Skip to main content
Erschienen in: Clinical Orthopaedics and Related Research® 1/2009

01.01.2009 | Symposium: Papers Presented at the Hip Society Meetings 2008

The 2008 Frank Stinchfield Award: Variation in Postoperative Pelvic Tilt May Confound the Accuracy of Hip Navigation Systems

verfasst von: Sebastien Parratte, MD, Mark W. Pagnano, MD, Krista Coleman-Wood, PT, PhD, Kenton R. Kaufman, PhD, Daniel J. Berry, MD

Erschienen in: Clinical Orthopaedics and Related Research® | Ausgabe 1/2009

Einloggen, um Zugang zu erhalten

Abstract

Most computer navigation systems used in total hip arthroplasty integrate preoperative pelvic tilt to calculate the anterior pelvic plane assuming tilt is constant; however, the consistency of pelvic tilt after THA has never been proven. Therefore, using a modern comprehensive gait analysis before and after arthroplasty we sought to compare (1) dynamic pelvic tilt changes and (2) pelvic flexion/extension range-of-motion changes. Twenty-one patients who underwent unilateral THA were prospectively studied. Quantitative pelvic tilt changes (in the sagittal plane) and pelvic range of flexion/extension motion relative to a laboratory coordinate system were compared using a computerized video motion system. Mean gait pelvic tilt was 13.9º ± 4.8º (range, 1.73º–23.1º) preoperatively, 12.5º ± 4.5º (range, 1.4º–18.7º) 2 months postoperatively, and 10.5° ± 5.5º (range, –2.36º–19.2º) 12 months postoperatively. A significant proportion (31%) of patients had more than a 5° difference between preoperative and 12-month postoperative measurements and the variability was spread over 20°. Significant dynamic changes in pelvic tilt occurred after THA. While navigation clearly improves the anatomical position of the component during THA, the functional position of the component will not always be improved because of the significant change between preoperative and postoperative pelvic tilt.
Literatur
1.
Zurück zum Zitat Biedermann R, Tonin A, Krismer M, Rachbauer F, Eibl G, Stockl B. Reducing the risk of dislocation after total hip arthroplasty: the effect of orientation of the acetabular component. J Bone Joint Surg Br. 2005;87:762–769.PubMedCrossRef Biedermann R, Tonin A, Krismer M, Rachbauer F, Eibl G, Stockl B. Reducing the risk of dislocation after total hip arthroplasty: the effect of orientation of the acetabular component. J Bone Joint Surg Br. 2005;87:762–769.PubMedCrossRef
2.
Zurück zum Zitat Blendea S, Eckman K, Jaramaz B, Levison TJ, Digioia AM 3rd. Measurements of acetabular cup position and pelvic spatial orientation after total hip arthroplasty using computed tomography/radiography matching. Comput Aided Surg. 2005;10:37–43.PubMedCrossRef Blendea S, Eckman K, Jaramaz B, Levison TJ, Digioia AM 3rd. Measurements of acetabular cup position and pelvic spatial orientation after total hip arthroplasty using computed tomography/radiography matching. Comput Aided Surg. 2005;10:37–43.PubMedCrossRef
3.
Zurück zum Zitat DiGioia AM, Hafez MA, Jaramaz B, Levison TJ, Moody JE. Functional pelvic orientation measured from lateral standing and sitting radiographs. Clin Orthop Relat Res. 2006;453:272–276.PubMedCrossRef DiGioia AM, Hafez MA, Jaramaz B, Levison TJ, Moody JE. Functional pelvic orientation measured from lateral standing and sitting radiographs. Clin Orthop Relat Res. 2006;453:272–276.PubMedCrossRef
4.
Zurück zum Zitat DiGioia AM, Jaramaz B, Blackwell M, Simon DA, Morgan F, Moody JE, Nikou C, Colgan BD, Aston CA, Labarca RS, Kischell E, Kanade T. The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment. Clin Orthop Relat Res. 1998;355:8–22.PubMedCrossRef DiGioia AM, Jaramaz B, Blackwell M, Simon DA, Morgan F, Moody JE, Nikou C, Colgan BD, Aston CA, Labarca RS, Kischell E, Kanade T. The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment. Clin Orthop Relat Res. 1998;355:8–22.PubMedCrossRef
5.
Zurück zum Zitat Digioia AM 3rd, Jaramaz B, Plakseychuk AY, Moody JE Jr, Nikou C, Labarca RS, Levison TJ, Picard F. Comparison of a mechanical acetabular alignment guide with computer placement of the socket. J Arthroplasty. 2002;17:359–364.PubMedCrossRef Digioia AM 3rd, Jaramaz B, Plakseychuk AY, Moody JE Jr, Nikou C, Labarca RS, Levison TJ, Picard F. Comparison of a mechanical acetabular alignment guide with computer placement of the socket. J Arthroplasty. 2002;17:359–364.PubMedCrossRef
6.
Zurück zum Zitat D’Lima DD, Urquhart AG, Buehler KO, Walker RH, Colwell CW, Jr. The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios. J Bone Joint Surg Am. 2000;82:315–321.PubMed D’Lima DD, Urquhart AG, Buehler KO, Walker RH, Colwell CW, Jr. The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios. J Bone Joint Surg Am. 2000;82:315–321.PubMed
7.
Zurück zum Zitat Eckman K, Hafez MA, Ed F, Jaramaz B, Levison TJ, Digioia AM, 3rd. Accuracy of pelvic flexion measurements from lateral radiographs. Clin Orthop Relat Res. 2006;451:154–160.PubMedCrossRef Eckman K, Hafez MA, Ed F, Jaramaz B, Levison TJ, Digioia AM, 3rd. Accuracy of pelvic flexion measurements from lateral radiographs. Clin Orthop Relat Res. 2006;451:154–160.PubMedCrossRef
8.
Zurück zum Zitat Eddine TA, Migaud H, Chantelot C, Cotten A, Fontaine C, Duquennoy A. Variations of pelvic anteversion in the lying and standing positions: analysis of 24 control subjects and implications for CT measurement of position of a prosthetic cup. Surg Radiol Anat. 2001;23:105–110.PubMedCrossRef Eddine TA, Migaud H, Chantelot C, Cotten A, Fontaine C, Duquennoy A. Variations of pelvic anteversion in the lying and standing positions: analysis of 24 control subjects and implications for CT measurement of position of a prosthetic cup. Surg Radiol Anat. 2001;23:105–110.PubMedCrossRef
9.
Zurück zum Zitat Hurwitz DE, Hulet CH, Andriacchi TP, Rosenberg AG, Galante JO. Gait compensations in patients with osteoarthritis of the hip and their relationship to pain and passive hip motion. J Orthop Res. 1997;15:629–635.PubMedCrossRef Hurwitz DE, Hulet CH, Andriacchi TP, Rosenberg AG, Galante JO. Gait compensations in patients with osteoarthritis of the hip and their relationship to pain and passive hip motion. J Orthop Res. 1997;15:629–635.PubMedCrossRef
10.
Zurück zum Zitat Jolles BM, Zangger P, Leyvraz PF. Factors predisposing to dislocation after primary total hip arthroplasty: a multivariate analysis. J Arthroplasty. 2002;17:282–288.PubMedCrossRef Jolles BM, Zangger P, Leyvraz PF. Factors predisposing to dislocation after primary total hip arthroplasty: a multivariate analysis. J Arthroplasty. 2002;17:282–288.PubMedCrossRef
11.
Zurück zum Zitat Kalteis T, Handel M, Bathis H, Perlick L, Tingart M, Grifka J. Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation? J Bone Joint Surg Br. 2006;88:163–167.PubMedCrossRef Kalteis T, Handel M, Bathis H, Perlick L, Tingart M, Grifka J. Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation? J Bone Joint Surg Br. 2006;88:163–167.PubMedCrossRef
12.
Zurück zum Zitat Kennedy JG, Rogers WB, Soffe KE, Sullivan RJ, Griffen DG, Sheehan LJ. Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration. J Arthroplasty. 1998;13:530–534.PubMedCrossRef Kennedy JG, Rogers WB, Soffe KE, Sullivan RJ, Griffen DG, Sheehan LJ. Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration. J Arthroplasty. 1998;13:530–534.PubMedCrossRef
13.
Zurück zum Zitat Lembeck B, Mueller O, Reize P, Wuelker N. Pelvic tilt makes acetabular cup navigation inaccurate. Acta Orthop. 2005;76:517–523.PubMedCrossRef Lembeck B, Mueller O, Reize P, Wuelker N. Pelvic tilt makes acetabular cup navigation inaccurate. Acta Orthop. 2005;76:517–523.PubMedCrossRef
14.
Zurück zum Zitat Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60:217–20.PubMed Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60:217–20.PubMed
15.
Zurück zum Zitat McCollum DE, Gray WJ. Dislocation after total hip arthroplasty. Causes and prevention. Clin Orthop Relat Res. 1990;261:159–170.PubMed McCollum DE, Gray WJ. Dislocation after total hip arthroplasty. Causes and prevention. Clin Orthop Relat Res. 1990;261:159–170.PubMed
16.
Zurück zum Zitat McKibbin B. Anatomical factors in the stability of the hip joint in the newborn. J Bone Joint Surg Br. 1970;52:148–159.PubMed McKibbin B. Anatomical factors in the stability of the hip joint in the newborn. J Bone Joint Surg Br. 1970;52:148–159.PubMed
17.
Zurück zum Zitat Miki H, Sugano N, Hagio K, Nishii T, Kawakami H, Kakimoto A, Nakamura N, Yoshikawa H. Recovery of walking speed and symmetrical movement of the pelvis and lower extremity joints after unilateral THA. J Biomech. 2004;37:443–455.PubMedCrossRef Miki H, Sugano N, Hagio K, Nishii T, Kawakami H, Kakimoto A, Nakamura N, Yoshikawa H. Recovery of walking speed and symmetrical movement of the pelvis and lower extremity joints after unilateral THA. J Biomech. 2004;37:443–455.PubMedCrossRef
18.
Zurück zum Zitat Nishihara S, Sugano N, Nishii T, Ohzono K, Yoshikawa H. Measurements of pelvic flexion angle using three-dimensional computed tomography. Clin Orthop Relat Res. 2003;411:140–151.PubMedCrossRef Nishihara S, Sugano N, Nishii T, Ohzono K, Yoshikawa H. Measurements of pelvic flexion angle using three-dimensional computed tomography. Clin Orthop Relat Res. 2003;411:140–151.PubMedCrossRef
19.
Zurück zum Zitat Pagnano MW, Trousdale RT, Meneghini RM, Hanssen AD. Patients preferred a mini-posterior THA to a contralateral two-incision THA. Clin Orthop Relat Res. 2006;453:156–159.PubMedCrossRef Pagnano MW, Trousdale RT, Meneghini RM, Hanssen AD. Patients preferred a mini-posterior THA to a contralateral two-incision THA. Clin Orthop Relat Res. 2006;453:156–159.PubMedCrossRef
20.
Zurück zum Zitat Parratte S, Argenson JN. Validation and usefulness of a computer-assisted cup-positioning system in total hip arthroplasty. A prospective, randomized, controlled study. J Bone Joint Surg Am. 2007;89:494–499.PubMedCrossRef Parratte S, Argenson JN. Validation and usefulness of a computer-assisted cup-positioning system in total hip arthroplasty. A prospective, randomized, controlled study. J Bone Joint Surg Am. 2007;89:494–499.PubMedCrossRef
21.
Zurück zum Zitat Sloan DA, Donnelly MB, Schwartz RW, Strodel WE. The Objective Structured Clinical Examination. The new gold standard for evaluating postgraduate clinical performance. Ann Surg. 1995;222:735–742.PubMedCrossRef Sloan DA, Donnelly MB, Schwartz RW, Strodel WE. The Objective Structured Clinical Examination. The new gold standard for evaluating postgraduate clinical performance. Ann Surg. 1995;222:735–742.PubMedCrossRef
22.
Zurück zum Zitat Sutherland DH, Olshen R, Biden EN, Wyatt MP. Modeling and prediction regions for motion data. In: The Development of Mature Walking. Oxford, UK/Philadelphia, PA: Blackwell/Lippincott; 1988:24–32. Sutherland DH, Olshen R, Biden EN, Wyatt MP. Modeling and prediction regions for motion data. In: The Development of Mature Walking. Oxford, UK/Philadelphia, PA: Blackwell/Lippincott; 1988:24–32.
23.
Zurück zum Zitat Vogt L, Brettmann K, Pfeifer K, Banzer W. Walking patterns of hip arthroplasty patients: some observations on the medio-lateral excursions of the trunk. Disabil Rehabil. 2003;25:309–317.PubMedCrossRef Vogt L, Brettmann K, Pfeifer K, Banzer W. Walking patterns of hip arthroplasty patients: some observations on the medio-lateral excursions of the trunk. Disabil Rehabil. 2003;25:309–317.PubMedCrossRef
24.
Zurück zum Zitat Vogt L, Portscher M, Brettmann K, Pfeifer K, Banzer W. Cross-validation of marker configurations to measure pelvic kinematics in gait. Gait Posture. 2003;18:178–184.PubMedCrossRef Vogt L, Portscher M, Brettmann K, Pfeifer K, Banzer W. Cross-validation of marker configurations to measure pelvic kinematics in gait. Gait Posture. 2003;18:178–184.PubMedCrossRef
25.
Zurück zum Zitat Wolf A, Digioia AM 3rd, Mor AB, Jaramaz B. Cup alignment error model for total hip arthroplasty. Clin Orthop Relat Res. 2005;437:132–137.PubMedCrossRef Wolf A, Digioia AM 3rd, Mor AB, Jaramaz B. Cup alignment error model for total hip arthroplasty. Clin Orthop Relat Res. 2005;437:132–137.PubMedCrossRef
26.
Zurück zum Zitat Wolf A, DiGioia AM, 3rd, Mor AB, Jaramaz B. A kinematic model for calculating cup alignment error during total hip arthroplasty. J Biomech. 2005;38:2257–2265.PubMedCrossRef Wolf A, DiGioia AM, 3rd, Mor AB, Jaramaz B. A kinematic model for calculating cup alignment error during total hip arthroplasty. J Biomech. 2005;38:2257–2265.PubMedCrossRef
Metadaten
Titel
The 2008 Frank Stinchfield Award: Variation in Postoperative Pelvic Tilt May Confound the Accuracy of Hip Navigation Systems
verfasst von
Sebastien Parratte, MD
Mark W. Pagnano, MD
Krista Coleman-Wood, PT, PhD
Kenton R. Kaufman, PhD
Daniel J. Berry, MD
Publikationsdatum
01.01.2009
Verlag
Springer-Verlag
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 1/2009
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-008-0521-z

Weitere Artikel der Ausgabe 1/2009

Clinical Orthopaedics and Related Research® 1/2009 Zur Ausgabe

Symposium: Papers Presented at the Hip Society Meetings 2008

Midterm to Long-term Followup of Staged Reimplantation for Infected Hip Arthroplasty

Symposium: Papers Presented at the Hip Society Meetings 2008

Incidence and Characteristics of Femoral Deformities in the Dysplastic Hip

Symposium: Papers Presented at the Hip Society Meetings 2008

Survivorship of 2000 Tapered Titanium Porous Plasma-sprayed Femoral Components

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.