Abstract

Purpose

This study aims to find a safe and easy-to-perform strategy for lumbar pedicle screw insertion based on anatomical landmarks.

Methods

From March 2011 to January 2012, 74 patients underwent posterior lumbar interbody fusion or transforaminal lumbar interbody fusion using the new-designed screw insertion technique. During the operation, the entry site for screw insertion was on the outer edge of the superior facet joint, 4 mm downward from upper border of processus transversus. A connecting line between superior and inferior facet joints was used to determine the direction of screw insertion. Postoperative radiograph and computed tomography (CT) were taken routinely to show the position of the screws. Functional outcomes were evaluated using Oswestry Disability Index score, Japanese Orthopedic Association score, and Visual Analogue Scale, respectively.

Results

Sixty-two patients (27 males and 35 females, average age 58.95 ± 8.45) finished the follow-up visit with an average of 46.03 months (36–60). The mean operation time and the blood loss were 169.60 ± 41.21 min and 489.52 ± 189.38 ml, respectively. A total of 274 pedicle screws were inserted following the new technique. According to Lothar Wiesner’s classification, 11 screws (4.01%) caused minor violation into wall, two screws (0.73%) caused moderate violation, and other screws were in proper position.

Conclusion

A new-designed surgical strategy for pedicle screw insertion of lumbar spine was introduced and performed, which featured a series of original and easily distinguished landmarks. Clinical application demonstrated the safety and effectiveness of this novel technique for pedicle screw insertion.
Literatur
1.
Zurück zum Zitat Harrington PR, Tullos HS (1969) Reduction of severe spondylolisthesis in children. South Med J 62(1):1–7CrossRefPubMed Harrington PR, Tullos HS (1969) Reduction of severe spondylolisthesis in children. South Med J 62(1):1–7CrossRefPubMed
2.
Zurück zum Zitat Roy-Camille R, Saillant G, Mazel C (1986) Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop Relat Res 203:7–17 Roy-Camille R, Saillant G, Mazel C (1986) Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop Relat Res 203:7–17
3.
Zurück zum Zitat Magerl FP (1984) Stabilization of the lower thoracic and lumbar spine with external skeletal fixation. Clin Orthop Relat Res 189:125–141 Magerl FP (1984) Stabilization of the lower thoracic and lumbar spine with external skeletal fixation. Clin Orthop Relat Res 189:125–141
4.
Zurück zum Zitat Weinstein JN, Spratt KF, Spengler D, Brick C, Reid S (1988) Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine (Phila Pa 1976) 13:1012–1018CrossRef Weinstein JN, Spratt KF, Spengler D, Brick C, Reid S (1988) Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine (Phila Pa 1976) 13:1012–1018CrossRef
5.
Zurück zum Zitat Silbermann J, Riese F, Allam Y, Reichert T, Koeppert H, Gutberlet M (2011) Computer tomography assessment of pedicle screw placement in lumbar and sacral spine: comparison between free-hand and O-arm based navigation techniques. Eur Spine J 20:875–881CrossRefPubMedPubMedCentral Silbermann J, Riese F, Allam Y, Reichert T, Koeppert H, Gutberlet M (2011) Computer tomography assessment of pedicle screw placement in lumbar and sacral spine: comparison between free-hand and O-arm based navigation techniques. Eur Spine J 20:875–881CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Castro WH, Halm H, Jerosch J, Malms J, Steinbeck J, Blasius S (1996) Accuracy of pedicle screw placement in lumbar vertebrae. Spine (Phila Pa 1976) 21:1320–1324CrossRef Castro WH, Halm H, Jerosch J, Malms J, Steinbeck J, Blasius S (1996) Accuracy of pedicle screw placement in lumbar vertebrae. Spine (Phila Pa 1976) 21:1320–1324CrossRef
7.
Zurück zum Zitat Jerosch J, Malms J, Castro WH, Wagner R, Wiesner L (1992) Accuracy of pedicle screws following instrumented dorsal fusion of the lumbar spine. Z Orthop Ihre Grenzgeb 130:479–483CrossRefPubMed Jerosch J, Malms J, Castro WH, Wagner R, Wiesner L (1992) Accuracy of pedicle screws following instrumented dorsal fusion of the lumbar spine. Z Orthop Ihre Grenzgeb 130:479–483CrossRefPubMed
8.
Zurück zum Zitat Gelalis ID, Paschos NK, Pakos EE, Politis AN, Arnaoutoglou CM, Karageorgos AC, Ploumis A, Xenakis TA (2012) Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques. Eur Spine J 21:247–255CrossRefPubMed Gelalis ID, Paschos NK, Pakos EE, Politis AN, Arnaoutoglou CM, Karageorgos AC, Ploumis A, Xenakis TA (2012) Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques. Eur Spine J 21:247–255CrossRefPubMed
9.
Zurück zum Zitat Parker SL, McGirt MJ, Farber SH, Amin AG, Rick AM, Suk I, Bydon A, Sciubba DM, Wolinsky JP, Gokaslan ZL, Witham TF (2011) Accuracy of free-hand pedicle screws in the thoracic and lumbar spine: analysis of 6816 consecutive screws. Neurosurgery 68:170–178; discussion 178CrossRefPubMed Parker SL, McGirt MJ, Farber SH, Amin AG, Rick AM, Suk I, Bydon A, Sciubba DM, Wolinsky JP, Gokaslan ZL, Witham TF (2011) Accuracy of free-hand pedicle screws in the thoracic and lumbar spine: analysis of 6816 consecutive screws. Neurosurgery 68:170–178; discussion 178CrossRefPubMed
10.
Zurück zum Zitat Lotfinia I, Sayahmelli S, Gavami M (2010) Postoperative computed tomography assessment of pedicle screw placement accuracy. Turk Neurosurg 20(4):500–507PubMed Lotfinia I, Sayahmelli S, Gavami M (2010) Postoperative computed tomography assessment of pedicle screw placement accuracy. Turk Neurosurg 20(4):500–507PubMed
11.
Zurück zum Zitat Amato V, Giannachi L, Irace C, Corona C (2010) Accuracy of pedicle screw placement in the lumbosacral spine using conventional technique: computed tomography postoperative assessment in 102 consecutive patients. J Neurosurg Spine 12:306–313CrossRefPubMed Amato V, Giannachi L, Irace C, Corona C (2010) Accuracy of pedicle screw placement in the lumbosacral spine using conventional technique: computed tomography postoperative assessment in 102 consecutive patients. J Neurosurg Spine 12:306–313CrossRefPubMed
12.
Zurück zum Zitat Lonstein JE, Denis F, Perra JH, Pinto MR, Smith MD, Winter RB (1999) Complications associated with pedicle screws. J Bone Joint Surg Am 81:1519–1528CrossRefPubMed Lonstein JE, Denis F, Perra JH, Pinto MR, Smith MD, Winter RB (1999) Complications associated with pedicle screws. J Bone Joint Surg Am 81:1519–1528CrossRefPubMed
13.
Zurück zum Zitat Weise L, Suess O, Picht T, Kombos T (2008) Transpedicular screw fixation in the thoracic and lumbar spine with a novel cannulated polyaxial screw system. Med Devices (Auckl) 1:33–39 Weise L, Suess O, Picht T, Kombos T (2008) Transpedicular screw fixation in the thoracic and lumbar spine with a novel cannulated polyaxial screw system. Med Devices (Auckl) 1:33–39
14.
Zurück zum Zitat Rivet DJ, Jeck D, Brennan J, Epstein A, Lauryssen C (2004) Clinical outcomes and complications associated with pedicle screw fixation-augmented lumbar interbody fusion. J Neurosurg Spine 1:261–266CrossRefPubMed Rivet DJ, Jeck D, Brennan J, Epstein A, Lauryssen C (2004) Clinical outcomes and complications associated with pedicle screw fixation-augmented lumbar interbody fusion. J Neurosurg Spine 1:261–266CrossRefPubMed
16.
Zurück zum Zitat Amiot LP, Labelle H, DeGuise JA, Sati M, Brodeur P, Rivard CH (1995) Computer-assisted pedicle screw fixation: a feasibility study. Spine (Phila Pa 1976) 20:1208–1212CrossRef Amiot LP, Labelle H, DeGuise JA, Sati M, Brodeur P, Rivard CH (1995) Computer-assisted pedicle screw fixation: a feasibility study. Spine (Phila Pa 1976) 20:1208–1212CrossRef
17.
Zurück zum Zitat Rivkin MA, Yocom SS (2014) Thoracolumbar instrumentation with CT-guided navigation (O-arm) in 270 consecutive patients: accuracy rates and lessons learned. Neurosurg Focus 36(3):E7CrossRefPubMed Rivkin MA, Yocom SS (2014) Thoracolumbar instrumentation with CT-guided navigation (O-arm) in 270 consecutive patients: accuracy rates and lessons learned. Neurosurg Focus 36(3):E7CrossRefPubMed
18.
Zurück zum Zitat Klingler JH, Sircar R, Scheiwe C, Kogias E, Krüger MT, Scholz C, Hubbe U (2017) Comparative study of C-arms for intraoperative 3-dimensional imaging and navigation in minimally invasive spine surgery part II: radiation exposure. Clin Spine Surg 30:E669–669E676PubMed Klingler JH, Sircar R, Scheiwe C, Kogias E, Krüger MT, Scholz C, Hubbe U (2017) Comparative study of C-arms for intraoperative 3-dimensional imaging and navigation in minimally invasive spine surgery part II: radiation exposure. Clin Spine Surg 30:E669–669E676PubMed
19.
Zurück zum Zitat Wiesner L, Kothe R, Schulitz KP, Rüther W (2000) Clinical evaluation and computed tomography scan analysis of screw tracts after percutaneous insertion of pedicle screws in the lumbar spine. Spine (Phila Pa 1976) 25:615–621CrossRef Wiesner L, Kothe R, Schulitz KP, Rüther W (2000) Clinical evaluation and computed tomography scan analysis of screw tracts after percutaneous insertion of pedicle screws in the lumbar spine. Spine (Phila Pa 1976) 25:615–621CrossRef
20.
Zurück zum Zitat Perna F, Borghi R, Pilla F, Stefanini N, Mazzotti A, Chehrassan M (2016) Pedicle screw insertion techniques: an update and review of the literature. Musculoskelet Surg 100:165–169CrossRefPubMed Perna F, Borghi R, Pilla F, Stefanini N, Mazzotti A, Chehrassan M (2016) Pedicle screw insertion techniques: an update and review of the literature. Musculoskelet Surg 100:165–169CrossRefPubMed
Metadaten
Titel
Safe placement of pedicle screw in lumbar spine with minimum three year follow-up: a case series and technical note
verfasst von
Di Zhang
Xianda Gao
Jiang Jiang
Yong Shen
Wenyuan Ding
Huixian Cui
Publikationsdatum
02.02.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 3/2018
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-018-3806-1

Weitere Artikel der Ausgabe 3/2018

International Orthopaedics 3/2018 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.