Skip to main content
Erschienen in:

01.06.2019 | ABDOMINAL RADIOLOGY

Selective occlusion of splenic artery aneurysms with the coil packing technique: the impact of packing density on aneurysm reperfusion correlated between contrast-enhanced MR angiography and digital subtraction angiography

verfasst von: Mikołaj Wojtaszek, Krzysztof Lamparski, Emilia Wnuk, Tomasz Ostrowski, Rafał Maciąg, Thomas Rix, Edyta Maj, Krzysztof Milczarek, Krzysztof Korzeniowski, Olgierd Rowiński

Erschienen in: La radiologia medica | Ausgabe 6/2019

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The aim was to evaluate the relationship between coil packing densities after splenic artery aneurysm (SAA) treatment using detachable microcoils and rates of SAA reperfusion and to suggest a post-treatment surveillance protocol using contrast-enhanced MRA.

Materials and methods

Evaluated were 16 patients (4 men; mean age 46.7), who underwent true SAA embolization using detachable microcoils (Concerto, Medtronic). SAAs were treated by selective coil packing (CP) or stent-assisted coil exclusion (SAC). Contrast-enhanced magnetic resonance angiography (CE-MRA) and digital subtraction angiography (DSA) were performed at 3 months post-procedure and correlated.

Results

Primary CP was used in 13 patients, while SAC was used in three patients. On follow-up, complete aneurysm occlusion was seen in seven patients (43.8%). Sac reperfusion occurred in nine patients (56.2%) and was demonstrated in all CE-MRA and six DSA studies. Mean aneurysm packing density was 20.10 ± 8.05% for the CP group and 32.90 ± 11.95% for the SAC group (p = 0.038). There was a significant difference in the incidence of aneurysm sac reperfusion on CE-MRA study between CP and SAC (9 vs. 0). No sac reperfusion was seen in aneurysms with packing densities ≥ 29%, irrespective of either embolization method.

Conclusion

Favorable midterm results for coil packing of SAAs seem to depend on the coil packing density with a coil volume approximately a quarter of the aneurysm volume being most effective. Follow-up should involve the use of CE-MRA as this modality has been shown to be superior over DSA in detecting aneurysm reperfusion and coil compaction.

Level of evidence

Level IV, therapeutic study.
Literatur
1.
Zurück zum Zitat Hirsch AT, Haskal ZJ, Hertzer NR, Bakal CW, Creager MA, Halperin JL et al., American Association for Vascular Surgery/Society for Vascular Surgery, Society for Cardiovascular Angiography and Interventions, Society for Vascular Medicine and Biology, Society of Interventional Radiology, ACC/AHA Task Force on Practice Guidelines (2006) ACC/AHA Guidelines for the Management of Patients with Peripheral Arterial Disease (lower extremity, renal, mesenteric, and abdominal aortic): a collaborative report from the American Associations for Vascular Surgery/Society for Vascular Surgery, Society for Cardiovascular Angiography and Interventions, Society for Vascular Medicine and Biology, Society of Interventional Radiology, and the ACC/AHA Task Force on Practice Guidelines. J Vasc Interv Radiol 17(9):1383–1397. (PMID: 16990459) Hirsch AT, Haskal ZJ, Hertzer NR, Bakal CW, Creager MA, Halperin JL et al., American Association for Vascular Surgery/Society for Vascular Surgery, Society for Cardiovascular Angiography and Interventions, Society for Vascular Medicine and Biology, Society of Interventional Radiology, ACC/AHA Task Force on Practice Guidelines (2006) ACC/AHA Guidelines for the Management of Patients with Peripheral Arterial Disease (lower extremity, renal, mesenteric, and abdominal aortic): a collaborative report from the American Associations for Vascular Surgery/Society for Vascular Surgery, Society for Cardiovascular Angiography and Interventions, Society for Vascular Medicine and Biology, Society of Interventional Radiology, and the ACC/AHA Task Force on Practice Guidelines. J Vasc Interv Radiol 17(9):1383–1397. (PMID: 16990459)
3.
Zurück zum Zitat Pasha SF, Gloviczki P, Stanson AW, Kamath PS (2007) Splanchnic artery aneurysms. Mayo Clin Proc 82(4):472–479 (PMID: 17418076) CrossRefPubMed Pasha SF, Gloviczki P, Stanson AW, Kamath PS (2007) Splanchnic artery aneurysms. Mayo Clin Proc 82(4):472–479 (PMID: 17418076) CrossRefPubMed
4.
Zurück zum Zitat Ha JF, Phillips M, Faulkner K (2009) Splenic artery aneurysm rupture in pregnancy. Eur J Obstet Gynecol Reprod Biol 146(2):133–137 (PMID: 19596508) CrossRefPubMed Ha JF, Phillips M, Faulkner K (2009) Splenic artery aneurysm rupture in pregnancy. Eur J Obstet Gynecol Reprod Biol 146(2):133–137 (PMID: 19596508) CrossRefPubMed
5.
Zurück zum Zitat Iryo Y, Ikushima I, Hirai T, Yonenaga K, Yamashita Y (2013) Evaluation of contrast-enhanced MR angiography in the follow-up of visceral arterial aneurysms after coil embolization. Acta Radiol 54(5):493–497 (PMID: 23436827) CrossRefPubMed Iryo Y, Ikushima I, Hirai T, Yonenaga K, Yamashita Y (2013) Evaluation of contrast-enhanced MR angiography in the follow-up of visceral arterial aneurysms after coil embolization. Acta Radiol 54(5):493–497 (PMID: 23436827) CrossRefPubMed
6.
Zurück zum Zitat Koganemaru M, Abe T, Uchiyama D, Iwamoto R, Yoshida S, Hayabuchi N et al (2010) Detection of neck recanalization with follow-up contrast-enhanced MR angiography after renal artery aneurysm coil embolization. J Vasc Interv Radiol 21(2):298–300 (PMID: 20045655) CrossRefPubMed Koganemaru M, Abe T, Uchiyama D, Iwamoto R, Yoshida S, Hayabuchi N et al (2010) Detection of neck recanalization with follow-up contrast-enhanced MR angiography after renal artery aneurysm coil embolization. J Vasc Interv Radiol 21(2):298–300 (PMID: 20045655) CrossRefPubMed
7.
Zurück zum Zitat Roy D, Milot G, Raymond J (2001) Endovascular treatment of unruptured aneurysms. Stroke 32(9):1998–2004 (PMID: 11546888) CrossRefPubMed Roy D, Milot G, Raymond J (2001) Endovascular treatment of unruptured aneurysms. Stroke 32(9):1998–2004 (PMID: 11546888) CrossRefPubMed
8.
Zurück zum Zitat Xin J, Xiao-Ping L, Wei G, Jiang X, Hong-Peng Z, Xiao-Hui M et al (2011) The endovascular management of splenic artery aneurysms and pseudoaneurysms. Vascular 19(5):257–261 (PMID:21903857) CrossRefPubMed Xin J, Xiao-Ping L, Wei G, Jiang X, Hong-Peng Z, Xiao-Hui M et al (2011) The endovascular management of splenic artery aneurysms and pseudoaneurysms. Vascular 19(5):257–261 (PMID:21903857) CrossRefPubMed
9.
Zurück zum Zitat Yasumoto T, Osuga K, Yamamoto H, Ono Y, Masada M, Mikami K et al (2013) Long-term outcomes of coil packing for visceral aneurysms: correlation between packing density and incidence of coil compaction or recanalization. J Vasc Interv Radiol 24(12):1798–1807 (PMID: 23810652) CrossRefPubMed Yasumoto T, Osuga K, Yamamoto H, Ono Y, Masada M, Mikami K et al (2013) Long-term outcomes of coil packing for visceral aneurysms: correlation between packing density and incidence of coil compaction or recanalization. J Vasc Interv Radiol 24(12):1798–1807 (PMID: 23810652) CrossRefPubMed
10.
Zurück zum Zitat Guillon R, Garcier JM, Abergel A, Mofid R, Garcia V, Chahid T et al (2003) Management of splenic artery aneurysms and false aneurysms with endovascular treatment in 12 patients. Cardiovasc Intervent Radiol 26(3):256–260 (PMID: 14562974) CrossRefPubMed Guillon R, Garcier JM, Abergel A, Mofid R, Garcia V, Chahid T et al (2003) Management of splenic artery aneurysms and false aneurysms with endovascular treatment in 12 patients. Cardiovasc Intervent Radiol 26(3):256–260 (PMID: 14562974) CrossRefPubMed
11.
Zurück zum Zitat Seo JM, Park KB, Kim KH, Jeon P, Shin SW, Park HS et al (2011) Clinical and multidetector CT follow-up results of renal artery aneurysms treated by detachable coil embolization using 3D rotational angiography. Acta Radiol 52(8):854–859 (PMID: 21840966) CrossRefPubMed Seo JM, Park KB, Kim KH, Jeon P, Shin SW, Park HS et al (2011) Clinical and multidetector CT follow-up results of renal artery aneurysms treated by detachable coil embolization using 3D rotational angiography. Acta Radiol 52(8):854–859 (PMID: 21840966) CrossRefPubMed
12.
Zurück zum Zitat Koganemaru M, Abe T, Nonoshita M, Iwamoto R, Kusumoto M, Kuhara A, Kugiyama T (2014) Follow-up of true visceral artery aneurysm after coil embolization by three-dimensional contrast-enhanced MR angiography. Diagn Interv Radiol 20(2):129–135 (PMID: 24356294) PubMed Koganemaru M, Abe T, Nonoshita M, Iwamoto R, Kusumoto M, Kuhara A, Kugiyama T (2014) Follow-up of true visceral artery aneurysm after coil embolization by three-dimensional contrast-enhanced MR angiography. Diagn Interv Radiol 20(2):129–135 (PMID: 24356294) PubMed
Metadaten
Titel
Selective occlusion of splenic artery aneurysms with the coil packing technique: the impact of packing density on aneurysm reperfusion correlated between contrast-enhanced MR angiography and digital subtraction angiography
verfasst von
Mikołaj Wojtaszek
Krzysztof Lamparski
Emilia Wnuk
Tomasz Ostrowski
Rafał Maciąg
Thomas Rix
Edyta Maj
Krzysztof Milczarek
Krzysztof Korzeniowski
Olgierd Rowiński
Publikationsdatum
01.06.2019
Verlag
Springer Milan
Erschienen in
La radiologia medica / Ausgabe 6/2019
Print ISSN: 0033-8362
Elektronische ISSN: 1826-6983
DOI
https://doi.org/10.1007/s11547-019-00993-2

Neu im Fachgebiet Radiologie

KI-gestütztes Mammografiescreening überzeugt im Praxistest

Mit dem Einsatz künstlicher Intelligenz lässt sich die Detektionsrate im Mammografiescreening offenbar deutlich steigern. Mehr unnötige Zusatzuntersuchungen sind laut der Studie aus Deutschland nicht zu befürchten.

Stumme Schlaganfälle − ein häufiger Nebenbefund im Kopf-CT?

In 4% der in der Notfallambulanz initiierten zerebralen Bildgebung sind „alte“ Schlaganfälle zu erkennen. Gar nicht so selten handelt es sich laut einer aktuellen Studie dabei um unbemerkte Insulte. Bietet sich hier womöglich die Chance auf ein effektives opportunistisches Screening?

Die elektronische Patientenakte kommt: Das sollten Sie jetzt wissen

Am 15. Januar geht die „ePA für alle“ zunächst in den Modellregionen an den Start. Doch schon bald soll sie in allen Praxen zum Einsatz kommen. Was ist jetzt zu tun? Was müssen Sie wissen? Wir geben in einem FAQ Antworten auf 21 Fragen.

Stören weiße Wände und viel Licht die Bildqualitätskontrolle?

Wenn es darum geht, die technische Qualität eines Mammogramms zu beurteilen, könnten graue Wandfarbe und reduzierte Beleuchtung im Bildgebungsraum von Vorteil sein. Darauf deuten zumindest Ergebnisse einer kleinen Studie hin. 

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.