Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 7/2018

15.03.2018 | Orthopaedic Surgery

Role of an anatomically contoured plate and metal block for balanced stability between the implant and lateral hinge in open-wedge high-tibial osteotomy

verfasst von: Young Woong Jang, DoHyung Lim, Hansol Seo, Myung Chul Lee, O-Sung Lee, Yong Seuk Lee

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 7/2018

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Open-wedge high tibial osteotomy (OWHTO) is a well-established surgical option for medial compartment osteoarthritis of the varus knee. The initial strength of the fixation plate is critical for successful correction maintenance and healing of the osteotomy site. This study was conducted to verify if a newly designed anatomical plate (LCfit) improves the stability of both the medial implant and lateral hinge area, as well as to evaluate how the metal block contributes to both medial and lateral stability.

Materials and methods

A finite element (FE) tibial model was combined with TomoFix plate, a LCfit plate with and without a metal block. Data analysis was conducted to evaluate the balanced stability, which refers to the enforced lateral stability resulting from redistribution of overall stress. We assessed the balanced stability of the medial implant and lateral hinge area in three cases using the same Sawbones and loads using the tibia FE model.

Results

The LCfit plate reduced stress by 23.1% at the lateral hinge compared to the TomoFix plate (TomoFix vs. LCfit: 34.2 ± 23.3 MPa vs. 26.3 ± 17.5 MPa). The LCfit plate with a metal block reduced stress by 40.1% at the medial plate (210.1 ± 64.2 MPa vs. 125.8 ± 65.7 MPa) and by 31.2% (26.3 ± 17.5 MPa vs. 18.1 ± 12.1 MPa) at the lateral hinge area compared to the reduction using the LCfit plate without a metal block.

Conclusion

The newly designed fixation system for OWHTO balanced the overall stress distribution and reduced stress at the lateral hinge area compared to that using a conventional fixation system. The addition of the metal block showed additional benefits for balanced stability between the medial implant and lateral hinge area. However, this conclusion could only be drawn using the FE model in this study. Therefore, further clinical studies are necessary to reveal the clinical effect of reduced lateral stress on the occurrence of the lateral hinge fracture and the biologic effect of the metal block on the healing of the medial cortex.
Literatur
1.
Zurück zum Zitat Agneskirchner JD, Freiling D, Hurschler C, Lobenhoffer P (2006) Primary stability of four different implants for opening wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 14:291–300CrossRefPubMed Agneskirchner JD, Freiling D, Hurschler C, Lobenhoffer P (2006) Primary stability of four different implants for opening wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 14:291–300CrossRefPubMed
2.
Zurück zum Zitat Blecha LD, Zambelli PY, Ramaniraka NA, Bourban PE, Manson JA, Pioletti DP (2005) How plate positioning impacts the biomechanics of the open wedge tibial osteotomy; a finite element analysis. Comput Methods Biomech Biomed Engin 8:307–313CrossRefPubMed Blecha LD, Zambelli PY, Ramaniraka NA, Bourban PE, Manson JA, Pioletti DP (2005) How plate positioning impacts the biomechanics of the open wedge tibial osteotomy; a finite element analysis. Comput Methods Biomech Biomed Engin 8:307–313CrossRefPubMed
3.
Zurück zum Zitat Brosset T, Pasquier G, Migaud H, Gougeon F (2011) Opening wedge high tibial osteotomy performed without filling the defect but with locking plate fixation (TomoFix) and early weight-bearing: prospective evaluation of bone union, precision and maintenance of correction in 51 cases. Orthop Traumatol Surg Res 97:705–711CrossRefPubMed Brosset T, Pasquier G, Migaud H, Gougeon F (2011) Opening wedge high tibial osteotomy performed without filling the defect but with locking plate fixation (TomoFix) and early weight-bearing: prospective evaluation of bone union, precision and maintenance of correction in 51 cases. Orthop Traumatol Surg Res 97:705–711CrossRefPubMed
4.
Zurück zum Zitat Cotic M, Vogt S, Hinterwimmer S, Feucht MJ, Slotta-Huspenina J, Schuster T, Imhoff AB (2014) A matched-pair comparison of two different locking plates for valgus-producing medial open-wedge high tibial osteotomy: peek-carbon composite plate versus titanium plate. Knee Surg Sports Traumatol Arthrosc 23(7):2032–2040CrossRefPubMed Cotic M, Vogt S, Hinterwimmer S, Feucht MJ, Slotta-Huspenina J, Schuster T, Imhoff AB (2014) A matched-pair comparison of two different locking plates for valgus-producing medial open-wedge high tibial osteotomy: peek-carbon composite plate versus titanium plate. Knee Surg Sports Traumatol Arthrosc 23(7):2032–2040CrossRefPubMed
5.
Zurück zum Zitat Dexel J, Fritzsche H, Beyer F, Harman MK, Lutzner J (2017) Open-wedge high tibial osteotomy: incidence of lateral cortex fractures and influence of fixation device on osteotomy healing. Knee Surg Sports Traumatol Arthrosc 25:832–837CrossRefPubMed Dexel J, Fritzsche H, Beyer F, Harman MK, Lutzner J (2017) Open-wedge high tibial osteotomy: incidence of lateral cortex fractures and influence of fixation device on osteotomy healing. Knee Surg Sports Traumatol Arthrosc 25:832–837CrossRefPubMed
6.
Zurück zum Zitat Gaasbeek RD, Nicolaas L, Rijnberg WJ, van Loon CJ, van Kampen A (2010) Correction accuracy and collateral laxity in open versus closed wedge high tibial osteotomy. A one-year randomised controlled study. Int Orthop 34:201–207CrossRefPubMed Gaasbeek RD, Nicolaas L, Rijnberg WJ, van Loon CJ, van Kampen A (2010) Correction accuracy and collateral laxity in open versus closed wedge high tibial osteotomy. A one-year randomised controlled study. Int Orthop 34:201–207CrossRefPubMed
7.
Zurück zum Zitat Gardner MP, Chong AC, Pollock AG, Wooley PH (2010) Mechanical evaluation of large-size fourth-generation composite femur and tibia models. Ann Biomed Eng 38:613–620CrossRefPubMed Gardner MP, Chong AC, Pollock AG, Wooley PH (2010) Mechanical evaluation of large-size fourth-generation composite femur and tibia models. Ann Biomed Eng 38:613–620CrossRefPubMed
8.
Zurück zum Zitat Golovakhsmall a CML, Orljanski W, Benedetto KP, Panchenko S, Buchler P, Henle P, Aghayev E (2014) Comparison of theoretical fixation stability of three devices employed in medial opening wedge high tibial osteotomy: a finite element analysis. BMC Musculoskelet Disord 15:230CrossRef Golovakhsmall a CML, Orljanski W, Benedetto KP, Panchenko S, Buchler P, Henle P, Aghayev E (2014) Comparison of theoretical fixation stability of three devices employed in medial opening wedge high tibial osteotomy: a finite element analysis. BMC Musculoskelet Disord 15:230CrossRef
9.
Zurück zum Zitat Han SB, Bae JH, Lee SJ, Jung TG, Kim KH, Kwon JH, Nha KW (2014) Biomechanical properties of a new anatomical locking metal block plate for opening wedge high tibial osteotomy: uniplane osteotomy. Knee Surg Relat Res 26:155–161CrossRefPubMedPubMedCentral Han SB, Bae JH, Lee SJ, Jung TG, Kim KH, Kwon JH, Nha KW (2014) Biomechanical properties of a new anatomical locking metal block plate for opening wedge high tibial osteotomy: uniplane osteotomy. Knee Surg Relat Res 26:155–161CrossRefPubMedPubMedCentral
10.
Zurück zum Zitat Han SB, Lee DH, Shetty GM, Chae DJ, Song JG, Nha KW (2013) A “safe zone” in medial open-wedge high tibia osteotomy to prevent lateral cortex fracture. Knee Surg Sports Traumatol Arthrosc 21:90–95CrossRefPubMed Han SB, Lee DH, Shetty GM, Chae DJ, Song JG, Nha KW (2013) A “safe zone” in medial open-wedge high tibia osteotomy to prevent lateral cortex fracture. Knee Surg Sports Traumatol Arthrosc 21:90–95CrossRefPubMed
11.
Zurück zum Zitat Hoffler CE, Moore KE, Kozloff K, Zysset PK, Goldstein SA (2000) Age, gender, and bone lamellae elastic moduli. J Orthop Res 18:432–437CrossRefPubMed Hoffler CE, Moore KE, Kozloff K, Zysset PK, Goldstein SA (2000) Age, gender, and bone lamellae elastic moduli. J Orthop Res 18:432–437CrossRefPubMed
12.
Zurück zum Zitat Kolb W, Guhlmann H, Windisch C, Kolb K, Koller H, Grutzner P (2009) Opening-wedge high tibial osteotomy with a locked low-profile plate. J Bone Joint Surg Am 91:2581–2588CrossRefPubMed Kolb W, Guhlmann H, Windisch C, Kolb K, Koller H, Grutzner P (2009) Opening-wedge high tibial osteotomy with a locked low-profile plate. J Bone Joint Surg Am 91:2581–2588CrossRefPubMed
13.
Zurück zum Zitat Krone R, Schuster P (2006) An investigation on the importance of material anisotropy in finite-element modeling of the human femur. SAE International 2006-01-0064 Krone R, Schuster P (2006) An investigation on the importance of material anisotropy in finite-element modeling of the human femur. SAE International 2006-01-0064
14.
Zurück zum Zitat Kuiper JH, Huiskes R (1996) Friction and stem stiffness affect dynamic interface motion in total hip replacement. J Orthop Res 14:36–43CrossRefPubMed Kuiper JH, Huiskes R (1996) Friction and stem stiffness affect dynamic interface motion in total hip replacement. J Orthop Res 14:36–43CrossRefPubMed
15.
Zurück zum Zitat Lee YS, Kang JY, Lee MC, Elazab A, Choi UH, Kang SG, Lee KJ, Lee S (2017) Osteotomy configuration of the proximal wedge and analysis of the affecting factors in the medial open-wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 25:793–799CrossRefPubMed Lee YS, Kang JY, Lee MC, Elazab A, Choi UH, Kang SG, Lee KJ, Lee S (2017) Osteotomy configuration of the proximal wedge and analysis of the affecting factors in the medial open-wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 25:793–799CrossRefPubMed
16.
Zurück zum Zitat Li G, Lopez O, Rubash H (2001) Variability of a three-dimensional finite element model constructed using magnetic resonance images of a knee for joint contact stress analysis. J Biomech Eng 123:341–346CrossRefPubMed Li G, Lopez O, Rubash H (2001) Variability of a three-dimensional finite element model constructed using magnetic resonance images of a knee for joint contact stress analysis. J Biomech Eng 123:341–346CrossRefPubMed
17.
Zurück zum Zitat Luo CA, Hwa SY, Lin SC, Chen CM, Tseng CS (2015) Placement-induced effects on high tibial osteotomized construct—biomechanical tests and finite-element analyses. BMC Musculoskelet Disord 16:235CrossRefPubMedPubMedCentral Luo CA, Hwa SY, Lin SC, Chen CM, Tseng CS (2015) Placement-induced effects on high tibial osteotomized construct—biomechanical tests and finite-element analyses. BMC Musculoskelet Disord 16:235CrossRefPubMedPubMedCentral
18.
Zurück zum Zitat Luo CA, Lin SC, Hwa SY, Chen CM, Tseng CS (2015) Biomechanical effects of plate area and locking screw on medial open tibial osteotomy. Comput Methods Biomech Biomed Eng 18:1263–1271CrossRef Luo CA, Lin SC, Hwa SY, Chen CM, Tseng CS (2015) Biomechanical effects of plate area and locking screw on medial open tibial osteotomy. Comput Methods Biomech Biomed Eng 18:1263–1271CrossRef
19.
Zurück zum Zitat Madry H, Goebel L, Hoffmann A, Duck K, Gerich T, Seil R, Tschernig T, Pape D (2016) Surgical anatomy of medial open-wedge high tibial osteotomy: crucial steps and pitfalls. Knee Surg Sports Traumatol Arthrosc 25(12):3661–3669CrossRefPubMed Madry H, Goebel L, Hoffmann A, Duck K, Gerich T, Seil R, Tschernig T, Pape D (2016) Surgical anatomy of medial open-wedge high tibial osteotomy: crucial steps and pitfalls. Knee Surg Sports Traumatol Arthrosc 25(12):3661–3669CrossRefPubMed
20.
Zurück zum Zitat Martin R, Birmingham TB, Willits K, Litchfield R, Lebel ME, Giffin JR (2014) Adverse event rates and classifications in medial opening wedge high tibial osteotomy. Am J Sports Med 42:1118–1126CrossRefPubMed Martin R, Birmingham TB, Willits K, Litchfield R, Lebel ME, Giffin JR (2014) Adverse event rates and classifications in medial opening wedge high tibial osteotomy. Am J Sports Med 42:1118–1126CrossRefPubMed
21.
Zurück zum Zitat Meidinger G, Imhoff AB, Paul J, Kirchhoff C, Sauerschnig M, Hinterwimmer S (2011) May smokers and overweight patients be treated with a medial open-wedge HTO? Risk factors for non-union. Knee Surg Sports Traumatol Arthrosc 19:333–339CrossRefPubMed Meidinger G, Imhoff AB, Paul J, Kirchhoff C, Sauerschnig M, Hinterwimmer S (2011) May smokers and overweight patients be treated with a medial open-wedge HTO? Risk factors for non-union. Knee Surg Sports Traumatol Arthrosc 19:333–339CrossRefPubMed
22.
Zurück zum Zitat Miller BS, Dorsey WO, Bryant CR, Austin JC (2005) The effect of lateral cortex disruption and repair on the stability of the medial opening wedge high tibial osteotomy. Am J Sports Med 33:1552–1557CrossRefPubMed Miller BS, Dorsey WO, Bryant CR, Austin JC (2005) The effect of lateral cortex disruption and repair on the stability of the medial opening wedge high tibial osteotomy. Am J Sports Med 33:1552–1557CrossRefPubMed
23.
Zurück zum Zitat Miller BS, Downie B, McDonough EB, Wojtys EM (2009) Complications after medial opening wedge high tibial osteotomy. Arthroscopy 25:639–646CrossRefPubMed Miller BS, Downie B, McDonough EB, Wojtys EM (2009) Complications after medial opening wedge high tibial osteotomy. Arthroscopy 25:639–646CrossRefPubMed
24.
Zurück zum Zitat Nawas HT, Vansadia DV, Heltsley JR, Suri M, Montgomery S, Jones DG (2016) Factors Affecting the union of opening wedge high tibial osteotomy using a titanium wedge plate. Ochsner J 16:464–470PubMedPubMedCentral Nawas HT, Vansadia DV, Heltsley JR, Suri M, Montgomery S, Jones DG (2016) Factors Affecting the union of opening wedge high tibial osteotomy using a titanium wedge plate. Ochsner J 16:464–470PubMedPubMedCentral
25.
Zurück zum Zitat Nelissen EM, van Langelaan EJ, Nelissen RG (2010) Stability of medial opening wedge high tibial osteotomy: a failure analysis. Int Orthop 34:217–223CrossRefPubMed Nelissen EM, van Langelaan EJ, Nelissen RG (2010) Stability of medial opening wedge high tibial osteotomy: a failure analysis. Int Orthop 34:217–223CrossRefPubMed
26.
Zurück zum Zitat Noyes FR, Mayfield W, Barber-Westin SD, Albright JC, Heckmann TP (2006) Opening wedge high tibial osteotomy: an operative technique and rehabilitation program to decrease complications and promote early union and function. Am J Sports Med 34:1262–1273CrossRefPubMed Noyes FR, Mayfield W, Barber-Westin SD, Albright JC, Heckmann TP (2006) Opening wedge high tibial osteotomy: an operative technique and rehabilitation program to decrease complications and promote early union and function. Am J Sports Med 34:1262–1273CrossRefPubMed
27.
Zurück zum Zitat Raja Izaham RM, Abdul Kadir MR, Abdul Rashid AH, Hossain MG, Kamarul T (2012) Finite element analysis of Puddu and Tomofix plate fixation for open wedge high tibial osteotomy. Injury 43:898–902CrossRefPubMed Raja Izaham RM, Abdul Kadir MR, Abdul Rashid AH, Hossain MG, Kamarul T (2012) Finite element analysis of Puddu and Tomofix plate fixation for open wedge high tibial osteotomy. Injury 43:898–902CrossRefPubMed
28.
Zurück zum Zitat Rancourt D, Shirazi-Adl A, Drouin G, Paiement G (1990) Friction properties of the interface between porous-surfaced metals and tibial cancellous bone. J Biomed Mater Res 24:1503–1519CrossRefPubMed Rancourt D, Shirazi-Adl A, Drouin G, Paiement G (1990) Friction properties of the interface between porous-surfaced metals and tibial cancellous bone. J Biomed Mater Res 24:1503–1519CrossRefPubMed
29.
Zurück zum Zitat Reilly DT, Burstein AH (1975) The elastic and ultimate properties of compact bone tissue. J Biomech 8:393–405CrossRefPubMed Reilly DT, Burstein AH (1975) The elastic and ultimate properties of compact bone tissue. J Biomech 8:393–405CrossRefPubMed
30.
Zurück zum Zitat Schroter S, Gonser CE, Konstantinidis L, Helwig P, Albrecht D (2011) High complication rate after biplanar open wedge high tibial osteotomy stabilized with a new spacer plate (position HTO plate) without bone substitute. Arthroscopy 27:644–652CrossRefPubMed Schroter S, Gonser CE, Konstantinidis L, Helwig P, Albrecht D (2011) High complication rate after biplanar open wedge high tibial osteotomy stabilized with a new spacer plate (position HTO plate) without bone substitute. Arthroscopy 27:644–652CrossRefPubMed
31.
Zurück zum Zitat Smith JO, Wilson AJ, Thomas NP (2013) Osteotomy around the knee: evolution, principles and results. Knee Surg Sports Traumatol Arthrosc 21:3–22CrossRefPubMed Smith JO, Wilson AJ, Thomas NP (2013) Osteotomy around the knee: evolution, principles and results. Knee Surg Sports Traumatol Arthrosc 21:3–22CrossRefPubMed
32.
Zurück zum Zitat Staubli AE, De Simoni C, Babst R, Lobenhoffer P (2003) TomoFix: a new LCP-concept for open wedge osteotomy of the medial proximal tibia–early results in 92 cases. Injury 34(Suppl 2):B55–62CrossRefPubMed Staubli AE, De Simoni C, Babst R, Lobenhoffer P (2003) TomoFix: a new LCP-concept for open wedge osteotomy of the medial proximal tibia–early results in 92 cases. Injury 34(Suppl 2):B55–62CrossRefPubMed
33.
Zurück zum Zitat Takeuchi R, Ishikawa H, Kumagai K, Yamaguchi Y, Chiba N, Akamatsu Y, Saito T (2012) Fractures around the lateral cortical hinge after a medial opening-wedge high tibial osteotomy: a new classification of lateral hinge fracture. Arthroscopy 28:85–94CrossRefPubMed Takeuchi R, Ishikawa H, Kumagai K, Yamaguchi Y, Chiba N, Akamatsu Y, Saito T (2012) Fractures around the lateral cortical hinge after a medial opening-wedge high tibial osteotomy: a new classification of lateral hinge fracture. Arthroscopy 28:85–94CrossRefPubMed
34.
Zurück zum Zitat Taylor WR, Heller MO, Bergmann G, Duda GN (2004) Tibio-femoral loading during human gait and stair climbing. J Orthop Res 22:625–632CrossRefPubMed Taylor WR, Heller MO, Bergmann G, Duda GN (2004) Tibio-femoral loading during human gait and stair climbing. J Orthop Res 22:625–632CrossRefPubMed
35.
Zurück zum Zitat Turkmen F, Kacira BK, Ozkaya M, Erkocak OF, Acar MA, Ozer M, Toker S, Demir T (2016) Comparison of monoplanar versus biplanar medial opening-wedge high tibial osteotomy techniques for preventing lateral cortex fracture. Knee Surg Sports Traumatol Arthrosc 25(9):2914–2920CrossRefPubMed Turkmen F, Kacira BK, Ozkaya M, Erkocak OF, Acar MA, Ozer M, Toker S, Demir T (2016) Comparison of monoplanar versus biplanar medial opening-wedge high tibial osteotomy techniques for preventing lateral cortex fracture. Knee Surg Sports Traumatol Arthrosc 25(9):2914–2920CrossRefPubMed
36.
Zurück zum Zitat Valkering KP, van den Bekerom MP, Kappelhoff FM, Albers GH (2009) Complications after tomofix medial opening wedge high tibial osteotomy. J Knee Surg 22:218–225CrossRefPubMed Valkering KP, van den Bekerom MP, Kappelhoff FM, Albers GH (2009) Complications after tomofix medial opening wedge high tibial osteotomy. J Knee Surg 22:218–225CrossRefPubMed
37.
Zurück zum Zitat Vena G, D’Adamio S, Amendola A (2013) Complications of osteotomies about the knee. Sports Med Arthrosc 21:113–120CrossRefPubMed Vena G, D’Adamio S, Amendola A (2013) Complications of osteotomies about the knee. Sports Med Arthrosc 21:113–120CrossRefPubMed
38.
Zurück zum Zitat Viceconti M, Muccini R, Bernakiewicz M, Baleani M, Cristofolini L (2000) Large-sliding contact elements accurately predict levels of bone}implant micromotion relevant to osseointegration. J Biomech 33:1611–1618CrossRefPubMed Viceconti M, Muccini R, Bernakiewicz M, Baleani M, Cristofolini L (2000) Large-sliding contact elements accurately predict levels of bone}implant micromotion relevant to osseointegration. J Biomech 33:1611–1618CrossRefPubMed
39.
Zurück zum Zitat Yacobucci GN, Cocking MR (2008) Union of medial opening-wedge high tibial osteotomy using a corticocancellous proximal tibial wedge allograft. Am J Sports Med 36:713–719CrossRefPubMed Yacobucci GN, Cocking MR (2008) Union of medial opening-wedge high tibial osteotomy using a corticocancellous proximal tibial wedge allograft. Am J Sports Med 36:713–719CrossRefPubMed
40.
Zurück zum Zitat Yoo OS, Lee YS, Lee MC, Elazab A, Choi DG, Jang YW (2016) Evaluation of the screw position and angle using a post-contoured plate in the open wedge high tibial osteotomy according to the correction degree and surgical technique. Clin Biomech (Bristol Avon) 35:111–115CrossRef Yoo OS, Lee YS, Lee MC, Elazab A, Choi DG, Jang YW (2016) Evaluation of the screw position and angle using a post-contoured plate in the open wedge high tibial osteotomy according to the correction degree and surgical technique. Clin Biomech (Bristol Avon) 35:111–115CrossRef
41.
Zurück zum Zitat Zaki SH, Rae PJ (2009) High tibial valgus osteotomy using the Tomofix plate–medium-term results in young patients. Acta Orthop Belg 75:360–367PubMed Zaki SH, Rae PJ (2009) High tibial valgus osteotomy using the Tomofix plate–medium-term results in young patients. Acta Orthop Belg 75:360–367PubMed
Metadaten
Titel
Role of an anatomically contoured plate and metal block for balanced stability between the implant and lateral hinge in open-wedge high-tibial osteotomy
verfasst von
Young Woong Jang
DoHyung Lim
Hansol Seo
Myung Chul Lee
O-Sung Lee
Yong Seuk Lee
Publikationsdatum
15.03.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 7/2018
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-018-2918-9

Weitere Artikel der Ausgabe 7/2018

Archives of Orthopaedic and Trauma Surgery 7/2018 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.