Abstract

Purpose

To measure spleen stiffness by shear wave elastography (SWE) using acoustic radiation force impulse (ARFI) in patients with splenomegaly and to evaluate utility of elastography technique in identifying etiology of splenomegaly.

Methods

Sixty-one treatment-naïve patients with splenomegaly were enrolled. The control group consisted of 20 healthy subjects without history of any disease including diabetes and hypertension, alcohol consumption, or biochemical or ultrasonographic findings indicating hepatic and renal diseases. B-mode ultrasonography and elastographic examinations were performed by a radiologist blinded to the participants. Spleen stiffness was measured by SWE using ARFI. Shear wave velocity (SWV) values were given in m/s.

Results

Splenomegaly patients were assigned into three groups according to their etiologies as hepatoportal (n = 21), myeloproliferative (n = 23), and infectious (n = 17). Splenomegaly groups and control group were comparable regarding age and sex. Spleen size was higher in the splenomegaly groups than in the controls. Median SWV was significantly higher in the hepatoportal (3.85 m/s) and myeloproliferative (3.42 m/s) groups than in the infectious (2.66 m/s) and control (2.22 m/s) groups. The correlation between SWV and spleen size was not significant in any of the groups. The cut-off value was 3.42 (sensitivity 80.9%, specificity 56.5%) in distinguishing hepatoportal from myeloproliferative etiology; 3.02 (sensitivity 100%, specificity 100%) in distinguishing hepatoportal from infectious etiology; and 2.84 (sensitivity 91.3%, specificity 88.2%) in distinguishing myeloproliferative from infectious etiology.

Conclusion

Spleen stiffness measured by elastographic techniques in splenomegaly patients was higher than that in healthy subjects. SWV appeared to be beneficial in predicting the etiology of splenomegaly.
Literatur
1.
Zurück zum Zitat Curovic Rotbain E, Lund Hansen D, Schaffalitzky de Muckadell O et al (2017) Splenomegaly - Diagnostic validity, work-up, and underlying causes. PLoS One 12:e0186674 Curovic Rotbain E, Lund Hansen D, Schaffalitzky de Muckadell O et al (2017) Splenomegaly - Diagnostic validity, work-up, and underlying causes. PLoS One 12:e0186674
2.
Zurück zum Zitat McKenzie CV, Colonne CK, Yeo JH, Fraser ST (2018) Splenomegaly: Pathophysiological bases and therapeutic options. Int J Biochem Cell Biol 94:40–43 McKenzie CV, Colonne CK, Yeo JH, Fraser ST (2018) Splenomegaly: Pathophysiological bases and therapeutic options. Int J Biochem Cell Biol 94:40–43
3.
Zurück zum Zitat Benter T, Klühs L, Teichgräber U (2011) Sonography of the spleen. J Ultrasound Med 30:1281–1293 Benter T, Klühs L, Teichgräber U (2011) Sonography of the spleen. J Ultrasound Med 30:1281–1293
4.
Zurück zum Zitat Sigrist RMS, Liau J, Kaffas AE, Chammas MC, Willmann JK (2017) Ultrasound elastography: Review of techniques and clinical applications. Theranostics 7:1303–1329 Sigrist RMS, Liau J, Kaffas AE, Chammas MC, Willmann JK (2017) Ultrasound elastography: Review of techniques and clinical applications. Theranostics 7:1303–1329
5.
Zurück zum Zitat Batur A, Alagoz S, Durmaz F, Baran AI, Ekinci O (2019) Measurement of spleen stiffness by shear-wave elastography for prediction of splenomegaly etiology. Ultrasound Q 35:153–156 Batur A, Alagoz S, Durmaz F, Baran AI, Ekinci O (2019) Measurement of spleen stiffness by shear-wave elastography for prediction of splenomegaly etiology. Ultrasound Q 35:153–156
6.
Zurück zum Zitat Furuichi Y, Moriyasu F, Taira J et al (2013) Noninvasive diagnostic method for idiopathic portal hypertension based on measurements of liver and spleen stiffness by ARFI elastography. J Gastroenterol 48:1061–1068 Furuichi Y, Moriyasu F, Taira J et al (2013) Noninvasive diagnostic method for idiopathic portal hypertension based on measurements of liver and spleen stiffness by ARFI elastography. J Gastroenterol 48:1061–1068
7.
Zurück zum Zitat Sjoberg BP, Menias CO, Lubner MG, Mellnick VM, Pickhardt PJ (2018) Splenomegaly: A combined clinical and radiologic approach to the differential diagnosis. Gastroenterol Clin North Am 47:643–666 Sjoberg BP, Menias CO, Lubner MG, Mellnick VM, Pickhardt PJ (2018) Splenomegaly: A combined clinical and radiologic approach to the differential diagnosis. Gastroenterol Clin North Am 47:643–666
8.
Zurück zum Zitat Pozo A.L., Godfrey E.M., and Bowles K.M (2009) Splenomegaly: investigation, diagnosis and management. Blood Rev 23: pp. 105-111 Pozo A.L., Godfrey E.M., and Bowles K.M (2009) Splenomegaly: investigation, diagnosis and management. Blood Rev 23: pp. 105-111
9.
Zurück zum Zitat O’Reilly R.A (1998) Splenomegaly in 2,505 patients at a large university medical center from 1913 to 1995. 1963 to 1995: 449 patients. West J Med 169: pp. 88-97 O’Reilly R.A (1998) Splenomegaly in 2,505 patients at a large university medical center from 1913 to 1995. 1963 to 1995: 449 patients. West J Med 169: pp. 88-97
10.
Zurück zum Zitat Tunnessen WW. Splenomegaly. Roberts K, Tunnessen W (eds.) (1999) Signs and Symptoms in Pediatrics. 3rd edition. Philadelphia, PA: Lippincott Williams and Wilkins pp. 475-483. Tunnessen WW. Splenomegaly. Roberts K, Tunnessen W (eds.) (1999) Signs and Symptoms in Pediatrics. 3rd edition. Philadelphia, PA: Lippincott Williams and Wilkins pp. 475-483.
11.
Zurück zum Zitat Simona Ioanitescu, Hans-Peter Weskott (206) The Spleen Elena, Center of Internal Medicine, Fundeni Clinical Institute 6: pp. 163-183. Simona Ioanitescu, Hans-Peter Weskott (206) The Spleen Elena, Center of Internal Medicine, Fundeni Clinical Institute 6: pp. 163-183.
12.
Zurück zum Zitat Mazur R, Celmer M, Silicki J, Hołownia D, Pozowski P, Międzybrodzki K (2018) Clinical applications of spleen ultrasound elastography - a review. J Ultrason 18:37–41 Mazur R, Celmer M, Silicki J, Hołownia D, Pozowski P, Międzybrodzki K (2018) Clinical applications of spleen ultrasound elastography - a review. J Ultrason 18:37–41
13.
Zurück zum Zitat Giuffrè M, Macor D, Masutti F et al (2019) Evaluation of spleen stiffness in healthy volunteers using point shear wave elastography. Ann Hepatol 18:736–741 Giuffrè M, Macor D, Masutti F et al (2019) Evaluation of spleen stiffness in healthy volunteers using point shear wave elastography. Ann Hepatol 18:736–741
14.
Zurück zum Zitat Albayrak E, Server S (2009) The relationship of spleen stiffness value measured by shear wave elastography with age, gender, and spleen size in healthy volunteers. J Med Ultrason (2001) 46:195–199 Albayrak E, Server S (2009) The relationship of spleen stiffness value measured by shear wave elastography with age, gender, and spleen size in healthy volunteers. J Med Ultrason (2001) 46:195–199
15.
Zurück zum Zitat Pawluś A, Inglot MS, Szymańska K et al (2016) Shear wave elastography of the spleen: evaluation of spleen stiffness in healthy volunteers. Abdom Radiol (NY) 41:2169–2174 Pawluś A, Inglot MS, Szymańska K et al (2016) Shear wave elastography of the spleen: evaluation of spleen stiffness in healthy volunteers. Abdom Radiol (NY) 41:2169–2174
16.
Zurück zum Zitat Ferraioli G, Tinelli C, Lissandrin R et al (2014) Ultrasound point shear wave elastography assessment of liver and spleen stiffness: effect of training on repeatability of measurements. Eur Radiol 24:1283–1289 Ferraioli G, Tinelli C, Lissandrin R et al (2014) Ultrasound point shear wave elastography assessment of liver and spleen stiffness: effect of training on repeatability of measurements. Eur Radiol 24:1283–1289
17.
Zurück zum Zitat Karlas T, Lindner F, Tröltzsch M, Keim V (2014) Assessment of spleen stiffness using acoustic radiation force impulse imaging (ARFI): definition of examination standards and impact of breathing maneuvers. Ultraschall Med 35:38–43 Karlas T, Lindner F, Tröltzsch M, Keim V (2014) Assessment of spleen stiffness using acoustic radiation force impulse imaging (ARFI): definition of examination standards and impact of breathing maneuvers. Ultraschall Med 35:38–43
18.
Zurück zum Zitat Cho YS, Lim S, Kim Y, Sohn JH, Jeong JY (2019) Spleen stiffness measurement using 2-dimensional shear wave elastography: the predictors of measurability and the normal spleen stiffness value. J Ultrasound Med 38:423–431 Cho YS, Lim S, Kim Y, Sohn JH, Jeong JY (2019) Spleen stiffness measurement using 2-dimensional shear wave elastography: the predictors of measurability and the normal spleen stiffness value. J Ultrasound Med 38:423–431
19.
Zurück zum Zitat Attia D, Schoenemeier B, Rodt T et al (2015) Evaluation of liver and spleen stiffness with acoustic radiation force impulse quantification elastography for diagnosing clinically significant portal hypertension. Ultraschall Med 36:603–610 Attia D, Schoenemeier B, Rodt T et al (2015) Evaluation of liver and spleen stiffness with acoustic radiation force impulse quantification elastography for diagnosing clinically significant portal hypertension. Ultraschall Med 36:603–610
20.
Zurück zum Zitat Song J, Huang J, Huang H, Liu S, Luo Y (2018) Performance of spleen stiffness measurement in prediction of clinical significant portal hypertension: A meta-analysis. Clin Res Hepatol Gastroenterol 42:216–226 Song J, Huang J, Huang H, Liu S, Luo Y (2018) Performance of spleen stiffness measurement in prediction of clinical significant portal hypertension: A meta-analysis. Clin Res Hepatol Gastroenterol 42:216–226
21.
Zurück zum Zitat Goldschmidt I, Brauch C, Poynard T, Baumann U (2014) Spleen stiffness measurement by transient elastography to diagnose portal hypertension in children. J Pediatr Gastroenterol Nutr 59:197–203 Goldschmidt I, Brauch C, Poynard T, Baumann U (2014) Spleen stiffness measurement by transient elastography to diagnose portal hypertension in children. J Pediatr Gastroenterol Nutr 59:197–203
22.
Zurück zum Zitat Takuma Y, Nouso K, Morimoto Y et al (2016) Portal hypertension in patients with liver cirrhosis: diagnostic accuracy of spleen stiffness. Radiology 279:609–619 Takuma Y, Nouso K, Morimoto Y et al (2016) Portal hypertension in patients with liver cirrhosis: diagnostic accuracy of spleen stiffness. Radiology 279:609–619
23.
Zurück zum Zitat Stefanescu H, Grigorescu M, Lupsor M, Procopet B, Maniu A, Badea R (2011) Spleen stiffness measurement using Fibroscan for the noninvasive assessment of esophageal varices in liver cirrhosis patients. J Gastroenterol Hepatol 26:164–170 Stefanescu H, Grigorescu M, Lupsor M, Procopet B, Maniu A, Badea R (2011) Spleen stiffness measurement using Fibroscan for the noninvasive assessment of esophageal varices in liver cirrhosis patients. J Gastroenterol Hepatol 26:164–170
24.
Zurück zum Zitat Sharma P, Kirnake V, Tyagi P et al (2013) Spleen stiffness in patients with cirrhosis in predicting esophageal varices. Am J Gastroenterol 108:1101–1107 Sharma P, Kirnake V, Tyagi P et al (2013) Spleen stiffness in patients with cirrhosis in predicting esophageal varices. Am J Gastroenterol 108:1101–1107
25.
Zurück zum Zitat Karagiannakis DS, Voulgaris T, Koureta E, Chloupi E, Papatheodoridis GV, Vlachogiannakos J et al (2019) Role of spleen stiffness measurement by 2D-shear wave elastography in ruling out the presence of high-risk varices in cirrhotic patients. Dig Dis Sci 64:2653–2660 Karagiannakis DS, Voulgaris T, Koureta E, Chloupi E, Papatheodoridis GV, Vlachogiannakos J et al (2019) Role of spleen stiffness measurement by 2D-shear wave elastography in ruling out the presence of high-risk varices in cirrhotic patients. Dig Dis Sci 64:2653–2660
26.
Zurück zum Zitat Fierbinteanu-Braticevici C, Tribus L, Peagu R et al (2019) Spleen stiffness as predictor of esophageal varices in cirrhosis of different etiologies. Sci Rep 9:16190 Fierbinteanu-Braticevici C, Tribus L, Peagu R et al (2019) Spleen stiffness as predictor of esophageal varices in cirrhosis of different etiologies. Sci Rep 9:16190
27.
Zurück zum Zitat Ma X, Wang L, Wu H et al (2016) Spleen stiffness is superior to liver stiffness for predicting esophageal varices in chronic liver disease: a meta-analysis. PLoS One 11:e0165786 Ma X, Wang L, Wu H et al (2016) Spleen stiffness is superior to liver stiffness for predicting esophageal varices in chronic liver disease: a meta-analysis. PLoS One 11:e0165786
28.
Zurück zum Zitat Chen SH, Li YF, Lai HC et al (2012) Noninvasive assessment of liver fibrosis via spleen stiffness measurement using acoustic radiation force impulse sonoelastography in patients with chronic hepatitis B or C. J Viral Hepat 19:654–663 Chen SH, Li YF, Lai HC et al (2012) Noninvasive assessment of liver fibrosis via spleen stiffness measurement using acoustic radiation force impulse sonoelastography in patients with chronic hepatitis B or C. J Viral Hepat 19:654–663
29.
Zurück zum Zitat Peagu R, Sararu R, Necula A, Moldoveanu A, Petrisor A, Fierbinteanu-Braticevici C (2019) The role of spleen stiffness using ARFI in predicting esophageal varices in patients with Hepatitis B and C virus-related cirrhosis. Rom J Intern Med 57:334–340 Peagu R, Sararu R, Necula A, Moldoveanu A, Petrisor A, Fierbinteanu-Braticevici C (2019) The role of spleen stiffness using ARFI in predicting esophageal varices in patients with Hepatitis B and C virus-related cirrhosis. Rom J Intern Med 57:334–340
30.
Zurück zum Zitat Takuma Y, Morimoto Y, Takabatake H et al (2017) Measurement of spleen stiffness with acoustic radiation force impulse imaging predicts mortality and hepatic decompensation in patients with liver cirrhosis. Clin Gastroenterol Hepatol 15:1782–1790.e4 Takuma Y, Morimoto Y, Takabatake H et al (2017) Measurement of spleen stiffness with acoustic radiation force impulse imaging predicts mortality and hepatic decompensation in patients with liver cirrhosis. Clin Gastroenterol Hepatol 15:1782–1790.e4
31.
Zurück zum Zitat Webb M, Shibolet O, Halpern Z et al (2015) Assessment of liver and spleen stiffness in patients with myelofibrosis using fibroscan and shear wave elastography. Ultrasound Q 31:166–169 Webb M, Shibolet O, Halpern Z et al (2015) Assessment of liver and spleen stiffness in patients with myelofibrosis using fibroscan and shear wave elastography. Ultrasound Q 31:166–169
Metadaten
Titel
Spleen stiffness measurement by shear wave elastography using acoustic radiation force impulse in predicting the etiology of splenomegaly
verfasst von
Kadihan Yalçın
Bilge Çakar Demir
Publikationsdatum
08.08.2020
Verlag
Springer US
Erschienen in
Abdominal Radiology / Ausgabe 2/2021
Print ISSN: 2366-004X
Elektronische ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-020-02649-6

Weitere Artikel der Ausgabe 2/2021

Abdominal Radiology 2/2021 Zur Ausgabe

SAR DFP Report

GI Bleed DFP report

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.