Background

We aimed to provide a systematic description of our 2-year experience using a standardized bedside, single burr hole approach to intracranial multimodality monitoring (MMM) in patients with severe traumatic brain injury (sTBI), focusing on safety and probe reliability.

Methods

We performed this observational cohort study at a university-affiliated, Level I trauma center with dedicated 20-bed neuroscience intensive care unit. We included 43 consecutive sTBI patients who required MMM to guide clinical care based on institutional protocol and had a four-lumen bolt placed to measure intracranial pressure, brain tissue oxygen, regional cerebral blood flow, brain temperature, and intracranial electroencephalography.

Results

sTBI patients were aged 41.6 ± 17.5 years (mean ± SD) and 84% were men. MMM devices were placed at a median of 12.5 h (interquartile range [IQR] 9.0–21.4 h) after injury and in non-dominant frontal lobe in 72.1% of cases. Monitoring was conducted for a median of 97.1 h (IQR 46.9–124.6 h) per patient. While minor hemorrhage, pneumocephalus, or small bone chips were common, only one (2.4%) patient experienced significant hemorrhage related to device placement. Radiographically, device malpositioning was noted in 13.9% of patients. Inadvertent device discontinuation occurred for at least one device in 58% of patients and was significantly associated with the frequency of travel for procedures or imaging. Devices remained in place for > 80% of the total monitoring period and generated usable data > 50% of that time.

Conclusions

A standardized, bedside single burr hole approach to MMM was safe. Despite some probe-specific recording limitations, MMM provided real-time measurements of intracranial pressure, oxygenation, regional cerebral blood flow, brain temperature, and function.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
2.
Zurück zum Zitat Carney N, Totten AM, O’Reilly C, et al. Guidelines for the management of severe traumatic brain injury, fourth edition. Neurosurgery. 2017;80:6–15.PubMed Carney N, Totten AM, O’Reilly C, et al. Guidelines for the management of severe traumatic brain injury, fourth edition. Neurosurgery. 2017;80:6–15.PubMed
3.
Zurück zum Zitat Okonkwo DO, Shutter LA, Moore C, et al. Brain oxygen optimization in severe traumatic brain injury phase-II: a phase II randomized trial. Crit Care Med. 2017;45:1907–14.CrossRefPubMedPubMedCentral Okonkwo DO, Shutter LA, Moore C, et al. Brain oxygen optimization in severe traumatic brain injury phase-II: a phase II randomized trial. Crit Care Med. 2017;45:1907–14.CrossRefPubMedPubMedCentral
4.
Zurück zum Zitat Le Roux P, Menon DK, Citerio G, et al. Consensus summary statement of the International Multidisciplinary Consensus Conference on Multimodality Monitoring in Neurocritical Care: a statement for healthcare professionals from the Neurocritical Care Society and the European Society of Intensive Care Medicine. Intensive Care Med. 2014;40:1189–209.CrossRefPubMed Le Roux P, Menon DK, Citerio G, et al. Consensus summary statement of the International Multidisciplinary Consensus Conference on Multimodality Monitoring in Neurocritical Care: a statement for healthcare professionals from the Neurocritical Care Society and the European Society of Intensive Care Medicine. Intensive Care Med. 2014;40:1189–209.CrossRefPubMed
5.
Zurück zum Zitat Dreier JP, Fabricius M, Ayata C, et al. Recording, analysis, and interpretation of spreading depolarizations in neurointensive care: review and recommendations of the COSBID research group. J Cereb Blood Flow Metab. 2017;37:1595–625.CrossRefPubMed Dreier JP, Fabricius M, Ayata C, et al. Recording, analysis, and interpretation of spreading depolarizations in neurointensive care: review and recommendations of the COSBID research group. J Cereb Blood Flow Metab. 2017;37:1595–625.CrossRefPubMed
6.
Zurück zum Zitat Hartings JA. Spreading depolarization monitoring in neurocritical care of acute brain injury. Curr Opin Crit Care. 2017;23:94–102.CrossRefPubMed Hartings JA. Spreading depolarization monitoring in neurocritical care of acute brain injury. Curr Opin Crit Care. 2017;23:94–102.CrossRefPubMed
7.
Zurück zum Zitat Vespa P, Tubi M, Claassen J, et al. Metabolic crisis occurs with seizures and periodic discharges after brain trauma. Ann Neurol. 2016;79:579–90.CrossRefPubMed Vespa P, Tubi M, Claassen J, et al. Metabolic crisis occurs with seizures and periodic discharges after brain trauma. Ann Neurol. 2016;79:579–90.CrossRefPubMed
8.
Zurück zum Zitat Hawryluk GWJ, Phan N, Ferguson AR, et al. Brain tissue oxygen tension and its response to physiological manipulations: influence of distance from injury site in a swine model of traumatic brain injury. J Neurosurg. 2016;125:1217–28.CrossRefPubMed Hawryluk GWJ, Phan N, Ferguson AR, et al. Brain tissue oxygen tension and its response to physiological manipulations: influence of distance from injury site in a swine model of traumatic brain injury. J Neurosurg. 2016;125:1217–28.CrossRefPubMed
9.
Zurück zum Zitat Cunningham AS, Salvador R, Coles JP, et al. Physiological thresholds for irreversible tissue damage in contusional regions following traumatic brain injury. Brain. 2005;128:1931–42.CrossRefPubMed Cunningham AS, Salvador R, Coles JP, et al. Physiological thresholds for irreversible tissue damage in contusional regions following traumatic brain injury. Brain. 2005;128:1931–42.CrossRefPubMed
10.
Zurück zum Zitat Jeffcote T, Hinzman JM, Jewell SL, et al. Detection of spreading depolarization with intraparenchymal electrodes in the injured human brain. Neurocrit Care. 2014;20:21–31.CrossRefPubMed Jeffcote T, Hinzman JM, Jewell SL, et al. Detection of spreading depolarization with intraparenchymal electrodes in the injured human brain. Neurocrit Care. 2014;20:21–31.CrossRefPubMed
11.
Zurück zum Zitat Steyerberg EW, Mushkudiani N, Perel P, et al. Predicting outcome after traumatic brain injury: development and international validation of prognostic scores based on admission characteristics. PLoS Med. 2008;5:e165.CrossRefPubMedPubMedCentral Steyerberg EW, Mushkudiani N, Perel P, et al. Predicting outcome after traumatic brain injury: development and international validation of prognostic scores based on admission characteristics. PLoS Med. 2008;5:e165.CrossRefPubMedPubMedCentral
12.
Zurück zum Zitat Cnossen MC, Huijben JA, van der Jagt M, et al. Variation in monitoring and treatment policies for intracranial hypertension in traumatic brain injury: a survey in 66 neurotrauma centers participating in the CENTER-TBI study. Crit Care Lond Engl. 2017;21:233.CrossRef Cnossen MC, Huijben JA, van der Jagt M, et al. Variation in monitoring and treatment policies for intracranial hypertension in traumatic brain injury: a survey in 66 neurotrauma centers participating in the CENTER-TBI study. Crit Care Lond Engl. 2017;21:233.CrossRef
13.
Zurück zum Zitat Jones PA, Andrews PJ, Midgley S, et al. Measuring the burden of secondary insults in head-injured patients during intensive care. J Neurosurg Anesthesiol. 1994;6:4–14.CrossRefPubMed Jones PA, Andrews PJ, Midgley S, et al. Measuring the burden of secondary insults in head-injured patients during intensive care. J Neurosurg Anesthesiol. 1994;6:4–14.CrossRefPubMed
14.
Zurück zum Zitat Badri S, Chen J, Barber J, et al. Mortality and long-term functional outcome associated with intracranial pressure after traumatic brain injury. Intensive Care Med. 2012;38:1800–9.CrossRefPubMed Badri S, Chen J, Barber J, et al. Mortality and long-term functional outcome associated with intracranial pressure after traumatic brain injury. Intensive Care Med. 2012;38:1800–9.CrossRefPubMed
15.
16.
Zurück zum Zitat Yuan Q, Wu X, Sun Y, et al. Impact of intracranial pressure monitoring on mortality in patients with traumatic brain injury: a systematic review and meta-analysis. J Neurosurg. 2015;122:574–87.CrossRefPubMed Yuan Q, Wu X, Sun Y, et al. Impact of intracranial pressure monitoring on mortality in patients with traumatic brain injury: a systematic review and meta-analysis. J Neurosurg. 2015;122:574–87.CrossRefPubMed
17.
Zurück zum Zitat Shen L, Wang Z, Su Z, et al. Effects of intracranial pressure monitoring on mortality in patients with severe traumatic brain injury: a meta-analysis. PLoS ONE. 2016;11:e0168901.CrossRefPubMedPubMedCentral Shen L, Wang Z, Su Z, et al. Effects of intracranial pressure monitoring on mortality in patients with severe traumatic brain injury: a meta-analysis. PLoS ONE. 2016;11:e0168901.CrossRefPubMedPubMedCentral
18.
Zurück zum Zitat Nangunoori R, Maloney-Wilensky E, Stiefel M, et al. Brain tissue oxygen-based therapy and outcome after severe traumatic brain injury: a systematic literature review. Neurocrit Care. 2012;17:131–8.CrossRefPubMed Nangunoori R, Maloney-Wilensky E, Stiefel M, et al. Brain tissue oxygen-based therapy and outcome after severe traumatic brain injury: a systematic literature review. Neurocrit Care. 2012;17:131–8.CrossRefPubMed
19.
Zurück zum Zitat Stuart RM, Schmidt M, Kurtz P, et al. Intracranial multimodal monitoring for acute brain injury: a single institution review of current practices. Neurocrit Care. 2010;12:188–98.CrossRefPubMed Stuart RM, Schmidt M, Kurtz P, et al. Intracranial multimodal monitoring for acute brain injury: a single institution review of current practices. Neurocrit Care. 2010;12:188–98.CrossRefPubMed
20.
Zurück zum Zitat Patil V, Lacson R, Vosburgh KG, et al. Factors associated with external ventricular drain placement accuracy: data from an electronic health record repository. Acta Neurochir (Wien). 2013;155:1773–9.CrossRef Patil V, Lacson R, Vosburgh KG, et al. Factors associated with external ventricular drain placement accuracy: data from an electronic health record repository. Acta Neurochir (Wien). 2013;155:1773–9.CrossRef
21.
Zurück zum Zitat Binz DD, Toussaint LG, Friedman JA. Hemorrhagic complications of ventriculostomy placement: a meta-analysis. Neurocrit Care. 2009;10:253–6.CrossRefPubMed Binz DD, Toussaint LG, Friedman JA. Hemorrhagic complications of ventriculostomy placement: a meta-analysis. Neurocrit Care. 2009;10:253–6.CrossRefPubMed
22.
Zurück zum Zitat Bauer DF, Razdan SN, Bartolucci AA, et al. Meta-analysis of hemorrhagic complications from ventriculostomy placement by neurosurgeons. Neurosurgery. 2011;69:255–60.CrossRefPubMed Bauer DF, Razdan SN, Bartolucci AA, et al. Meta-analysis of hemorrhagic complications from ventriculostomy placement by neurosurgeons. Neurosurgery. 2011;69:255–60.CrossRefPubMed
23.
Zurück zum Zitat Gardner PA, Engh J, Atteberry D, et al. Hemorrhage rates after external ventricular drain placement. J Neurosurg. 2009;110:1021–5.CrossRefPubMed Gardner PA, Engh J, Atteberry D, et al. Hemorrhage rates after external ventricular drain placement. J Neurosurg. 2009;110:1021–5.CrossRefPubMed
24.
Zurück zum Zitat Maniker AH, Vaynman AY, Karimi RJ, et al. Hemorrhagic complications of external ventricular drainage. Neurosurgery. 2006;59:ONS419–24.PubMed Maniker AH, Vaynman AY, Karimi RJ, et al. Hemorrhagic complications of external ventricular drainage. Neurosurgery. 2006;59:ONS419–24.PubMed
25.
Zurück zum Zitat Poca M-A, Sahuquillo J, Arribas M, et al. Fiberoptic intraparenchymal brain pressure monitoring with the Camino V420 monitor: reflections on our experience in 163 severely head-injured patients. J Neurotrauma. 2002;19:439–48.CrossRefPubMed Poca M-A, Sahuquillo J, Arribas M, et al. Fiberoptic intraparenchymal brain pressure monitoring with the Camino V420 monitor: reflections on our experience in 163 severely head-injured patients. J Neurotrauma. 2002;19:439–48.CrossRefPubMed
26.
Zurück zum Zitat Koskinen L-OD, Grayson D, Olivecrona M. The complications and the position of the Codman MicroSensor™ ICP device: an analysis of 549 patients and 650 Sensors. Acta Neurochir (Wien). 2013;155:2141–8.CrossRef Koskinen L-OD, Grayson D, Olivecrona M. The complications and the position of the Codman MicroSensor™ ICP device: an analysis of 549 patients and 650 Sensors. Acta Neurochir (Wien). 2013;155:2141–8.CrossRef
27.
Zurück zum Zitat Bekar A, Doğan S, Abaş F, et al. Risk factors and complications of intracranial pressure monitoring with a fiberoptic device. J Clin Neurosci. 2009;16:236–40.CrossRefPubMed Bekar A, Doğan S, Abaş F, et al. Risk factors and complications of intracranial pressure monitoring with a fiberoptic device. J Clin Neurosci. 2009;16:236–40.CrossRefPubMed
28.
Zurück zum Zitat Wolf S, Horn P, Frenzel C, et al. Comparison of a new brain tissue oxygenation probe with the established standard. Acta Neurochir Suppl. 2012;114:161–4.CrossRefPubMed Wolf S, Horn P, Frenzel C, et al. Comparison of a new brain tissue oxygenation probe with the established standard. Acta Neurochir Suppl. 2012;114:161–4.CrossRefPubMed
29.
Zurück zum Zitat Ngwenya LB, Burke JF, Manley GT. Brain tissue oxygen monitoring and the intersection of brain and lung: a comprehensive review. Respir Care. 2016;61:1232–44.CrossRefPubMed Ngwenya LB, Burke JF, Manley GT. Brain tissue oxygen monitoring and the intersection of brain and lung: a comprehensive review. Respir Care. 2016;61:1232–44.CrossRefPubMed
30.
Zurück zum Zitat Hinzman JM, Andaluz N, Shutter LA, et al. Inverse neurovascular coupling to cortical spreading depolarizations in severe brain trauma. Brain J Neurol. 2014;137:2960–72.CrossRef Hinzman JM, Andaluz N, Shutter LA, et al. Inverse neurovascular coupling to cortical spreading depolarizations in severe brain trauma. Brain J Neurol. 2014;137:2960–72.CrossRef
31.
Zurück zum Zitat Lozier AP, Sciacca RR, Romagnoli MF, et al. Ventriculostomy-related infections: a critical review of the literature. Neurosurgery. 2002;51:170–81.CrossRefPubMed Lozier AP, Sciacca RR, Romagnoli MF, et al. Ventriculostomy-related infections: a critical review of the literature. Neurosurgery. 2002;51:170–81.CrossRefPubMed
32.
Zurück zum Zitat Li C, Narayan RK, Wang P, et al. Regional temperature and quantitative cerebral blood flow responses to cortical spreading depolarization in the rat. J Cereb Blood Flow Metab. 2017;37:1634–40.CrossRefPubMed Li C, Narayan RK, Wang P, et al. Regional temperature and quantitative cerebral blood flow responses to cortical spreading depolarization in the rat. J Cereb Blood Flow Metab. 2017;37:1634–40.CrossRefPubMed
Metadaten
Titel
Safety and Reliability of Bedside, Single Burr Hole Technique for Intracranial Multimodality Monitoring in Severe Traumatic Brain Injury
verfasst von
Brandon Foreman
Laura B. Ngwenya
Erica Stoddard
Jason M. Hinzman
Norberto Andaluz
Jed A. Hartings
Publikationsdatum
08.06.2018
Verlag
Springer US
Erschienen in
Neurocritical Care / Ausgabe 3/2018
Print ISSN: 1541-6933
Elektronische ISSN: 1556-0961
DOI
https://doi.org/10.1007/s12028-018-0551-7

Kompaktes Leitlinien-Wissen Neurologie (Link öffnet in neuem Fenster)

Mit medbee Pocketcards schnell und sicher entscheiden.
Leitlinien-Wissen kostenlos und immer griffbereit auf ihrem Desktop, Handy oder Tablet.

Neu im Fachgebiet Neurologie

Schlaganfall oder Schlaganfall-Imitator?

Ein breites Spektrum von Erkrankungen kann einen Schlaganfall vortäuschen. Bei der notwendigen schnellen Unterscheidung zwischen solchen „stroke mimics“ und echten Schlaganfällen können einige klinische Faktoren und Symptome unterstützend herangezogen werden. 

Ein pulverisierter Plastiklöffel im Gehirn

Das menschliche Gehirn besteht zu etwa 0,5% aus Nanoplastik – Tendenz weiter steigend. Nach Resultaten eine Autopsiestudie reichert sich Plastik im Gehirn 10- bis 30-fach stärker an als in anderen Organen – mit bislang noch völlig unklaren Folgen.

Schlaganfall durch wandernde A. carotis interna

Die Thrombolyse nützte nichts, vielmehr war eine Teilresektion des Zungenbeins nötig: Es hatte eine verlagerte Carotis interna komprimiert und so bei einem älteren Mann einen Schlaganfall ausgelöst. Per Bildgebung lässt sich eine solche Ursache manchmal nur schwer nachweisen.

Epileptischer Anfall nach Darmreinigung

Die Darmreinigung vor einer Koloskopie führte einen älteren Mann auf die Intensivstation: Seine Natriumwerte waren durch die Prozedur so gesunken, dass er Bewusstseinstrübungen und Krampfanfälle entwickelte.

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.