Skip to main content
Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology 4/2013

01.04.2013 | Glaucoma

Swept source optical coherence tomography measurement of the iris–trabecular contact (ITC) index: a new parameter for angle closure

verfasst von: Sue-Wei Ho, Mani Baskaran, Ce Zheng, Tin A. Tun, Shamira A. Perera, Arun K. Narayanaswamy, David S. Friedman, Tin Aung

Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology | Ausgabe 4/2013

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To evaluate the inter- and intra-observer agreement of measurement of the iris–trabecular contact (ITC) index, a measure of the degree of angle closure, using swept source optical coherence tomography (SSOCT, CASIA SS-1000, Tomey Corporation, Nagoya, Japan).

Methods

One randomly selected eye of 60 subjects was imaged under dark room conditions. The SSOCT 3-dimensional angle scan simultaneously obtains 128 radial scans of the anterior chamber for the entire circumference of the angle. Post-imaging analysis estimated the ITC index using in-built software. For intra-observer agreement for image grading, one examiner performed the grading twice in a masked fashion and random order after a 1-week interval. A second examiner graded images to assess inter-observer agreement for image grading. For intra-observer agreement for image acquisition, a single operator imaged patients twice. For inter-observer agreement for image acquisition, a single observer graded two sets of images acquired by two different operators on the same patient. Bland–Altman plots and 95 % limits of agreement (LOA) were reported.

Results

Study subjects were predominantly Chinese (54/60, 90 %) and female (42/60, 70 %), with a mean age of 65.5 years. The median ITC index for eyes with open angles (31/60) and closed angles was 20 % (95 % confidence interval [CI] — 13.6, 27.8) and 49 % (95%CI — 35.5, 69.2) respectively. The mean difference (95 % LOA) for intra-observer agreement for image grading and image acquisition were −0.8 % (−8.2, 6.5) and 0.6 % (−10.9, 9.7); corresponding inter- observer agreement were 0.1 % (−10, 10.1) and −0.3 % (−11.1, 10.5) respectively.

Conclusions

The inter- and intra-observer agreement of the ITC index, as a measure of extent of angle closure using SSOCT, was good.
Literatur
1.
Zurück zum Zitat Leung CK, Yung WH, Yiu CK, Lam SW, Leung DY, Tse RK, Tham CC, Chan WM, Lam DS (2006) Novel approach for anterior chamber angle analysis: anterior chamber angle detection with edge measurement and identification algorithm (ACADEMIA). Arch Ophthalmol 124:1395–1401PubMedCrossRef Leung CK, Yung WH, Yiu CK, Lam SW, Leung DY, Tse RK, Tham CC, Chan WM, Lam DS (2006) Novel approach for anterior chamber angle analysis: anterior chamber angle detection with edge measurement and identification algorithm (ACADEMIA). Arch Ophthalmol 124:1395–1401PubMedCrossRef
2.
Zurück zum Zitat Foster PJ, Johnson GJ (2001) Glaucoma in China: how big is the problem? Br J Ophthalmol 85:1277–1282PubMedCrossRef Foster PJ, Johnson GJ (2001) Glaucoma in China: how big is the problem? Br J Ophthalmol 85:1277–1282PubMedCrossRef
3.
Zurück zum Zitat Wu RY, Nongpiur ME, He MG, Sakata LM, Friedman DS, Chan YH, Lavanya R, Wong TY, Aung T (2011) Association of narrow angles with anterior chamber area and volume measured with anterior-segment optical coherence tomography. Arch Ophthalmol 129:569–574PubMedCrossRef Wu RY, Nongpiur ME, He MG, Sakata LM, Friedman DS, Chan YH, Lavanya R, Wong TY, Aung T (2011) Association of narrow angles with anterior chamber area and volume measured with anterior-segment optical coherence tomography. Arch Ophthalmol 129:569–574PubMedCrossRef
4.
Zurück zum Zitat Congdon N, Wang F, Tielsch JM (1992) Issues in the epidemiology and population based screening of primary angle-closure glaucoma. SurvOphthalmol 36:411–423 Congdon N, Wang F, Tielsch JM (1992) Issues in the epidemiology and population based screening of primary angle-closure glaucoma. SurvOphthalmol 36:411–423
5.
Zurück zum Zitat Yi JH, Hong S, Seong GJ, Kang SY, Ma KT, Kim CY (2008) Anterior chamber measurements by pentacam and AS-OCT in eyes with normal open angles. Korean J Ophthalmol 22:242–245PubMedCrossRef Yi JH, Hong S, Seong GJ, Kang SY, Ma KT, Kim CY (2008) Anterior chamber measurements by pentacam and AS-OCT in eyes with normal open angles. Korean J Ophthalmol 22:242–245PubMedCrossRef
6.
Zurück zum Zitat Narayanaswamy A, Sakata LM, He MG, Friedman DS, Chan YH, Lavanya R, Baskaran M, Foster PJ, Aung T (2010) Diagnostic performance of anterior chamber angle measurements for detecting eyes with narrow angles: an anterior segment OCT study. Arch Ophthalmol 128:1321–1327PubMedCrossRef Narayanaswamy A, Sakata LM, He MG, Friedman DS, Chan YH, Lavanya R, Baskaran M, Foster PJ, Aung T (2010) Diagnostic performance of anterior chamber angle measurements for detecting eyes with narrow angles: an anterior segment OCT study. Arch Ophthalmol 128:1321–1327PubMedCrossRef
7.
Zurück zum Zitat Wong HT, Lim MC, Sakata LM, Aung HT, Amerasinghe N, Friedman DS, Aung T (2009) High-definition optical coherence tomography imaging of the iridocorneal angle of the eye. Arch Ophthalmol 127:256–260PubMedCrossRef Wong HT, Lim MC, Sakata LM, Aung HT, Amerasinghe N, Friedman DS, Aung T (2009) High-definition optical coherence tomography imaging of the iridocorneal angle of the eye. Arch Ophthalmol 127:256–260PubMedCrossRef
8.
Zurück zum Zitat Wylegała E, Teper S, Nowinska AK, Milka M, Dobrowolski D (2009) Anterior segment imaging: Fourier-domain optical coherence tomography versus time-domain optical coherence tomography. J Cataract Refract Surg 35:1410–1414PubMedCrossRef Wylegała E, Teper S, Nowinska AK, Milka M, Dobrowolski D (2009) Anterior segment imaging: Fourier-domain optical coherence tomography versus time-domain optical coherence tomography. J Cataract Refract Surg 35:1410–1414PubMedCrossRef
9.
Zurück zum Zitat Sasidharan R (2008) South East Asia Glaucoma Interest Group. Appendix 6A. Gonioscopy. Asia Pacific glaucoma guidelines. Scientific Communications International, HongKong Sasidharan R (2008) South East Asia Glaucoma Interest Group. Appendix 6A. Gonioscopy. Asia Pacific glaucoma guidelines. Scientific Communications International, HongKong
10.
Zurück zum Zitat Liu S, Yu M, Ye C, Lam DS, Leung CK (2011) Anterior chamber angle imaging with swept-source optical coherence tomography: an investigation on variability of angle measurement. Invest Ophthalmol Vis Sci 52:8598–8603PubMedCrossRef Liu S, Yu M, Ye C, Lam DS, Leung CK (2011) Anterior chamber angle imaging with swept-source optical coherence tomography: an investigation on variability of angle measurement. Invest Ophthalmol Vis Sci 52:8598–8603PubMedCrossRef
11.
Zurück zum Zitat Rabsilber TM, Khoramnia R, Auffarth GU (2006) Anterior chamber measurements using Pentacam rotating Scheimpflug camera. J Cataract Refract Surg 32:456–459PubMedCrossRef Rabsilber TM, Khoramnia R, Auffarth GU (2006) Anterior chamber measurements using Pentacam rotating Scheimpflug camera. J Cataract Refract Surg 32:456–459PubMedCrossRef
Metadaten
Titel
Swept source optical coherence tomography measurement of the iris–trabecular contact (ITC) index: a new parameter for angle closure
verfasst von
Sue-Wei Ho
Mani Baskaran
Ce Zheng
Tin A. Tun
Shamira A. Perera
Arun K. Narayanaswamy
David S. Friedman
Tin Aung
Publikationsdatum
01.04.2013
Verlag
Springer-Verlag
Erschienen in
Graefe's Archive for Clinical and Experimental Ophthalmology / Ausgabe 4/2013
Print ISSN: 0721-832X
Elektronische ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-012-2158-6

Weitere Artikel der Ausgabe 4/2013

Graefe's Archive for Clinical and Experimental Ophthalmology 4/2013 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.