Abstract

Speckle tracking echocardiography (STE) has become a useful tool in cardiology but remains scarcely developed in pediatrics. We aimed to evaluate the feasibility of STE analyses in healthy children and compare reliability of STE for left and right ventricles (LV, RV) between the EchoPAC (GE Healthcare) and the QLAB (Philips Healthcare) software systems. Healthy children were screened for this prospective cross-sectional study. Analyses were performed upon five levels of variability: intra/inter-ultrasound system, intra/inter-sonographer and intra/inter-analyzer. The feasibility was measured, and the tracking quality informed. The study included 156 healthy children. Mean age was 7.6 ± 5 years [1 month–16.8 years]. Conventional echocardiography variables were similar in both ultrasound systems. For both software brands, the tracking quality was excellent in the LV longitudinal and circumferential displacements, but more limited in the RV free wall longitudinal strain. Inter-ultrasound system correlation was poor for global longitudinal and circumferential LV strain (ICC of 0.34 [IC95% 0.06–0.57]) and 0.12 [IC95% − 0.18 to − 0.40], respectively). We observed poor inter-sonographer reliability for both global LV longitudinal strain and global LV circumferential strain with the two software systems. Inter-analyzer variability was good especially for the global LV circumferential strain using Philips software (ICC of 0.78 [IC95% 0.52–0.91]). In pediatrics, the Philips/GE inter-vendor level of variability in STE analysis is mainly due to inter ultrasound systems and inter sonographers’ differences. These results need to be taken into account when using STE analysis in the follow-up of cardiac children. Clinicaltrials.gov: NCT02056925.
Literatur
2.
Zurück zum Zitat Mondillo S, Galderisi M, Mele D, Cameli M, Lomoriello VS, Zaca V, Ballo P, D’Andrea A, Muraru D, Losi M, Agricola E, D’Errico A, Buralli S, Sciomer S, Nistri S, Badano L, Echocardiography Study Group Of The Italian Society Of C (2011) Speckle-tracking echocardiography: a new technique for assessing myocardial function. J Ultrasound Med 30(1):71–83CrossRefPubMed Mondillo S, Galderisi M, Mele D, Cameli M, Lomoriello VS, Zaca V, Ballo P, D’Andrea A, Muraru D, Losi M, Agricola E, D’Errico A, Buralli S, Sciomer S, Nistri S, Badano L, Echocardiography Study Group Of The Italian Society Of C (2011) Speckle-tracking echocardiography: a new technique for assessing myocardial function. J Ultrasound Med 30(1):71–83CrossRefPubMed
4.
Zurück zum Zitat Kosmala W, Plaksej R, Strotmann JM, Weigel C, Herrmann S, Niemann M, Mende H, Stork S, Angermann CE, Wagner JA, Weidemann F (2008) Progression of left ventricular functional abnormalities in hypertensive patients with heart failure: an ultrasonic two-dimensional speckle tracking study. J Am Soc Echocardiogr 21(12):1309–1317. https://doi.org/10.1016/j.echo.2008.10.006 CrossRefPubMed Kosmala W, Plaksej R, Strotmann JM, Weigel C, Herrmann S, Niemann M, Mende H, Stork S, Angermann CE, Wagner JA, Weidemann F (2008) Progression of left ventricular functional abnormalities in hypertensive patients with heart failure: an ultrasonic two-dimensional speckle tracking study. J Am Soc Echocardiogr 21(12):1309–1317. https://​doi.​org/​10.​1016/​j.​echo.​2008.​10.​006 CrossRefPubMed
15.
Zurück zum Zitat Mingo-Santos S, Monivas-Palomero V, Garcia-Lunar I, Mitroi CD, Goirigolzarri-Artaza J, Rivero B, Oteo JF, Castedo E, Gonzalez-Mirelis J, Cavero MA, Gomez-Bueno M, Segovia J, Alonso-Pulpon L (2015) Usefulness of two-dimensional strain parameters to diagnose acute rejection after heart transplantation. J Am Soc Echocardiogr 28(10):1149–1156. https://doi.org/10.1016/j.echo.2015.06.005 CrossRefPubMed Mingo-Santos S, Monivas-Palomero V, Garcia-Lunar I, Mitroi CD, Goirigolzarri-Artaza J, Rivero B, Oteo JF, Castedo E, Gonzalez-Mirelis J, Cavero MA, Gomez-Bueno M, Segovia J, Alonso-Pulpon L (2015) Usefulness of two-dimensional strain parameters to diagnose acute rejection after heart transplantation. J Am Soc Echocardiogr 28(10):1149–1156. https://​doi.​org/​10.​1016/​j.​echo.​2015.​06.​005 CrossRefPubMed
21.
Zurück zum Zitat Eindhoven JA, Menting ME, van den Bosch AE, McGhie JS, Witsenburg M, Cuypers JA, Boersma E, Roos-Hesselink JW (2015) Quantitative assessment of systolic right ventricular function using myocardial deformation in patients with a systemic right ventricle. Eur Heart J Cardiovasc Imaging 16(4):380–388. https://doi.org/10.1093/ehjci/jeu194 CrossRefPubMed Eindhoven JA, Menting ME, van den Bosch AE, McGhie JS, Witsenburg M, Cuypers JA, Boersma E, Roos-Hesselink JW (2015) Quantitative assessment of systolic right ventricular function using myocardial deformation in patients with a systemic right ventricle. Eur Heart J Cardiovasc Imaging 16(4):380–388. https://​doi.​org/​10.​1093/​ehjci/​jeu194 CrossRefPubMed
22.
Zurück zum Zitat Kalogeropoulos AP, Deka A, Border W, Pernetz MA, Georgiopoulou VV, Kiani J, McConnell M, Lerakis S, Butler J, Martin RP, Book WM (2012) Right ventricular function with standard and speckle-tracking echocardiography and clinical events in adults with D-transposition of the great arteries post atrial switch. J Am Soc Echocardiogr 25(3):304–312. https://doi.org/10.1016/j.echo.2011.12.003 CrossRefPubMed Kalogeropoulos AP, Deka A, Border W, Pernetz MA, Georgiopoulou VV, Kiani J, McConnell M, Lerakis S, Butler J, Martin RP, Book WM (2012) Right ventricular function with standard and speckle-tracking echocardiography and clinical events in adults with D-transposition of the great arteries post atrial switch. J Am Soc Echocardiogr 25(3):304–312. https://​doi.​org/​10.​1016/​j.​echo.​2011.​12.​003 CrossRefPubMed
24.
Zurück zum Zitat Alghamdi MH, Mertens L, Lee W, Yoo SJ, Grosse-Wortmann L (2013) Longitudinal right ventricular function is a better predictor of right ventricular contribution to exercise performance than global or outflow tract ejection fraction in tetralogy of Fallot: a combined echocardiography and magnetic resonance study. Eur Heart J Cardiovasc Imaging 14(3):235–239. https://doi.org/10.1093/ehjci/jes137 CrossRefPubMed Alghamdi MH, Mertens L, Lee W, Yoo SJ, Grosse-Wortmann L (2013) Longitudinal right ventricular function is a better predictor of right ventricular contribution to exercise performance than global or outflow tract ejection fraction in tetralogy of Fallot: a combined echocardiography and magnetic resonance study. Eur Heart J Cardiovasc Imaging 14(3):235–239. https://​doi.​org/​10.​1093/​ehjci/​jes137 CrossRefPubMed
27.
Zurück zum Zitat Ladouceur M, Redheuil A, Soulat G, Delclaux C, Azizi M, Patel M, Chatellier G, Legendre A, Iserin L, Boudjemline Y, Bonnet D, Mousseaux E, Investigators S (2016) Longitudinal strain of systemic right ventricle correlates with exercise capacity in adult with transposition of the great arteries after atrial switch. International journal of cardiology 217:28–34. https://doi.org/10.1016/j.ijcard.2016.04.166 CrossRefPubMed Ladouceur M, Redheuil A, Soulat G, Delclaux C, Azizi M, Patel M, Chatellier G, Legendre A, Iserin L, Boudjemline Y, Bonnet D, Mousseaux E, Investigators S (2016) Longitudinal strain of systemic right ventricle correlates with exercise capacity in adult with transposition of the great arteries after atrial switch. International journal of cardiology 217:28–34. https://​doi.​org/​10.​1016/​j.​ijcard.​2016.​04.​166 CrossRefPubMed
32.
Zurück zum Zitat Shiino K, Yamada A, Ischenko M, Khandheria BK, Hudaverdi M, Speranza V, Harten M, Benjamin A, Hamilton-Craig CR, Platts DG, Burstow DJ, Scalia GM, Chan J (2017) Intervendor consistency and reproducibility of left ventricular 2D global and regional strain with two different high-end ultrasound systems. Eur Heart J Cardiovasc Imaging 18(6):707–716. https://doi.org/10.1093/ehjci/jew120 CrossRefPubMed Shiino K, Yamada A, Ischenko M, Khandheria BK, Hudaverdi M, Speranza V, Harten M, Benjamin A, Hamilton-Craig CR, Platts DG, Burstow DJ, Scalia GM, Chan J (2017) Intervendor consistency and reproducibility of left ventricular 2D global and regional strain with two different high-end ultrasound systems. Eur Heart J Cardiovasc Imaging 18(6):707–716. https://​doi.​org/​10.​1093/​ehjci/​jew120 CrossRefPubMed
33.
Zurück zum Zitat Voigt JU, Pedrizzetti G, Lysyansky P, Marwick TH, Houle H, Baumann R, Pedri S, Ito Y, Abe Y, Metz S, Song JH, Hamilton J, Sengupta PP, Kolias TJ, d’Hooge J, Aurigemma GP, Thomas JD, Badano LP (2015) Definitions for a common standard for 2D speckle tracking echocardiography: consensus document of the EACVI/ASE/Industry Task Force to standardize deformation imaging. J Am Soc Echocardiogr 28(2):183–193. https://doi.org/10.1016/j.echo.2014.11.003 CrossRefPubMed Voigt JU, Pedrizzetti G, Lysyansky P, Marwick TH, Houle H, Baumann R, Pedri S, Ito Y, Abe Y, Metz S, Song JH, Hamilton J, Sengupta PP, Kolias TJ, d’Hooge J, Aurigemma GP, Thomas JD, Badano LP (2015) Definitions for a common standard for 2D speckle tracking echocardiography: consensus document of the EACVI/ASE/Industry Task Force to standardize deformation imaging. J Am Soc Echocardiogr 28(2):183–193. https://​doi.​org/​10.​1016/​j.​echo.​2014.​11.​003 CrossRefPubMed
34.
Zurück zum Zitat Lopez L, Colan SD, Frommelt PC, Ensing GJ, Kendall K, Younoszai AK, Lai WW, Geva T (2010) Recommendations for quantification methods during the performance of a pediatric echocardiogram: a report from the Pediatric Measurements Writing Group of the American Society of Echocardiography Pediatric and Congenital Heart Disease Council. J Am Soc Echocardiogr 23(5):465–495. https://doi.org/10.1016/j.echo.2010.03.019 quiz 576 – 467.CrossRefPubMed Lopez L, Colan SD, Frommelt PC, Ensing GJ, Kendall K, Younoszai AK, Lai WW, Geva T (2010) Recommendations for quantification methods during the performance of a pediatric echocardiogram: a report from the Pediatric Measurements Writing Group of the American Society of Echocardiography Pediatric and Congenital Heart Disease Council. J Am Soc Echocardiogr 23(5):465–495. https://​doi.​org/​10.​1016/​j.​echo.​2010.​03.​019 quiz 576 – 467.CrossRefPubMed
35.
Zurück zum Zitat Colan SD, Borow KM, Neumann A (1984) Left ventricular end-systolic wall stress-velocity of fiber shortening relation: a load-independent index of myocardial contractility. J Am Coll Cardiol 4(4):715–724CrossRefPubMed Colan SD, Borow KM, Neumann A (1984) Left ventricular end-systolic wall stress-velocity of fiber shortening relation: a load-independent index of myocardial contractility. J Am Coll Cardiol 4(4):715–724CrossRefPubMed
36.
Zurück zum Zitat Shrout PE, Fleiss JL (1979) Intraclass correlations: uses in assessing rater reliability. Psychol Bull 86(2):420–428CrossRefPubMed Shrout PE, Fleiss JL (1979) Intraclass correlations: uses in assessing rater reliability. Psychol Bull 86(2):420–428CrossRefPubMed
Metadaten
Titel
Speckle tracking echocardiography in healthy children: comparison between the QLAB by Philips and the EchoPAC by General Electric
verfasst von
Pascal Amedro
Charlene Bredy
Sophie Guillaumont
Gregoire De La Villeon
Lucie Gamon
Kathleen Lavastre
Albano C. Meli
Sylvain Richard
Olivier Cazorla
Alain Lacampagne
Thibault Mura
Marie Vincenti
Publikationsdatum
08.01.2019
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 5/2019
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-018-01516-2

Weitere Artikel der Ausgabe 5/2019

The International Journal of Cardiovascular Imaging 5/2019 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.