Skip to main content
Erschienen in: Journal of Digital Imaging 3/2005

01.09.2005

Solution for Nonuniformities and Spatial Noise in Medical LCD Displays by Using Pixel-Based Correction

verfasst von: Tom Kimpe, Albert Xthona, Paul Matthijs, Lode De Paepe

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 3/2005

Einloggen, um Zugang zu erhalten

Abstract

Liquid crystal displays (LCD) are rapidly replacing cathode ray tube displays (CRT) for medical imaging. LCD technology has improved significantly in the last few years and has important advantages over CRT. However, there are still some aspects of LCD that raise questions as to the usefulness of liquid crystal displays for very subtle clinical diagnosis such as mammography. One drawback of modern LCD displays is the existence of spatial noise expressed as measurable stationary differences in the behavior of individual pixels. This type of noise can be described as a random stationary image superposed on top of the medical image being displayed. It is obvious that this noise image can make subtle structures invisible or add nonexistent patterns to the medical image. In the first case, subtle abnormalities in the medical image could remain undetected, whereas in the second case, it could result into a false positive. This paper describes a method to characterize the spatial noise present in high-resolution medical displays and a technique to solve the problem. A medical display with built-in compensation for the spatial noise at pixel level was developed and improved image quality is demonstrated.
Literatur
1.
Zurück zum Zitat Roehrig H, Krupinski EA, Chawla AS, Fan JH, Gandhi K: Spatial noise and threshold contrasts in LCD displays. SPIE Medical Imaging (San Diego, CA), February 2003, pp. 15–20 Roehrig H, Krupinski EA, Chawla AS, Fan JH, Gandhi K: Spatial noise and threshold contrasts in LCD displays. SPIE Medical Imaging (San Diego, CA), February 2003, pp. 15–20
2.
Zurück zum Zitat Fan J, Dallas WJ, Roehrig H, Gandhi K, Krupinski E: Spatial noise of high-resolution liquid-crystal displays for medical imaging: quantitative analysis, estimation and compensation. In: SPIE Medical Imaging Conference Workshop, San Diego, CA, pp. 14–19, February 2004 Fan J, Dallas WJ, Roehrig H, Gandhi K, Krupinski E: Spatial noise of high-resolution liquid-crystal displays for medical imaging: quantitative analysis, estimation and compensation. In: SPIE Medical Imaging Conference Workshop, San Diego, CA, pp. 14–19, February 2004
3.
Zurück zum Zitat Badano, A, Hipper, SJ, Jennings, RJ 2002Luminance effect on display resolution and noiseProc SPIE Int Soc Opt Eng4681305313 Badano, A, Hipper, SJ, Jennings, RJ 2002Luminance effect on display resolution and noiseProc SPIE Int Soc Opt Eng4681305313
4.
Zurück zum Zitat Krupinski, E, Roehrig, H 2002Pulmonary nodule detection and visual search: P45 and P104 monochrome versus color monitor displaysAcad Radiol9638645CrossRefPubMed Krupinski, E, Roehrig, H 2002Pulmonary nodule detection and visual search: P45 and P104 monochrome versus color monitor displaysAcad Radiol9638645CrossRefPubMed
5.
Zurück zum Zitat van Engen R, Young K, Bosmans H, Thijssen M, Visser R, Oostveen L, Geertse T, Bijkerk R, Heid P: Addendum on digital mammography to chapter three of the European Protocol for the quality control of the physical and technical aspects of mammography screening, November 2003 van Engen R, Young K, Bosmans H, Thijssen M, Visser R, Oostveen L, Geertse T, Bijkerk R, Heid P: Addendum on digital mammography to chapter three of the European Protocol for the quality control of the physical and technical aspects of mammography screening, November 2003
6.
Zurück zum Zitat Roehrig H, Krupinski EA, Fan J, Chawla A, Gandhi K: Physical and psychophysical evaluation of LCD noise. 18th International Computer Assisted Radiology and Surgery Conference, Chicago, IL, pp. 23–26, June 2004 Roehrig H, Krupinski EA, Fan J, Chawla A, Gandhi K: Physical and psychophysical evaluation of LCD noise. 18th International Computer Assisted Radiology and Surgery Conference, Chicago, IL, pp. 23–26, June 2004
Metadaten
Titel
Solution for Nonuniformities and Spatial Noise in Medical LCD Displays by Using Pixel-Based Correction
verfasst von
Tom Kimpe
Albert Xthona
Paul Matthijs
Lode De Paepe
Publikationsdatum
01.09.2005
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 3/2005
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-005-2939-0

Weitere Artikel der Ausgabe 3/2005

Journal of Digital Imaging 3/2005 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.