Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 6/2018

28.11.2017 | Knee

Stability and alignment do not improve by using patient-specific instrumentation in total knee arthroplasty: a randomized controlled trial

verfasst von: Nienke M. Kosse, Petra J. C. Heesterbeek, Janneke J. P. Schimmel, Gijs G. van Hellemondt, Ate B. Wymenga, Koen C. Defoort

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 6/2018

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The primary aim of the study was to examine stability and alignment after total knee arthroplasty (TKA) using patient-specific instrumentation (PSI) and conventional instrumentation (CI). The hypothesis was that stability and alignment would be better using PSI than CI, 12 months postoperatively. The secondary aim included the evaluation of clinical outcomes after TKA.

Methods

In this prospective randomized controlled trial, 42 patients with knee osteoarthritis received a Genesis II PS prosthesis with either PSI or CI. Patients visited the hospital preoperatively and postoperatively after 6 weeks and 3 and 12 months. To evaluate stability, varus–valgus laxity was determined in extension and flexion using stress radiographs 12 months postoperatively. Three months postoperatively, a long-leg radiograph and CT scan were obtained to measure hip–knee–ankle (HKA) alignment and component rotation. Furthermore, frontal and sagittal alignment of the components, the Knee Society Score, VAS Pain, VAS Satisfaction, Knee injury and Osteoarthritis Outcome score, Patella score (Kujala), University of California Los Angeles activity score, anterior–posterior laxity, (serious) adverse device-related events, and intraoperative complications were reported. The clinical outcomes were compared using independent t tests or non-parametric alternatives, and repeated measurements ANOVA with a significance level of p < 0.05.

Results

No significant differences were found between the two groups regarding stability, HKA angle, and rotational alignment. In four patients, the PSI did not fit correctly on the tibia and/or femur requiring intraoperative modifications. Both groups improved significantly over time on all clinical outcomes, with no significant differences between the groups 12 months postoperatively. The PSI group showed less tibial slope than the patients in the CI group [PSI 2.6° versus CI 4.8° (p = 0.02)]. Finally, the PSI group more frequently received a thinner insert size than the CI group (p = 0.03).

Conclusions

Patients operated with PSI did not differ from CI in terms of stability and alignment. However, in the PSI group ligament releases were more often required intraoperatively. Furthermore, the two methods did not show different clinical results. It seems that the preoperative planning for the PSI facilitates more conservative bone cuts than CI, but whether this is clinically relevant should be investigated. Since PSI is more expensive and time consuming than CI, and does not outperform CI with regard to clinical results, we recommend to use CI.

Level of evidence

I.
Literatur
1.
Zurück zum Zitat An VVG, Sivakumar BS, Phan K, Levy YD, Bruce WJM (2017) Accuracy of MRI-based vs. CT-based patient-specific instrumentation in total knee arthroplasty: a meta-analysis. J Orthop Sci 22:116–120CrossRefPubMed An VVG, Sivakumar BS, Phan K, Levy YD, Bruce WJM (2017) Accuracy of MRI-based vs. CT-based patient-specific instrumentation in total knee arthroplasty: a meta-analysis. J Orthop Sci 22:116–120CrossRefPubMed
2.
Zurück zum Zitat Anderl W, Pauzenberger L, Kölblinger R, Kiesselbach G, Brandl G, Laky B, Kriegleder B, Heuberer P, Schwameis E (2014) Patient-specific instrumentation improved mechanical alignment, while early clinical outcome was comparable to conventional instrumentation in TKA. Knee Surg Sports Traumatol Arthrosc 24:102–111CrossRefPubMed Anderl W, Pauzenberger L, Kölblinger R, Kiesselbach G, Brandl G, Laky B, Kriegleder B, Heuberer P, Schwameis E (2014) Patient-specific instrumentation improved mechanical alignment, while early clinical outcome was comparable to conventional instrumentation in TKA. Knee Surg Sports Traumatol Arthrosc 24:102–111CrossRefPubMed
3.
Zurück zum Zitat Berger RA, Crossett LS, Jacobs JJ, Rubash HE (1998) Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res 356:144–153CrossRef Berger RA, Crossett LS, Jacobs JJ, Rubash HE (1998) Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res 356:144–153CrossRef
4.
Zurück zum Zitat Berger RA, Rubash HE, Seel MJ, Thompson WH, Crossett LS (1993) Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res 286:40–47 Berger RA, Rubash HE, Seel MJ, Thompson WH, Crossett LS (1993) Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res 286:40–47
5.
Zurück zum Zitat Choong PF, Dowsey MM, Stoney JD (2009) Does accurate anatomical alignment result in better function and quality of life? Comparing conventional and computer-assisted total knee arthroplasty. J Arthroplasty 24:560–569CrossRefPubMed Choong PF, Dowsey MM, Stoney JD (2009) Does accurate anatomical alignment result in better function and quality of life? Comparing conventional and computer-assisted total knee arthroplasty. J Arthroplasty 24:560–569CrossRefPubMed
6.
Zurück zum Zitat Goyal T, Tripathy SK (2016) Does patient-specific instrumentations improve short-term functional outcomes after total knee arthroplasty? A systematic review and meta-analysis. J Arthroplasty 31:2173–2180CrossRefPubMed Goyal T, Tripathy SK (2016) Does patient-specific instrumentations improve short-term functional outcomes after total knee arthroplasty? A systematic review and meta-analysis. J Arthroplasty 31:2173–2180CrossRefPubMed
7.
Zurück zum Zitat Gromov K, Korchi M, Thomsen MG, Husted H, Troelsen A (2014) What is the optimal alignment of the tibial and femoral components in knee arthroplasty? Acta Orthop 85:480–487CrossRefPubMedPubMedCentral Gromov K, Korchi M, Thomsen MG, Husted H, Troelsen A (2014) What is the optimal alignment of the tibial and femoral components in knee arthroplasty? Acta Orthop 85:480–487CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Heesterbeek PJC, Keijsers NLW, Wymenga AB (2010) Ligament releases do not lead to increased postoperative varus–valgus laxity in flexion and extension: a prospective clinical study in 49 TKR patients. Knee Surg Sports Traumatol Arthrosc 18:187–193CrossRefPubMed Heesterbeek PJC, Keijsers NLW, Wymenga AB (2010) Ligament releases do not lead to increased postoperative varus–valgus laxity in flexion and extension: a prospective clinical study in 49 TKR patients. Knee Surg Sports Traumatol Arthrosc 18:187–193CrossRefPubMed
9.
Zurück zum Zitat Heesterbeek PJC, Verdonschot N, Wymenga AB (2008) In vivo knee laxity in flexion and extension: a radiographic study in 30 older healthy subjects. Knee 15:45–49CrossRefPubMed Heesterbeek PJC, Verdonschot N, Wymenga AB (2008) In vivo knee laxity in flexion and extension: a radiographic study in 30 older healthy subjects. Knee 15:45–49CrossRefPubMed
10.
Zurück zum Zitat Hossain F, Patel S, Haddad FS (2010) Midterm assessment of causes and results of revision total knee arthroplasty. Clin Orthop Relat Res 468:1221–1228CrossRefPubMedPubMedCentral Hossain F, Patel S, Haddad FS (2010) Midterm assessment of causes and results of revision total knee arthroplasty. Clin Orthop Relat Res 468:1221–1228CrossRefPubMedPubMedCentral
11.
Zurück zum Zitat Huijbregts HJTAM, Khan RJK, Fick DP, Hall MJ, Punwar SA, Sorensen E, Reid MJ, Dalle Vedove S, Haebich S (2016) Component alignment and clinical outcome following total knee arthroplasty; a randomised controlled trial comparing an intramedullary alignment system with patient-specific instrumentation. Bone Jt J 98:1043–1049CrossRef Huijbregts HJTAM, Khan RJK, Fick DP, Hall MJ, Punwar SA, Sorensen E, Reid MJ, Dalle Vedove S, Haebich S (2016) Component alignment and clinical outcome following total knee arthroplasty; a randomised controlled trial comparing an intramedullary alignment system with patient-specific instrumentation. Bone Jt J 98:1043–1049CrossRef
12.
Zurück zum Zitat Insall JN, Binazzi R, Soudry M, Mestriner LA (1985) Total knee arthroplasty. Clin Orthop Relat Res 192:13–22 Insall JN, Binazzi R, Soudry M, Mestriner LA (1985) Total knee arthroplasty. Clin Orthop Relat Res 192:13–22
13.
Zurück zum Zitat Le DH, Goodman SB, Maloney WJ, Huddleston JI (2014) Current modes of failure in TKA: infection, instability, and stiffness predominate. Clin Orthop Relat Res 472:2197–2200CrossRefPubMedPubMedCentral Le DH, Goodman SB, Maloney WJ, Huddleston JI (2014) Current modes of failure in TKA: infection, instability, and stiffness predominate. Clin Orthop Relat Res 472:2197–2200CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat Levy YD, An VVG, Shean CJW, Groen FR, Walker PM, Bruce WJM, Walker PM (2016) The accuracy of bony resection from patient-specific guides during total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 25:1678–1685CrossRefPubMed Levy YD, An VVG, Shean CJW, Groen FR, Walker PM, Bruce WJM, Walker PM (2016) The accuracy of bony resection from patient-specific guides during total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 25:1678–1685CrossRefPubMed
15.
Zurück zum Zitat Luyckx T, Peeters T, Vandenneucker H, Victor J, Bellemans J (2012) Is adapted measured resection superior to gap-balancing in determining femoral component rotation in total knee replacement? J Bone Jt Surg Br 94:1271–1276CrossRef Luyckx T, Peeters T, Vandenneucker H, Victor J, Bellemans J (2012) Is adapted measured resection superior to gap-balancing in determining femoral component rotation in total knee replacement? J Bone Jt Surg Br 94:1271–1276CrossRef
16.
Zurück zum Zitat Mannan A, Akinyooye D, Tr F, Hossain F (2016) A meta-analysis of functional outcomes in patient-specific instrumented knee arthroplasty. J Knee Surg 1:2–8 Mannan A, Akinyooye D, Tr F, Hossain F (2016) A meta-analysis of functional outcomes in patient-specific instrumented knee arthroplasty. J Knee Surg 1:2–8
17.
Zurück zum Zitat Mannan A, Smith TO, Sagar C, London NJ, Molitor PJA (2015) No demonstrable benefit for coronal alignment outcomes in PSI knee arthroplasty: a systematic review and meta-analysis. Orthop Traumatol Surg Res 101:461–468CrossRefPubMed Mannan A, Smith TO, Sagar C, London NJ, Molitor PJA (2015) No demonstrable benefit for coronal alignment outcomes in PSI knee arthroplasty: a systematic review and meta-analysis. Orthop Traumatol Surg Res 101:461–468CrossRefPubMed
18.
Zurück zum Zitat Ritter MA, Davis KE, Meding JB, Pierson JL, Berend ME, Malinzak RA (2011) The effect of alignment and BMI on failure of total knee replacement. J Bone Jt Surg Am 93:1588–1596CrossRef Ritter MA, Davis KE, Meding JB, Pierson JL, Berend ME, Malinzak RA (2011) The effect of alignment and BMI on failure of total knee replacement. J Bone Jt Surg Am 93:1588–1596CrossRef
19.
Zurück zum Zitat Ritter MA, Faris PM, Keating M, Meding JB (1994) Postoperative alignment of total knee replacement: its effect on survival. Clin Orthop Relat Res 299:153–156 Ritter MA, Faris PM, Keating M, Meding JB (1994) Postoperative alignment of total knee replacement: its effect on survival. Clin Orthop Relat Res 299:153–156
20.
Zurück zum Zitat Schimmel JJP, Defoort KC, Heesterbeek PJC, Wymenga AB, Jacobs WCH, van Hellemondt GG (2014) Bicruciate substituting design does not improve maximal flexion in total knee arthroplasty a randomized controlled trial. J Bone Jt Surg Am 96:1–8CrossRef Schimmel JJP, Defoort KC, Heesterbeek PJC, Wymenga AB, Jacobs WCH, van Hellemondt GG (2014) Bicruciate substituting design does not improve maximal flexion in total knee arthroplasty a randomized controlled trial. J Bone Jt Surg Am 96:1–8CrossRef
21.
Zurück zum Zitat Victor J, Dujardin J, Vandenneucker H, Arnout N, Bellemans J (2014) Patient-specific guides do not improve accuracy in total knee arthroplasty: a prospective randomized controlled trial. Clin Orthop Relat Res 472:263–271CrossRefPubMed Victor J, Dujardin J, Vandenneucker H, Arnout N, Bellemans J (2014) Patient-specific guides do not improve accuracy in total knee arthroplasty: a prospective randomized controlled trial. Clin Orthop Relat Res 472:263–271CrossRefPubMed
22.
Zurück zum Zitat Victor J, Ghijselings S, Tajdar F, Van Damme G, Deprez P, Arnout N, Van Der Straeten C (2014) Total knee arthroplasty at 15–17 years: does implant design affect outcome? Int Orthop 38:235–241CrossRefPubMed Victor J, Ghijselings S, Tajdar F, Van Damme G, Deprez P, Arnout N, Van Der Straeten C (2014) Total knee arthroplasty at 15–17 years: does implant design affect outcome? Int Orthop 38:235–241CrossRefPubMed
23.
Zurück zum Zitat Vide J, Pinto T, Acácio F, Henrique R (2017) Patient-specific instrumentation in total knee arthroplasty: simpler, faster and more accurate than standard instrumentation—a randomized controlled trial. Knee Surg Sports Traumatol Arthrosc 25:2616–2621CrossRefPubMed Vide J, Pinto T, Acácio F, Henrique R (2017) Patient-specific instrumentation in total knee arthroplasty: simpler, faster and more accurate than standard instrumentation—a randomized controlled trial. Knee Surg Sports Traumatol Arthrosc 25:2616–2621CrossRefPubMed
24.
Zurück zum Zitat Vundelinckx BJ, Bruckers L, De Mulder K, De Schepper J, Van Esbroeck G (2013) Functional and radiographic short-term outcome evaluation of the Visionaire system, a patient-matched instrumentation system for total knee arthroplasty. J Arthroplasty 28:964–970CrossRefPubMed Vundelinckx BJ, Bruckers L, De Mulder K, De Schepper J, Van Esbroeck G (2013) Functional and radiographic short-term outcome evaluation of the Visionaire system, a patient-matched instrumentation system for total knee arthroplasty. J Arthroplasty 28:964–970CrossRefPubMed
26.
Zurück zum Zitat Zalzal P, Papini M, Petruccelli D, de Beer J, Winemaker MJ (2004) An in vivo biomechanical analysis of the soft-tissue envelope of osteoarthritic knees. J Arthroplasty 19:217–223CrossRefPubMed Zalzal P, Papini M, Petruccelli D, de Beer J, Winemaker MJ (2004) An in vivo biomechanical analysis of the soft-tissue envelope of osteoarthritic knees. J Arthroplasty 19:217–223CrossRefPubMed
Metadaten
Titel
Stability and alignment do not improve by using patient-specific instrumentation in total knee arthroplasty: a randomized controlled trial
verfasst von
Nienke M. Kosse
Petra J. C. Heesterbeek
Janneke J. P. Schimmel
Gijs G. van Hellemondt
Ate B. Wymenga
Koen C. Defoort
Publikationsdatum
28.11.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 6/2018
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-017-4792-3

Weitere Artikel der Ausgabe 6/2018

Knee Surgery, Sports Traumatology, Arthroscopy 6/2018 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.