Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 12/2010

01.12.2010 | Orthopaedic Surgery

Serum metal ion levels after second-generation metal-on-metal total hip arthroplasty

verfasst von: Takao Imanishi, Masahiro Hasegawa, Akihiro Sudo

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 12/2010

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Metal-on-metal bearings for total hip arthroplasty are increasing in popularity. However, metal ion toxicity, metal hypersensitivity, and metal carcinogenicity are the causes concern for patients with metal-on-metal hip replacement. We investigated serum levels of cobalt and chromium ions in patients with successfully implanted second-generation metal-on-metal total hip arthroplasty (THA) using PINNACLE-A (DePuy, Warsaw, IN, USA).

Materials and methods

Thirty-three patients underwent primary cementless THA with the use of a 36-mm femoral head PINNACLE-A with a metal-on-metal articulation. Blood samples were taken preoperatively, at 3 months, and at 1 year, and levels of cobalt and chromium were determined.

Results

At 3 months, levels of both cobalt and chromium had increased significantly compared with preoperative levels. There were no significant differences between levels of either metal at 3 months and 1 year.

Conclusion

Patients with metal-on-metal THA had higher circulating levels of metal ions than before arthroplasty at 3 months, with no additional significant increases at 1 year in this study.
Literatur
1.
Zurück zum Zitat Cobb AG, Schmalzreid TP (2006) The clinical significance of metal ion release from cobalt–chromium metal-on-metal hip joint arthroplasty. Proc Inst Mech Eng 220:385–398 Cobb AG, Schmalzreid TP (2006) The clinical significance of metal ion release from cobalt–chromium metal-on-metal hip joint arthroplasty. Proc Inst Mech Eng 220:385–398
2.
Zurück zum Zitat Visuri TI, Pukkala E, Pulkkinen P, Paavolainen P (2006) Cancer incidence and causes of death among total hip replacement patients: a review based on Nordic cohorts with a special emphasis on metal-on-metal bearings. Proc Inst Mech Eng 220:399–407 Visuri TI, Pukkala E, Pulkkinen P, Paavolainen P (2006) Cancer incidence and causes of death among total hip replacement patients: a review based on Nordic cohorts with a special emphasis on metal-on-metal bearings. Proc Inst Mech Eng 220:399–407
3.
Zurück zum Zitat Engh CA, Hopper RH Jr, Engh CA Jr (2004) Long-term porous-coated cup survivorship using spikes, screws, and press-fitting for initial fixation. J Arthroplasty 19(7 Suppl 2):54–60CrossRefPubMed Engh CA, Hopper RH Jr, Engh CA Jr (2004) Long-term porous-coated cup survivorship using spikes, screws, and press-fitting for initial fixation. J Arthroplasty 19(7 Suppl 2):54–60CrossRefPubMed
4.
Zurück zum Zitat Powers CC, Ho H, Beykirch SE, Huynh C, Hopper RH Jr, Engh CA Jr, Engh CA (2009) A comparison of a second- and a third-generation modular cup design is new improved? J Arthroplasty. April 8. [Epub ahead of print] Powers CC, Ho H, Beykirch SE, Huynh C, Hopper RH Jr, Engh CA Jr, Engh CA (2009) A comparison of a second- and a third-generation modular cup design is new improved? J Arthroplasty. April 8. [Epub ahead of print]
5.
Zurück zum Zitat Ohashi H, Hirohashi K, Yamano Y (2000) Factors influencing the outcome of Chiari pelvic osteotomy: a long-term follow-up. J Bone Joint Surg Br B 82-B:517–525CrossRef Ohashi H, Hirohashi K, Yamano Y (2000) Factors influencing the outcome of Chiari pelvic osteotomy: a long-term follow-up. J Bone Joint Surg Br B 82-B:517–525CrossRef
6.
Zurück zum Zitat Antoniou J, Zukor DJ, Mwale F, Minarik W, Petit A, Huk OL (2008) Metal ion levels in the blood of patients after hip resurfacing: A comparison between twenty-eight and thirty-six-millimeter-head metal-on-metal prostheses. J Bone Joint Surg Am A 90(Suppl 3):142–148CrossRef Antoniou J, Zukor DJ, Mwale F, Minarik W, Petit A, Huk OL (2008) Metal ion levels in the blood of patients after hip resurfacing: A comparison between twenty-eight and thirty-six-millimeter-head metal-on-metal prostheses. J Bone Joint Surg Am A 90(Suppl 3):142–148CrossRef
7.
Zurück zum Zitat Williams S, Schepers A, Isaac G, Hardaker C, Ingham E, van der Jagt D, Breckon A, Fisher J (2007) Ceramic-on-metal hip arthroplasties: a comparative in vitro and in vivo study. Clin Orthop Relat Res 465:23–32PubMed Williams S, Schepers A, Isaac G, Hardaker C, Ingham E, van der Jagt D, Breckon A, Fisher J (2007) Ceramic-on-metal hip arthroplasties: a comparative in vitro and in vivo study. Clin Orthop Relat Res 465:23–32PubMed
8.
Zurück zum Zitat Isaac GH, Brockett C, Breckon A, van der Jagt D, Williams S, Hardaker C, Fisher J, Schepers A (2009) Ceramic-on-metal bearings in total hip replacement: whole blood metal ion levels and analysis of retrieved components. J Bone Joint Surg Br 91(9):1134–1141CrossRefPubMed Isaac GH, Brockett C, Breckon A, van der Jagt D, Williams S, Hardaker C, Fisher J, Schepers A (2009) Ceramic-on-metal bearings in total hip replacement: whole blood metal ion levels and analysis of retrieved components. J Bone Joint Surg Br 91(9):1134–1141CrossRefPubMed
9.
Zurück zum Zitat Savarino L, Granchi D, Ciapetti G, Cenni E, Nardi Pantoli A, Rotini R, Veronesi CA, Baldini N, Giunti A (2002) Ion release in patients with metal-on-metal hip bearings in total joint replacement:a comparison with metal-on-polyethylene bearings. J Biomed Mater Res 63:467–474CrossRefPubMed Savarino L, Granchi D, Ciapetti G, Cenni E, Nardi Pantoli A, Rotini R, Veronesi CA, Baldini N, Giunti A (2002) Ion release in patients with metal-on-metal hip bearings in total joint replacement:a comparison with metal-on-polyethylene bearings. J Biomed Mater Res 63:467–474CrossRefPubMed
10.
Zurück zum Zitat Clarke MT, Lee PTH, Arora A, Villar RN (2003) Levels of metal ions after small- and large-diameter metal-on-metal hip arthroplasty. J Bone Joint Surg Br B 85:913–917 Clarke MT, Lee PTH, Arora A, Villar RN (2003) Levels of metal ions after small- and large-diameter metal-on-metal hip arthroplasty. J Bone Joint Surg Br B 85:913–917
11.
Zurück zum Zitat Witzleb W, Ziegler J, Krummenauer F, Neumeister V, Guenther K (2006) Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty. Acta Orthop 77:697–705CrossRefPubMed Witzleb W, Ziegler J, Krummenauer F, Neumeister V, Guenther K (2006) Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty. Acta Orthop 77:697–705CrossRefPubMed
12.
Zurück zum Zitat Moroni A, Savarino L, Cadossi M, Baldini N, Giannini S (2008) Does ion release differ between hip resurfacing and metal-on-metal THA? Clin Orthop Relat Res 466:700–707CrossRefPubMed Moroni A, Savarino L, Cadossi M, Baldini N, Giannini S (2008) Does ion release differ between hip resurfacing and metal-on-metal THA? Clin Orthop Relat Res 466:700–707CrossRefPubMed
13.
Zurück zum Zitat Brodner W, Bitzan P, Meisinger V, Kaider A, Gottsauner-Wolf F, Kotz R (2003) Serum cobalt levels after metal-on-metal total hip arthroplasty. J Bone Joint Surg Am A 85:2168–2173 Brodner W, Bitzan P, Meisinger V, Kaider A, Gottsauner-Wolf F, Kotz R (2003) Serum cobalt levels after metal-on-metal total hip arthroplasty. J Bone Joint Surg Am A 85:2168–2173
14.
Zurück zum Zitat Hur CI, Yoon TR, Cho SG, Song EK, Seon JK (2008) Serum ion level after metal-on-metal THA in patients with renal failure. Clin Orthop Relat Res 466:696–699CrossRefPubMed Hur CI, Yoon TR, Cho SG, Song EK, Seon JK (2008) Serum ion level after metal-on-metal THA in patients with renal failure. Clin Orthop Relat Res 466:696–699CrossRefPubMed
15.
Zurück zum Zitat Zeh A, Becker C, Planert M, Lattke P, Wohlrab D (2009) Time-dependent release of cobalt and chromium ions into the serum following implantation of the metal-on-metal Maverick type artificial lumbar disc (Medtronic Sofamor Danek). Arch Orthop Trauma Surg 129(6):741–746CrossRefPubMed Zeh A, Becker C, Planert M, Lattke P, Wohlrab D (2009) Time-dependent release of cobalt and chromium ions into the serum following implantation of the metal-on-metal Maverick type artificial lumbar disc (Medtronic Sofamor Danek). Arch Orthop Trauma Surg 129(6):741–746CrossRefPubMed
16.
Zurück zum Zitat Vendittoli PA, Mottard S, Roy AG, Dupont C, Lavigne M (2007) Chromium and cobalt ion release following the Durom high carbon content, forged metal-on-metal surface replacement of the hip. J Bone Joint Surg Br B 89:441–448CrossRef Vendittoli PA, Mottard S, Roy AG, Dupont C, Lavigne M (2007) Chromium and cobalt ion release following the Durom high carbon content, forged metal-on-metal surface replacement of the hip. J Bone Joint Surg Br B 89:441–448CrossRef
17.
Zurück zum Zitat Haan RD, Pattyn C, Gill HS, Murray DW, Campbell PA, Smet KD (2008) Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. J Bone Joint Surg Br B 90:1291–1297CrossRef Haan RD, Pattyn C, Gill HS, Murray DW, Campbell PA, Smet KD (2008) Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. J Bone Joint Surg Br B 90:1291–1297CrossRef
18.
Zurück zum Zitat Langton DJ, Jameson SS, Joyce TJ, Webb J, Nargol AV (2008) The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip. J Bone Joint Surg Br B 90:1143–1151CrossRef Langton DJ, Jameson SS, Joyce TJ, Webb J, Nargol AV (2008) The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip. J Bone Joint Surg Br B 90:1143–1151CrossRef
19.
Zurück zum Zitat Heisel C, Silva M, Skipor AK, Jacobs JJ, Schmalzried TP (2005) The relationship between activity and ions in patients with metal-on-metal bearing hip prostheses. J Bone Joint Surg Am A 87:781–787CrossRef Heisel C, Silva M, Skipor AK, Jacobs JJ, Schmalzried TP (2005) The relationship between activity and ions in patients with metal-on-metal bearing hip prostheses. J Bone Joint Surg Am A 87:781–787CrossRef
20.
Zurück zum Zitat Kahn M, Kuiper JH, Richardson JB (2008) The exercise-related rise in plasma cobalt levels after metal-on-metal hip resurfacing arthroplasty. J Bone Joint Surg Br B 90:1152–1157CrossRef Kahn M, Kuiper JH, Richardson JB (2008) The exercise-related rise in plasma cobalt levels after metal-on-metal hip resurfacing arthroplasty. J Bone Joint Surg Br B 90:1152–1157CrossRef
21.
Zurück zum Zitat Ladon D, Doherty A, Newson R, Turner J, Bhamra M, Case CP (2004) Changes in metal levels and chromosome aberrations in the peripheral blood of patients after metal-on-metal hip arthroplasty. J Arthroplasty 19(8 Suppl 3):78–83CrossRefPubMed Ladon D, Doherty A, Newson R, Turner J, Bhamra M, Case CP (2004) Changes in metal levels and chromosome aberrations in the peripheral blood of patients after metal-on-metal hip arthroplasty. J Arthroplasty 19(8 Suppl 3):78–83CrossRefPubMed
22.
Zurück zum Zitat Dunstan E, Ladon D, Whittingham-Jones P, Carrington R, Briggs TW (2008) Chromosomal aberrations in the peripheral blood of patients with metal-on-metal hip bearings. J Bone Joint Surg Am A 90:517–522CrossRef Dunstan E, Ladon D, Whittingham-Jones P, Carrington R, Briggs TW (2008) Chromosomal aberrations in the peripheral blood of patients with metal-on-metal hip bearings. J Bone Joint Surg Am A 90:517–522CrossRef
Metadaten
Titel
Serum metal ion levels after second-generation metal-on-metal total hip arthroplasty
verfasst von
Takao Imanishi
Masahiro Hasegawa
Akihiro Sudo
Publikationsdatum
01.12.2010
Verlag
Springer-Verlag
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 12/2010
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-010-1056-9

Weitere Artikel der Ausgabe 12/2010

Archives of Orthopaedic and Trauma Surgery 12/2010 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.