Skip to main content
Erschienen in: Herz 7/2016

16.02.2016 | Original articles

Single-catheter approach to pulmonary vein reisolation in selected patients

Data from a prospective registry

verfasst von: J. Lauschke, R. Schneider, J. Wissmann, T. Tischer, MD, D. Bänsch

Erschienen in: Herz | Ausgabe 7/2016

Einloggen, um Zugang zu erhalten

Abstract

Background

In addition to different types of single-tip ablation catheters for pulmonary vein (PV) reisolation, a newly developed circular mapping and ablation catheter (nMARQ®) has been available since 2013 and is currently used only in initial PV isolation procedures. In this prospective registry we present feasibility and efficacy data for PV reisolation procedures with a single-catheter approach (nMARQ®) compared with a standard approach using a single-tip ablation catheter and a circular mapping catheter.

Methods

We included 35 carefully selected patients in this prospective registry and assigned them in a 2:1 ratio to undergo either PV reisolation with a single-tip ablation catheter together with a steerable circular mapping catheter (group 1) or with the nMARQ®catheter only (group 2). The recurrence rate was calculated for atrial tachyarrhythmias with a duration of > 30 s during a mean follow-up of 12.7 months.

Results

Reisolation of all PVs was achieved in all patients of both groups. In group 2, all gaps could be correctly identified with the nMARQ® catheter. PV isolation was clearly visible on the nMARQ® catheter in all targeted veins. With the nMARQ® catheter the ablation time decreased significantly (6.3 ± 3.0 vs. 18.6 ± 13.9 min, p < 0.05). The recurrence rate of atrial fibrillation did not differ significantly between the two groups (37.5 vs. 45.5 %, p = 0.66).

Conclusion

In selected patients, a complete PV reisolation procedure is feasible with a singular circular mapping and ablation catheter. The 12-months success rate is comparable to a classic approach with a combination of a single-tip ablation catheter and a circular mapping catheter.
Literatur
1.
Zurück zum Zitat Mahida S, Hooks DA, Nentwich K, Ng GA, Grimaldi M, Shin DI, Derval N, Sacher F, Berte B, Yamashita S, Denis A, Hocini M, Deneke T, Haissaguerre M, Jais P (2015) nMARQ ablation for atrial fibrillation: results from a multicentre study. J Cardiovasc Electrophysiol 26:724–729CrossRefPubMed Mahida S, Hooks DA, Nentwich K, Ng GA, Grimaldi M, Shin DI, Derval N, Sacher F, Berte B, Yamashita S, Denis A, Hocini M, Deneke T, Haissaguerre M, Jais P (2015) nMARQ ablation for atrial fibrillation: results from a multicentre study. J Cardiovasc Electrophysiol 26:724–729CrossRefPubMed
2.
Zurück zum Zitat Arroja JD, Zimmermann M (2015) Phrenic nerve lesion: a potential complication of the nMARQ ablation technique. Int J Cardiol 180:91–92CrossRefPubMed Arroja JD, Zimmermann M (2015) Phrenic nerve lesion: a potential complication of the nMARQ ablation technique. Int J Cardiol 180:91–92CrossRefPubMed
3.
Zurück zum Zitat Rillig A, Lin T, Burchard A, Kamioka M, Heeger C, Makimoto H, Metzner A, Wissner E, Wohlmuth P, Ouyang F, Kuck KH, Tilz RR (2015) Modified energy settings are mandatory to minimize oesophageal injury using the novel multipolar irrigated radiofrequency ablation catheter for pulmonary vein isolation. Europace 17(3):396–402CrossRefPubMed Rillig A, Lin T, Burchard A, Kamioka M, Heeger C, Makimoto H, Metzner A, Wissner E, Wohlmuth P, Ouyang F, Kuck KH, Tilz RR (2015) Modified energy settings are mandatory to minimize oesophageal injury using the novel multipolar irrigated radiofrequency ablation catheter for pulmonary vein isolation. Europace 17(3):396–402CrossRefPubMed
4.
Zurück zum Zitat Rosso R, Halkin A, Michowitz Y, Belhassen B, Glick A, Viskin S (2014) Radiofrequency ablation of paroxysmal atrial fibrillation with the new irrigated multipolar nMARQ ablation catheter: verification of intracardiac signals with a second circular mapping catheter. Heart Rhythm 11(4):559–565CrossRefPubMed Rosso R, Halkin A, Michowitz Y, Belhassen B, Glick A, Viskin S (2014) Radiofrequency ablation of paroxysmal atrial fibrillation with the new irrigated multipolar nMARQ ablation catheter: verification of intracardiac signals with a second circular mapping catheter. Heart Rhythm 11(4):559–565CrossRefPubMed
5.
Zurück zum Zitat Zellerhoff S, Daly M, Lim HS, Denis A, Komatsu Y, Jesel L, Derval N, Sacher F, Cochet H, Knecht S, Yiem S, Hocini M, Haïssaguerre M, Jaïs P (2014) Pulmonary vein isolation using a circular, open irrigated mapping and ablation catheter (nMARQ): a report on feasibility and efficacy. Europace 16(9):1296–1303CrossRefPubMed Zellerhoff S, Daly M, Lim HS, Denis A, Komatsu Y, Jesel L, Derval N, Sacher F, Cochet H, Knecht S, Yiem S, Hocini M, Haïssaguerre M, Jaïs P (2014) Pulmonary vein isolation using a circular, open irrigated mapping and ablation catheter (nMARQ): a report on feasibility and efficacy. Europace 16(9):1296–1303CrossRefPubMed
6.
Zurück zum Zitat Scaglione M, Caponi D, Anselmino M, Di Clemente F, Blandino A, Ferraris F, Di Donna P, Ebrille E, Halimi F, Leclercq JF, Iunco C, Vaudagna C, Cesarani F, Gaita F (2014) Pulmonary vein isolation with a new multipolar irrigated radiofrequency ablation catheter (nMARQ™): feasibility, acute and short-term efficacy, safety, and impact on postablation silent cerebral ischemia. J Cardiovasc Electrophysiol 25(12):1299–1305PubMed Scaglione M, Caponi D, Anselmino M, Di Clemente F, Blandino A, Ferraris F, Di Donna P, Ebrille E, Halimi F, Leclercq JF, Iunco C, Vaudagna C, Cesarani F, Gaita F (2014) Pulmonary vein isolation with a new multipolar irrigated radiofrequency ablation catheter (nMARQ™): feasibility, acute and short-term efficacy, safety, and impact on postablation silent cerebral ischemia. J Cardiovasc Electrophysiol 25(12):1299–1305PubMed
7.
Zurück zum Zitat Shin DI, Kirmanoglou K, Eickholt C, Schmidt J, Clasen L, Butzbach B, Rassaf T, Merx M, Kelm M, Meyer C (2014) Initial results of using a novel irrigated multielectrode mapping and ablation catheter for pulmonary vein isolation. Heart Rhythm 11(3):375–383CrossRefPubMed Shin DI, Kirmanoglou K, Eickholt C, Schmidt J, Clasen L, Butzbach B, Rassaf T, Merx M, Kelm M, Meyer C (2014) Initial results of using a novel irrigated multielectrode mapping and ablation catheter for pulmonary vein isolation. Heart Rhythm 11(3):375–383CrossRefPubMed
8.
Zurück zum Zitat Deneke T, Schade A, Müller P, Schmitt R, Christopoulos G, Krug J, Szöllösi G, Mügge A, Kerber S, Nentwich K (2014) Acute safety and efficacy of a novel multipolar irrigated radiofrequency ablation catheter for pulmonary vein isolation. J Cardiovasc Electrophysiol 25(4):339–345CrossRefPubMed Deneke T, Schade A, Müller P, Schmitt R, Christopoulos G, Krug J, Szöllösi G, Mügge A, Kerber S, Nentwich K (2014) Acute safety and efficacy of a novel multipolar irrigated radiofrequency ablation catheter for pulmonary vein isolation. J Cardiovasc Electrophysiol 25(4):339–345CrossRefPubMed
9.
Zurück zum Zitat Stabile G, De Ruvo E, Grimaldi M, Rovaris G, Soldati E, Anselmino M, Solimene F, Iuliano A, Sciarra L, Schillaci V, Bongiorni MG, Gaita F, Calò L (2015) Safety and efficacy of pulmonary vein isolation using a circular, open-irrigated mapping and ablation catheter: a multicenter registry. Heart Rhythm. doi: 10.1016/j.hrthm.2015.05.025. (pii: S1547-5271(15)00628-1) Stabile G, De Ruvo E, Grimaldi M, Rovaris G, Soldati E, Anselmino M, Solimene F, Iuliano A, Sciarra L, Schillaci V, Bongiorni MG, Gaita F, Calò L (2015) Safety and efficacy of pulmonary vein isolation using a circular, open-irrigated mapping and ablation catheter: a multicenter registry. Heart Rhythm. doi: 10.​1016/​j.​hrthm.​2015.​05.​025. (pii: S1547-5271(15)00628-1)
10.
Zurück zum Zitat Lauschke J, Schneider R, Bänsch D (2015) Mapping and ablation of a left atrial macro reentrant tachycardia originating from the left superior pulmonary vein. Herz 40(Suppl 2):137–139CrossRefPubMed Lauschke J, Schneider R, Bänsch D (2015) Mapping and ablation of a left atrial macro reentrant tachycardia originating from the left superior pulmonary vein. Herz 40(Suppl 2):137–139CrossRefPubMed
Metadaten
Titel
Single-catheter approach to pulmonary vein reisolation in selected patients
Data from a prospective registry
verfasst von
J. Lauschke
R. Schneider
J. Wissmann
T. Tischer, MD
D. Bänsch
Publikationsdatum
16.02.2016
Verlag
Springer Medizin
Erschienen in
Herz / Ausgabe 7/2016
Print ISSN: 0340-9937
Elektronische ISSN: 1615-6692
DOI
https://doi.org/10.1007/s00059-016-4402-z

Weitere Artikel der Ausgabe 7/2016

Herz 7/2016 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.