Skip to main content
Erschienen in: BMC Neurology 1/2015

Open Access 01.12.2015 | Research article

T1- vs. T2-based MRI measures of spinal cord volume in healthy subjects and patients with multiple sclerosis

verfasst von: Gloria Kim, Fariha Khalid, Vinit V. Oommen, Shahamat Tauhid, Renxin Chu, Mark A. Horsfield, Brian C. Healy, Rohit Bakshi

Erschienen in: BMC Neurology | Ausgabe 1/2015

download
DOWNLOAD
print
DRUCKEN
insite
SUCHEN

Abstract

Background

The reliable and efficient measurement of spinal cord atrophy is of growing interest in monitoring disease progression in multiple sclerosis (MS).

Methods

We compared T1- and T2-weighted MRI for measuring cervical spinal cord volume in 31 patients with MS and 18 age-matched controls (NC) from T1-weighted gradient recalled echo and T2-weighted fast spin-echo 1.5 T axial acquisitions. The two sequences were matched on slice thickness, signal averages and voxel size. An active surface software tool determined the normalized mean cervical cord cross-sectional area.

Results

T1-derived cord areas were higher than T2 areas in the whole cohort (estimated mean difference = 7.03 mm2 (8.89 %); 95 % Confidence Interval (CI): 5.91, 8.14; p < 0.0001) and in both groups separately. There were trends for lower spinal cord areas in MS vs. NC with both sequences. For the T1 cord area, the mean difference was 3.7 mm2 (4.55 %) (95 % CI: −1.36, 8.78; p = 0.15). For the T2 cord area, the difference was larger [mean difference 4.9 mm2 (6.52 %) (95 % CI: −0.83, 10.67); p = 0.091]. The T1 and T2 cord areas showed similar weak to moderate correlations with measures of clinical status and T2 spinal cord lesion volume in the MS group. Superficial spinal cord T2 lesions had no apparent confounding effect on the outlining tool. The mean intra-rater and inter-rater coefficients of variation ranged from 0.27 to 0.91 % for T1- and 0.66 to 0.99 % for T2-derived cord areas.

Conclusion

T2-weighted images may prove efficient for measuring cervical spinal cord atrophy in MS, with the added advantage of lesion detectability.
Hinweise

Competing interests

This study was supported in part by a grant to R. Bakshi from the National Multiple Sclerosis Society (RG3705-A-1). M. Horsfield is the owner of Xinapse Systems, Ltd, which produced the analysis software used in the study. There are no other competing interests.

Author’s contributions

RB and ST conceived the study and designed the protocol. MAH developed the software used for MRI analysis. GK, FK, and VO performed the image analysis. ST and RC provided technical assistance and study supervision. BCH provided statistical analysis. RB and GK drafted the manuscript. ST, FK, VO, MAH, RC, and BCH edited the manuscript for critical content. RB secured the funding and provided overall study supervision. All authors read and approved the final version of the manuscript.

Background

Brain and spinal cord lesions and atrophy are key MRI findings in the evaluation of patients with multiple sclerosis (MS). Many MRI segmentation methods have been developed to quantify spinal cord atrophy, including manual, semi-automated, and fully automated segmentation algorithms [110]. Manual outlining of axially acquired spinal cord images was initially used to monitor cord atrophy [6]. However, this lacked efficiency and precision. The use of edge-finding tools led to higher reproducibility by reducing user interactions [68]. In the past few years, the level of automation has increased in cord contouring algorithms. The active surface method [2] simply requires that the user marks the center of the cord on several vertebral levels of interest. This allows a rapid semi-automated segmentation by measuring the cord cross-sectional areas along the length of the extracted surface parameter [2]. Most recently, fully automated spinal cord segmentation methods have also been developed to produce reliable and accurate cord contouring [1, 10].
Spinal cord atrophy is most relevant to progressive forms of MS, i.e. primary progressive (PP) and secondary progressive (SP), in which it closely links to physical disability [26]. In most research settings, T1-weighted gradient recalled sequences are used to measure spinal cord volume. However, T2-weighted spin-echo sequences are more routinely used in MS clinics to assess lesions in addition to their potential role in measuring spinal cord volume. We compared two commonly-available sequences to measure cord volume: 1) T2-weighted fast spin-echo (FSE) sequences; 2) T1-weighted gradient recalled echo (GRE) sequences.

Methods

Subjects’ characteristics are listed in Table 1. In the MS group, disability was assessed by the Expanded Disability Status Scale (EDSS) and timed 25-foot walk. Subjects underwent cervical spinal cord MRI on the same Philips 1.5 T scanner. For both sequences, axial images were obtained with a voxel size of 0.898 × 0.898 × 3 mm (no interslice gaps) with the same inferior-superior coverage and 2 signal averages. One hundred fifty to 200 axial slices were acquired on each subject to cover the whole spinal cord from the foramen magnum to the inferior extent of the conus medullaris. For the purposes of this study, only slices extending from the superior aspect of the C1 vertebral body to the inferior aspect of C7 were analyzed. The repetition (TR) and echo (TE) times (in milliseconds) [mean (range)] were, for the GRE sequence, TR = 520 (439–612) and TE = 4.26 (4.24-4.34). For the FSE sequence, TR = 9436 (8822–10659); TE = 100 in all subjects. All subjects gave informed consent for this study, which was approved by the local ethics committee of Partners Health Care. This human research was in compliance with the Helsinki Declaration (http://​www.​wma.​net/​en/​30publications/​10policies/​b3/​index.​html).
Table 1
Subject characteristics
 
Multiple sclerosis
Normal controls
Number
N = 31
N = 18
Age (years) (mean ± SD)
43.3 ± 8.7
43.6 ± 8.1
Women, number (%)
21 (68 %)
14 (78 %)
Disease category, number (%)
  
 Relapsing-remitting
26 (84 %)
-
 Secondary progressive
4 (13 %)
-
 Primary progressive
1 (3 %)
-
Disease durationa (years) (mean ± SD)
9.0 ± 8.3
-
Expanded Disability Status Scale score (mean ± SD)
2.1 ± 2.1
-
Timed 25-foot walk (mean ± SD)
6.0 ± 5.2
-
T1 normalized cord area (mm2) (mean ± SD)
77.7 ± 10.6
81.4 ± 7.0
T2 normalized cord area (mm2) (mean ± SD)
70.2 ± 10.5
75.1 ± 9.0
SD standard deviation
atime since first symptoms
Image analysis was performed by a validated active surface method [2] using the Jim software package (v. 6.0 Xinapse Systems, West Bergholt, UK; www.​xinapse.​com). The whole cervical cord (C1 to C7) was measured (Fig. 1 shows sample images and segmentations). Spinal cord volume was normalized by dividing the total volume by the number of axial slices [3]. The operator analysis time per scan was the same for the T1 or T2 scans (~20 min). All MRI analysis was performed in a blinded manner, without knowledge of clinical details. To collect data on intra-rater and inter-rater reliability, five randomly chosen subjects (3 MS patients and 2 normal controls - NC) were analyzed. Two operators performed data analysis independently, with one rater analyzing the data a second time to assess intra-rater reliability.
In addition, the presence of T2 hyperintense lesions in the cervical spinal cord was analyzed in all subjects to determine whether spinal cord lesions affected the cord contouring tool (Table 2, Fig. 2). The total volume and total number of cervical spinal cord T2 lesions were assessed. The number of lesions adjacent to the outer surface of the cord and the number of T2 lesions causing errors in the cord contour algorithm were also assessed. To confirm whether lesions in contact with the outer surface of the spinal cord interfered with cord segmentation, both the segmented cord outline and lesion tracings were overlaid using Jim software.
Table 2
T2 hyperintense cervical spinal cord lesions in the MS group
Patient #
Total cervical lesion volume (mm3)
Total # of cervical lesions
# of lesions contacting outer spinal cord surface
# of lesions causing contouring error
1
0
0
-
-
2
43.5
1
0
-
3
0
0
-
-
4
66.4
1
0
-
5
0
0
-
-
6
161.8
2
0
-
7
0
0
-
-
8
67.2
2
0
-
9
337.8
4
3
0
10
50.5
1
0
-
11
0
0
-
-
12
181.8
2
0
-
13
0
0
-
-
14
164.6
1
0
-
15
53.8
1
0
-
16
782.3
5
2
0
17
0
0
-
-
18
553.3
4
2
0
19
394.0
4
1
0
20
104.8
3
0
-
21
0
0
-
-
22
0
0
-
-
23
0
0
-
-
24
293.3
4
1
0
25
285.8
5
0
-
26
28.4
1
0
-
27
0
0
-
-
28
110.9
3
0
-
29
163.9
4
0
-
30
0
0
-
-
31
754.7
1
1
0
Mean
148.4
1.6
0.5
0
SD
215.7
1.7
0.9
0
Range
0–782.3
0–5
0–3
0-0
To assess agreement between T1 and T2 normalized cord areas, their within-subject differences were calculated and a paired t-test assessed significance. A Bland-Altman plot of the average normalized cord area vs. the difference between the two measures depicted the agreement between the two scans. Student’s t-tests compared groups. Spearman’s rank or Pearson’s correlations linked MRI to MRI, age or clinical measures. A p <0.05 was considered significant.

Results

Considering all subjects, the T1 cord areas were higher than the T2 areas [estimated mean difference = 7.03 mm2; 95 % Confidence Interval (CI): 5.91, 8.14; p < 0.0001, Table 1, Fig. 3]. This represented an 8.89 % difference [(mean difference/mean T1 cord area) × 100 %] between the mean T1 and T2 cord areas. This was consistent across all subjects (with only one NC having a higher T2 than T1 normalized cord area) and persisted when analyzing the two groups separately [estimated mean difference in MS = 7.47 mm2 (9.61 %); 95 % CI: 6.29, 8.65, p < 0.0001; NC = 6.26 mm2 (7.69 %); 95 % CI: 3.86, 8.67; p < 0.0001].
Data regarding the presence of spinal cord lesions on T2-weighted images are shown in Table 2 and Fig. 2. No lesions were present in the NC group. Among the 31 MS patients, 19 (61 %) had at least one spinal cord lesion. Six of these patients had lesions in contact with the outer spinal cord surface, none of which caused visually-apparent errors in the cord contouring algorithm (Fig. 2).
There were trends for lower spinal cord areas in the MS vs. NC groups when measured from the T1- or T2-weighted images (Table 1). For the T1 cord area, the mean difference was 3.7 mm2 (4.55 %) (95 % CI: −1.36, 8.78; p = 0.15). For the T2 cord area, the difference was larger, with MS showing greater atrophy, but this again did not reach significance [mean difference 4.9 mm2 (6.52 %) (95 % CI: −0.83, 10.67); p = 0.091]. The percent differences between MS and NC groups were calculated as the (mean difference/mean NC area) × 100 %.
The T1 and T2 cord areas showed similar weak to moderate correlations with three measures of clinical status in the MS group (Table 3). Spinal cord area vs. EDSS was similarly significant with both T1 (p = 0.032) and T2 (p = 0.033) cord measures (Table 3). Similarly, both T1 (p = 0.04) and T2 (p = 0.07) cord area measures showed approximately the same degree of negative association with the total volume of cervical spinal cord T2 lesions (Table 3).
Table 3
Correlation between spinal cord area and other variables in the MS group (n = 31)
 
T1 normalized cord area
T2 normalized cord area
 
rs
p-value
rs
p-value
Age
−0.160
0.380
−0.200
0.290
Disease durationa
−0.249
0.177
−0.248
0.178
Expanded Disability Status Scale score
−0.386
0.032
−0.383
0.033
Timed 25-foot walk
−0.281
0.126
−0.260
0.157
Total cervical volume of spinal cord T2 lesions
−0.370
0.040
−0.330
0.070
r s Spearman coefficient
ayears since first symptoms
Across all subjects, there were no correlations between age and T1 areas (r = −0.002, p = 0.99) or T2 areas (r = −0.001, p = 0.995). The MS group data are shown in Table 3. Considering just the NC group, there was a trend to correlation between age and T1 areas (r = 0.453, p = 0.059) and T2 areas (r = 0.419, p = 0.083); the interpretation of these trends was hampered by the small sample size in the NC group.
The method was highly reproducible, with mean coefficients of variation (COVs) of 0.27 % (intra-rater) and 0.91 % (inter-rater) for normalized cord area measured from T1 sequences and 0.66 % (intra-rater) and 0.99 % (inter-rater) from T2 sequences.

Discussion

Despite differences in the volumes obtained, the two axial T1-weighted and T2-weighted sequences showed similar validity and reliability in the assessment of cervical spinal cord volume in MS. Regarding validity, the two measures showed similar differences between MS and NC and similar correlations with clinical measures in the MS group. Considering reliability, the intra-rater COV for each was acceptable.
A variety of acquisitions, including T1- and T2-weighted images can detect a relationship between spinal cord volume and MS disability [2, 510]. Spinal cord imaging is routine in MS care and provides unique and complementary information on disease severity that is not captured by brain MRI [8, 11, 12]. However, the “gold standard” images used to measure spinal cord volume in research settings (e.g. 3D T1-weighted, 1 mm isotropic voxels) are not typically feasible in routine care due to costs, scan time restrictions, and their questionable clinical applicability. Thus, clinically routine spinal cord images are more practical for large-scale MS studies. The T2-weighted FSE images have the added advantage of detecting inflammatory/demyelinating spinal cord lesions. Our results extend previous work [1, 2] and suggest that such images may provide a stand-alone tool to efficiently measure cervical spinal cord volume in MS.
In the present study, we showed no confounding effect of superficially placed T2 hyperintense spinal cord lesions on the accuracy of the cord contouring tool. However, it is important to note that we may not have seen an effect due to the fact that most of our MS patients were relapsing-remitting and the presence of spinal cord lesions was not ubiquitous. Future studies with larger sample sizes of progressive cases would be necessary to fully evaluate the potential confounding effect of lesions on the cord outline on T2-weighted images. Such progressive cohorts with more advanced disease will be required to fully evaluate the differences between MS and NC, which were not detected in our sample of mostly mildly disabled patients. While T2-weighted images showed high intra- and inter-rater reliability, the scan-rescan reliability remains to be determined. Longitudinal studies will uncover the sensitivity of T2-weighted images for monitoring spinal cord volume change and treatment effects. Further studies should also assess the role of 3D high-resolution scan acquisitions.

Conclusion

T2-weighted images may prove efficient for measuring cervical spinal cord atrophy in MS, showing comparable effect sizes to T1-weighted images with the added advantage of lesion detectability.

Acknowledgements

We thank Mohit Neema and Ashish Arora for technical assistance.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made.
The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.
The Creative Commons Public Domain Dedication waiver (https://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Competing interests

This study was supported in part by a grant to R. Bakshi from the National Multiple Sclerosis Society (RG3705-A-1). M. Horsfield is the owner of Xinapse Systems, Ltd, which produced the analysis software used in the study. There are no other competing interests.

Author’s contributions

RB and ST conceived the study and designed the protocol. MAH developed the software used for MRI analysis. GK, FK, and VO performed the image analysis. ST and RC provided technical assistance and study supervision. BCH provided statistical analysis. RB and GK drafted the manuscript. ST, FK, VO, MAH, RC, and BCH edited the manuscript for critical content. RB secured the funding and provided overall study supervision. All authors read and approved the final version of the manuscript.
Literatur
1.
Zurück zum Zitat De Leener B, Kadoury S, Cohen-Adad J. Robust, accurate and fast automatic segmentation of the spinal cord. Neuroimage. 2014;98:528–36.CrossRefPubMed De Leener B, Kadoury S, Cohen-Adad J. Robust, accurate and fast automatic segmentation of the spinal cord. Neuroimage. 2014;98:528–36.CrossRefPubMed
2.
Zurück zum Zitat Horsfield MA, Sala S, Neema M, Absinta M, Bakshi A, Sormani MP, et al. Rapid semi-automatic segmentation of the spinal cord from magnetic resonance images: application in multiple sclerosis. Neuroimage. 2010;50:446–55.CrossRefPubMedPubMedCentral Horsfield MA, Sala S, Neema M, Absinta M, Bakshi A, Sormani MP, et al. Rapid semi-automatic segmentation of the spinal cord from magnetic resonance images: application in multiple sclerosis. Neuroimage. 2010;50:446–55.CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Healy BC, Arora A, Hayden DL, Ceccarelli A, Tauhid SS, Neema M, et al. Approaches to normalization of spinal cord volume: application to multiple sclerosis. J Neuroimaging. 2010;22:12–9.CrossRef Healy BC, Arora A, Hayden DL, Ceccarelli A, Tauhid SS, Neema M, et al. Approaches to normalization of spinal cord volume: application to multiple sclerosis. J Neuroimaging. 2010;22:12–9.CrossRef
4.
Zurück zum Zitat Rocca MA, Horsfield MA, Sala S, Copetti M, Valsasina P, Mesaros S, et al. A multicenter assessment of cervical cord atrophy among MS clinical phenotypes. Neurology. 2011;76:2096–102.CrossRefPubMed Rocca MA, Horsfield MA, Sala S, Copetti M, Valsasina P, Mesaros S, et al. A multicenter assessment of cervical cord atrophy among MS clinical phenotypes. Neurology. 2011;76:2096–102.CrossRefPubMed
5.
Zurück zum Zitat Hickman SJ, Coulon O, Parker GJ, Barker GJ, Stevenson VL, Chard DT, et al. Application of a B-spline active surface technique to the measurement of cervical cord volume in multiple sclerosis from three-dimensional MR images. J Magn Reson Imaging. 2003;18:368–71.CrossRefPubMed Hickman SJ, Coulon O, Parker GJ, Barker GJ, Stevenson VL, Chard DT, et al. Application of a B-spline active surface technique to the measurement of cervical cord volume in multiple sclerosis from three-dimensional MR images. J Magn Reson Imaging. 2003;18:368–71.CrossRefPubMed
6.
Zurück zum Zitat Lin X, Tench CR, Evangelou N, Jaspan T, Constantinescu CS. Measurement of spinal cord atrophy in multiple sclerosis. J Neuroimaging. 2004;14 Suppl 3:20–6.CrossRef Lin X, Tench CR, Evangelou N, Jaspan T, Constantinescu CS. Measurement of spinal cord atrophy in multiple sclerosis. J Neuroimaging. 2004;14 Suppl 3:20–6.CrossRef
7.
Zurück zum Zitat Zivadinov R, Banas AC, Yella V, Abdelrahman N, Weinstock-Guttman B, Dwyer MG. Comparison of three different methods for measurement of cervical cord atrophy in multiple sclerosis. AJNR Am J Neuroradiol. 2008;29:319–25.CrossRefPubMed Zivadinov R, Banas AC, Yella V, Abdelrahman N, Weinstock-Guttman B, Dwyer MG. Comparison of three different methods for measurement of cervical cord atrophy in multiple sclerosis. AJNR Am J Neuroradiol. 2008;29:319–25.CrossRefPubMed
8.
Zurück zum Zitat Cohen AB, Neema M, Arora A, Dell’Oglio E, Benedict RH, Tauhid S, et al. The relationships among MRI-defined spinal cord involvement, brain involvement, and disability in multiple sclerosis. J Neuroimaging. 2012;22:122–8.CrossRefPubMed Cohen AB, Neema M, Arora A, Dell’Oglio E, Benedict RH, Tauhid S, et al. The relationships among MRI-defined spinal cord involvement, brain involvement, and disability in multiple sclerosis. J Neuroimaging. 2012;22:122–8.CrossRefPubMed
9.
Zurück zum Zitat Schlaeger R, Papinutto N, Panara V, Bevan C, Lobach IV, Bucci M, et al. Spinal cord gray matter atrophy correlates with multiple sclerosis disability. Ann Neurol. 2014;76:568–80.CrossRefPubMed Schlaeger R, Papinutto N, Panara V, Bevan C, Lobach IV, Bucci M, et al. Spinal cord gray matter atrophy correlates with multiple sclerosis disability. Ann Neurol. 2014;76:568–80.CrossRefPubMed
10.
Zurück zum Zitat Oh J, Seigo M, Saidha S, Sotirchos E, Zackowski K, Chen M, et al. Spinal cord normalization in multiple sclerosis. J Neuroimaging. 2014;24:577–84.CrossRefPubMedPubMedCentral Oh J, Seigo M, Saidha S, Sotirchos E, Zackowski K, Chen M, et al. Spinal cord normalization in multiple sclerosis. J Neuroimaging. 2014;24:577–84.CrossRefPubMedPubMedCentral
11.
Zurück zum Zitat Bot JC, Barkhof F, Polman CH, Lycklama à Nijeholt GJ, de Groot V, Bergers E, et al. Spinal cord abnormalities in recently diagnosed MS patients: added value of spinal MRI examination. Neurology. 2004;62:226–33.CrossRefPubMed Bot JC, Barkhof F, Polman CH, Lycklama à Nijeholt GJ, de Groot V, Bergers E, et al. Spinal cord abnormalities in recently diagnosed MS patients: added value of spinal MRI examination. Neurology. 2004;62:226–33.CrossRefPubMed
12.
Zurück zum Zitat Bakshi R, Neema M, Tauhid S, Healy BC, Glanz BI, Kim G, et al. An expanded composite scale of MRI-defined disease severity in multiple sclerosis: MRDSS2. Neuroreport. 2014;25:1156–61.CrossRefPubMedPubMedCentral Bakshi R, Neema M, Tauhid S, Healy BC, Glanz BI, Kim G, et al. An expanded composite scale of MRI-defined disease severity in multiple sclerosis: MRDSS2. Neuroreport. 2014;25:1156–61.CrossRefPubMedPubMedCentral
Metadaten
Titel
T1- vs. T2-based MRI measures of spinal cord volume in healthy subjects and patients with multiple sclerosis
verfasst von
Gloria Kim
Fariha Khalid
Vinit V. Oommen
Shahamat Tauhid
Renxin Chu
Mark A. Horsfield
Brian C. Healy
Rohit Bakshi
Publikationsdatum
01.12.2015
Verlag
BioMed Central
Erschienen in
BMC Neurology / Ausgabe 1/2015
Elektronische ISSN: 1471-2377
DOI
https://doi.org/10.1186/s12883-015-0387-0

Weitere Artikel der Ausgabe 1/2015

BMC Neurology 1/2015 Zur Ausgabe