Abstract

Interventional occluder implantation has become the preferred mode of treatment in children with clinically significant atrial septal defect (ASD). The continuous increase in the number of patients treated calls for long-term data on device integrity and biocompatibility. We report a child who underwent successful interventional ASD closure at age 5 years. Secondary residual shunt occurred after 3 years of follow-up, and surgical ASD closure became necessary at age 12 years. The Amplatzer occluder device, which was removed after 7 years in vivo, showed no signs of mechanical failure, corrosion, or clinically relevant immunological response at the device–tissue interface.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Ding ZR, Qin YW, Hu JQ et al (2009) A new pan-nitinol occluder for transcatheter closure of ventricular septal defects in a canine model. Interv Cardiol 22:191–198CrossRef Ding ZR, Qin YW, Hu JQ et al (2009) A new pan-nitinol occluder for transcatheter closure of ventricular septal defects in a canine model. Interv Cardiol 22:191–198CrossRef
2.
Zurück zum Zitat Du ZD, Hijazi ZM, Kleinman CS, Silverman NH, Larntz K, Amplatzer Investigators (2002) Comparison between transcatheter and surgical closure of secundum atrial septal defect in children and adults: Results of a multicenter nonrandomized trial. Am Coll Cardiol 39:1836–1844CrossRef Du ZD, Hijazi ZM, Kleinman CS, Silverman NH, Larntz K, Amplatzer Investigators (2002) Comparison between transcatheter and surgical closure of secundum atrial septal defect in children and adults: Results of a multicenter nonrandomized trial. Am Coll Cardiol 39:1836–1844CrossRef
3.
Zurück zum Zitat Kong H, Wilkinson JL, Coe JY et al (2002) Corrosive behaviour of Amplatzer devices in experimental and biological environments. Cardiol Young 12:260–265CrossRefPubMed Kong H, Wilkinson JL, Coe JY et al (2002) Corrosive behaviour of Amplatzer devices in experimental and biological environments. Cardiol Young 12:260–265CrossRefPubMed
4.
Zurück zum Zitat Masura J, Gavora P, Formanek A, Hijazi ZM (1997) Transcatheter closure of secundum atrial septal defects using the new self-centering Amplatzer septal occluder: Initial human experience. Cathet Cardiovasc Diagn 42:388–393CrossRefPubMed Masura J, Gavora P, Formanek A, Hijazi ZM (1997) Transcatheter closure of secundum atrial septal defects using the new self-centering Amplatzer septal occluder: Initial human experience. Cathet Cardiovasc Diagn 42:388–393CrossRefPubMed
5.
Zurück zum Zitat Masura J, Gavora P, Podnar T (2005) Long-term outcome of transcatheter secundum-type atrial septal defect closure using Amplatzer septal occluders. J Am Coll Cardiol 45:505–507CrossRefPubMed Masura J, Gavora P, Podnar T (2005) Long-term outcome of transcatheter secundum-type atrial septal defect closure using Amplatzer septal occluders. J Am Coll Cardiol 45:505–507CrossRefPubMed
6.
Zurück zum Zitat Omeish A, Hijazi ZM (2001) Transcatheter closure of atrial septal defects in children and adults using the Amplatzer septal occluder. Interv Cardiol 14:37–44CrossRef Omeish A, Hijazi ZM (2001) Transcatheter closure of atrial septal defects in children and adults using the Amplatzer septal occluder. Interv Cardiol 14:37–44CrossRef
7.
Zurück zum Zitat Sharafuddin MJ, Gu X, Titus JL et al (1997) Transvenous closure of secundum atrial septal defects: preliminary results with a new self-expanding nitinol prosthesis in a swine model. Circulation 95:2162–2168PubMed Sharafuddin MJ, Gu X, Titus JL et al (1997) Transvenous closure of secundum atrial septal defects: preliminary results with a new self-expanding nitinol prosthesis in a swine model. Circulation 95:2162–2168PubMed
8.
9.
Zurück zum Zitat Sigler M, Paul T, Grabitz RG (2005) Biocompatibility screening in cardiovascular implants. Z Kardiol 94:383–391CrossRefPubMed Sigler M, Paul T, Grabitz RG (2005) Biocompatibility screening in cardiovascular implants. Z Kardiol 94:383–391CrossRefPubMed
10.
Zurück zum Zitat Sigler M, Jux C, Ewert P (2006) Histopathological workup of an Amplatzer atrial septal defect occluder after surgical removal. Pediatr Cardiol 27:775–776CrossRefPubMed Sigler M, Jux C, Ewert P (2006) Histopathological workup of an Amplatzer atrial septal defect occluder after surgical removal. Pediatr Cardiol 27:775–776CrossRefPubMed
11.
Zurück zum Zitat Xiangqing K, Kejiang C, Rong Y et al (2002) Transcatheter closure of secundum atrial septal defects using Amplatzer septal occluder. Chin Med 115:126–128 Xiangqing K, Kejiang C, Rong Y et al (2002) Transcatheter closure of secundum atrial septal defects using Amplatzer septal occluder. Chin Med 115:126–128
Metadaten
Titel
Secondary Residual Shunt After Atrial Septal Defect Closure With an Amplatzer Occluder: Surgical Removal and Evaluation of Device Biocompatibility After 7 Years
verfasst von
Weihua Zhu
Henning Neubauer
Publikationsdatum
01.10.2010
Verlag
Springer-Verlag
Erschienen in
Pediatric Cardiology / Ausgabe 7/2010
Print ISSN: 0172-0643
Elektronische ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-010-9757-y

Weitere Artikel der Ausgabe 7/2010

Pediatric Cardiology 7/2010 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.