephalic vein. All of the seven cases involve catheter migration into the ipsilateral internal jugular vein. In addition, a high infusion flow rate can also make the tip migrate.
Wu et al. have stated that shallow catheter-tip location and the presence of lung cancer are risk factors for catheter migration. Strategies that ensure low catheter-tip location and avoid increased thoracic pressure may be useful preventive measures [3]. Once migration is detected, prompt correction is important. A catheter tip position in the right atrium or ventricle may cause cardiac arrhythmia, perforation, tamponade, or thrombosis. When the central venous catheter tip is located in an undesirable site, the injected drugs or fluid will also directly enter a small caliber vein and subsequently induce complications like neck pain, shoulder pain, ear pain, venous phlebitis, or thrombosis. Some venous port migrations have been detected following chest x-ray in patients who complain of right neck pain.
The inadvertent infusion of irritant drugs may be life-threatening if neurologic complications and cortical vein thrombosis occur [13, 14]. Fortunately, no complications developed in the study period because each migration event was promptly detected prior to chemotherapy.
The mechanism of venous port migration remains unclear but physical forces acting on the catheter has been proposed, including increased intra-thoracic pressure due to coughing, sneezing, or weight lifting, changes in body position, or physical movements like abduction or adduction of the arms or hyper-extension of the shoulder [3, 10]. Among these possible mechanisms, cough is the most common in several case reports [12]; severe cough can generate up to 300 mmHg of intra-thoracic pressure against a closed glottis, followed by forceful expulsion of air and secretions via the glottic opening. Vigorous changes in intra-thoracic pressure may result in herniation of a short segment of the shaft of the catheter into the jugular vein [20]. Repeated cough may cause progressive herniation and eventually complete the caudal migration of the catheter tip [3]. Moreover, cough is the most common symptom in patients with lung cancer. This hypothesis may explain why, in the study by Wu et al. and in the present study, lung cancer patients have a higher incidence of migration than other cancers. A high infusion flow rate can also lead to tip migrate, as reported.
In the current study, venous port migrations occur early after implantation. In a swine model, central venous catheters have a partial or circumferential mixed cellular and non-cellular covering consisting of smooth muscle cells, thrombus, and areas with endothelial cell populations. Less prominent cellularity and more prominent collagen content develop after 30 to 45 days. With longer catheter in-dwelling time, an endothelial layer, indistinguishable from the adjacent vein wall, covers the catheter surface [21]. The experiment may explain why migration occurs within 30 days in most of the patients in the present study.
Once migration is detected, prompt revision is important to avoid complications. Re-positioning through either surgery-based revision or radiologic interventional procedure shows very high initial success rates [7, 12, 22]. The trans-femoral snaring technique is also a quick and easy method to re-position the catheter tip [23].
A limitation of this study is its small case number; therefore further large-scale studies are warranted.

Conclusion

This is the first study to report that the type of venous port may affect the port migration rate. Male sex and lung cancer patients also have significantly higher migration rates. Port migration often occurs within 30 days after the initial implantation. Periodic check-ups by chest X-ray of catheter location are crucial for detecting catheter tip migration and for early intervention to prevent potential complications.

Acknowledgements

The authors express their gratitude to staff of the Statistical Analysis Laboratory, Department of Medical Research, Kaohsiung Medical University Hospital, Kaohsiung Medical University for their assistance. The work was supported by the grant (kmtth-102-035) of Kaohsiung Municipal Ta-Tung Hospital, Kaohsiung Medical University.
Open Access This article is published under license to BioMed Central Ltd. This is an Open Access article is distributed under the terms of the Creative Commons Attribution License ( https://​creativecommons.​org/​licenses/​by/​2.​0 ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

CJY designed the study. WCF and CHW drafted the manuscript. MJT did the analysis. YMT and HLC participated in study design and data collection. JYH and PHC collected data and processed the data. All of the authors read and approved the final manuscript.
Anhänge

Authors’ original submitted files for images

Below are the links to the authors’ original submitted files for images.
Literatur
1.
Zurück zum Zitat Gonda SJ, Li R: Principles of subcutaneous port placement. Tech Vasc Interv Radiol. 2011, 14: 198-203. 10.1053/j.tvir.2011.05.007.CrossRefPubMed Gonda SJ, Li R: Principles of subcutaneous port placement. Tech Vasc Interv Radiol. 2011, 14: 198-203. 10.1053/j.tvir.2011.05.007.CrossRefPubMed
2.
Zurück zum Zitat Kim HJ, Yun J, Kim HJ, Kim KH, Kim SH, Lee SC: Safety and effectiveness of central venous catheterization in patients with cancer: prospective observational study. J Korean Med Sci. 2010, 25: 1748-1753. 10.3346/jkms.2010.25.12.1748.PubMedCentralCrossRefPubMed Kim HJ, Yun J, Kim HJ, Kim KH, Kim SH, Lee SC: Safety and effectiveness of central venous catheterization in patients with cancer: prospective observational study. J Korean Med Sci. 2010, 25: 1748-1753. 10.3346/jkms.2010.25.12.1748.PubMedCentralCrossRefPubMed
3.
Zurück zum Zitat Wu CY, Fu JY, Feng PH, Liu YH, Wu CF, Kao TC: Risk factors and possible mechanisms of intravenous port catheter migration. Eur J Vasc Endovasc Surg. 2012, 44: 82-87. 10.1016/j.ejvs.2012.03.010.CrossRefPubMed Wu CY, Fu JY, Feng PH, Liu YH, Wu CF, Kao TC: Risk factors and possible mechanisms of intravenous port catheter migration. Eur J Vasc Endovasc Surg. 2012, 44: 82-87. 10.1016/j.ejvs.2012.03.010.CrossRefPubMed
4.
Zurück zum Zitat Kock HJ, Pietsch M, Krause U, Wilke H, Eigler FW: Implantable vascular access systems: experience in 1,500 patients with totally implanted central venous port systems. World J Surg. 1998, 22: 12-16. 10.1007/s002689900342.CrossRefPubMed Kock HJ, Pietsch M, Krause U, Wilke H, Eigler FW: Implantable vascular access systems: experience in 1,500 patients with totally implanted central venous port systems. World J Surg. 1998, 22: 12-16. 10.1007/s002689900342.CrossRefPubMed
5.
Zurück zum Zitat Poorter RL, Lauw FN, Bemelman WA, Bakker PJ, Taat CW, Veenhof CH: Complications of an implantable venous access device (Port-A-Cath) during intermittent continuous infusion of chemotherapy. Eur J Cancer. 1996, 32A: 2262-2266.CrossRefPubMed Poorter RL, Lauw FN, Bemelman WA, Bakker PJ, Taat CW, Veenhof CH: Complications of an implantable venous access device (Port-A-Cath) during intermittent continuous infusion of chemotherapy. Eur J Cancer. 1996, 32A: 2262-2266.CrossRefPubMed
6.
Zurück zum Zitat Yeste SL, Galbis Caravajal JM, Fuster Diana CA, Moledo EE: Protocol for the implantation of a venous access device (Port-A-Cath system): the complications and solutions found in 560 cases. Clin Transl Oncol. 2006, 8: 735-741. 10.1007/s12094-006-0120-y.CrossRef Yeste SL, Galbis Caravajal JM, Fuster Diana CA, Moledo EE: Protocol for the implantation of a venous access device (Port-A-Cath system): the complications and solutions found in 560 cases. Clin Transl Oncol. 2006, 8: 735-741. 10.1007/s12094-006-0120-y.CrossRef
7.
Zurück zum Zitat Lum PS, Soski M: Management of malpositioned central venous catheters. J Intraven Nurs. 1989, 12: 356-365.PubMed Lum PS, Soski M: Management of malpositioned central venous catheters. J Intraven Nurs. 1989, 12: 356-365.PubMed
8.
Zurück zum Zitat Biffi R, De BF, Orsi F, Pozzi S, Mauri S, Goldhirsch A: Totally implantable central venous access ports for long-term chemotherapy: a prospective study analyzing complications and costs of 333 devices with a minimum follow-up of 180 days. Ann Oncol. 1998, 9: 767-773. 10.1023/A:1008392423469.CrossRefPubMed Biffi R, De BF, Orsi F, Pozzi S, Mauri S, Goldhirsch A: Totally implantable central venous access ports for long-term chemotherapy: a prospective study analyzing complications and costs of 333 devices with a minimum follow-up of 180 days. Ann Oncol. 1998, 9: 767-773. 10.1023/A:1008392423469.CrossRefPubMed
9.
Zurück zum Zitat Binnebosel M, Grommes J, Junge K, Gobner S, Schumpelick V, Truong S: Internal jugular vein thrombosis presenting as a painful neck mass due to a spontaneous dislocated subclavian port catheter as long-term complication: a case report. Cases J. 2009, 2: 7991-10.4076/1757-1626-2-7991.PubMedCentralCrossRefPubMed Binnebosel M, Grommes J, Junge K, Gobner S, Schumpelick V, Truong S: Internal jugular vein thrombosis presenting as a painful neck mass due to a spontaneous dislocated subclavian port catheter as long-term complication: a case report. Cases J. 2009, 2: 7991-10.4076/1757-1626-2-7991.PubMedCentralCrossRefPubMed
10.
Zurück zum Zitat Collin GR, Ahmadinejad AS, Misse E: Spontaneous migration of subcutaneous central venous catheters. Am Surg. 1997, 63: 322-326.PubMed Collin GR, Ahmadinejad AS, Misse E: Spontaneous migration of subcutaneous central venous catheters. Am Surg. 1997, 63: 322-326.PubMed
11.
Zurück zum Zitat Bruninx G, Matte JC, VanWilder F, Delcour C: Catheter migration of a Port-A-Cath system. Cardiovasc Intervent Radiol. 1996, 19: 435-437. 10.1007/BF02577634.CrossRefPubMed Bruninx G, Matte JC, VanWilder F, Delcour C: Catheter migration of a Port-A-Cath system. Cardiovasc Intervent Radiol. 1996, 19: 435-437. 10.1007/BF02577634.CrossRefPubMed
12.
Zurück zum Zitat Wu PY, Yeh YC, Huang CH, Lau HP, Yeh HM: Spontaneous migration of a Port-A-Cath catheter into ipsilateral jugular vein in two patients with severe cough. Ann Vasc Surg. 2005, 19: 734-736. 10.1007/s10016-005-4638-1.CrossRefPubMed Wu PY, Yeh YC, Huang CH, Lau HP, Yeh HM: Spontaneous migration of a Port-A-Cath catheter into ipsilateral jugular vein in two patients with severe cough. Ann Vasc Surg. 2005, 19: 734-736. 10.1007/s10016-005-4638-1.CrossRefPubMed
13.
Zurück zum Zitat Klein HO, Segni ED, Kaplinsky E: Unsuspected cerebral perfusion: a complication of the use of a central venous pressure catheter. Chest. 1978, 74: 109-110. 10.1378/chest.74.1.109.CrossRefPubMed Klein HO, Segni ED, Kaplinsky E: Unsuspected cerebral perfusion: a complication of the use of a central venous pressure catheter. Chest. 1978, 74: 109-110. 10.1378/chest.74.1.109.CrossRefPubMed
14.
Zurück zum Zitat Souter RG, Mitchell A: Spreading cortical venous thrombosis due to infusion of hyperosmolar solution into the internal jugular vein. Br Med J (Clin Res Ed). 1982, 285: 935-936. 10.1136/bmj.285.6346.935.CrossRef Souter RG, Mitchell A: Spreading cortical venous thrombosis due to infusion of hyperosmolar solution into the internal jugular vein. Br Med J (Clin Res Ed). 1982, 285: 935-936. 10.1136/bmj.285.6346.935.CrossRef
15.
Zurück zum Zitat Gilner LI: The ‘ear-gurgling’ sign. N Engl J Med. 1977, 296: 1301-PubMed Gilner LI: The ‘ear-gurgling’ sign. N Engl J Med. 1977, 296: 1301-PubMed
16.
Zurück zum Zitat Baskin KM, Jimenez RM, Cahill AM, Jawad AF, Towbin RB: Cavoatrial junction and central venous anatomy: implications for central venous access tip position. J Vasc Interv Radiol. 2008, 19: 359-365. 10.1016/j.jvir.2007.09.005.CrossRefPubMed Baskin KM, Jimenez RM, Cahill AM, Jawad AF, Towbin RB: Cavoatrial junction and central venous anatomy: implications for central venous access tip position. J Vasc Interv Radiol. 2008, 19: 359-365. 10.1016/j.jvir.2007.09.005.CrossRefPubMed
17.
Zurück zum Zitat Nagel SN, Teichgraber UK, Kausche S, Lehmann A: Satisfaction and quality of life: a survey-based assessment in patients with a totally implantable venous port system. Eur J Cancer Care (Engl). 2012, 21: 197-204. 10.1111/j.1365-2354.2011.01275.x.CrossRef Nagel SN, Teichgraber UK, Kausche S, Lehmann A: Satisfaction and quality of life: a survey-based assessment in patients with a totally implantable venous port system. Eur J Cancer Care (Engl). 2012, 21: 197-204. 10.1111/j.1365-2354.2011.01275.x.CrossRef
18.
Zurück zum Zitat Yildizeli B, Lacin T, Batirel HF, Yuksel M: Complications and management of long-term central venous access catheters and ports. J Vasc Access. 2004, 5: 174-178.PubMed Yildizeli B, Lacin T, Batirel HF, Yuksel M: Complications and management of long-term central venous access catheters and ports. J Vasc Access. 2004, 5: 174-178.PubMed
19.
Zurück zum Zitat Collier PE, Blocker SH, Graff DM, Doyle P: Cardiac tamponade from central venous catheters. Am J Surg. 1998, 176: 212-214. 10.1016/S0002-9610(98)00171-8.CrossRefPubMed Collier PE, Blocker SH, Graff DM, Doyle P: Cardiac tamponade from central venous catheters. Am J Surg. 1998, 176: 212-214. 10.1016/S0002-9610(98)00171-8.CrossRefPubMed
20.
Zurück zum Zitat Rasuli P, Hammond DI, Peterkin IR: Spontaneous intrajugular migration of long-term central venous access catheters. Radiology. 1992, 182: 822-824.CrossRefPubMed Rasuli P, Hammond DI, Peterkin IR: Spontaneous intrajugular migration of long-term central venous access catheters. Radiology. 1992, 182: 822-824.CrossRefPubMed
21.
Zurück zum Zitat Forauer AR, Theoharis CG, Dasika NL: Jugular vein catheter placement: histologic features and development of catheter-related (fibrin) sheaths in a swine model. Radiology. 2006, 240: 427-434. 10.1148/radiol.2402031129.CrossRefPubMed Forauer AR, Theoharis CG, Dasika NL: Jugular vein catheter placement: histologic features and development of catheter-related (fibrin) sheaths in a swine model. Radiology. 2006, 240: 427-434. 10.1148/radiol.2402031129.CrossRefPubMed
22.
Zurück zum Zitat Gebauer B, Teichgraber UK, Podrabsky P, Werk M, Hanninen EL, Felix R: Radiological interventions for correction of central venous port catheter migrations. Cardiovasc Intervent Radiol. 2007, 30: 668-674. 10.1007/s00270-007-9073-y.CrossRefPubMed Gebauer B, Teichgraber UK, Podrabsky P, Werk M, Hanninen EL, Felix R: Radiological interventions for correction of central venous port catheter migrations. Cardiovasc Intervent Radiol. 2007, 30: 668-674. 10.1007/s00270-007-9073-y.CrossRefPubMed
23.
Zurück zum Zitat Ahn KS, Yoo K, Cha IH, Seo TS: Spontaneously migrated tip of an implantable port catheter into the axillary vein in a patient with severe cough and the subsequent intervention to reposition it. Korean J Radiol. 2008, 9 (Suppl): S81-S84. 10.3348/kjr.2008.9.s.s81.PubMedCentralCrossRefPubMed Ahn KS, Yoo K, Cha IH, Seo TS: Spontaneously migrated tip of an implantable port catheter into the axillary vein in a patient with severe cough and the subsequent intervention to reposition it. Korean J Radiol. 2008, 9 (Suppl): S81-S84. 10.3348/kjr.2008.9.s.s81.PubMedCentralCrossRefPubMed
Metadaten
Titel
Risk factors for venous port migration in a single institute in Taiwan
verfasst von
Wen-Chieh Fan
Cheng-Han Wu
Ming-Ju Tsai
Ying-Ming Tsai
Hsu-Liang Chang
Jen-Yu Hung
Pei-Huan Chen
Chih-Jen Yang
Publikationsdatum
01.12.2014
Verlag
BioMed Central
Erschienen in
World Journal of Surgical Oncology / Ausgabe 1/2014
Elektronische ISSN: 1477-7819
DOI
https://doi.org/10.1186/1477-7819-12-15

Weitere Artikel der Ausgabe 1/2014

World Journal of Surgical Oncology 1/2014 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.