Free flap monitoring is a topic of interest in microsurgery around the globe. Anastomosis thrombosis continues to be associated with a flap loss rate of 5–10%. Jones described several criteria for an ideal monitor in free flap surgery. Many monitoring methods are available; however, to our knowledge, none meet all of the criteria. We developed a device that registers comparative temperatures from the flap and other adjacent skin surfaces. When the temperature changes ± > 2 °C, it automatically sends a text message to the surgeon. The aim of this study is to determine the accuracy of the device in measuring changes in temperature. We simulated a flap and adjacent tissue by heating two different plastic containers of water. To simulate the event of thrombosis, we shut down the power to one heater. In time, the water lost heat dropping the temperature. The data were registered automatically, for later analysis with Excel and R-Studio. We calculated sensitivity and specificity for detecting drops in temperature. The prevalence of events was 18.75%, with a sensitivity of 7.99%. The specificity was 100%, with a positive predictive value of 100% and a negative predictive value of 82% for detecting simulated thrombosis events. The device accurately measured the temperature changes. The high specificity and positive predictive value validated the concept. This device is easy to assemble and easy to use. It meets 6 out of 7 of the Jones criteria, making it an attractive option for microsurgeons. The main advantage is that temperature can be monitored remotely and autonomously.
Level of evidence: Level IV, risk/prognostic
Literatur
1.
Zurück zum Zitat Cervenka B, Bewley AF (2015) Free flap monitoring: a review of the recent literature. Curr Opin Otolaryngol Head Neck Surg 23(5):393–398CrossRef Cervenka B, Bewley AF (2015) Free flap monitoring: a review of the recent literature. Curr Opin Otolaryngol Head Neck Surg 23(5):393–398CrossRef
2.
Zurück zum Zitat Chae MP, Rozen WM, Whitaker IS et al (2015) Current evidence for postoperative monitoring of microvascular free flaps: a systematic review. Ann Plast Surg 74(5):621–632PubMed Chae MP, Rozen WM, Whitaker IS et al (2015) Current evidence for postoperative monitoring of microvascular free flaps: a systematic review. Ann Plast Surg 74(5):621–632PubMed
3.
Zurück zum Zitat Jones BM (1984) Monitors for the cutaneous microcirculation. Plast Reconstr Surg 73(5):843–850CrossRef Jones BM (1984) Monitors for the cutaneous microcirculation. Plast Reconstr Surg 73(5):843–850CrossRef
4.
Zurück zum Zitat Jones NF, Gupta R (2001) Postoperative monitoring of pediatric toe-to-hand transfers with differential pulse oximetry. J Hand Surg [Am] 26(3):525–529CrossRef Jones NF, Gupta R (2001) Postoperative monitoring of pediatric toe-to-hand transfers with differential pulse oximetry. J Hand Surg [Am] 26(3):525–529CrossRef
6.
Zurück zum Zitat De Parra M (2017) Remote monitoring of perforator flaps using an innovative device with an application for mobile phone : a pilot study. 1(212):37–41 De Parra M (2017) Remote monitoring of perforator flaps using an innovative device with an application for mobile phone : a pilot study. 1(212):37–41
7.
Zurück zum Zitat Khouri RK, Shaw WW (1992) Monitoring of free flaps with surface-temperature recordings: is it reliable? Plast Reconstr Surg 89(3):495-9-2CrossRef Khouri RK, Shaw WW (1992) Monitoring of free flaps with surface-temperature recordings: is it reliable? Plast Reconstr Surg 89(3):495-9-2CrossRef
8.
Zurück zum Zitat Papillion P, Wong L, Waldrop J et al (2009) Infrared surface temperature monitoring in the postoperative management of free tissue transfers. Can J Plast Surg 17(3):97–101CrossRef Papillion P, Wong L, Waldrop J et al (2009) Infrared surface temperature monitoring in the postoperative management of free tissue transfers. Can J Plast Surg 17(3):97–101CrossRef
9.
Zurück zum Zitat Lalkhen AG, McCluskey A (2008) Clinical tests: sensitivity and specificity. Contin Educ Anaesthesia, Crit Care Pain 8(6):221–223CrossRef Lalkhen AG, McCluskey A (2008) Clinical tests: sensitivity and specificity. Contin Educ Anaesthesia, Crit Care Pain 8(6):221–223CrossRef
12.
Zurück zum Zitat Fernando B, Young VL, Logan SE (1988) Miniature implantable laser Doppler probe monitoring of free tissue transfer. Ann Plast Surg 20(5):434–442CrossRef Fernando B, Young VL, Logan SE (1988) Miniature implantable laser Doppler probe monitoring of free tissue transfer. Ann Plast Surg 20(5):434–442CrossRef
13.
Zurück zum Zitat Poder TG, Fortier PH (2013) Implantable Doppler in monitoring free flaps: a cost-effectiveness analysis based on a systematic review of the literature. Eur Ann Otorhinolaryngol Head Neck Dis 130(2):79–85CrossRef Poder TG, Fortier PH (2013) Implantable Doppler in monitoring free flaps: a cost-effectiveness analysis based on a systematic review of the literature. Eur Ann Otorhinolaryngol Head Neck Dis 130(2):79–85CrossRef
14.
Zurück zum Zitat Guillemaud JP, Seikaly H, Cote D, Allen H, Harris JR (2008) The implantable Cook-Swartz Doppler probe for postoperative monitoring in head and neck free flap reconstruction. Arch Otolaryngol Head Neck Surg 134(7):729–734CrossRef Guillemaud JP, Seikaly H, Cote D, Allen H, Harris JR (2008) The implantable Cook-Swartz Doppler probe for postoperative monitoring in head and neck free flap reconstruction. Arch Otolaryngol Head Neck Surg 134(7):729–734CrossRef
15.
Zurück zum Zitat Sue GR, Kim R, Chen W, Narayan D (2014) Real-time free flap monitoring using a standard video camera: a lower cost and simpler option. Plast Reconstr Surg 133(6):905–906CrossRef Sue GR, Kim R, Chen W, Narayan D (2014) Real-time free flap monitoring using a standard video camera: a lower cost and simpler option. Plast Reconstr Surg 133(6):905–906CrossRef
16.
Zurück zum Zitat Yannuzzi LA, Rohrer KT, Tindel LJ et al (1986) Fluorescein angiography complication survey. Ophthalmology. 93(5):611–617CrossRef Yannuzzi LA, Rohrer KT, Tindel LJ et al (1986) Fluorescein angiography complication survey. Ophthalmology. 93(5):611–617CrossRef
17.
Zurück zum Zitat Yuen JC (2017) Enabling remote monitoring using free apps and smart devices for a free-flap adjunct monitor. Plast Reconstr Surg Glob Open 5(9):1–4CrossRef Yuen JC (2017) Enabling remote monitoring using free apps and smart devices for a free-flap adjunct monitor. Plast Reconstr Surg Glob Open 5(9):1–4CrossRef
18.
Zurück zum Zitat Engel H, Jung JH, Chung KT, Chia-Yu L, Pan-Yu C, Brey EM, Henry SL, Cheng MH (2011) Remote real-time monitoring of free flaps via smartphone photography and 3G wireless internet: a prospective study evidencing diagnostic accuracy. Microsurgery 31:589–595CrossRef Engel H, Jung JH, Chung KT, Chia-Yu L, Pan-Yu C, Brey EM, Henry SL, Cheng MH (2011) Remote real-time monitoring of free flaps via smartphone photography and 3G wireless internet: a prospective study evidencing diagnostic accuracy. Microsurgery 31:589–595CrossRef
Metadaten
Titel
The accuracy of an automatic free flap temperature monitor: a proof-of-concept study
verfasst von
Marco Aurelio Rendón-Medina
Marco Antonio Rendón-Pimentel
Julio Palacios-Juárez
Publikationsdatum
21.10.2019
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Plastic Surgery / Ausgabe 2/2020
Print ISSN: 0930-343X
Elektronische ISSN: 1435-0130
DOI
https://doi.org/10.1007/s00238-019-01583-1

Weitere Artikel der Ausgabe 2/2020

European Journal of Plastic Surgery 2/2020 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.