ShearWave elastography: repeatability for measurement of tendon stiffness

verfasst von: C. D. Peltz, J. A. Haladik, G. Divine, D. Siegal, M. van Holsbeeck, M. J. Bey

Erschienen in: Skeletal Radiology | Ausgabe 8/2013

Einloggen, um Zugang zu erhalten

Excerpt

Tendon injuries are common and a significant source of pain and disability. Tendon injuries are often treated with a variety of non-surgical (e.g., physical therapy) and surgical interventions, along with a reduction of normal physical activities as the tendon heals [13]. However, it is difficult to objectively determine when the tendon has healed sufficiently and has the functional capacity to return to normal activities. Previous research has documented the functional capacity of tendons by measuring their stiffness under in vitro [4, 5] and in vivo [6, 7] conditions, but the technologies used for measuring tendon stiffness are applicable only to in vitro conditions (e.g., mechanical testing systems) or require the highly invasive implantation of sensors (e.g., strain gauges) under in vivo conditions. Conventional imaging modalities (e.g., ultrasound, MRI) can monitor changes in the appearance of tendons over time, but these imaging modalities do not provide an objective, quantitative assessment of tendon healing. A technique that could reliably provide a non-invasive quantitative assessment of tendon mechanical properties in vivo would have significant clinical application as a tool for monitoring tendon changes as a result of injury, pathology, and/or treatment. …
Literatur
5.
Zurück zum Zitat Soslowsky LJ, Thomopoulos S, Tun S, Flanagan CL, Keefer CC, Mastaw J et al (2000) Neer Award 1999. Overuse activity injures the supraspinatus tendon in an animal model: a histologic and biomechanical study. J Shoulder Elbow Surg 9(2):79–84PubMedCrossRef Soslowsky LJ, Thomopoulos S, Tun S, Flanagan CL, Keefer CC, Mastaw J et al (2000) Neer Award 1999. Overuse activity injures the supraspinatus tendon in an animal model: a histologic and biomechanical study. J Shoulder Elbow Surg 9(2):79–84PubMedCrossRef
6.
Zurück zum Zitat Ravary B, Pourcelot P, Bortolussi C, Konieczka S, Crevier-Denoix N (2004) Strain and force transducers used in human and veterinary tendon and ligament biomechanical studies. Clin Biomech (Bristol, Avon) 19(5):433–47CrossRef Ravary B, Pourcelot P, Bortolussi C, Konieczka S, Crevier-Denoix N (2004) Strain and force transducers used in human and veterinary tendon and ligament biomechanical studies. Clin Biomech (Bristol, Avon) 19(5):433–47CrossRef
7.
Zurück zum Zitat Rupert M, Grood E, Byczkowski T, Levy M (1998) Influence of sensor size on the accuracy of in-vivo ligament and tendon force measurements. J Biomech Eng 120(6):764–9PubMedCrossRef Rupert M, Grood E, Byczkowski T, Levy M (1998) Influence of sensor size on the accuracy of in-vivo ligament and tendon force measurements. J Biomech Eng 120(6):764–9PubMedCrossRef
8.
Zurück zum Zitat Evans A, Whelehan P, Thomson K, McLean D, Brauer K, Purdie C et al (2010) Quantitative shear wave ultrasound elastography: initial experience in solid breast masses. Breast Cancer Res 12(6):R104. doi:10.1186/bcr2787 PubMedCrossRef Evans A, Whelehan P, Thomson K, McLean D, Brauer K, Purdie C et al (2010) Quantitative shear wave ultrasound elastography: initial experience in solid breast masses. Breast Cancer Res 12(6):R104. doi:10.​1186/​bcr2787 PubMedCrossRef
10.
Zurück zum Zitat Ferraioli G, Tinelli C, Dal Bello B, Zicchetti M, Filice G, Filice C (2012) Accuracy of real-time shear wave elastography for assessing liver fibrosis in chronic hepatitis C: a pilot study. Hepatology 56(6):2125–33. doi:10.1002/hep.25936 PubMedCrossRef Ferraioli G, Tinelli C, Dal Bello B, Zicchetti M, Filice G, Filice C (2012) Accuracy of real-time shear wave elastography for assessing liver fibrosis in chronic hepatitis C: a pilot study. Hepatology 56(6):2125–33. doi:10.​1002/​hep.​25936 PubMedCrossRef
13.
Zurück zum Zitat Altman DG (1991) Practical statistics for medical research. Chapman and Hall, London Altman DG (1991) Practical statistics for medical research. Chapman and Hall, London
14.
Zurück zum Zitat Arda K, Ciledag N, Aktas E, Aribas BK, Kose K (2011) Quantitative assessment of normal soft-tissue elasticity using shear-wave ultrasound elastography. AJR Am J Roentgenol 197(3):532–6. doi:10.2214/AJR.10.5449 PubMedCrossRef Arda K, Ciledag N, Aktas E, Aribas BK, Kose K (2011) Quantitative assessment of normal soft-tissue elasticity using shear-wave ultrasound elastography. AJR Am J Roentgenol 197(3):532–6. doi:10.​2214/​AJR.​10.​5449 PubMedCrossRef
Metadaten
Titel
ShearWave elastography: repeatability for measurement of tendon stiffness
verfasst von
C. D. Peltz
J. A. Haladik
G. Divine
D. Siegal
M. van Holsbeeck
M. J. Bey
Publikationsdatum
01.08.2013
Verlag
Springer-Verlag
Erschienen in
Skeletal Radiology / Ausgabe 8/2013
Print ISSN: 0364-2348
Elektronische ISSN: 1432-2161
DOI
https://doi.org/10.1007/s00256-013-1629-0

Weitere Artikel der Ausgabe 8/2013

Skeletal Radiology 8/2013 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.