Skip to main content
Erschienen in: European Radiology 10/2018

25.04.2018 | Cardiac

Subtraction CT angiography improves evaluation of significant coronary artery disease in patients with severe calcifications or stents—the C-Sub 320 multicenter trial

verfasst von: Andreas Fuchs, J. Tobias Kühl, Marcus Y. Chen, David Viladés Medel, Xavier Alomar, Sujata M. Shanbhag, Steffen Helqvist, Klaus F. Kofoed

Erschienen in: European Radiology | Ausgabe 10/2018

Einloggen, um Zugang zu erhalten

Abstract

Objectives

Diagnostic accuracy of conventional coronary CT angiography (CCTAconv) may be compromised by blooming artifacts from calcifications or stents. Blooming artifacts may be reduced by subtraction coronary CT angiography (CCTAsub) in which non-contrast and contrast CT data sets are subtracted digitally. We tested whether CCTAsub in patients with severe coronary calcification or stents reduces the number of false-positive stenosis evaluations compared with CCTAconv.

Methods

In this study, 180 symptomatic patients scheduled for invasive coronary angiography (ICA) were prospectively enrolled and CT scanned (2013-2016) at three international centers. CCTAconv, and CCTAsub data sets were reconstructed. Target segments were defined as motion-free coronary segments with a suspected stenosis (> 50% of lumen) potentially due to blooming of either calcium or stents. Target segments were evaluated with respect to misregistration artifacts from the CCTAsub reconstruction process, in which case evaluation was omitted. CCTAsub and CCTAconv were compared with ICA. Primary outcome measure was the frequency of false positives by CCTAconv versus CCTAsub to identify > 50% coronary stenosis by ICA on a per-segment level.

Results

After exclusion of 76 patients, 104 (14% females) with mean age 67 years and median Agatston score 852 were included. There were 136 target segments with misregistration and 121 target segments without. Accuracy calculations in target segments without misregistration showed a reduction of the false positives from 72% [95% confidence interval (CI): 63-80%] in CCTAconv to 33% (CI:25-42%) in CCTAsub, at the expense of 7% (CI:3-14%) false negatives in CCTAsub.

Conclusions

In severely calcified coronary arteries or stents, CCTAsub reduces the false-positive rate in well-aligned, calcified or stent segments suspected of significant stenosis on CCTAconv. Nevertheless, misregistration artifacts are frequent in CCTAsub.

Key Points

• A high calcium-score reduces the diagnostic accuracy in patients scanned with cardiac CT.
• These patients would normally need an invasive angiogram for diagnosis.
• In this prospective, multicenter study, subtraction CT, when evaluable, reduces false-positive stenosis evaluations.
• Subtraction coronary CT angiography may, when evaluable, reduce excessive downstream testing.
Literatur
1.
Zurück zum Zitat Montalescot G, Sechtem U, Achenbach S et al (2013) 2013 ESC guidelines on the management of stable coronary artery disease: the task force on the management of stable coronary artery disease of the European Society of Cardiology. Eur Heart J 34:2949–3003 Montalescot G, Sechtem U, Achenbach S et al (2013) 2013 ESC guidelines on the management of stable coronary artery disease: the task force on the management of stable coronary artery disease of the European Society of Cardiology. Eur Heart J 34:2949–3003
2.
Zurück zum Zitat Cury RC (2014) President's page: coronary CT angiography as a gatekeeper to the catheterization laboratory. J Cardiovasc Comput Tomogr 8:480–482CrossRef Cury RC (2014) President's page: coronary CT angiography as a gatekeeper to the catheterization laboratory. J Cardiovasc Comput Tomogr 8:480–482CrossRef
3.
Zurück zum Zitat Kuhl JT, Hove JD, Kristensen TS et al (2017) Coronary CT angiography in clinical triage of patients at high risk of coronary artery disease. Scand Cardiovasc J 51:28–34CrossRef Kuhl JT, Hove JD, Kristensen TS et al (2017) Coronary CT angiography in clinical triage of patients at high risk of coronary artery disease. Scand Cardiovasc J 51:28–34CrossRef
4.
Zurück zum Zitat Fuchs A, Kuhl JT, Chen MY et al (2015) Feasibility of coronary calcium and stent image subtraction using 320-detector row CT angiography. J Cardiovasc Comput Tomogr 9:393–398CrossRef Fuchs A, Kuhl JT, Chen MY et al (2015) Feasibility of coronary calcium and stent image subtraction using 320-detector row CT angiography. J Cardiovasc Comput Tomogr 9:393–398CrossRef
5.
Zurück zum Zitat Tanaka R, Yoshioka K, Muranaka K et al (2013) Improved evaluation of calcified segments on coronary CT angiography: a feasibility study of coronary calcium subtraction. Int J Cardiovasc Imaging 29(Suppl 2):75–81CrossRef Tanaka R, Yoshioka K, Muranaka K et al (2013) Improved evaluation of calcified segments on coronary CT angiography: a feasibility study of coronary calcium subtraction. Int J Cardiovasc Imaging 29(Suppl 2):75–81CrossRef
6.
Zurück zum Zitat Vilades MD, Leta R, Alomar SX, Carreras CF, Pons-Llado G (2016) Reliability of a new method for coronary artery calcium or metal subtraction by 320-row cardiac CT. Eur Radiol 26:3208–3214CrossRef Vilades MD, Leta R, Alomar SX, Carreras CF, Pons-Llado G (2016) Reliability of a new method for coronary artery calcium or metal subtraction by 320-row cardiac CT. Eur Radiol 26:3208–3214CrossRef
7.
Zurück zum Zitat Yoshioka K, Tanaka R, Takagi H et al (2016) Diagnostic accuracy of a modified subtraction coronary CT angiography method with short breath-holding time: a feasibility study. Br J Radiol 89:20160489CrossRef Yoshioka K, Tanaka R, Takagi H et al (2016) Diagnostic accuracy of a modified subtraction coronary CT angiography method with short breath-holding time: a feasibility study. Br J Radiol 89:20160489CrossRef
8.
Zurück zum Zitat Yoshioka K, Tanaka R, Nagata K et al (2016) Modified subtraction coronary CT angiography method for patients unable to perform long breath-holds: a preliminary study. Acad Radiol 23:1170–1175CrossRef Yoshioka K, Tanaka R, Nagata K et al (2016) Modified subtraction coronary CT angiography method for patients unable to perform long breath-holds: a preliminary study. Acad Radiol 23:1170–1175CrossRef
9.
Zurück zum Zitat Amanuma M, Kondo T, Sano T et al (2016) Assessment of coronary in-stent restenosis: value of subtraction coronary computed tomography angiography. Int J Cardiovasc Imaging 32:661–670CrossRef Amanuma M, Kondo T, Sano T et al (2016) Assessment of coronary in-stent restenosis: value of subtraction coronary computed tomography angiography. Int J Cardiovasc Imaging 32:661–670CrossRef
10.
Zurück zum Zitat Amanuma M, Kondo T, Sano T et al (2015) Subtraction coronary computed tomography in patients with severe calcification. Int J Cardiovasc Imaging 31:1635–1642CrossRef Amanuma M, Kondo T, Sano T et al (2015) Subtraction coronary computed tomography in patients with severe calcification. Int J Cardiovasc Imaging 31:1635–1642CrossRef
11.
Zurück zum Zitat Yoshioka K, Tanaka R, Muranaka K (2012) Subtraction coronary CT angiography for calcified lesions. Cardiol Clin 30:93–102CrossRef Yoshioka K, Tanaka R, Muranaka K (2012) Subtraction coronary CT angiography for calcified lesions. Cardiol Clin 30:93–102CrossRef
12.
Zurück zum Zitat Yoshioka K, Tanaka R (2011) Subtraction coronary CT angiography for the evaluation of severely calcified lesions using a 320-detector row scanner. Curr Cardiovasc Imaging Rep 4:437–446CrossRef Yoshioka K, Tanaka R (2011) Subtraction coronary CT angiography for the evaluation of severely calcified lesions using a 320-detector row scanner. Curr Cardiovasc Imaging Rep 4:437–446CrossRef
13.
Zurück zum Zitat Razeto M, Mohr B, Arakita K et al (2014) Accurate, fully automated registration of coronary arteries for volumetric CT digital subtraction angiography, Proc. SPIE 9034, Medical Imaging 2014: Image Processing, 90343F Razeto M, Mohr B, Arakita K et al (2014) Accurate, fully automated registration of coronary arteries for volumetric CT digital subtraction angiography, Proc. SPIE 9034, Medical Imaging 2014: Image Processing, 90343F
14.
Zurück zum Zitat Crum WR, Griffin LD, Hill DL, Hawkes DJ (2003) Zen and the art of medical image registration: correspondence, homology, and quality. NeuroImage 20:1425–1437CrossRef Crum WR, Griffin LD, Hill DL, Hawkes DJ (2003) Zen and the art of medical image registration: correspondence, homology, and quality. NeuroImage 20:1425–1437CrossRef
15.
Zurück zum Zitat Leipsic J, Abbara S, Achenbach S et al (2014) SCCT guidelines for the interpretation and reporting of coronary CT angiography: a report of the Society of Cardiovascular Computed Tomography Guidelines Committee. J Cardiovasc Comput Tomogr 8:342–358CrossRef Leipsic J, Abbara S, Achenbach S et al (2014) SCCT guidelines for the interpretation and reporting of coronary CT angiography: a report of the Society of Cardiovascular Computed Tomography Guidelines Committee. J Cardiovasc Comput Tomogr 8:342–358CrossRef
16.
Zurück zum Zitat Sorensen SK, Kuhl JT, Fuchs A et al (2017) Volume and dimensions of angiographically normal coronary arteries assessed by multidetector computed tomography. J Cardiovasc Comput Tomogr 11:295–301CrossRef Sorensen SK, Kuhl JT, Fuchs A et al (2017) Volume and dimensions of angiographically normal coronary arteries assessed by multidetector computed tomography. J Cardiovasc Comput Tomogr 11:295–301CrossRef
17.
Zurück zum Zitat Larsen LH, Kofoed KF, Dalsgaard M et al (2013) Assessment of coronary artery disease using coronary computed tomography angiography in patients with aortic valve stenosis referred for surgical aortic valve replacement. Int J Cardiol 168:126–131CrossRef Larsen LH, Kofoed KF, Dalsgaard M et al (2013) Assessment of coronary artery disease using coronary computed tomography angiography in patients with aortic valve stenosis referred for surgical aortic valve replacement. Int J Cardiol 168:126–131CrossRef
18.
Zurück zum Zitat Andrew M, John H (2015) The challenge of coronary calcium on coronary computed tomographic angiography (CCTA) scans: effect on interpretation and possible solutions. Int J Cardiovasc Imaging 31(Suppl 2):145–157CrossRef Andrew M, John H (2015) The challenge of coronary calcium on coronary computed tomographic angiography (CCTA) scans: effect on interpretation and possible solutions. Int J Cardiovasc Imaging 31(Suppl 2):145–157CrossRef
Metadaten
Titel
Subtraction CT angiography improves evaluation of significant coronary artery disease in patients with severe calcifications or stents—the C-Sub 320 multicenter trial
verfasst von
Andreas Fuchs
J. Tobias Kühl
Marcus Y. Chen
David Viladés Medel
Xavier Alomar
Sujata M. Shanbhag
Steffen Helqvist
Klaus F. Kofoed
Publikationsdatum
25.04.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 10/2018
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-018-5418-y

Weitere Artikel der Ausgabe 10/2018

European Radiology 10/2018 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.