Skip to main content
Erschienen in: Scoliosis and Spinal Disorders 1/2018

Open Access 01.12.2018 | Letter to the Editor

Supplementary Addendum to “Radiation dose of digital radiography (DR) versus micro-dose x-ray (EOS) on patients with adolescent idiopathic scoliosis: 2016 SOSORT- IRSSD “John Sevastic Award” Winner in Imaging Research”

verfasst von: Steve C. N. Hui, Winnie C. W. Chu

Erschienen in: Scoliosis and Spinal Disorders | Ausgabe 1/2018

Abstract

Regarding the publication entitle “Radiation dose of digital radiography (DR) versus micro-dose x-ray (EOS) on patients with adolescent idiopathic scoliosis: 2016 SOSORT- IRSSD “John Sevastic Award” Winner in Imaging Research” in Scoliosis and Spinal Disorders, we would like to provide more details to readers about the dose calculated by simulation using PCXMC 2.0. In this study, the data and results are correct based on the given parameters and calculation provided in the manuscript. In the simulation of EOS micro-dose, only a 0.1 mm copper filter was applied. We agree with the suggestion from Dr. Pedersen and colleagues that the inclusion of a 1.5 mm aluminum filter together with the 0.1 mm copper reflects more realistic representation of X-ray filtration which would improve the accuracy of the simulation. We believe that this supplementary addendum would be beneficial to other researchers who are planning to conduct a similar study.
We are writing to provide additional details regarding the article published by Hui et al. (Radiation dose of digital radiography (DR) versus micro-dose x-ray (EOS) on patients with adolescent idiopathic scoliosis: 2016 SOSORT- IRSSD “John Sevastic Award” Winner in Imaging Research, Scoliosis Spinal Disord. 2016 Dec 29;11:46. doi: https://​doi.​org/​10.​1186/​s13013-016-0106-7.). X-ray filters using copper or aluminum eliminate undesirable low-energy photons which affect the effective dose due to the change of energy spectrum of the X-ray beam and tissue absorption. The dose calculated by simulation using PCXMC 2.0 in this article was solely based on using parameters provided in Table 2 of Hui et al. 2016 which included only a 0.1 mm copper filter; the inherent 1.5 mm aluminum filter was omitted. We recalculated effective dose with the additional (aluminum) filtration, and this showed that the average effective dose for the EOS micro-dose protocol would be increased from 2.6 μSv as shown in Table 3 of Hui et al. 2016 to 3.1 μSv similar to the results obtained by Dr. Pedersen and colleagues as both copper and aluminum filters were applied (P. Pedersen, A. Greval and S. Eiskjær, personal communication, July 12, 2017). We suggest using both filters in simulations to determine results that best reflect real circumstance if other investigators plan to conduct similar studies.

Acknowledgements

We would like to thank Dr. Pedersen, Dr. Eiskjær, and Dr. Greval from the Aalborg University Hospital, Aalborg, Denmark, for their comments to improve the overall accuracy of our simulation process.

Funding

The original study was partially supported by the SH Ho Scoliosis Research Laboratory (7104486) and Kai Cheong Tong for equipment funding.

Availability of data and materials

The dataset supporting the conclusions of this article is included within Hui et al. 2016 and its Additional files.
The research protocol was approved by the Clinical Research Ethics Committee of the institution and conducted in compliance with the principles of Declaration of Helsinki. Written informed consents were obtained from both volunteers and their parent (or legal guardian).
Consent to publish has been obtained from all volunteers and their parent or legal guardian.

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
Metadaten
Titel
Supplementary Addendum to “Radiation dose of digital radiography (DR) versus micro-dose x-ray (EOS) on patients with adolescent idiopathic scoliosis: 2016 SOSORT- IRSSD “John Sevastic Award” Winner in Imaging Research”
verfasst von
Steve C. N. Hui
Winnie C. W. Chu
Publikationsdatum
01.12.2018
Verlag
BioMed Central
Erschienen in
Scoliosis and Spinal Disorders / Ausgabe 1/2018
Elektronische ISSN: 2397-1789
DOI
https://doi.org/10.1186/s13013-017-0148-5

Weitere Artikel der Ausgabe 1/2018

Scoliosis and Spinal Disorders 1/2018 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.