Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 7/2011

01.07.2011 | Knee

Simultaneous bilateral total knee arthroplasty with robotic and conventional techniques: a prospective, randomized study

verfasst von: Eun-Kyoo Song, Jong-Keun Seon, Sang-Jin Park, Woo Bin Jung, Hyeong-Won Park, Geon Woo Lee

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 7/2011

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The authors performed this study to compare the outcomes of robotic-assisted and conventional TKA in same patient simultaneously. It was hypothesized that the robotic-assisted procedure would produce better leg alignment and component orientation, and thus, improve patient satisfaction and clinical and radiological outcomes.

Methods

Thirty patients underwent bilateral sequential total knee replacement. One knee was replaced by robotic-assisted implantation and the other by conventional implantation.

Results

Radiographic results showed significantly more postoperative leg alignment outliers of conventional sides than robotic-assisted sides (mechanical axis, coronal inclination of the femoral prosthesis, and sagittal inclination of the tibial prosthesis). Robotic-assisted sides had non-significantly better postoperative knee scores and ROMs. Robotic-assisted sides needed longer operation times (25 min, SD ± 18) and longer skin incisions. Nevertheless, postoperative bleeding was significantly less for robotic-assisted sides.

Conclusion

The better alignment accuracy of robotic TKA and the good clinical results achieved may favorably influence clinical and radiological outcomes.

Level of evidence

I.
Literatur
1.
Zurück zum Zitat Bathis H, Perlick L, Tingart M, Perlick C, Luring C, Grifka J (2005) Intraoperative cutting errors in total knee arthroplasty. Arch Orthop Trauma Surg 125:16–20PubMedCrossRef Bathis H, Perlick L, Tingart M, Perlick C, Luring C, Grifka J (2005) Intraoperative cutting errors in total knee arthroplasty. Arch Orthop Trauma Surg 125:16–20PubMedCrossRef
2.
Zurück zum Zitat Bellemans J, Vandenneucker H, Vanlauwe J (2007) Robot-assisted total knee arthroplasty. Clin Orthop Relat Res 464:111–116PubMed Bellemans J, Vandenneucker H, Vanlauwe J (2007) Robot-assisted total knee arthroplasty. Clin Orthop Relat Res 464:111–116PubMed
3.
Zurück zum Zitat Decking J, Theis C, Achenbach T, Roth E, Nafe B, Eckardt A (2004) Robotic total knee arthroplasty: the accuracy of CT-based component placement. Acta Orthop Scand 75:573–579PubMedCrossRef Decking J, Theis C, Achenbach T, Roth E, Nafe B, Eckardt A (2004) Robotic total knee arthroplasty: the accuracy of CT-based component placement. Acta Orthop Scand 75:573–579PubMedCrossRef
4.
Zurück zum Zitat Delp SL, Stulberg SD, Davies B, Picard F, Leitner F (1998) Computer assisted knee replacement. Clin Orthop Relat Res 354:49–56PubMedCrossRef Delp SL, Stulberg SD, Davies B, Picard F, Leitner F (1998) Computer assisted knee replacement. Clin Orthop Relat Res 354:49–56PubMedCrossRef
5.
Zurück zum Zitat Fadda M, Marcacci M, Toksvig-Larsen S, Wang T, Meneghello R (1998) Improving accuracy of bone resections using robotics tool holder and a high speed milling cutting tool. J Med Eng Technol 22:280–284PubMedCrossRef Fadda M, Marcacci M, Toksvig-Larsen S, Wang T, Meneghello R (1998) Improving accuracy of bone resections using robotics tool holder and a high speed milling cutting tool. J Med Eng Technol 22:280–284PubMedCrossRef
6.
Zurück zum Zitat Griffin FM, Insall JN, Scuderi GR (2000) Accuracy of soft tissue balancing in total knee arthroplasty. J Arthroplasty 15:970–973PubMedCrossRef Griffin FM, Insall JN, Scuderi GR (2000) Accuracy of soft tissue balancing in total knee arthroplasty. J Arthroplasty 15:970–973PubMedCrossRef
7.
Zurück zum Zitat Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73:709–714PubMed Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73:709–714PubMed
8.
Zurück zum Zitat Jenny JY, Clemens U, Kohler S, Kiefer H, Konermann W, Miehlke RK (2005) Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: a case-control study of 235 cases compared with 235 conventionally implanted prostheses. J Arthroplasty 20:832–839PubMedCrossRef Jenny JY, Clemens U, Kohler S, Kiefer H, Konermann W, Miehlke RK (2005) Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: a case-control study of 235 cases compared with 235 conventionally implanted prostheses. J Arthroplasty 20:832–839PubMedCrossRef
9.
Zurück zum Zitat Laskin RS (2001) The Genesis total knee prosthesis: a 10-year followup study. Clin Orthop Relat Res 388:95–102PubMedCrossRef Laskin RS (2001) The Genesis total knee prosthesis: a 10-year followup study. Clin Orthop Relat Res 388:95–102PubMedCrossRef
10.
Zurück zum Zitat Laskin RS (2003) New techniques and concepts in total knee replacement. Clin Orthop Relat Res 416:151–153PubMedCrossRef Laskin RS (2003) New techniques and concepts in total knee replacement. Clin Orthop Relat Res 416:151–153PubMedCrossRef
11.
Zurück zum Zitat Laskin RS, Rieger MA (1989) The surgical technique for performing a total knee replacement arthroplasty. Orthop Clin North Am 20:31–48PubMed Laskin RS, Rieger MA (1989) The surgical technique for performing a total knee replacement arthroplasty. Orthop Clin North Am 20:31–48PubMed
12.
Zurück zum Zitat Lutzner J, Krummenauer F, Wolf C, Gunther KP, Kirschner S (2008) Computer-assisted and conventional total knee replacement: a comparative, prospective, randomised study with radiological and CT evaluation. J Bone Joint Surg Br 90:1039–1044PubMedCrossRef Lutzner J, Krummenauer F, Wolf C, Gunther KP, Kirschner S (2008) Computer-assisted and conventional total knee replacement: a comparative, prospective, randomised study with radiological and CT evaluation. J Bone Joint Surg Br 90:1039–1044PubMedCrossRef
13.
Zurück zum Zitat Mahaluxmivala J, Bankes MJ, Nicolai P, Aldam CH, Allen PW (2001) The effect of surgeon experience on component positioning in 673 press fit condylar posterior cruciate-sacrificing total knee arthroplasties. J Arthroplasty 16:635–640PubMedCrossRef Mahaluxmivala J, Bankes MJ, Nicolai P, Aldam CH, Allen PW (2001) The effect of surgeon experience on component positioning in 673 press fit condylar posterior cruciate-sacrificing total knee arthroplasties. J Arthroplasty 16:635–640PubMedCrossRef
14.
Zurück zum Zitat Maniar RN, Johorey AC, Pujary CT, Yadava AN (2011) Margin of error in alignment: a study undertaken when converting from conventional to computer-assisted total knee arthroplasty. J Arthroplasty 26:82–87 Maniar RN, Johorey AC, Pujary CT, Yadava AN (2011) Margin of error in alignment: a study undertaken when converting from conventional to computer-assisted total knee arthroplasty. J Arthroplasty 26:82–87
15.
Zurück zum Zitat Matsen FA 3rd, Garbini JL, Sidles JA, Pratt B, Baumgarten D, Kaiura R (1993) Robotic assistance in orthopaedic surgery. A proof of principle using distal femoral arthroplasty. Clin Orthop Relat Res 296:178–186PubMed Matsen FA 3rd, Garbini JL, Sidles JA, Pratt B, Baumgarten D, Kaiura R (1993) Robotic assistance in orthopaedic surgery. A proof of principle using distal femoral arthroplasty. Clin Orthop Relat Res 296:178–186PubMed
16.
Zurück zum Zitat Mielke RK, Clemens U, Jens JH, Kershally S (2001) Navigation in knee endoprosthesis implantation–preliminary experiences and prospective comparative study with conventional implantation technique. Z Orthop Ihre Grenzgeb 139:109–116PubMedCrossRef Mielke RK, Clemens U, Jens JH, Kershally S (2001) Navigation in knee endoprosthesis implantation–preliminary experiences and prospective comparative study with conventional implantation technique. Z Orthop Ihre Grenzgeb 139:109–116PubMedCrossRef
17.
Zurück zum Zitat Novotny J, Gonzalez MH, Amirouche FML, Li YC (2001) Geometric analysis of potential error in using femoral intramedullary guides in total knee arthroplasty. J Arthroplasty 16:641–647PubMedCrossRef Novotny J, Gonzalez MH, Amirouche FML, Li YC (2001) Geometric analysis of potential error in using femoral intramedullary guides in total knee arthroplasty. J Arthroplasty 16:641–647PubMedCrossRef
18.
Zurück zum Zitat Park SE, Lee CT (2007) Comparison of robotic-assisted and conventional manual implantation of a primary total knee arthroplasty. J Arthroplasty 22:1054–1059PubMedCrossRef Park SE, Lee CT (2007) Comparison of robotic-assisted and conventional manual implantation of a primary total knee arthroplasty. J Arthroplasty 22:1054–1059PubMedCrossRef
19.
Zurück zum Zitat Petersen TL, Engh GA (1988) Radiographic assessment of knee alignment after total knee arthroplasty. J Arthroplasty 3:67–72PubMedCrossRef Petersen TL, Engh GA (1988) Radiographic assessment of knee alignment after total knee arthroplasty. J Arthroplasty 3:67–72PubMedCrossRef
20.
Zurück zum Zitat Plaskos C, Hodgson AJ, Inkpen K, McGraw RW (2002) Bone cutting errors in total knee arthroplasty. J Arthroplasty 17:698–705PubMedCrossRef Plaskos C, Hodgson AJ, Inkpen K, McGraw RW (2002) Bone cutting errors in total knee arthroplasty. J Arthroplasty 17:698–705PubMedCrossRef
21.
Zurück zum Zitat Rand JA, Coventry MB (1988) Ten-year evaluation of geometric total knee arthroplasty. Clin Orthop Relat Res 232:168–173PubMed Rand JA, Coventry MB (1988) Ten-year evaluation of geometric total knee arthroplasty. Clin Orthop Relat Res 232:168–173PubMed
22.
Zurück zum Zitat Reed SC, Gollish J (1997) The accuracy of femoral intramedullary guides in total knee arthroplasty. J Arthroplasty 12:677–682PubMedCrossRef Reed SC, Gollish J (1997) The accuracy of femoral intramedullary guides in total knee arthroplasty. J Arthroplasty 12:677–682PubMedCrossRef
23.
Zurück zum Zitat Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 299:153–156PubMed Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 299:153–156PubMed
24.
Zurück zum Zitat Rodriguez JA, Bhende H, Ranawat CS (2001) Total condylar knee replacement: a 20-year followup study. Clin Orthop Relat Res 388:10–17PubMedCrossRef Rodriguez JA, Bhende H, Ranawat CS (2001) Total condylar knee replacement: a 20-year followup study. Clin Orthop Relat Res 388:10–17PubMedCrossRef
25.
Zurück zum Zitat Saragaglia D, Picard F, Chaussard C, Montbarbon E, Leitner F, Cinquin P (2001) Computer-assisted knee arthroplasty: comparison with a conventional procedure. Results of 50 cases in a prospective randomized study. Rev Chir Orthop Reparatrice Appar Mot 87:18–28PubMed Saragaglia D, Picard F, Chaussard C, Montbarbon E, Leitner F, Cinquin P (2001) Computer-assisted knee arthroplasty: comparison with a conventional procedure. Results of 50 cases in a prospective randomized study. Rev Chir Orthop Reparatrice Appar Mot 87:18–28PubMed
26.
Zurück zum Zitat Scott WN, Rubinstein M, Scuderi G (1988) Results after knee replacement with a posterior cruciate-substituting prosthesis. J Bone Joint Surg Am 70:1163–1173PubMed Scott WN, Rubinstein M, Scuderi G (1988) Results after knee replacement with a posterior cruciate-substituting prosthesis. J Bone Joint Surg Am 70:1163–1173PubMed
27.
Zurück zum Zitat Siebert W, Mai S, Kober R, Heeckt PF (2002) Technique and first clinical results of robot-assisted total knee replacement. Knee 9:173–180PubMedCrossRef Siebert W, Mai S, Kober R, Heeckt PF (2002) Technique and first clinical results of robot-assisted total knee replacement. Knee 9:173–180PubMedCrossRef
28.
Zurück zum Zitat Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support—A prospective, randomised study. J Bone Joint Surg Br 85B:830–835 Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support—A prospective, randomised study. J Bone Joint Surg Br 85B:830–835
29.
Zurück zum Zitat Takahashi T, Wada Y, Yamamoto H (1997) Soft-tissue balancing with pressure distribution during total knee arthroplasty. J Bone Joint Surg Br 79B:235–239CrossRef Takahashi T, Wada Y, Yamamoto H (1997) Soft-tissue balancing with pressure distribution during total knee arthroplasty. J Bone Joint Surg Br 79B:235–239CrossRef
30.
Zurück zum Zitat Van Ham G, Denis K, Vander Sloten J, Van Audekercke R, Van der Perre G, De Schutter J, Aertbelien E, Demey S, Bellemans J (1998) Machining and accuracy studies for a tibial knee implant using a force-controlled robot. Comput Aided Surg 3:123–133PubMedCrossRef Van Ham G, Denis K, Vander Sloten J, Van Audekercke R, Van der Perre G, De Schutter J, Aertbelien E, Demey S, Bellemans J (1998) Machining and accuracy studies for a tibial knee implant using a force-controlled robot. Comput Aided Surg 3:123–133PubMedCrossRef
Metadaten
Titel
Simultaneous bilateral total knee arthroplasty with robotic and conventional techniques: a prospective, randomized study
verfasst von
Eun-Kyoo Song
Jong-Keun Seon
Sang-Jin Park
Woo Bin Jung
Hyeong-Won Park
Geon Woo Lee
Publikationsdatum
01.07.2011
Verlag
Springer-Verlag
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 7/2011
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-011-1400-9

Weitere Artikel der Ausgabe 7/2011

Knee Surgery, Sports Traumatology, Arthroscopy 7/2011 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.