Skip to main content
Erschienen in: BMC Ophthalmology 1/2018

Open Access 01.12.2018 | Research article

Species-specific characteristics of the biofilm generated in silicone tube: an in vitro study

verfasst von: Dong Ju Kim, Joo-Hee Park, Minwook Chang

Erschienen in: BMC Ophthalmology | Ausgabe 1/2018

Abstract

Background

To investigate characteristics of biofilm which is usually found in silicone tube for nasolacrimal duct surgery and can be the root of chronic bacterial infections eventually resulted in surgical failure.

Methods

To form a biofilm, sterile silicone tube was placed in culture media of Staphylococcus aureus, Corynebacterium matruchotii, Pseudomonas aeruginosa, or Streptococcus pneumonia. Biofilms formed on these silicone tubes were fixed with 95% ethanol and stained with 0.1% crystal violet. After staining, the optical densities of biofilms were measured using spectrophotometer on a weekly basis for 12 weeks.

Results

Staphylococcus aureus group and Pseudomonas aeruginosa group formed significantly more amounts of biofilms compared to the control group. The maximum optical densities of the two groups were found on week 3–4 followed by a tendency of decrease afterwards. However, the amounts of biofilms formed in other groups of silicone tubes were not statistically significant from that of the control group.

Conclusions

Bacterial species that could form biofilm on silicone tube included Staphylococcus aureus (week 3) and Pseudomonas aeruginosa (Week 4). It is important to first consider that the cause of infection around 1 month after silicone tube intubation can be Staphylococcus aureus and Pseudomonas aeruginosa.
Abkürzungen
DCR
dacryocystorhinostomy
NLDO
nasolacrimal duct obstruction
NTM
nontuberculosis mycobacteria
OD
optical density

Background

Nasolacrimal duct obstruction (NLDO) mainly occurs in inflammation and fibrosis of lacrimal system. Either external or endoscopic dacryocystorhinostomy (DCR) is commonly used for NLDO [13]. DCR with silicone tube intubation has been commonly used to treat NLDO [48]. Although the beneficial effects of silicone tube intubation remain controversial [4, 9], silicone tube intubation is usually performed in order to maintain ostium patency and reinstate lacrimal drainage function, especially in case of distal or common canalicular obstruction [10, 11]. However, silicone tube intubation is associated with complications such as granulation formation, fibrosis and inflammation of nasolacrimal system, patient discomfort, infection of silicone tube, and cost related to intubation [12, 13]. Infection of silicone tube can result in postoperative failure [14, 15]. Bacteria can form biofilms, a complex of microbial communities enclosed in an exopolysaccharide matrix adherent to surface of prosthetics or living organism [16]. Biofilms enable bacteria to survive by reducing their metabolic needs and increasing their inherent resistance to antimicrobial agents. Biofilms formed on silicone tube could be the root of persistent and chronic bacterial infections. They can lead to chronic inflammatory response [17, 18]. Thus, it is important to find out the pathogen that formed biofilm on silicone tube.
In previous studies, both Gram-positive and Gram-negative bacteria have been isolated from extubated silicone tubes. Lee et al. [19] have reported culture positivity of 60% from extruded polyurethane nasolacrimal stents, with Pseudomonas aeruginosa being isolated from 40% of these stents. Ali et al. [20] have reported a positive culture of 94%, with Pseudomonas aeruginosa being isolated in 24% of cases. Kim et al. [14] have reported a positive culture of 94.9% from extubated silicone tubes, with 73% of the isolated bacteria being Gram-positive. They have also reported that Pseudomonas aeruginosa is associated with complications such as prolonged intubation, revision surgeries, and surgery failure [14].
The objective of this study was to investigate the characteristics of biofilms formed by four bacteria species (Staphylococcus aureus, Corynebacterium matruchotii, Pseudomonas aeruginosa, and Streptococcus pneumonia) usually found in silicone tubes used for nasolacrimal duct surgery [14, 19, 20]. The results of this study will improve our understanding on the characteristics of biofilms depending on bacteria, such as the amount of biofilms formed and the peak time of biofilm formation. These information will help us decide the treatment plan such as prophylactic use of antibiotics, the timing of stent removal and may aid in development of future strategies in treating silicone tube infection.

Methods

Bacteria culture

Staphylococcus aureus (KTCT#1621, ATCC#25923), Corynebacterium matruchotii (KTCT#19325,) Pseudomonas aeruginosa (KTCT#2513, ATCC#9027), and Streptococcus pneumonia (KTCT#5765, ATCC#BAA-960) were used in this study. Staphylococcus aureus, Corynebacterium matruchotii, and Streptococcus pneumonia are Gram-positive bacteria while Pseudomonas aeruginosa is Gram-negative bacterium. All bacteria were obtained from the Korean Collection for Type cultures (KCTC). Bacteria were maintained in Nutrient broth media (234,000; BD), BBL Trypticase soy broth media (211,768; BD), or Bacto Tryptic soy broth (211,825; BD), and cultured in an incubator at 37 °C except Streptococcus pneumonia. Streptococcus pneumonia was cultured in an incubator at 37 °C in an atmosphere of 5% CO2.

Biofilm formation on silicon tube

Silicon tube (60–411-40; HelixMark) was cut into 2 cm in length and autoclaved. One silicone tube was cut into 6 pieces. Each group had 6 samples. To maintain the culture condition, we change the media as follows. Staphylococcus aureus culture media (Nutrient Broth media, 37 °C) was changed every 2 days. Corynebacterium matruchotii culture media (Trypticase soy broth, 37 °C) was changed every 4 days. Pseudomonas aeruginosa culture media (Trypticase soy broth, 37 °C) was changed every 2 days. Streptococcus pneumonia culture media (Bacto Tryptic soy broth, in 5% carbon dioxide at 37 °C) was changed every 4 days. The control group was not in contact with the bacteria in culture media (Nutrient Broth media).

Biofilm formation measurement on silicon tube

Silicon tubes incubated in cultured media were moved to new well and washed three times with distilled water. Biofilms formed on these silicon tubes were fixed with 95% ethanol. Tubes were washed twice with distilled water and stained with 0.1% crystal violet (V5265; SIGMA) for 30 min. After staining, silicon tubes were washed three times with distilled water. The crystal violet remained inside the silicon tube was removed using 22G syringe. These silicone tubes were dried on paper towel. The stained silicone tube was cut into 5 mm in thickness. These 5 mm tubes were placed in 96-well plate and filled with 95% ethanol (100 μl). The 96-well plate was sealed and incubated at 4 °C for 24 h. The optical density of the solubilized crystal violet in each well was then measured at wavelength of 570 nm using a spectrophotometer (SpectraMax plus 384 microplate reader, Molecular Devices, Sunnyvale, CA, USA). Each sample (Fig. 1) was measured for 12 weeks.

Statistical analysis

The normality of data was checked by using Sapiro-Wilk test. All data showed normal distribution. The sphericity of the data was checked using Mauchly’s test. Repeated measure analysis of variance (RM-ANOVA) was used to compare time and optical density between control and bacteria. Post hoc test was conducted using the Bonferroni procedure. Statistical analyses were carried out using IBM SPSS ver. 21.0(IBM Corp., Armonk, NY, USA). P-value less than 0.05 was considered as statistically significant.

Results

Six tubes from each group were evaluated for 12 weeks. Staphylococcus aureus group (P = 0.000, RM-ANOVA) and Pseudomonas aeruginosa (P = 0.004, RM-ANOVA) group formed significantly higher optical density of biofilms compared to control groups. Specifically, significantly higher optical densities were observed at week 3, 4, 5, 8 in Pseudomonas aeruginosa group and at week 3, 4, 6 in Staphylococcus aureus group (Table 1, Fig. 2).
Table 1
Change of optical density according to time
 
Optical density
Control
P.aeruginosa
C.matruchotti
S.aureus
S.pneumoniae
Week 1
0.1394 ± 0.0378
0.2154 ± 0.0740
0.1257 ± 0.0401
0.1272 ± 0.0406
0.2474 ± 0.1002
Week 2
0.1003 ± 0.0007
0.2299 ± 0.1030
0.0913 ± 0.0151
0.2583 ± 0.1249
0.1058 ± 0.0029
Week 3
0.1209 ± 0.0447
0.3414 ± 0.1359*
0.1301 ± 0.0459
1.5018 ± 0.2985*
0.0944 ± 0.0084
Week 4
0.1008 ± 0.0301
0.9106 ± 1.0651*
0.1388 ± 0.0517
0.4858 ± 0.1167*
0.1438 ± 0.0416
Week 5
0.0963 ± 0.0352
0.2415 ± 0.0691*
0.0967 ± 0.0228
0.2147 ± 0.0679
0.0863 ± 0.0074
Week 6
0.0902 ± 0.0028
0.1326 ± 0.1189
0.0946 ± 0.0034
0.8363 ± 0.2872*
0.1317 ± 0.0389
Week 7
0.1157 ± 0.0319
0.1659 ± 0.0416
0.1322 ± 0.0344
0.2579 ± 0.1053
0.1021 ± 0.0202
Week 8
0.0834 ± 0.0053
0.3392 ± 0.0757*
0.1094 ± 0.0332
0.1672 ± 0.0385
0.0911 ± 0.0222
Week 9
0.2378 ± 0.0257
0.1874 ± 0.0480
0.1616 ± 0.0410
0.4937 ± 0.1167
0.2217 ± 0.0179
Week 10
0.2635 ± 0.0613
0.2711 ± 0.0621
0.2808 ± 0.0388
0.3295 ± 0.0653
0.2539 ± 0.0357
Week 11
0.2412 ± 0.0403
0.3468 ± 0.0742
0.3209 ± 0.0746
0.3978 ± 0.0905
0.2320 ± 0.0035
Week 12
0.1701 ± 0.0461
0.1801 ± 0.0629
0.1712 ± 0.0519
0.7783 ± 0.2538
0.1738 ± 0.0210
Values are presented as mean ± standard deviation
*RM-ANOVA with post-hoc by Bonferroni (P < 0.004)
The maximum optical density of Pseudomonas aeruginosa was found in week 4. It was then decreased afterwards but increased temporarily in week 8. Similarly, the maximum optical density of Staphylococcus aureus was found in week 3 with a tendency to decrease afterwards. A second peak occurred in week 6. The amounts of biofilms formed by Corynebacterium matruchotii and Streptococcus pneumonia were not significantly (P > 0.05, RM-ANOVA) different from those of the control groups.

Discussion

Biofilm have been associated with ocular prosthetic materials infection [21]. A biofilm is a complex organization of bacteria adherent to a biotic or an abiotic surface by living together in organized structures and communicating with one another in a co-operative manner [22, 23]. The bacteria self-produced polymeric matrix is embedded. This structure provides many advantages to bacteria, such as helping them endure environmental changes, resistant to host defense mechanisms, and resist conventional antibiotics. The presence of biofilm on a biomaterial could eventually lead to chronic inflammation and serve as a reservoir for bacteria. Therefore, bacterial biofilm has been increasingly recognized as playing an important role in surgical failure [24].
DCR and their surgical variants have been known as effective treatment for nasolacrimal duct problem. Among these surgical variants, nasolacrimal tube insertion is one of the most popular methods. However, complications related to postoperative infections associated with biofilms formed on tubes have been recently reported [1215, 20].
Kim et al. [14] have reported that Pseudomonas aeruginosa infection is significantly associated with membranous obstruction of nasal mucosa, prolonged silicone intubation, and surgical failure. Balikoglu-Yilmaz et al. [25] have reported that Staphylococcus epidermidis and Pseudomonas aeruginosa are commonly culture positive on lacrimal stent. Ali et al. [20] have also reported that the most common bacterial organisms on lacrimal stents are Pseudomonas aeruginosa and Staphylococcus aureus. However, biofilm may be formed even if the culture was negative for bacterial growth. [26] due to limitation of conventional culture techniques [27]. Therefore, the possibility of chronic infection caused by biofilm could not be ruled out when the culture was negative.
Bacteriology of dacyrocystitis has been gradually changed. Imatiaz A. Chaudhry et al. and Hartikainen J et al. have reported that Staphylococcus species were usually the most common organisms in Gram-positive bacteria while Pseudomonas aeruginosa and Haemophilus species were common Gram-negative bacteria found in dacyrocystitis. Corynebacterium species were also detected [2830]. Also, Pseudomonas aeruginosa and Staphylococcus aureus are well known producers of biofilms in paranasal sinus disease [31]. However, according to studies by David B. Samimi et al., nontuberculosis mycobacteria(NTM) was detected in silicone tube. Particularly, NTM was found in patients with clinically significant infection of silicone tube. But this study was a single institutional study in South Florida, so it is difficult to apply it to other region [32, 33]. Considering all above studies, we selected four bacterial species in this study, including Staphylococcus aureus and Pseudomonas aeruginosa.
The optical densities of the Staphylococcus aureus group and the Pseudomonas aeruginosa group were found to be higher than those of the control groups. This result suggests that the formation of biofilm depends on bacteria species. In terms of the amount of biofilm formed, the maximum value was achieved in 3 or 4 weeks with a tendency of decrease afterwards. A secondary peak occurred at 3 or 4 weeks after the first peak. This result can be used as a basis to use prophylactic antibiotics for 4 weeks to 8 weeks after silicone tube intubation. Once infection occurs, to treat infection and prevent recurrences, the prosthetic medical devices must be removed and antibiotics must be used at stronger doses or more often. It has been reported that if lacrimal stents are left longer than 1 month, biofilms may influence postoperative healing and the ultimate outcome [34]. Our results also support the use of prophylactic antibiotics after surgery.
This study has some limitations. First, this is an in-vitro study. Therefore, interaction of bacteria and immune system could not be evaluated. The causative relationship between biofilm and surgical failure was difficult to determine. To evaluate this, an in-vivo study is required. Second, many studies have reported that both bacteria and fungus are isolated from silicone stents, with fungus being isolated from 3.8% to 60% of cases [14, 20, 26, 34]. Symbiotic biofilms are more resistant to antibiotics with more complicated complex compared to non-symbiotic biofilms [35, 36]. However, we only investigated bacteria in this study.
Third, there are many methods for quantifying and detecting biofilms such as scanning electron microscopy morphology as a predictor [32, 37], biomass using confocal scanning laser microscope [34]. However, there is no standard method. We selected optical density using spectrophotometer at wavelength of 570 nm. This method had limited ability in assessing the depth of biofilm, thickness, or maturity. However, it can be quantified for comparison purpose and one study reported that crystal violet detect biofilm matrix for monitoring overall biofilm architecture [38, 39]. Antibiotic sensitivity or resistance associated with optical density could provide better information on treatment decision.

Conclusions

In conclusion, this study found that, of four bacterial species tested, Staphylococcus aureus and Pseudomonas aeruginosa could significantly form biofilms on silicone tube. The maximum optical density of biofilms occurred at around 1 month after incubating silicone tubes with bacterial culture media. A secondary peak occurred at around 2 months after incubation. On this basis, we first consider that the cause of infection around 1 month after silicone tube intubation can be Staphylococcus aureus and Pseudomonas aeruginosa.

Acknowledgements

This work was supported by the Dongguk University Research Fund (grant No. S-2014-G0001-00024). The funding organization had no role in the design or conduct of this research.

Availability of data and materials

The data is in the hospital, but we cannot use share program due to privacy issue in the hospital. So all data are available upon request to the corresponding author at mdjacob@naver.com
Not applicable.
Not applicable.

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
Literatur
1.
Zurück zum Zitat Huang J, Malek J, Chin D, Snidvongs K, Wilcsek G, Tumuluri K, Sacks R, Harvey RJ. Systematic review and meta-analysis on outcomes for endoscopic versus external dacryocystorhinostomy. Orbit. 2014;33(2):81–90.CrossRefPubMed Huang J, Malek J, Chin D, Snidvongs K, Wilcsek G, Tumuluri K, Sacks R, Harvey RJ. Systematic review and meta-analysis on outcomes for endoscopic versus external dacryocystorhinostomy. Orbit. 2014;33(2):81–90.CrossRefPubMed
2.
Zurück zum Zitat Ben Simon GJ, Joseph J, Lee S, Schwarcz RM, McCann JD, Goldberg RA. External versus endoscopic dacryocystorhinostomy for acquired nasolacrimal duct obstruction in a tertiary referral center. Ophthalmology. 2005;112(8):1463–8.CrossRefPubMed Ben Simon GJ, Joseph J, Lee S, Schwarcz RM, McCann JD, Goldberg RA. External versus endoscopic dacryocystorhinostomy for acquired nasolacrimal duct obstruction in a tertiary referral center. Ophthalmology. 2005;112(8):1463–8.CrossRefPubMed
3.
Zurück zum Zitat Jawaheer L, MacEwen CJ, Anijeet D. Endonasal versus external dacryocystorhinostomy for nasolacrimal duct obstruction. Cochrane Database Syst Rev. 2017;2:CD007097.PubMed Jawaheer L, MacEwen CJ, Anijeet D. Endonasal versus external dacryocystorhinostomy for nasolacrimal duct obstruction. Cochrane Database Syst Rev. 2017;2:CD007097.PubMed
4.
Zurück zum Zitat Chong KK, Lai FH, Ho M, Luk A, Wong BW, Young A. Randomized trial on silicone intubation in endoscopic mechanical dacryocystorhinostomy (SEND) for primary nasolacrimal duct obstruction. Ophthalmology. 2013;120(10):2139–45.CrossRefPubMed Chong KK, Lai FH, Ho M, Luk A, Wong BW, Young A. Randomized trial on silicone intubation in endoscopic mechanical dacryocystorhinostomy (SEND) for primary nasolacrimal duct obstruction. Ophthalmology. 2013;120(10):2139–45.CrossRefPubMed
5.
Zurück zum Zitat Gu Z, Cao Z. Silicone intubation and endoscopic dacryocystorhinostomy: a meta-analysis. J Otolaryngol Head Neck Surg. 2010;39(6):710–3.PubMed Gu Z, Cao Z. Silicone intubation and endoscopic dacryocystorhinostomy: a meta-analysis. J Otolaryngol Head Neck Surg. 2010;39(6):710–3.PubMed
6.
Zurück zum Zitat Marcet MM, Kuk AK, Phelps PO. Evidence-based review of surgical practices in endoscopic endonasal dacryocystorhinostomy for primary acquired nasolacrimal duct obstruction and other new indications. Curr Opin Ophthalmol. 2014;25(5):443–8.CrossRefPubMed Marcet MM, Kuk AK, Phelps PO. Evidence-based review of surgical practices in endoscopic endonasal dacryocystorhinostomy for primary acquired nasolacrimal duct obstruction and other new indications. Curr Opin Ophthalmol. 2014;25(5):443–8.CrossRefPubMed
7.
Zurück zum Zitat Xie C, Zhang L, Liu Y, Ma H, Li S. Comparing the success rate of Dacryocystorhinostomy with and without silicone intubation: a trial sequential analysis of randomized control trials. Sci Rep. 2017;7(1):1936.CrossRefPubMedPubMedCentral Xie C, Zhang L, Liu Y, Ma H, Li S. Comparing the success rate of Dacryocystorhinostomy with and without silicone intubation: a trial sequential analysis of randomized control trials. Sci Rep. 2017;7(1):1936.CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Feng YF, Cai JQ, Zhang JY, Han XH. A meta-analysis of primary dacryocystorhinostomy with and without silicone intubation. Can J Ophthalmol. 2011;46(6):521–7.CrossRefPubMed Feng YF, Cai JQ, Zhang JY, Han XH. A meta-analysis of primary dacryocystorhinostomy with and without silicone intubation. Can J Ophthalmol. 2011;46(6):521–7.CrossRefPubMed
9.
Zurück zum Zitat Syed MI, Head EJ, Madurska M, Hendry J, Erikitola OC, Cain AJ. Endoscopic primary dacryocystorhinostomy: are silicone tubes needed? Our experience in sixty three patients. Clin Otolaryngol. 2013;38(5):406–10.CrossRefPubMed Syed MI, Head EJ, Madurska M, Hendry J, Erikitola OC, Cain AJ. Endoscopic primary dacryocystorhinostomy: are silicone tubes needed? Our experience in sixty three patients. Clin Otolaryngol. 2013;38(5):406–10.CrossRefPubMed
10.
Zurück zum Zitat Paik JS, Cho WK, Yang SW. Bicanalicular double silicone stenting in endoscopic dacryocystorhinostomy with lacrimal trephination in distal or common canalicular obstruction. Eur Arch Otorhinolaryngol. 2012;269(6):1605–11.CrossRefPubMed Paik JS, Cho WK, Yang SW. Bicanalicular double silicone stenting in endoscopic dacryocystorhinostomy with lacrimal trephination in distal or common canalicular obstruction. Eur Arch Otorhinolaryngol. 2012;269(6):1605–11.CrossRefPubMed
11.
Zurück zum Zitat Buttanri IB, Serin D, Karslioglu S, Akbaba M, Fazil K, Acar B, Sevim MS. The outcome of silicone intubation and tube removal in external dacryocystorhinostomy patients with distal canalicular obstruction. Eur J Ophthalmol. 2012;22(6):878–81.CrossRefPubMed Buttanri IB, Serin D, Karslioglu S, Akbaba M, Fazil K, Acar B, Sevim MS. The outcome of silicone intubation and tube removal in external dacryocystorhinostomy patients with distal canalicular obstruction. Eur J Ophthalmol. 2012;22(6):878–81.CrossRefPubMed
12.
Zurück zum Zitat Smirnov G, Tuomilehto H, Terasvirta M, Nuutinen J, Seppa J. Silicone tubing is not necessary after primary endoscopic dacryocystorhinostomy: a prospective randomized study. Am J Rhinol. 2008;22(2):214–7.CrossRefPubMed Smirnov G, Tuomilehto H, Terasvirta M, Nuutinen J, Seppa J. Silicone tubing is not necessary after primary endoscopic dacryocystorhinostomy: a prospective randomized study. Am J Rhinol. 2008;22(2):214–7.CrossRefPubMed
13.
Zurück zum Zitat Smirnov G, Tuomilehto H, Terasvirta M, Nuutinen J, Seppa J. Silicone tubing after endoscopic dacryocystorhinostomy: is it necessary? Am J Rhinol. 2006;20(6):600–2.CrossRefPubMed Smirnov G, Tuomilehto H, Terasvirta M, Nuutinen J, Seppa J. Silicone tubing after endoscopic dacryocystorhinostomy: is it necessary? Am J Rhinol. 2006;20(6):600–2.CrossRefPubMed
14.
Zurück zum Zitat Kim SE, Lee SJ, Lee SY, Yoon JS. Clinical significance of microbial growth on the surfaces of silicone tubes removed from dacryocystorhinostomy patients. Am J Ophthalmol. 2012;153(2):253–7. e251CrossRefPubMed Kim SE, Lee SJ, Lee SY, Yoon JS. Clinical significance of microbial growth on the surfaces of silicone tubes removed from dacryocystorhinostomy patients. Am J Ophthalmol. 2012;153(2):253–7. e251CrossRefPubMed
15.
Zurück zum Zitat Ibanez A, Trinidad A, Garcia-Berrocal JR, Gomez D, San Roman J, Ramirez-Camacho R. Biofilm colonisation in nasolacrimal stents. B-ENT. 2011;7(1):7–10.PubMed Ibanez A, Trinidad A, Garcia-Berrocal JR, Gomez D, San Roman J, Ramirez-Camacho R. Biofilm colonisation in nasolacrimal stents. B-ENT. 2011;7(1):7–10.PubMed
17.
Zurück zum Zitat Costerton JW. Introduction to biofilm. Int J Antimicrob Agents. 1999;11(3–4):217–21. discussion 237-219CrossRefPubMed Costerton JW. Introduction to biofilm. Int J Antimicrob Agents. 1999;11(3–4):217–21. discussion 237-219CrossRefPubMed
18.
Zurück zum Zitat Davies D. Understanding biofilm resistance to antibacterial agents. Nat Rev Drug Discov. 2003;2(2):114–22.CrossRefPubMed Davies D. Understanding biofilm resistance to antibacterial agents. Nat Rev Drug Discov. 2003;2(2):114–22.CrossRefPubMed
19.
Zurück zum Zitat Lee JH, Kang MS, Yang JW. Clinicopathologic findings after nasolacrimal polyurethane stent implantations. Korean J Ophthalmol. 2005;19(4):252–7.CrossRefPubMed Lee JH, Kang MS, Yang JW. Clinicopathologic findings after nasolacrimal polyurethane stent implantations. Korean J Ophthalmol. 2005;19(4):252–7.CrossRefPubMed
20.
Zurück zum Zitat Ali MJ, Manderwad G, Naik MN. The microbiological spectrum and antibiotic sensitivity profile of extubated silicone stents following dacryocystorhinostomy. Orbit. 2013;32(5):298–303.CrossRefPubMed Ali MJ, Manderwad G, Naik MN. The microbiological spectrum and antibiotic sensitivity profile of extubated silicone stents following dacryocystorhinostomy. Orbit. 2013;32(5):298–303.CrossRefPubMed
21.
Zurück zum Zitat Zegans ME, Becker HI, Budzik J, O'Toole G. The role of bacterial biofilms in ocular infections. DNA Cell Biol. 2002;21(5–6):415–20.CrossRefPubMed Zegans ME, Becker HI, Budzik J, O'Toole G. The role of bacterial biofilms in ocular infections. DNA Cell Biol. 2002;21(5–6):415–20.CrossRefPubMed
22.
Zurück zum Zitat Mirani ZA, Aziz M, Khan MN, Lal I, Hassan NU, Khan SI. Biofilm formation and dispersal of Staphylococcus aureus under the influence of oxacillin. Microb Pathog. 2013;61-62:66–72.CrossRefPubMed Mirani ZA, Aziz M, Khan MN, Lal I, Hassan NU, Khan SI. Biofilm formation and dispersal of Staphylococcus aureus under the influence of oxacillin. Microb Pathog. 2013;61-62:66–72.CrossRefPubMed
23.
Zurück zum Zitat Veerachamy S, Yarlagadda T, Manivasagam G, Yarlagadda PK. Bacterial adherence and biofilm formation on medical implants: a review. Proc Inst Mech Eng H. 2014;228(10):1083–99.CrossRefPubMed Veerachamy S, Yarlagadda T, Manivasagam G, Yarlagadda PK. Bacterial adherence and biofilm formation on medical implants: a review. Proc Inst Mech Eng H. 2014;228(10):1083–99.CrossRefPubMed
24.
Zurück zum Zitat Costerton JW, Stewart PS, Greenberg EP. Bacterial biofilms: a common cause of persistent infections. Science. 1999;284(5418):1318–22.CrossRefPubMed Costerton JW, Stewart PS, Greenberg EP. Bacterial biofilms: a common cause of persistent infections. Science. 1999;284(5418):1318–22.CrossRefPubMed
25.
Zurück zum Zitat Balikoglu-Yilmaz M, Yilmaz T, Cetinel S, Taskin U, Banu Esen A, Taskapili M, Kose T. Comparison of scanning electron microscopy findings regarding biofilm colonization with microbiological results in nasolacrimal stents for external, endoscopic and transcanalicular dacryocystorhinostomy. Int J Ophthalmol. 2014;7(3):534–40.PubMedPubMedCentral Balikoglu-Yilmaz M, Yilmaz T, Cetinel S, Taskin U, Banu Esen A, Taskapili M, Kose T. Comparison of scanning electron microscopy findings regarding biofilm colonization with microbiological results in nasolacrimal stents for external, endoscopic and transcanalicular dacryocystorhinostomy. Int J Ophthalmol. 2014;7(3):534–40.PubMedPubMedCentral
26.
Zurück zum Zitat Parsa K, Schaudinn C, Gorur A, Sedghizadeh PP, Johnson T, Tse DT, Costerton JW. Demonstration of bacterial biofilms in culture-negative silicone stent and jones tube. Ophthal Plast Reconstr Surg. 2010;26(6):426–30.CrossRefPubMed Parsa K, Schaudinn C, Gorur A, Sedghizadeh PP, Johnson T, Tse DT, Costerton JW. Demonstration of bacterial biofilms in culture-negative silicone stent and jones tube. Ophthal Plast Reconstr Surg. 2010;26(6):426–30.CrossRefPubMed
27.
Zurück zum Zitat Fux CA, Costerton JW, Stewart PS, Stoodley P. Survival strategies of infectious biofilms. Trends Microbiol. 2005;13(1):34–40.CrossRefPubMed Fux CA, Costerton JW, Stewart PS, Stoodley P. Survival strategies of infectious biofilms. Trends Microbiol. 2005;13(1):34–40.CrossRefPubMed
29.
Zurück zum Zitat Sainju R, Franzco AA, Shrestha MK, Ruit S. Microbiology of dacryocystitis among adults population in southern Australia. Nepal Med Coll J. 2005;7(1):18–20.PubMed Sainju R, Franzco AA, Shrestha MK, Ruit S. Microbiology of dacryocystitis among adults population in southern Australia. Nepal Med Coll J. 2005;7(1):18–20.PubMed
30.
Zurück zum Zitat Chaudhry IA, Shamsi FA, Al-Rashed W. Bacteriology of chronic dacryocystitis in a tertiary eye care center. Ophthal Plast Reconstr Surg. 2005;21(3):207–10.CrossRefPubMed Chaudhry IA, Shamsi FA, Al-Rashed W. Bacteriology of chronic dacryocystitis in a tertiary eye care center. Ophthal Plast Reconstr Surg. 2005;21(3):207–10.CrossRefPubMed
31.
Zurück zum Zitat Bendouah Z, Barbeau J, Hamad WA, Desrosiers M. Biofilm formation by Staphylococcus aureus and Pseudomonas aeruginosa is associated with an unfavorable evolution after surgery for chronic sinusitis and nasal polyposis. Otolaryngol Head Neck Surg. 2006;134(6):991–6.CrossRefPubMed Bendouah Z, Barbeau J, Hamad WA, Desrosiers M. Biofilm formation by Staphylococcus aureus and Pseudomonas aeruginosa is associated with an unfavorable evolution after surgery for chronic sinusitis and nasal polyposis. Otolaryngol Head Neck Surg. 2006;134(6):991–6.CrossRefPubMed
32.
Zurück zum Zitat Samimi DB, Ediriwickrema LS, Bielory BP, Miller D, Lee W, Johnson TE. Microbiology and biofilm trends of silicone lacrimal implants: comparing infected versus routinely removed stents. Ophthal Plast Reconstr Surg. 2016;32(6):452–7.CrossRefPubMed Samimi DB, Ediriwickrema LS, Bielory BP, Miller D, Lee W, Johnson TE. Microbiology and biofilm trends of silicone lacrimal implants: comparing infected versus routinely removed stents. Ophthal Plast Reconstr Surg. 2016;32(6):452–7.CrossRefPubMed
33.
Zurück zum Zitat Samimi DB, Bielory BP, Miller D, Johnson TE. Microbiologic trends and biofilm growth on explanted periorbital biomaterials: a 30-year review. Ophthal Plast Reconstr Surg. 2013;29(5):376–81.CrossRefPubMed Samimi DB, Bielory BP, Miller D, Johnson TE. Microbiologic trends and biofilm growth on explanted periorbital biomaterials: a 30-year review. Ophthal Plast Reconstr Surg. 2013;29(5):376–81.CrossRefPubMed
34.
Zurück zum Zitat Murphy J, Ali MJ, Psaltis AJ. Biofilm quantification on nasolacrimal Silastic stents after Dacryocystorhinostomy. Ophthal Plast Reconstr Surg. 2015;31(5):396–400.CrossRefPubMed Murphy J, Ali MJ, Psaltis AJ. Biofilm quantification on nasolacrimal Silastic stents after Dacryocystorhinostomy. Ophthal Plast Reconstr Surg. 2015;31(5):396–400.CrossRefPubMed
35.
Zurück zum Zitat Peleg AY, Hogan DA, Mylonakis E. Medically important bacterial-fungal interactions. Nat Rev Microbiol. 2010;8(5):340–9.CrossRefPubMed Peleg AY, Hogan DA, Mylonakis E. Medically important bacterial-fungal interactions. Nat Rev Microbiol. 2010;8(5):340–9.CrossRefPubMed
36.
Zurück zum Zitat Wargo MJ, Hogan DA. Fungal--bacterial interactions: a mixed bag of mingling microbes. Curr Opin Microbiol. 2006;9(4):359–64.CrossRefPubMed Wargo MJ, Hogan DA. Fungal--bacterial interactions: a mixed bag of mingling microbes. Curr Opin Microbiol. 2006;9(4):359–64.CrossRefPubMed
37.
Zurück zum Zitat Wilson A, Gray D, Karakiozis J, Thomas J. Advanced endotracheal tube biofilm stage, not duration of intubation, is related to pneumonia. J Trauma Acute Care Surg. 2012;72(4):916–23.CrossRefPubMed Wilson A, Gray D, Karakiozis J, Thomas J. Advanced endotracheal tube biofilm stage, not duration of intubation, is related to pneumonia. J Trauma Acute Care Surg. 2012;72(4):916–23.CrossRefPubMed
38.
Zurück zum Zitat Bakke R, Kommedal R, Kalvenes S. Quantification of biofilm accumulation by an optical approach. J Microbiol Methods. 2001;44(1):13–26.CrossRefPubMed Bakke R, Kommedal R, Kalvenes S. Quantification of biofilm accumulation by an optical approach. J Microbiol Methods. 2001;44(1):13–26.CrossRefPubMed
39.
Zurück zum Zitat Elkhatib WF, Khairalla AS, Ashour HM. Evaluation of different microtiter plate-based methods for the quantitative assessment of Staphylococcus aureus biofilms. Future Microbiol. 2014;9(6):725–35.CrossRefPubMed Elkhatib WF, Khairalla AS, Ashour HM. Evaluation of different microtiter plate-based methods for the quantitative assessment of Staphylococcus aureus biofilms. Future Microbiol. 2014;9(6):725–35.CrossRefPubMed
Metadaten
Titel
Species-specific characteristics of the biofilm generated in silicone tube: an in vitro study
verfasst von
Dong Ju Kim
Joo-Hee Park
Minwook Chang
Publikationsdatum
01.12.2018
Verlag
BioMed Central
Erschienen in
BMC Ophthalmology / Ausgabe 1/2018
Elektronische ISSN: 1471-2415
DOI
https://doi.org/10.1186/s12886-018-0750-1

Weitere Artikel der Ausgabe 1/2018

BMC Ophthalmology 1/2018 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Open Access 22.02.2024 | Peeling | Originalien

Selektive Vitalfarbstoffe in der Makulachirurgie

Erhöhen sie die Wahrscheinlichkeit der intraoperativen ILM-Identifizierung auch bei einem erfahrenen Operateur?

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.