The Ability of Stroke Volume Variation Measured by a Noninvasive Cardiac Output Monitor to Predict Fluid Responsiveness in Mechanically Ventilated Children

verfasst von: Ji Yeon Lee, Ji Young Kim, Chang Hyu Choi, Hong Soon Kim, Kyung Cheon Lee, Hyun Jeong Kwak

Erschienen in: Pediatric Cardiology | Ausgabe 2/2014

Einloggen, um Zugang zu erhalten

Abstract

Continuous noninvasive cardiac output monitoring (NICOM) is a clinically useful tool in the pediatric setting. This study compared the ability of stroke volume variation (SVV) measured by NICOM with that of respiratory variations in the velocity of aortic blood flow (△Vpeak) and central venous pressure (CVP) to predict of fluid responsiveness in mechanically ventilated children after ventricular septal defect repair. The study investigated 26 mechanically ventilated children after the completion of surgery. At 30 min after their arrival in an intensive care unit, a colloid solution of 10 ml/kg was administrated for volume expansion. Hemodynamic variables, including CVP, stroke volume, and △Vpeak in addition to cardiac output and SVV in NICOM were measured before and 10 min after volume expansion. The patients with a stroke volume increase of more than 15 % after volume expansion were defined as responders. The 26 patients in the study consisted of 13 responders and 13 nonresponders. Before volume expansion, △Vpeak and SVV were higher in the responders (both p values <0.001). The areas under the receiver operating characteristic curves of △Vpeak, SVV, and CVP were respectively 0.956 (95 % CI 0.885–1.00), 0.888 (95 % CI 0.764–1.00), and 0.331 (95 % CI 0.123–0.540). This study showed that SVV by NICOM and △Vpeak by echocardiography, but not CVP, reliably predicted fluid responsiveness during mechanical ventilation after ventricular septal defect repair in children.
Literatur
1.
Zurück zum Zitat Ballestero Y, López-Herce J, Urbano J et al (2011) Measurement of cardiac output in children by bioreactance. Pediatr Cardiol 32:469–472CrossRefPubMed Ballestero Y, López-Herce J, Urbano J et al (2011) Measurement of cardiac output in children by bioreactance. Pediatr Cardiol 32:469–472CrossRefPubMed
2.
Zurück zum Zitat Choi DY, Kwak HJ, Park HY, Kim YB, Choi CH, Lee JY (2010) Respiratory variation in aortic blood flow velocity as a predictor of fluid responsiveness in children after repair of ventricular septal defect. Pediatr Cardiol 31:1166–1170CrossRefPubMed Choi DY, Kwak HJ, Park HY, Kim YB, Choi CH, Lee JY (2010) Respiratory variation in aortic blood flow velocity as a predictor of fluid responsiveness in children after repair of ventricular septal defect. Pediatr Cardiol 31:1166–1170CrossRefPubMed
3.
Zurück zum Zitat Chung E, Cannesson M (2012) Using noninvasive dynamic parameters of fluid responsiveness in children: there is still much to learn. J Clin Monit Comput 26:153–155CrossRefPubMed Chung E, Cannesson M (2012) Using noninvasive dynamic parameters of fluid responsiveness in children: there is still much to learn. J Clin Monit Comput 26:153–155CrossRefPubMed
4.
Zurück zum Zitat Conway DH, Hussain OA, Gall I (2013) A comparison of noninvasive bioreactance with oesophageal Doppler estimation of stroke volume during open abdominal surgery: an observational study. Eur J Anaesthesiol 30:501–508CrossRefPubMed Conway DH, Hussain OA, Gall I (2013) A comparison of noninvasive bioreactance with oesophageal Doppler estimation of stroke volume during open abdominal surgery: an observational study. Eur J Anaesthesiol 30:501–508CrossRefPubMed
5.
Zurück zum Zitat de Souza Pereira, Neto E, Grousson S, Duflo F et al (2011) Predicting fluid responsiveness in mechanically ventilated children under general anaesthesia using dynamic parameters and transthoracic echocardiography. Br J Anaesth 106:856–864CrossRef de Souza Pereira, Neto E, Grousson S, Duflo F et al (2011) Predicting fluid responsiveness in mechanically ventilated children under general anaesthesia using dynamic parameters and transthoracic echocardiography. Br J Anaesth 106:856–864CrossRef
6.
Zurück zum Zitat Durand P, Chevret L, Essouri S, Haas V, Devictor D (2008) Respiratory variations in aortic blood flow predict fluid responsiveness in ventilated children. Intensive Care Med 34:888–894CrossRefPubMed Durand P, Chevret L, Essouri S, Haas V, Devictor D (2008) Respiratory variations in aortic blood flow predict fluid responsiveness in ventilated children. Intensive Care Med 34:888–894CrossRefPubMed
7.
Zurück zum Zitat Fagnoul D, Vincent JL, Backer DD (2012) Cardiac output measurements using the bioreactance technique in critically ill patients. Crit Care 16:460PubMedCentralCrossRefPubMed Fagnoul D, Vincent JL, Backer DD (2012) Cardiac output measurements using the bioreactance technique in critically ill patients. Crit Care 16:460PubMedCentralCrossRefPubMed
8.
Zurück zum Zitat Hanley JA, McNeil BJ (1982) The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology 143:29–36CrossRefPubMed Hanley JA, McNeil BJ (1982) The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology 143:29–36CrossRefPubMed
9.
Zurück zum Zitat Keren H, Burkhoff D, Squara P (2007) Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance. Am J Physiol Heart Circ Physiol 293:H583–H589CrossRefPubMed Keren H, Burkhoff D, Squara P (2007) Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance. Am J Physiol Heart Circ Physiol 293:H583–H589CrossRefPubMed
10.
Zurück zum Zitat Lafanechère A, Albaladejo P, Raux M et al (2006) Cardiac output measurement during infrarenal aortic surgery: echo-esophageal Doppler versus thermodilution catheter. J Cardiothorac Vasc Anesth 20:26–30CrossRefPubMed Lafanechère A, Albaladejo P, Raux M et al (2006) Cardiac output measurement during infrarenal aortic surgery: echo-esophageal Doppler versus thermodilution catheter. J Cardiothorac Vasc Anesth 20:26–30CrossRefPubMed
11.
Zurück zum Zitat Loupec T, Nanadoumgar H, Frasca D et al (2011) Pleth variability index predicts fluid responsiveness in critically ill patients. Crit Care Med 39:294–299CrossRefPubMed Loupec T, Nanadoumgar H, Frasca D et al (2011) Pleth variability index predicts fluid responsiveness in critically ill patients. Crit Care Med 39:294–299CrossRefPubMed
12.
Zurück zum Zitat Marik PE, Baram M, Vahid B (2008) Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest 134:172–178CrossRefPubMed Marik PE, Baram M, Vahid B (2008) Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest 134:172–178CrossRefPubMed
13.
Zurück zum Zitat Marik PE, Cavallazzi R, Vasu T, Hirani A (2009) Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med 37:2642–2647CrossRefPubMed Marik PE, Cavallazzi R, Vasu T, Hirani A (2009) Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med 37:2642–2647CrossRefPubMed
14.
Zurück zum Zitat Obuchowski NA, McClish DK (1997) Sample size determination for diagnostic accuracy studies involving binormal ROC curve indices. Stat Med 16:1529–1542CrossRefPubMed Obuchowski NA, McClish DK (1997) Sample size determination for diagnostic accuracy studies involving binormal ROC curve indices. Stat Med 16:1529–1542CrossRefPubMed
15.
Zurück zum Zitat Renner J, Gruenewald M, Meybohm P et al (2008) Effect of elevated PEEP on dynamic variables of fluid responsiveness in a pediatric animal model. Paediatr Anaesth 18:1170–1177PubMed Renner J, Gruenewald M, Meybohm P et al (2008) Effect of elevated PEEP on dynamic variables of fluid responsiveness in a pediatric animal model. Paediatr Anaesth 18:1170–1177PubMed
16.
Zurück zum Zitat Renner J, Cavus E, Meybohm P et al (2008) Pulse pressure variation and stroke volume variation during different loading conditions in a paediatric animal model. Acta Anaesthesiol Scand 52:374–380CrossRefPubMed Renner J, Cavus E, Meybohm P et al (2008) Pulse pressure variation and stroke volume variation during different loading conditions in a paediatric animal model. Acta Anaesthesiol Scand 52:374–380CrossRefPubMed
17.
Zurück zum Zitat Renner J, Broch O, Gruenewald M et al (2011) Noninvasive prediction of fluid responsiveness in infants using Pleth variability index. Anaesthesia 66:582–589CrossRefPubMed Renner J, Broch O, Gruenewald M et al (2011) Noninvasive prediction of fluid responsiveness in infants using Pleth variability index. Anaesthesia 66:582–589CrossRefPubMed
18.
Zurück zum Zitat Renner J, Broch O, Duetschke P et al (2012) Prediction of fluid responsiveness in infants and neonates undergoing congenital heart surgery. Br J Anaesth 108:108–115CrossRefPubMed Renner J, Broch O, Duetschke P et al (2012) Prediction of fluid responsiveness in infants and neonates undergoing congenital heart surgery. Br J Anaesth 108:108–115CrossRefPubMed
19.
Zurück zum Zitat Squara P, Denjean D, Estagnasie P, Brusset A, Dib JC, Dubois C (2007) Noninvasive cardiac output monitoring (NICOM): a clinical validation. Intensive Care Med 33:1191–1194CrossRefPubMed Squara P, Denjean D, Estagnasie P, Brusset A, Dib JC, Dubois C (2007) Noninvasive cardiac output monitoring (NICOM): a clinical validation. Intensive Care Med 33:1191–1194CrossRefPubMed
20.
Zurück zum Zitat Vistisen ST, Koefoed-Nielsen J, Larsson A (2010) Should dynamic parameters for prediction of fluid responsiveness be indexed to the tidal volume? Acta Anaesthesiol Scand 54:191–198CrossRefPubMed Vistisen ST, Koefoed-Nielsen J, Larsson A (2010) Should dynamic parameters for prediction of fluid responsiveness be indexed to the tidal volume? Acta Anaesthesiol Scand 54:191–198CrossRefPubMed
21.
Zurück zum Zitat Weisz DE, Jain A, McNamara PJ, EL-Khuffash A (2012) Noninvasive cardiac output monitoring in neonates using bioreactance: a comparison with echocardiography. Neonatology 102:61–67CrossRefPubMed Weisz DE, Jain A, McNamara PJ, EL-Khuffash A (2012) Noninvasive cardiac output monitoring in neonates using bioreactance: a comparison with echocardiography. Neonatology 102:61–67CrossRefPubMed
Metadaten
Titel
The Ability of Stroke Volume Variation Measured by a Noninvasive Cardiac Output Monitor to Predict Fluid Responsiveness in Mechanically Ventilated Children
verfasst von
Ji Yeon Lee
Ji Young Kim
Chang Hyu Choi
Hong Soon Kim
Kyung Cheon Lee
Hyun Jeong Kwak
Publikationsdatum
01.02.2014
Verlag
Springer US
Erschienen in
Pediatric Cardiology / Ausgabe 2/2014
Print ISSN: 0172-0643
Elektronische ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-013-0772-7

Weitere Artikel der Ausgabe 2/2014

Pediatric Cardiology 2/2014 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.