Abstract

The purpose of our study was to compare the diagnostic performance of subtraction computed tomography angiography (CTA) with conventional nonsubtracted CTA and digital subtraction angiography (DSA) for the detection of intracranial aneurysms. A total of 76 patients underwent both subtraction CTA and conventional CTA for the detection and therapy planning of suspected intracranial aneurysms. Subtraction and conventional CTA images were independently assessed by two readers in a blinded manner. The possibility of endovascular treatment or surgical clipping was also assessed based on information provided by CT angiograms alone. In 64 patients, 75 aneurysms were present on DSA. On a per-aneurysm basis, the sensitivity of subtraction CTA was 98.6% for reader 1, and 100% for reader 2. However, sensitivity of conventional CTA was 94.6% for reader 1, and 93.3% for reader 2. Therapeutic decisions could be made regarding 63 patients based on information provided by subtraction CTA images. However, conventional CTA provided sufficient information to make this decision for 55 patients. Conventional CTA has limited sensitivity in detecting very small aneurysms as well as aneurysms adjacent to bone. Subtraction CTA performed on a 64-row multidetector CT is an accurate and promising diagnostic tool that seems to be equivalent to 2D DSA for the detection and pretreatment planning of intracranial aneurysms.
Literatur
1.
Zurück zum Zitat White PM, Wardlaw JM, Easton V (2000) Can noninvasive imaging accurately depict intracranial aneurysms? A systematic review. Radiology 217:361–370PubMed White PM, Wardlaw JM, Easton V (2000) Can noninvasive imaging accurately depict intracranial aneurysms? A systematic review. Radiology 217:361–370PubMed
2.
Zurück zum Zitat U-King-Im JM, Koo B, Trivedi RA et al (2005) Current diagnostic approaches to subarachnoid haemorrhage. Eur Radiol 15:1135–1147PubMedCrossRef U-King-Im JM, Koo B, Trivedi RA et al (2005) Current diagnostic approaches to subarachnoid haemorrhage. Eur Radiol 15:1135–1147PubMedCrossRef
3.
Zurück zum Zitat Cloft HJ, Joseph GJ, Dion JE (1999) Risk of cerebral angiography in patients with subarachnoid hemorrhage, cerebral aneurysm, and arteriovenous malformation: a meta-analysis. Stroke 30:317–320PubMed Cloft HJ, Joseph GJ, Dion JE (1999) Risk of cerebral angiography in patients with subarachnoid hemorrhage, cerebral aneurysm, and arteriovenous malformation: a meta-analysis. Stroke 30:317–320PubMed
4.
Zurück zum Zitat Papke K, Brassel F (2006) Modern cross-sectional imaging in the diagnosis and follow-up of intracranial aneurysms. Eur Radiol 16:2051–2066PubMedCrossRef Papke K, Brassel F (2006) Modern cross-sectional imaging in the diagnosis and follow-up of intracranial aneurysms. Eur Radiol 16:2051–2066PubMedCrossRef
5.
Zurück zum Zitat Teksam M, McKinney A, Casey S et al (2004) Multi-section CT angiography for detection of cerebral aneurysms. AJNR Am J Neuroradiol 25:1485–492PubMed Teksam M, McKinney A, Casey S et al (2004) Multi-section CT angiography for detection of cerebral aneurysms. AJNR Am J Neuroradiol 25:1485–492PubMed
6.
Zurück zum Zitat Tipper G, U-King-Im JM, Price SJ et al (2005) Detection and evaluation of intracranial aneurysms with 16-row multislice CT angiography. Clin Radiol 60:565–572PubMedCrossRef Tipper G, U-King-Im JM, Price SJ et al (2005) Detection and evaluation of intracranial aneurysms with 16-row multislice CT angiography. Clin Radiol 60:565–572PubMedCrossRef
7.
Zurück zum Zitat Chappell ET, Moure FC, Good MC (2003) Comparison of computed tomographic angiography with digital subtraction angiography in the diagnosis of cerebral aneurysms: a meta-analysis. Neurosurgery 52:624–631PubMedCrossRef Chappell ET, Moure FC, Good MC (2003) Comparison of computed tomographic angiography with digital subtraction angiography in the diagnosis of cerebral aneurysms: a meta-analysis. Neurosurgery 52:624–631PubMedCrossRef
8.
Zurück zum Zitat Lell M, Anders K, Klotz E et al (2006) Clinical evaluation of bone-subtraction CT angiography (BSCTA) in head and neck imaging. Eur Radiol 16:889–897PubMedCrossRef Lell M, Anders K, Klotz E et al (2006) Clinical evaluation of bone-subtraction CT angiography (BSCTA) in head and neck imaging. Eur Radiol 16:889–897PubMedCrossRef
9.
Zurück zum Zitat Sakamoto S, Kiura Y, Shibukawa M et al (2006) Subtracted 3D CT angiography for evaluation of internal carotid artery aneurysms: comparison with conventional digital subtraction angiography. AJNR Am J Neuroradiol 27:1332–1337PubMed Sakamoto S, Kiura Y, Shibukawa M et al (2006) Subtracted 3D CT angiography for evaluation of internal carotid artery aneurysms: comparison with conventional digital subtraction angiography. AJNR Am J Neuroradiol 27:1332–1337PubMed
10.
Zurück zum Zitat Pozzi-Mucelli F, Bruni S, Doddi M et al (2007) Detection of intracranial aneurysms with 64 channel multidetector row computed tomography: comparison with digital subtraction angiography. Eur J Radiol 64:15–26PubMedCrossRef Pozzi-Mucelli F, Bruni S, Doddi M et al (2007) Detection of intracranial aneurysms with 64 channel multidetector row computed tomography: comparison with digital subtraction angiography. Eur J Radiol 64:15–26PubMedCrossRef
11.
Zurück zum Zitat Korogi Y, Takahashi M, Katada K et al (1999) Intracranial aneurysms: detection with three-dimensional CT angiography with volume rendering—comparison with conventional angiographic and surgical findings. Radiology 211:497–506PubMed Korogi Y, Takahashi M, Katada K et al (1999) Intracranial aneurysms: detection with three-dimensional CT angiography with volume rendering—comparison with conventional angiographic and surgical findings. Radiology 211:497–506PubMed
12.
Zurück zum Zitat Young N, Dorsch NW, Kingston RJ, Markson G, McMahon J (2001) Intracranial aneurysms: evaluation in 200 patients with spiral CT angiography. Eur Radiol 11:123–130PubMedCrossRef Young N, Dorsch NW, Kingston RJ, Markson G, McMahon J (2001) Intracranial aneurysms: evaluation in 200 patients with spiral CT angiography. Eur Radiol 11:123–130PubMedCrossRef
13.
Zurück zum Zitat Anderson GB, Steinke DE, Petruk KC et al (1999) Computed tomographic angiography versus digital subtraction angiography for the diagnosis and early treatment of ruptured intracranial aneurysms. Neurosurgery 45:1315–1320PubMedCrossRef Anderson GB, Steinke DE, Petruk KC et al (1999) Computed tomographic angiography versus digital subtraction angiography for the diagnosis and early treatment of ruptured intracranial aneurysms. Neurosurgery 45:1315–1320PubMedCrossRef
14.
Zurück zum Zitat Velthuis BK, Van Leeuwen MS, Witkamp TD et al (1999) Computerized tomography angiography in patients with subarachnoid hemorrhage: from aneurysm detection to treatment without conventional angiography. J Neurosurg 91:761–767PubMedCrossRef Velthuis BK, Van Leeuwen MS, Witkamp TD et al (1999) Computerized tomography angiography in patients with subarachnoid hemorrhage: from aneurysm detection to treatment without conventional angiography. J Neurosurg 91:761–767PubMedCrossRef
15.
Zurück zum Zitat Wintermark M, Uske A, Chalaron M et al (2003) Multislice computerized tomography angiography in the evaluation of intracranial aneurysms: a comparison with intraarterial digital subtraction angiography. J Neurosurg 98:828–836PubMedCrossRef Wintermark M, Uske A, Chalaron M et al (2003) Multislice computerized tomography angiography in the evaluation of intracranial aneurysms: a comparison with intraarterial digital subtraction angiography. J Neurosurg 98:828–836PubMedCrossRef
16.
Zurück zum Zitat Chen W, Yang Y, Xing W et al (2008) Sixteen-row multislice computed tomography angiography in the diagnosis and characterization of intracranial aneurysms: comparison with conventional angiography and intraoperative findings. J Neurosurg 108:1184–1191PubMedCrossRef Chen W, Yang Y, Xing W et al (2008) Sixteen-row multislice computed tomography angiography in the diagnosis and characterization of intracranial aneurysms: comparison with conventional angiography and intraoperative findings. J Neurosurg 108:1184–1191PubMedCrossRef
17.
Zurück zum Zitat Agid R, Lee SK, Willinsky RA et al (2006) Acute subarachnoid hemorrhage: using 64-slice multidetector CT angiography to “triage” patients’ treatment. Neuroradiology 48:787–794PubMedCrossRef Agid R, Lee SK, Willinsky RA et al (2006) Acute subarachnoid hemorrhage: using 64-slice multidetector CT angiography to “triage” patients’ treatment. Neuroradiology 48:787–794PubMedCrossRef
18.
Zurück zum Zitat McKinney AM, Palmer CS, Truwit CL, Karagulle A, Teksam M (2008) Detection of aneurysms by 64-Section multidetector CT angiography in patients acutely suspected of having an intracranial aneurysm and comparison with digital subtraction and 3D rotational angiography. AJNR Am J Neuroradiol 29:594–602PubMedCrossRef McKinney AM, Palmer CS, Truwit CL, Karagulle A, Teksam M (2008) Detection of aneurysms by 64-Section multidetector CT angiography in patients acutely suspected of having an intracranial aneurysm and comparison with digital subtraction and 3D rotational angiography. AJNR Am J Neuroradiol 29:594–602PubMedCrossRef
19.
Zurück zum Zitat Gorzer H, Heimberger K, Schindler E (1994) Spiral CT angiography with digital subtraction of extra- and intracranial vessels. J Comput Assist Tomogr 18:839–841PubMedCrossRef Gorzer H, Heimberger K, Schindler E (1994) Spiral CT angiography with digital subtraction of extra- and intracranial vessels. J Comput Assist Tomogr 18:839–841PubMedCrossRef
20.
Zurück zum Zitat Jayakrishnan VK, White PM, Aitken D, Crane P, McMahon AD, Teasdale EM (2003) Subtraction helical CT angiography of intra- and extracranial vessels: technical considerations and preliminary experience. AJNR Am J Neuroradiol 24:451–455PubMed Jayakrishnan VK, White PM, Aitken D, Crane P, McMahon AD, Teasdale EM (2003) Subtraction helical CT angiography of intra- and extracranial vessels: technical considerations and preliminary experience. AJNR Am J Neuroradiol 24:451–455PubMed
21.
Zurück zum Zitat Venema HW, Hulsmans FJ, den Heeten GJ (2001) CT angiography of the circle of Willis and intracranial internal carotid arteries: maximum intensity projection with matched mask bone elimination-feasibility study. Radiology 218:893–898PubMed Venema HW, Hulsmans FJ, den Heeten GJ (2001) CT angiography of the circle of Willis and intracranial internal carotid arteries: maximum intensity projection with matched mask bone elimination-feasibility study. Radiology 218:893–898PubMed
22.
Zurück zum Zitat Tomandl BF, Hammen T, Klotz E et al (2006) Bone-subtraction CT angiography for the evaluation of intracranial aneurysms. AJNR Am J Neuroradiol 27:55–59PubMed Tomandl BF, Hammen T, Klotz E et al (2006) Bone-subtraction CT angiography for the evaluation of intracranial aneurysms. AJNR Am J Neuroradiol 27:55–59PubMed
23.
Zurück zum Zitat Romijn M, Gratama van Andel HAF et al (2008) Diagnostic accuracy of CT angiography with matched mask bone elimination for detection of intracranial aneurysms: comparison with digital subtraction angiography and 3D rotational angiography. AJNR Am J Neuroradiol 29:134–139PubMedCrossRef Romijn M, Gratama van Andel HAF et al (2008) Diagnostic accuracy of CT angiography with matched mask bone elimination for detection of intracranial aneurysms: comparison with digital subtraction angiography and 3D rotational angiography. AJNR Am J Neuroradiol 29:134–139PubMedCrossRef
24.
Zurück zum Zitat Watanabe Y, Uotani K, Nakazawa T et al (2008) Dual-energy direct bone removal CT angiography for evaluation of intracranial aneurysm or stenosis: comparison with conventional digital subtraction angiography. Eur Radiol. doi:10.1007/s00330-008-1213-5 PubMed Watanabe Y, Uotani K, Nakazawa T et al (2008) Dual-energy direct bone removal CT angiography for evaluation of intracranial aneurysm or stenosis: comparison with conventional digital subtraction angiography. Eur Radiol. doi:10.​1007/​s00330-008-1213-5 PubMed
25.
Zurück zum Zitat Lell MM, Ruehm SG, Kramer M et al (2009) Cranial computed tomography angiography with automated bone subtraction: a feasibility study. Invest Radiol 44:38–43PubMedCrossRef Lell MM, Ruehm SG, Kramer M et al (2009) Cranial computed tomography angiography with automated bone subtraction: a feasibility study. Invest Radiol 44:38–43PubMedCrossRef
26.
Zurück zum Zitat Morhard D, Fink C, Becker C, Reiser MF, Nikolaou K (2008) Value of automatic bone subtraction in cranial CT angiography: comparison of bone-subtracted vs. standard CT angiography in 100 patients. Eur Radiol 18:974–982PubMedCrossRef Morhard D, Fink C, Becker C, Reiser MF, Nikolaou K (2008) Value of automatic bone subtraction in cranial CT angiography: comparison of bone-subtracted vs. standard CT angiography in 100 patients. Eur Radiol 18:974–982PubMedCrossRef
27.
Zurück zum Zitat Villablanca JP, Achiriolaie A, Hooshi P et al (2005) Aneurysms of the posterior circulation: detection and treatment planning using volume-rendered three-dimensional helical computerized tomography angiography. J Neurosurg 103:1018–1029PubMedCrossRef Villablanca JP, Achiriolaie A, Hooshi P et al (2005) Aneurysms of the posterior circulation: detection and treatment planning using volume-rendered three-dimensional helical computerized tomography angiography. J Neurosurg 103:1018–1029PubMedCrossRef
28.
Zurück zum Zitat Hoh BL, Cheung AC, Rabinov JD, Pryor JC, Carter BS, Ogilvy CS (2004) Results of a prospective protocol of computed tomographic angiography in place of catheter angiography as the only diagnostic and pretreatment planning study for cerebral aneurysms by a combined neurovascular team. Neurosurgery 54:1329–1340PubMedCrossRef Hoh BL, Cheung AC, Rabinov JD, Pryor JC, Carter BS, Ogilvy CS (2004) Results of a prospective protocol of computed tomographic angiography in place of catheter angiography as the only diagnostic and pretreatment planning study for cerebral aneurysms by a combined neurovascular team. Neurosurgery 54:1329–1340PubMedCrossRef
Metadaten
Titel
Subtraction CT angiography for evaluation of intracranial aneurysms: comparison with conventional CT angiography
verfasst von
Qi Li
Fajin Lv
Yongmei Li
Kewei Li
Tianyou Luo
Peng Xie
Publikationsdatum
01.09.2009
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 9/2009
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-009-1416-4

Weitere Artikel der Ausgabe 9/2009

European Radiology 9/2009 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.