01.12.2015 | Research article | Ausgabe 1/2015 Open Access

Testicular prostheses in patients with testicular cancer - acceptance rate and patient satisfaction
- Zeitschrift:
- BMC Urology > Ausgabe 1/2015
Electronic supplementary material
Competing interests
Authors’ contributions
Background
Methods
Statistical analysis
Results
Total
|
With prosthesis
|
||
---|---|---|---|
n (%)
|
n (%)
|
95% CI
|
|
Total sample
|
475 (100)
|
128 (26.9)
|
23.0%; 31.2%
|
Histology*
|
|||
Seminoma
|
293 (100)
|
81 (27.6)
|
22.6%; 33.1%
|
Nonseminoma
|
182 (100)
|
47 (25.8)
|
19.6%; 32.8%
|
Clinical stage**
|
|||
CS1
|
313 (100)
|
91 (29.1)
|
24.1%; 24.4%
|
CS 2
|
138 (100)
|
32 (23.2)
|
16.4%; 31.1%
|
CS 3
|
24 (100)
|
5 (20.8)
|
7.1%; 42.2%
|
Age at diagnosis
§
|
|||
≤20 years
|
16 (100)
|
4 (25.0)
|
7.3%; 52.2%
|
>20 - ≤ 30 years
|
103 (100)
|
34 (33.0)
|
24.1%; 43.0%
|
>30 - ≤ 40 years
|
206 (100)
|
61 (29.6)
|
23.5%; 36.4%
|
>40 - ≤ 50 years
|
113 (100)
|
25 (22.1)
|
14.9%; 30.9%
|
>50 - ≤ 60 years
|
37 (100)
|
4 (10.8)
|
3.0%; 25.4%
|
Treatment
#
|
|||
1997 - 2003
|
143 (100)
|
35 (24.5)
|
17.7%; 32.4%
|
2004 – 2009
|
167 (100)
|
55 (32.9)
|
25.9%; 40.6%
|
2010 – 2014
|
165 (100)
|
38 (23.0)
|
16.8%; 30.2%
|
Parameter
|
Odds ratio
|
95% Wald CI
|
p-value*
|
|
---|---|---|---|---|
Age (years)
|
0.05
|
|||
≤20 vs. > 30 - ≤ 40
|
1.06
|
0.31
|
3.62
|
|
>20 - ≤ 30 vs. > 30 - ≤ 40
|
1.28
|
0.75
|
2.17
|
|
>40 - ≤ 50 vs. > 30 - ≤ 40
|
0.64
|
0.37
|
1.11
|
|
>50 - ≤ 60 vs. > 30 - ≤ 40
|
0.28
|
0.09
|
0.82
|
|
Histology
|
0.50
|
|||
Seminoma yes vs. no
|
0.84
|
0.52
|
1.38
|
|
Clinical stage
|
0.33
|
|||
CS2 vs. CS1
|
0.71
|
0.43
|
1.15
|
|
CS3 vs. CS1
|
0.70
|
0.23
|
1.93
|
|
Year of treatment
|
0.09
|
|||
2004 - 09 vs. 1997 – 2003
|
1.65
|
0.99
|
2.74
|
|
2010-14 vs. 1997 – 2003
|
1.06
|
0.61
|
1.82
|
Question
|
Eligible (n)
|
Answer
|
(%)
|
95% CI
|
---|---|---|---|---|
Married
|
167
|
yes
|
50.3
|
41.4%; 59.2%
|
Living with permanent partner
|
164
|
yes
|
77.4
|
69.5%; 84.0%
|
Time living with implant
|
168
|
<1 year- 2 years > 2 years
|
14.9
|
9.3%; 22.3%
|
10.7
|
5.8%; 17.4%
|
|||
74.4
|
65.7%; 81.8%
|
|||
Additional surgery after implant insertion
|
170
|
yes
|
4.7
|
2.1%; 9.6%
|
Normal appearance with two testicles: important?
|
168
|
very important
|
53.6%
|
44.1%; 62.6%
|
important
|
31.3
|
23.2%; 40.6%
|
||
Being offered a prosthesis, preoperatively
|
169
|
important
|
98.2
|
94.2%; 99.6%
|
Size of the implant
|
164
|
too large
|
9.8
|
5.0%; 16.3%
|
too small
|
23.8
|
16.3%; 32.3%
|
||
Weight of the implant
|
166
|
too heavy
|
6.6
|
2.9%; 12.5%
|
Just right
|
91
|
84.4%; 95.2%
|
||
Shape of implant
|
169
|
not right
|
15.4
|
9.7%; 22.5%
|
Consistence of implant
|
164
|
too firm
|
52.4
|
43.4%; 61.1%
|
Position of implant within scrotum
|
165
|
too high
|
30.3
|
22.0%; 39.6%
|
Any particular feeling with the implant
|
164
|
convenient
|
16.5
|
10.0%; 24.6%
|
inconvenient
|
4.3
|
1.5%; 9.7%
|
||
strange
|
9.1
|
4.6%; 16.0%
|
||
Problems with implant during physical exercise
|
164
|
no
|
92.1
|
85.8%; 96.1%
|
Concerns about future problems with the implant
|
164
|
no
|
89.0
|
82.7%; 93.6%
|
Counseling before implant placement
|
164
|
too short
|
31.1
|
22.7%; 40.5%
|
Insufficient
|
8.5
|
4.2%: 14.9%
|
||
After all, would you have an implant again?
|
165
|
yes
|
86.1
|
79.1%; 91.4%
|
Over-all satisfied with implant
|
164
|
very well
|
31.1
|
22.2%; 41.0%
|
satisfied
|
52.4
|
42.1%; 62.4%
|
||
just so
|
12.2
|
6.5%; 20.0%
|
||
no
|
4.3
|
7.4%; 1.2%
|
Size of prosthesis
|
||||
---|---|---|---|---|
Too much
|
Just right
|
Too small
|
||
Weight of prosthesis
|
p = 0.032*
|
|||
Too heavy
|
18.8%
|
4.6%
|
7.9%
|
|
Right
|
81.3%
|
95.4%
|
81.6%
|
|
Too light
|
-
|
-
|
10.5%
|
|
Shape of prosthesis
|
p = 0.002
#
|
|||
Inconvenient
|
31.3%
|
8.3%
|
28.2%
|
|
Just right
|
68.8%
|
91.7%
|
71.8%
|
|
weight of prosthesis
|
||||
Position within scrotum
|
p = 0.023
§
|
|||
Right
|
81.8%
|
69.6%
|
-
|
|
Not right
|
18.2%
|
30.4%
|
100%
|
|
shape of prosthesis
|
||||
Consistency of prosthesis
|
p = 0.017
#
|
|||
Too firm
|
75%
|
48.6%
|
||
Convenient
|
25%
|
51.4%
|
||
consistency of prosthesis
|
||||
Position of prosthesis
|
p = 0.035*
|
|||
Right
|
61.6%
|
76.9%
|
||
Too high
|
38.4%
|
23.1%
|
Over-all satisfaction with testicular implant
|
||||||
---|---|---|---|---|---|---|
Very well
|
Well
|
Just so
|
Not much
|
Not at all
|
||
Size
|
p < 0.001*
|
|||||
Too large
|
7.8%
|
13.3%
|
-
|
-
|
33%
|
|
Right
|
82.4%
|
65.1%
|
31.6%
|
100%
|
-
|
|
Too small
|
9.8%
|
21.7%
|
68.4%
|
-
|
66.6%
|
|
Shape
|
p = 0.001**
|
|||||
Inconvenient
|
5.9%
|
14.0%
|
35.0%
|
-
|
66.7%
|
|
Convenient
|
94.1%
|
86.0%
|
65.0%
|
100%
|
33.3%
|
|
Consistence
|
p < 0.001**
|
|||||
Too firm
|
20.0%
|
62.8%
|
75.0%
|
100%
|
100%
|
|
Convenient
|
80.0%
|
37.2%
|
25.0%
|
-
|
-
|
Discussion
Author
|
Year
|
Country
|
(n)
|
Method
|
Over-all satisfaction
|
Have it again
|
Shape
|
Position
|
Size
|
Consistency
|
Other
|
---|---|---|---|---|---|---|---|---|---|---|---|
Petersen [
24]
|
1992
|
Ger
|
119
|
I
|
93%
|
93%
|
-
|
high 11%
|
19% too large
|
10% too firm
|
-
|
14% too small
|
|||||||||||
Lynch [
32]
|
1992
|
UK
|
19
|
Q
|
79%
|
95%
|
-
|
-
|
-
|
-
|
−
|
Incrocci [
33]
|
2001
|
NL
|
22
|
Q
|
95%
|
95%
|
-
|
-
|
-
|
29% inconvenient
|
–
|
Adshead [
22]
|
2001
|
UK
|
71
|
Q
|
73%
|
90%
|
32% not right
|
27% not right
|
37% inconvenient
|
-
|
30% weight inconvenient
|
Boy [
28]
|
2002
|
Ger
|
39
|
Q
|
97%
|
-
|
-
|
3% too high
|
36% not right
|
3% too firm
|
partners’ rating: 55% satisfied
|
Xylinas [
34]
|
2008
|
F
|
63
|
Q
|
96%
|
96%
|
12% not right
|
3% not right
|
5% too small
|
12% too firm
|
2% too cold
|
Yossepowitch [
21]
|
2011
|
Isr
|
86
|
I
|
88%
|
86%
|
-
|
39% too high
|
27% not right
|
73% too firm
|
after 2005 better results
|