Skip to main content
Erschienen in: Journal of Digital Imaging 1/2015

01.02.2015

Texture Feature Analysis for Computer-Aided Diagnosis on Pulmonary Nodules

verfasst von: Fangfang Han, Huafeng Wang, Guopeng Zhang, Hao Han, Bowen Song, Lihong Li, William Moore, Hongbing Lu, Hong Zhao, Zhengrong Liang

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 1/2015

Einloggen, um Zugang zu erhalten

Abstract

Differentiation of malignant and benign pulmonary nodules is of paramount clinical importance. Texture features of pulmonary nodules in CT images reflect a powerful character of the malignancy in addition to the geometry-related measures. This study first compared three well-known types of two-dimensional (2D) texture features (Haralick, Gabor, and local binary patterns or local binary pattern features) on CADx of lung nodules using the largest public database founded by Lung Image Database Consortium and Image Database Resource Initiative and then investigated extension from 2D to three-dimensional (3D) space. Quantitative comparison measures were made by the well-established support vector machine (SVM) classifier, the area under the receiver operating characteristic curves (AUC) and the p values from hypothesis t tests. While the three feature types showed about 90 % differentiation rate, the Haralick features achieved the highest AUC value of 92.70 % at an adequate image slice thickness, where a thinner or thicker thickness will deteriorate the performance due to excessive image noise or loss of axial details. Gain was observed when calculating 2D features on all image slices as compared to the single largest slice. The 3D extension revealed potential gain when an optimal number of directions can be found. All the observations from this systematic investigation study on the three feature types can lead to the conclusions that the Haralick feature type is a better choice, the use of the full 3D data is beneficial, and an adequate tradeoff between image thickness and noise is desired for an optimal CADx performance. These conclusions provide a guideline for further research on lung nodule differentiation using CT imaging.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
2.
Zurück zum Zitat Swensen SJ, Jett JR, Sloan JA, Midthun DE, Hartman TE, Sykes A-M, Aughenbaugh GL, Zink FE, Hillman SL, Noetzel GR, Marks RS, Clayton AC, Pairolero PC: Screening for lung cancer with low-dose spiral computed tomography. Am J Respir Crit Care Med 165(4):508–513, 2002PubMedCrossRef Swensen SJ, Jett JR, Sloan JA, Midthun DE, Hartman TE, Sykes A-M, Aughenbaugh GL, Zink FE, Hillman SL, Noetzel GR, Marks RS, Clayton AC, Pairolero PC: Screening for lung cancer with low-dose spiral computed tomography. Am J Respir Crit Care Med 165(4):508–513, 2002PubMedCrossRef
3.
Zurück zum Zitat MacMahon H, Austin JHM, Gamsu G, Herold CJ, Jett JR, Naidich DP, Patz EF, Swensen SJ: Guidelines for management of small pulmonary nodules detected on ct scans: a statement from the Fleischner society. Radiology 237:395–400, 2005PubMedCrossRef MacMahon H, Austin JHM, Gamsu G, Herold CJ, Jett JR, Naidich DP, Patz EF, Swensen SJ: Guidelines for management of small pulmonary nodules detected on ct scans: a statement from the Fleischner society. Radiology 237:395–400, 2005PubMedCrossRef
4.
Zurück zum Zitat Matsuki Y, Nakamura K, Watanabe H, Aoki T, Nakata H, Katsuragawa S, Doi K: Usefulness of an artificial neural network for differentiating benign from malignant pulmonary nodules on high-resolution CT: evaluation with receiver operating characteristic analysis. Am J Roentgenol 178:657–663, 2002CrossRef Matsuki Y, Nakamura K, Watanabe H, Aoki T, Nakata H, Katsuragawa S, Doi K: Usefulness of an artificial neural network for differentiating benign from malignant pulmonary nodules on high-resolution CT: evaluation with receiver operating characteristic analysis. Am J Roentgenol 178:657–663, 2002CrossRef
5.
Zurück zum Zitat Cardillo G, Regal M, Sera F, Di Martino M, Carbone L, Facciolo F, Martelli M: Videothoracoscopic management of the solitary pulmonary nodule: a single-institution study on 429 cases. Ann Thorac Surg 75:1607–1612, 2003PubMedCrossRef Cardillo G, Regal M, Sera F, Di Martino M, Carbone L, Facciolo F, Martelli M: Videothoracoscopic management of the solitary pulmonary nodule: a single-institution study on 429 cases. Ann Thorac Surg 75:1607–1612, 2003PubMedCrossRef
6.
Zurück zum Zitat Li F, Aoyama M, Shiraishi J, Abe H, Li Q, Suzuki K, Engelmann R, Sone S, MacMahon H, Doi K: Radiologists’ performance for differentiating benign from malignant lung nodules on high-resolution CT using computer estimated likelihood of malignancy. Am J Roentgenol 183:1209–1215, 2004CrossRef Li F, Aoyama M, Shiraishi J, Abe H, Li Q, Suzuki K, Engelmann R, Sone S, MacMahon H, Doi K: Radiologists’ performance for differentiating benign from malignant lung nodules on high-resolution CT using computer estimated likelihood of malignancy. Am J Roentgenol 183:1209–1215, 2004CrossRef
7.
Zurück zum Zitat Gould MK, Fletcher J, Iannettoni MD, Lynch WR, Midthun DE, Naidich DP, Ost DE: Evaluation of patients with pulmonary nodules: when is it lung cancer? ACCP Evid Based Clin Pract Guidelines Chest 132:108S–130S, 2007 Gould MK, Fletcher J, Iannettoni MD, Lynch WR, Midthun DE, Naidich DP, Ost DE: Evaluation of patients with pulmonary nodules: when is it lung cancer? ACCP Evid Based Clin Pract Guidelines Chest 132:108S–130S, 2007
8.
Zurück zum Zitat McNitt-Gray MF, Hart EM, Wyckoff N, Wyckoff N, Sayre JW, Goldin JG, Aberle DR: A pattern classification approach to characterizing solitary pulmonary nodules imaged on high resolution CT: preliminary results. Med Phys 26(6):880–888, 1999PubMedCrossRef McNitt-Gray MF, Hart EM, Wyckoff N, Wyckoff N, Sayre JW, Goldin JG, Aberle DR: A pattern classification approach to characterizing solitary pulmonary nodules imaged on high resolution CT: preliminary results. Med Phys 26(6):880–888, 1999PubMedCrossRef
9.
Zurück zum Zitat Li Q, Li F, Shiraishi J, Katsuragawa S, Sone S, Doi K: Investigation of new psychophysical measures for evaluation of similar images on thoracic computed tomography for distinction between benign and malignant nodules. Med Phys 30(10):2584–2593, 2003PubMedCrossRef Li Q, Li F, Shiraishi J, Katsuragawa S, Sone S, Doi K: Investigation of new psychophysical measures for evaluation of similar images on thoracic computed tomography for distinction between benign and malignant nodules. Med Phys 30(10):2584–2593, 2003PubMedCrossRef
10.
Zurück zum Zitat Zinovev D, Raicu D, Furst J, Armato III, SG: Predicting radiological panel opinions using a panel of machine learning classifiers. Algorithms 2:1473–1502, 2009CrossRef Zinovev D, Raicu D, Furst J, Armato III, SG: Predicting radiological panel opinions using a panel of machine learning classifiers. Algorithms 2:1473–1502, 2009CrossRef
11.
Zurück zum Zitat Yankelevitz DF, Reeves AP, Kostis WJ, et al: Small pulmonary nodules: volumetrically determined growth rates based on CT evaluation. Radiology 217:251–256, 2000PubMedCrossRef Yankelevitz DF, Reeves AP, Kostis WJ, et al: Small pulmonary nodules: volumetrically determined growth rates based on CT evaluation. Radiology 217:251–256, 2000PubMedCrossRef
12.
Zurück zum Zitat Goodman LR, Gulsun M, Washington L, Nagy PG, Piacsek KL: Inherent variability of CT lung nodule measurements in vivo using semiautomated volumetric measurements. Am J Roentgenol 186:989–994, 2006CrossRef Goodman LR, Gulsun M, Washington L, Nagy PG, Piacsek KL: Inherent variability of CT lung nodule measurements in vivo using semiautomated volumetric measurements. Am J Roentgenol 186:989–994, 2006CrossRef
13.
Zurück zum Zitat Iwano S, Nakamura T, Kamioka Y, Ishigaki T: Computer-aided diagnosis: a shape classification of pulmonary nodules imaged by high-resolution CT. Comput Med Imaging Graph 29:565–570, 2005PubMedCrossRef Iwano S, Nakamura T, Kamioka Y, Ishigaki T: Computer-aided diagnosis: a shape classification of pulmonary nodules imaged by high-resolution CT. Comput Med Imaging Graph 29:565–570, 2005PubMedCrossRef
14.
Zurück zum Zitat Way TW, Hadjiiski LM, Sahiner B, Chan H-P, Cascade PN, Kazerooni EA, Bogot N, Zhou C: Computer-aided diagnosis of pulmonary nodules on CT scans: segmentation and classification using 3D active contours. Med Phys 33(7):2323–2337, 2006PubMedCentralPubMedCrossRef Way TW, Hadjiiski LM, Sahiner B, Chan H-P, Cascade PN, Kazerooni EA, Bogot N, Zhou C: Computer-aided diagnosis of pulmonary nodules on CT scans: segmentation and classification using 3D active contours. Med Phys 33(7):2323–2337, 2006PubMedCentralPubMedCrossRef
15.
Zurück zum Zitat Saito H, Minamiya Y, Kawai H, Nakagawaa T, Ito a M, Hosonoa Y, Motoyamaa S, Hashimotob M, Ishiyamab K, Ogawa J-I: Usefulness of circumference difference for estimating the likelihood of malignancy in small solitary pulmonary nodules on CT. Lung Cancer 58:348–354, 2007PubMedCrossRef Saito H, Minamiya Y, Kawai H, Nakagawaa T, Ito a M, Hosonoa Y, Motoyamaa S, Hashimotob M, Ishiyamab K, Ogawa J-I: Usefulness of circumference difference for estimating the likelihood of malignancy in small solitary pulmonary nodules on CT. Lung Cancer 58:348–354, 2007PubMedCrossRef
16.
Zurück zum Zitat El-Baz A, Gimel’farb GL, Falk R, El-Ghar MA: Appearance Analysis for Diagnosing Malignant Lung Nodules. Proc. of IEEE International Symposium on Biomedical Imaging: From Nano to Macro (ISBI’10), Rotterdam, The Netherlands, April 14–17, 2010, 193–196 El-Baz A, Gimel’farb GL, Falk R, El-Ghar MA: Appearance Analysis for Diagnosing Malignant Lung Nodules. Proc. of IEEE International Symposium on Biomedical Imaging: From Nano to Macro (ISBI’10), Rotterdam, The Netherlands, April 14–17, 2010, 193–196
17.
Zurück zum Zitat El-Baz A, Nitzken M, Khalifa F, Elnakib A, Gimel’farb G, Falk R, El-Ghar MA: 3D shape analysis for early diagnosis of malignant lung nodules. Inf Process Med Imaging 22:772–783, 2011 El-Baz A, Nitzken M, Khalifa F, Elnakib A, Gimel’farb G, Falk R, El-Ghar MA: 3D shape analysis for early diagnosis of malignant lung nodules. Inf Process Med Imaging 22:772–783, 2011
18.
Zurück zum Zitat El-Baz A, Nitzken M, Vanbogaert E, Gimel’farb GL, Falk R, El-Ghar MA: A Novel Shape-Based Diagnostic Approach for Early Diagnosis of Lung Nodules. Proceedings of the 8th IEEE International Symposium on Biomedical Imaging, 2011, 137–140 El-Baz A, Nitzken M, Vanbogaert E, Gimel’farb GL, Falk R, El-Ghar MA: A Novel Shape-Based Diagnostic Approach for Early Diagnosis of Lung Nodules. Proceedings of the 8th IEEE International Symposium on Biomedical Imaging, 2011, 137–140
19.
Zurück zum Zitat El-Baz A, Gimel'farb GL, El-Ghar MA, Falk R: Appearance-Based Diagnostic System for Early Assessment of Malignant Lung Nodules. In: Proc. IEEE International Conference on Image Processing (ICIP’12), Orlando, Florida, USA, September 30-October 3, 2012, 1463–1466 El-Baz A, Gimel'farb GL, El-Ghar MA, Falk R: Appearance-Based Diagnostic System for Early Assessment of Malignant Lung Nodules. In: Proc. IEEE International Conference on Image Processing (ICIP’12), Orlando, Florida, USA, September 30-October 3, 2012, 1463–1466
20.
Zurück zum Zitat Vittitoe NF, Baker JA, Floyd CE: Fractal texture analysis in computer-aided diagnosis of solitary pulmonary nodules. Acad Radiol 4:96–101, 1997PubMedCrossRef Vittitoe NF, Baker JA, Floyd CE: Fractal texture analysis in computer-aided diagnosis of solitary pulmonary nodules. Acad Radiol 4:96–101, 1997PubMedCrossRef
21.
Zurück zum Zitat Sluimer IC, van Waes PF, Viergever MA, van Ginneken B: Computer-aided diagnosis in high resolution CT of the lungs. Med Phys 30(12):3081–3090, 2003PubMedCrossRef Sluimer IC, van Waes PF, Viergever MA, van Ginneken B: Computer-aided diagnosis in high resolution CT of the lungs. Med Phys 30(12):3081–3090, 2003PubMedCrossRef
22.
Zurück zum Zitat SK Vijai Anand: Segmentation and Coupled Textural Feature Classification for Lung Tumor Prediction. IEEE International Conference on Communication Control and Computing Technologies, 2010, 518–524 SK Vijai Anand: Segmentation and Coupled Textural Feature Classification for Lung Tumor Prediction. IEEE International Conference on Communication Control and Computing Technologies, 2010, 518–524
23.
Zurück zum Zitat Arai K, Herdiyeni Y, Okumura H: Comparison of 2D and 3D local binary pattern in lung cancer diagnosis. Int J Adv Comput Sci Appl 3(4):89–95, 2012 Arai K, Herdiyeni Y, Okumura H: Comparison of 2D and 3D local binary pattern in lung cancer diagnosis. Int J Adv Comput Sci Appl 3(4):89–95, 2012
24.
Zurück zum Zitat Haralick RM, Shanmugam K, Dinstein I: Textural features for image classification. IEEE Trans Syst Man Cybern SMC-3(6):610–621, 1973CrossRef Haralick RM, Shanmugam K, Dinstein I: Textural features for image classification. IEEE Trans Syst Man Cybern SMC-3(6):610–621, 1973CrossRef
25.
Zurück zum Zitat Gabor D: Theory of communication. J Inst Electr Eng 93(26):429–457, 1946 Gabor D: Theory of communication. J Inst Electr Eng 93(26):429–457, 1946
26.
Zurück zum Zitat Wang L, He D: Texture classification using texture spectrum. Pattern Recogn 23:905–910, 1990CrossRef Wang L, He D: Texture classification using texture spectrum. Pattern Recogn 23:905–910, 1990CrossRef
27.
Zurück zum Zitat Samuel G, Armato III, Mclennan G, Bidaut L, McNitt-Gray MF, Meyer CR, Reeves AP, Zhao B, Henschke CI, Hoffman EA, Kazerooni EA, MacMahon H, van Beek EJR, Yankelevitz D, Biancardi AM, Bland PH, Brown MS, Engelmann RM, Laderach GE, Max D, Pais RC, Qing DP-Y, Roberts RY, Smith AR, Starkey A, Batra P, Caligiuri P, Farooqi A, Gladish GW, Jude CM, Munden RF, Petkovska I, Quint LE, Schwartz LH, Sundaram B, Dodd LE, Fenimore C, Gur D, Petrick N, Freymann J, Kirby J, Hughes B, Casteele AV, Gupte S, Sallam M, Heath MD, Kuhn MH, Dharaiya E, Burns R, Fryd DS, Salganicoff M, Anand V, Shreter U, Vastagh S, Croft BY, Clarke LP: The Lung Image Database Consortium (LIDC) and Image Database Resource Initiative (IDRI): a completed reference database of lung nodules on CT scans. Med Phys 38:915–931, 2011CrossRef Samuel G, Armato III, Mclennan G, Bidaut L, McNitt-Gray MF, Meyer CR, Reeves AP, Zhao B, Henschke CI, Hoffman EA, Kazerooni EA, MacMahon H, van Beek EJR, Yankelevitz D, Biancardi AM, Bland PH, Brown MS, Engelmann RM, Laderach GE, Max D, Pais RC, Qing DP-Y, Roberts RY, Smith AR, Starkey A, Batra P, Caligiuri P, Farooqi A, Gladish GW, Jude CM, Munden RF, Petkovska I, Quint LE, Schwartz LH, Sundaram B, Dodd LE, Fenimore C, Gur D, Petrick N, Freymann J, Kirby J, Hughes B, Casteele AV, Gupte S, Sallam M, Heath MD, Kuhn MH, Dharaiya E, Burns R, Fryd DS, Salganicoff M, Anand V, Shreter U, Vastagh S, Croft BY, Clarke LP: The Lung Image Database Consortium (LIDC) and Image Database Resource Initiative (IDRI): a completed reference database of lung nodules on CT scans. Med Phys 38:915–931, 2011CrossRef
28.
Zurück zum Zitat Abdi H, Williams LJ: Principal component analysis. Wiley Interdiscip Rev Comput Stat 2:433–459, 2010CrossRef Abdi H, Williams LJ: Principal component analysis. Wiley Interdiscip Rev Comput Stat 2:433–459, 2010CrossRef
29.
Zurück zum Zitat Kamarainen J-K, Kyrki V, Kälviäinen H: Invariance properties of gabor filter-based features—overview and applications. IEEE Trans Image Process 15(5):1088–1099, 2006PubMedCrossRef Kamarainen J-K, Kyrki V, Kälviäinen H: Invariance properties of gabor filter-based features—overview and applications. IEEE Trans Image Process 15(5):1088–1099, 2006PubMedCrossRef
30.
Zurück zum Zitat Kruizinga P, Petkov N, Grigorescu SE: Comparison of Texture Features Based on Gabor Filters. Proceedings of the 10th International Conference on Image Analysis and Processing, Venice, Italy, September 27–29, 1999, 142–147 Kruizinga P, Petkov N, Grigorescu SE: Comparison of Texture Features Based on Gabor Filters. Proceedings of the 10th International Conference on Image Analysis and Processing, Venice, Italy, September 27–29, 1999, 142–147
31.
Zurück zum Zitat Petkov N, Kruizinga P: Computational models of visual neurons specialised in the detection of periodic and aperiodic oriented visual stimuli: bar and grating cells. Biol Cybern 76:83–96, 1997PubMedCrossRef Petkov N, Kruizinga P: Computational models of visual neurons specialised in the detection of periodic and aperiodic oriented visual stimuli: bar and grating cells. Biol Cybern 76:83–96, 1997PubMedCrossRef
32.
Zurück zum Zitat Jones JP, Palmer LA: An evaluation of the two-dimensional gabor filter model of simple receptive fields in cat striate cortex. J Neurophysiol 58:1233–1258, 1987PubMed Jones JP, Palmer LA: An evaluation of the two-dimensional gabor filter model of simple receptive fields in cat striate cortex. J Neurophysiol 58:1233–1258, 1987PubMed
33.
Zurück zum Zitat Ojala T, Pietikäinen M, Harwood D: A comparative study of texture measures with classification based on feature distributions. Pattern Recogn 29(1):51–59, 1996CrossRef Ojala T, Pietikäinen M, Harwood D: A comparative study of texture measures with classification based on feature distributions. Pattern Recogn 29(1):51–59, 1996CrossRef
34.
Zurück zum Zitat Ahonen T, Hadid A, Pietikäinen M: Face description with local binary patterns: application to face recognition. IEEE Trans Pattern Anal Mach Intell 28(12):2037–2041, 2006PubMedCrossRef Ahonen T, Hadid A, Pietikäinen M: Face description with local binary patterns: application to face recognition. IEEE Trans Pattern Anal Mach Intell 28(12):2037–2041, 2006PubMedCrossRef
35.
Zurück zum Zitat Heikkilä M, Pietikäinen M, Schmid C: Description of interest regions with local binary patterns. Pattern Recogn 42(3):425–436, 2009CrossRef Heikkilä M, Pietikäinen M, Schmid C: Description of interest regions with local binary patterns. Pattern Recogn 42(3):425–436, 2009CrossRef
36.
Zurück zum Zitat Philips C, Li D, Furst J, Raicu D: An Analysis of Co-Occurrence and Gabor Texture Classification in 2D and 3D. CARS 2008 Proceedings. Barcelona, Spain Philips C, Li D, Furst J, Raicu D: An Analysis of Co-Occurrence and Gabor Texture Classification in 2D and 3D. CARS 2008 Proceedings. Barcelona, Spain
37.
Zurück zum Zitat Zhang G, Wang T, Lu H, Zhang J, Liu X, Liang Z: CAD Based on 3D Texture Analysis for Virtual Colonoscopy. The 22nd International Congress and Exhibition, CARS 2008 Computer Assisted Radiology and Surgery, June 25–28, 2008, Barcelona, Spain: 17 Zhang G, Wang T, Lu H, Zhang J, Liu X, Liang Z: CAD Based on 3D Texture Analysis for Virtual Colonoscopy. The 22nd International Congress and Exhibition, CARS 2008 Computer Assisted Radiology and Surgery, June 25–28, 2008, Barcelona, Spain: 17
38.
Zurück zum Zitat Han F, Wang H, Song B, Zhang G, Lu H, et al: A New 3D Texture Feature Based Computer-Aided Diagnosis Approach to Differentiate Pulmonary Nodules. Proc. SPIE 8670, Medical Imaging 2013: Computer-Aided Diagnosis, 86702Z, February 28, 2013 Han F, Wang H, Song B, Zhang G, Lu H, et al: A New 3D Texture Feature Based Computer-Aided Diagnosis Approach to Differentiate Pulmonary Nodules. Proc. SPIE 8670, Medical Imaging 2013: Computer-Aided Diagnosis, 86702Z, February 28, 2013
39.
Zurück zum Zitat Philips C, Li D, Raicu D, Furst J: Directional Invariance of Co-Occurrence Matrices within the Liver. International Conference on Biocomputation, Bioinformatics, and Biomedical Technologies, 2008, 29–34 Philips C, Li D, Raicu D, Furst J: Directional Invariance of Co-Occurrence Matrices within the Liver. International Conference on Biocomputation, Bioinformatics, and Biomedical Technologies, 2008, 29–34
40.
Zurück zum Zitat Suykens J, Vandewalle J: Least squares support vector machine classifiers. Neural Process Lett 9(3):293–300, 1999CrossRef Suykens J, Vandewalle J: Least squares support vector machine classifiers. Neural Process Lett 9(3):293–300, 1999CrossRef
41.
Zurück zum Zitat Fritsch FN, Carlson RE: Monotone piecewise cubic interpolation. Soc Ind Appl Math 17(2):238–246, 1980 Fritsch FN, Carlson RE: Monotone piecewise cubic interpolation. Soc Ind Appl Math 17(2):238–246, 1980
42.
Zurück zum Zitat Han H, Li L, Han F, Zhang H, Moore W, Liang Z: Vector Quantization-Based Automatic Detection of Pulmonary Nodules in Thoracic CT Images. In Proc. of IEEE Nuclear Science Symposium and Medical Imaging Conference, Seoul, Korea, October 27 - November 2, 2013 Han H, Li L, Han F, Zhang H, Moore W, Liang Z: Vector Quantization-Based Automatic Detection of Pulmonary Nodules in Thoracic CT Images. In Proc. of IEEE Nuclear Science Symposium and Medical Imaging Conference, Seoul, Korea, October 27 - November 2, 2013
43.
Zurück zum Zitat Fan L, Song B, Gu X, Liang Z: Improved Computer-Aided Colonic Polyp Detection Using a Modified SVM Classifier with Adaptive Kernel. Conf Record IEEE NSS-MIC, in CD-ROM, 2012 Fan L, Song B, Gu X, Liang Z: Improved Computer-Aided Colonic Polyp Detection Using a Modified SVM Classifier with Adaptive Kernel. Conf Record IEEE NSS-MIC, in CD-ROM, 2012
44.
Zurück zum Zitat Zhang G, Liang Z, Song B, Zhu H, Lu H: A Virtual Pathology Model for Differentiation of Colonic Polyp Types for CT Colonography. The 98th Annual Meeting of the Radiological Society of North America (RSNA), 2012, 414 Zhang G, Liang Z, Song B, Zhu H, Lu H: A Virtual Pathology Model for Differentiation of Colonic Polyp Types for CT Colonography. The 98th Annual Meeting of the Radiological Society of North America (RSNA), 2012, 414
45.
Zurück zum Zitat Song B, Zhang G, Zhu H, Zhu W, Lu H, Liang Z: A Feasibility Study of High Order Volumetric Texture Features for Computer Aided Diagnosis of Polyps via CT Colonography. Conf Record IEEE NSS-MIC, in CD-ROM, 2012 Song B, Zhang G, Zhu H, Zhu W, Lu H, Liang Z: A Feasibility Study of High Order Volumetric Texture Features for Computer Aided Diagnosis of Polyps via CT Colonography. Conf Record IEEE NSS-MIC, in CD-ROM, 2012
46.
Zurück zum Zitat Wang J, Li T, Hongbing L, Liang Z: Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose x-ray CT. IEEE Trans Med Imaging 25(10):1272–1283, 2006PubMedCentralPubMedCrossRef Wang J, Li T, Hongbing L, Liang Z: Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose x-ray CT. IEEE Trans Med Imaging 25(10):1272–1283, 2006PubMedCentralPubMedCrossRef
47.
Zurück zum Zitat Liu Y, Ma J, Fan Y, Liang Z: Adaptive-weighted total variation minimization for low-dose X-ray computed tomography image reconstruction. Phys Med Biol 57:7923–7956, 2012PubMedCentralPubMedCrossRef Liu Y, Ma J, Fan Y, Liang Z: Adaptive-weighted total variation minimization for low-dose X-ray computed tomography image reconstruction. Phys Med Biol 57:7923–7956, 2012PubMedCentralPubMedCrossRef
Metadaten
Titel
Texture Feature Analysis for Computer-Aided Diagnosis on Pulmonary Nodules
verfasst von
Fangfang Han
Huafeng Wang
Guopeng Zhang
Hao Han
Bowen Song
Lihong Li
William Moore
Hongbing Lu
Hong Zhao
Zhengrong Liang
Publikationsdatum
01.02.2015
Verlag
Springer US
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 1/2015
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-014-9718-8

Weitere Artikel der Ausgabe 1/2015

Journal of Digital Imaging 1/2015 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.