Skip to main content
Erschienen in: Lung 3/2017

28.03.2017 | Pleural Disease

Safety and Feasibility of Pleural Cryobiopsy Compared to Forceps Biopsy During Semi-rigid Pleuroscopy

verfasst von: Vikas Pathak, Ray W. Shepherd, Ehab Hussein, Rajiv Malhotra

Erschienen in: Lung | Ausgabe 3/2017

Einloggen, um Zugang zu erhalten

Abstract

Background

Pleural biopsy is often obtained in patients with undiagnosed exudative pleural effusion during pleuroscopy. Standard forceps have been traditionally used for the biopsy. Cryoprobes are being increasingly used for transbronchial lung biopsy as they obtain larger specimens and have less crush artifact. However, the safety and feasibility of cryoprobe biopsy compared to standard forceps for pleural biopsy has not been fully assessed.

Objectives

The objective of this study was to demonstrate the safety and feasibility of cryoprobe biopsy in the pleural space using semi-rigid pleuroscopy.

Methods

Patients with idiopathic exudative pleural effusions underwent pleuroscopy. The procedure was done in the endoscopy suite with full barrier precautions and moderate sedation. Pleural biopsies were initially taken with a 2.0-mm saw-toothed forceps followed by a 2.4-mm cryoprobe (ERBECRYO, ERBE, US). The freeze time for each biopsy was 3 s.

Results

There were a total of ten patients, five males and five females. The mean age was 69 years (SD ± 11 years). The mean number of biopsies taken from the parietal pleura using forceps was 4.5 (SD ± 1.5) vs. 3.7 (SD ± 1.4) using cryoprobe. The mean cumulative tissue volume with forceps biopsy was 80 cu. mm; the mean cumulative tissue volume with cryobiopsy was 320 cu. mm, p = 0.007. The diagnostic yields were similar in both the groups. There was no increased incidence of bleeding, chest wall injury, or pain using cryoprobe in any of the patients.

Conclusion

The use of cryoprobe for parietal pleural biopsy via semi-rigid pleuroscopy was feasible and safe in this small pilot study.
Literatur
1.
Zurück zum Zitat Ernst A et al (2002) A novel instrument for the evaluation of the pleural space: an experience in 34 patients. Chest 122(5):1530–1534CrossRefPubMed Ernst A et al (2002) A novel instrument for the evaluation of the pleural space: an experience in 34 patients. Chest 122(5):1530–1534CrossRefPubMed
2.
Zurück zum Zitat Lee P, Colt HG (2005) Rigid and semirigid pleuroscopy: the future is bright. Respirology 10(4):418–425CrossRefPubMed Lee P, Colt HG (2005) Rigid and semirigid pleuroscopy: the future is bright. Respirology 10(4):418–425CrossRefPubMed
3.
Zurück zum Zitat Lee P et al (2007) Prospective evaluation of flex-rigid pleuroscopy for indeterminate pleural effusion: accuracy, safety and outcome. Respirology 12(6):881–886CrossRefPubMed Lee P et al (2007) Prospective evaluation of flex-rigid pleuroscopy for indeterminate pleural effusion: accuracy, safety and outcome. Respirology 12(6):881–886CrossRefPubMed
4.
Zurück zum Zitat McLean AN et al (1998) Investigation of pleural effusion: an evaluation of the new Olympus LTF semiflexible thoracofiberscope and comparison with Abram’s needle biopsy. Chest 114(1):150–153CrossRefPubMed McLean AN et al (1998) Investigation of pleural effusion: an evaluation of the new Olympus LTF semiflexible thoracofiberscope and comparison with Abram’s needle biopsy. Chest 114(1):150–153CrossRefPubMed
5.
Zurück zum Zitat Lentz RJ et al (2016) Transbronchial cryobiopsy can diagnose constrictive bronchiolitis in veterans of recent conflicts in the middle east. Am J Respir Crit Care Med 193(7):806–808CrossRefPubMedPubMedCentral Lentz RJ et al (2016) Transbronchial cryobiopsy can diagnose constrictive bronchiolitis in veterans of recent conflicts in the middle east. Am J Respir Crit Care Med 193(7):806–808CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Poletti V (2016) Increasing diagnostic value of transbronchial lung cryobiopsy. Respiration 91(4):350CrossRefPubMed Poletti V (2016) Increasing diagnostic value of transbronchial lung cryobiopsy. Respiration 91(4):350CrossRefPubMed
7.
Zurück zum Zitat Poletti V, Ravaglia C, Tomassetti S (2016) Transbronchial cryobiopsy in diffuse parenchymal lung diseases. Curr Opin Pulm Med 22(3):289–296CrossRefPubMed Poletti V, Ravaglia C, Tomassetti S (2016) Transbronchial cryobiopsy in diffuse parenchymal lung diseases. Curr Opin Pulm Med 22(3):289–296CrossRefPubMed
8.
Zurück zum Zitat Ramaswamy A et al (2016) Comparison of transbronchial and cryobiopsies in evaluation of diffuse parenchymal lung disease. J Bronchology Interv Pulmonol 23(1):14–21CrossRefPubMedPubMedCentral Ramaswamy A et al (2016) Comparison of transbronchial and cryobiopsies in evaluation of diffuse parenchymal lung disease. J Bronchology Interv Pulmonol 23(1):14–21CrossRefPubMedPubMedCentral
9.
Zurück zum Zitat Rozman A et al (2014) Feasibility and safety of parietal pleural cryobiopsy during semi-rigid thoracoscopy. Clin Respir J 10:574–578CrossRef Rozman A et al (2014) Feasibility and safety of parietal pleural cryobiopsy during semi-rigid thoracoscopy. Clin Respir J 10:574–578CrossRef
10.
Zurück zum Zitat Thomas R et al (2015) Pleuroscopic cryoprobe biopsies of the pleura: a feasibility and safety study. Respirology 20(2):327–332CrossRefPubMed Thomas R et al (2015) Pleuroscopic cryoprobe biopsies of the pleura: a feasibility and safety study. Respirology 20(2):327–332CrossRefPubMed
11.
Zurück zum Zitat Maturu VN et al (2015) Pleuroscopic cryobiopsy: case series and systematic review. J Bronchol Interv Pulmonol 22(3):e11–e13CrossRef Maturu VN et al (2015) Pleuroscopic cryobiopsy: case series and systematic review. J Bronchol Interv Pulmonol 22(3):e11–e13CrossRef
12.
Zurück zum Zitat Wurps H et al (2016) Intra-patient comparison of parietal pleural biopsies by rigid forceps, flexible forceps and cryoprobe obtained during medical thoracoscopy: a prospective series of 80 cases with pleural effusion. BMC Pulm Med 16(1):98CrossRefPubMedPubMedCentral Wurps H et al (2016) Intra-patient comparison of parietal pleural biopsies by rigid forceps, flexible forceps and cryoprobe obtained during medical thoracoscopy: a prospective series of 80 cases with pleural effusion. BMC Pulm Med 16(1):98CrossRefPubMedPubMedCentral
Metadaten
Titel
Safety and Feasibility of Pleural Cryobiopsy Compared to Forceps Biopsy During Semi-rigid Pleuroscopy
verfasst von
Vikas Pathak
Ray W. Shepherd
Ehab Hussein
Rajiv Malhotra
Publikationsdatum
28.03.2017
Verlag
Springer US
Erschienen in
Lung / Ausgabe 3/2017
Print ISSN: 0341-2040
Elektronische ISSN: 1432-1750
DOI
https://doi.org/10.1007/s00408-017-9998-0

Weitere Artikel der Ausgabe 3/2017

Lung 3/2017 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.