Skip to main content
Erschienen in: Clinical Research in Cardiology 11/2018

08.05.2018 | Original Paper

The best of two worlds? Pulmonary vein isolation using a novel radiofrequency ablation catheter incorporating contact force sensing technology and 56-hole porous tip irrigation

verfasst von: Tilman Maurer, Laura Rottner, Hisaki Makimoto, Bruno Reissmann, Christian-H. Heeger, Christine Lemes, Thomas Fink, Johannes Riedl, Francesco Santoro, Peter Wohlmuth, Marius Volkmer, Shibu Mathew, Andreas Metzner, Feifan Ouyang, Karl-Heinz Kuck, Christian Sohns

Erschienen in: Clinical Research in Cardiology | Ausgabe 11/2018

Einloggen, um Zugang zu erhalten

Abstract

Aims

This study aimed to evaluate feasibility and safety as well as 1-year clinical outcome of pulmonary vein isolation (PVI) using a unique radiofrequency ablation catheter (“Thermocool SmartTouch SurroundFlow”; STSF) incorporating both, contact force (CF) sensing technology and enhanced tip irrigation with 56 holes, in one device.

Methods

A total of 110 patients suffering from drug-refractory atrial fibrillation underwent wide area circumferential PVI using either the STSF ablation catheter (75 consecutive patients, study group) or a CF catheter with conventional tip irrigation (“Thermocool SmartTouch”, 35 consecutive patients, control group). For each ablation lesion, a target CF of ≥ 10–39 g and a force time integral (FTI) of > 400 g s was targeted.

Results

Acute PVI was achieved in all patients with target CF obtained in > 85% of ablation points when using either device. Mean procedure time (131.3 ± 33.7 min in the study group vs. 133.0 ± 42.0 min in the control group; p = 0.99), mean fluoroscopy time (14.0 ± 6 vs. 13.5 ± 6.6 min; p = 0.56) and total ablation time were not significantly different (1751.0 ± 394.0 vs. 1604.6 ± 287.8 s; p = 0.2). However, there was a marked reduction in total irrigation fluid delivery by 51.7% (265.52 ± 64.4 vs. 539.6 ± 118.2 ml; p < 0.01). The Kaplan–Meier estimate 12-month arrhythmia–free survival after the index procedure following a 3-month blanking period was 79.9% (95% CI 70.4%, 90.4%) for the study group and 66.7% for the control group (95% CI 50.2%, 88.5%). This finding did not reach statistical significance (p = 0.18). Major complications occurred in 2/75 patients (2.7%; one pericardial tamponade and one transient ischemic attack) in the study group and no patient in the control group (p = 18).

Conclusion

PVI using the STSF catheter is safe and effective and results in beneficial 1-year clinical outcome. The improved tip irrigation leads to a significant reduction in procedural fluid burden.
Literatur
1.
Zurück zum Zitat Kirchhof P, Benussi S, Kotecha D, Ahlsson A, Atar D, Casadei B et al (2016) 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS. Europace 18(11):1609–1678CrossRef Kirchhof P, Benussi S, Kotecha D, Ahlsson A, Atar D, Casadei B et al (2016) 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS. Europace 18(11):1609–1678CrossRef
3.
Zurück zum Zitat Makimoto H, Heeger CH, Lin T, Rillig A, Metzner A, Wissner E et al (2015) Comparison of contact force-guided procedure with non-contact force-guided procedure during left atrial mapping and pulmonary vein isolation: impact of contact force on recurrence of atrial fibrillation. Clin Res Cardiol 104(10):861–870CrossRef Makimoto H, Heeger CH, Lin T, Rillig A, Metzner A, Wissner E et al (2015) Comparison of contact force-guided procedure with non-contact force-guided procedure during left atrial mapping and pulmonary vein isolation: impact of contact force on recurrence of atrial fibrillation. Clin Res Cardiol 104(10):861–870CrossRef
4.
Zurück zum Zitat Ouyang F, Tilz R, Chun J, Schmidt B, Wissner E, Zerm T et al (2010) Long-term results of catheter ablation in paroxysmal atrial fibrillation: lessons from a 5-year follow-up. Circulation 122(23):2368–2377CrossRef Ouyang F, Tilz R, Chun J, Schmidt B, Wissner E, Zerm T et al (2010) Long-term results of catheter ablation in paroxysmal atrial fibrillation: lessons from a 5-year follow-up. Circulation 122(23):2368–2377CrossRef
7.
Zurück zum Zitat Yokoyama K, Nakagawa H, Shah DC, Lambert H, Leo G, Aeby N et al (2008) Novel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus. Circ Arrhythm Electrophysiol 1(5):354–362CrossRef Yokoyama K, Nakagawa H, Shah DC, Lambert H, Leo G, Aeby N et al (2008) Novel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus. Circ Arrhythm Electrophysiol 1(5):354–362CrossRef
8.
Zurück zum Zitat Makimoto H, Lin T, Rillig A, Metzner A, Wohlmuth P, Arya A et al (2014) In vivo contact force analysis and correlation with tissue impedance during left atrial mapping and catheter ablation of atrial fibrillation. Circ Arrhythm Electrophysiol 7(1):46–54CrossRef Makimoto H, Lin T, Rillig A, Metzner A, Wohlmuth P, Arya A et al (2014) In vivo contact force analysis and correlation with tissue impedance during left atrial mapping and catheter ablation of atrial fibrillation. Circ Arrhythm Electrophysiol 7(1):46–54CrossRef
9.
Zurück zum Zitat Reddy VY, Shah D, Kautzner J, Schmidt B, Saoudi N, Herrera C et al (2012) The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study. Heart Rhythm 9(11):1789–1795CrossRef Reddy VY, Shah D, Kautzner J, Schmidt B, Saoudi N, Herrera C et al (2012) The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study. Heart Rhythm 9(11):1789–1795CrossRef
10.
Zurück zum Zitat Stabile G, Solimene F, Calo L, Anselmino M, Castro A, Pratola C et al (2015) Catheter-tissue contact force values do not impact mid-term clinical outcome following pulmonary vein isolation in patients with paroxysmal atrial fibrillation. J Interv Card Electrophysiol 42(1):21–26CrossRef Stabile G, Solimene F, Calo L, Anselmino M, Castro A, Pratola C et al (2015) Catheter-tissue contact force values do not impact mid-term clinical outcome following pulmonary vein isolation in patients with paroxysmal atrial fibrillation. J Interv Card Electrophysiol 42(1):21–26CrossRef
11.
Zurück zum Zitat Reddy V, Pollak S, Lindsay B, McElderry H, Natale A, Kantipudi C et al (2016) Relationship between catheter stability and 12-month success after pulmonary vein isolation—a subanalysis of the SMART-AF Trial. JACC 2(6):700–702 Reddy V, Pollak S, Lindsay B, McElderry H, Natale A, Kantipudi C et al (2016) Relationship between catheter stability and 12-month success after pulmonary vein isolation—a subanalysis of the SMART-AF Trial. JACC 2(6):700–702
12.
Zurück zum Zitat Park CI, Lehrmann H, Keyl C, Weber R, Schurr P, Schiebeling-Romer J et al (2013) Enhanced efficiency of a novel porous tip irrigated RF ablation catheter for pulmonary vein isolation. J Cardiovasc Electrophysiol 24(12):1328–1335CrossRef Park CI, Lehrmann H, Keyl C, Weber R, Schurr P, Schiebeling-Romer J et al (2013) Enhanced efficiency of a novel porous tip irrigated RF ablation catheter for pulmonary vein isolation. J Cardiovasc Electrophysiol 24(12):1328–1335CrossRef
13.
Zurück zum Zitat Bertaglia E, Fassini G, Anselmino M, Stabile G, Grandinetti G, De Simone A et al (2013) Comparison of ThermoCool(R) Surround Flow catheter versus ThermoCool(R) catheter in achieving persistent electrical isolation of pulmonary veins: a pilot study. J Cardiovasc Electrophysiol 24(3):269–273CrossRef Bertaglia E, Fassini G, Anselmino M, Stabile G, Grandinetti G, De Simone A et al (2013) Comparison of ThermoCool(R) Surround Flow catheter versus ThermoCool(R) catheter in achieving persistent electrical isolation of pulmonary veins: a pilot study. J Cardiovasc Electrophysiol 24(3):269–273CrossRef
14.
Zurück zum Zitat Marrouche NF, Brachmann J, Andresen D, Siebels J, Boersma L, Jordaens L et al (2018) Catheter ablation for atrial fibrillation with heart failure. N Engl J Med 378(5):417–427CrossRef Marrouche NF, Brachmann J, Andresen D, Siebels J, Boersma L, Jordaens L et al (2018) Catheter ablation for atrial fibrillation with heart failure. N Engl J Med 378(5):417–427CrossRef
15.
Zurück zum Zitat Chinitz LA, Melby DP, Marchlinski FE, Delaughter C, Fishel RS, Monir G et al (2017) Safety and efficiency of porous-tip contact-force catheter for drug-refractory symptomatic paroxysmal atrial fibrillation ablation: results from the SMART SF trial. Europace https://doi.org/10.1093/europace/eux264 Chinitz LA, Melby DP, Marchlinski FE, Delaughter C, Fishel RS, Monir G et al (2017) Safety and efficiency of porous-tip contact-force catheter for drug-refractory symptomatic paroxysmal atrial fibrillation ablation: results from the SMART SF trial. Europace https://​doi.​org/​10.​1093/​europace/​eux264
16.
Zurück zum Zitat Stabile G, Di Donna P, Schillaci V, Di Monaco A, Iuliano A, Caponi D et al (2017) Safety and efficacy of pulmonary vein isolation using a surround flow catheter with contact force measurement capabilities: a multicenter registry. J Cardiovasc Electrophysiol 28(7):762–767CrossRef Stabile G, Di Donna P, Schillaci V, Di Monaco A, Iuliano A, Caponi D et al (2017) Safety and efficacy of pulmonary vein isolation using a surround flow catheter with contact force measurement capabilities: a multicenter registry. J Cardiovasc Electrophysiol 28(7):762–767CrossRef
17.
Zurück zum Zitat Natale A, Reddy VY, Monir G, Wilber DJ, Lindsay BD, McElderry HT et al (2014) Paroxysmal AF catheter ablation with a contact force sensing catheter: results of the prospective, multicenter SMART-AF trial. J Am Coll Cardiol 64(7):647–656CrossRef Natale A, Reddy VY, Monir G, Wilber DJ, Lindsay BD, McElderry HT et al (2014) Paroxysmal AF catheter ablation with a contact force sensing catheter: results of the prospective, multicenter SMART-AF trial. J Am Coll Cardiol 64(7):647–656CrossRef
18.
Zurück zum Zitat Das M, Loveday JJ, Wynn GJ, Gomes S, Saeed Y, Bonnett LJ et al (2016) Ablation index, a novel marker of ablation lesion quality: prediction of pulmonary vein reconnection at repeat electrophysiology study and regional differences in target values. Europace 19(5):775–783. https://doi.org/10.1093/europace/euw105 CrossRef Das M, Loveday JJ, Wynn GJ, Gomes S, Saeed Y, Bonnett LJ et al (2016) Ablation index, a novel marker of ablation lesion quality: prediction of pulmonary vein reconnection at repeat electrophysiology study and regional differences in target values. Europace 19(5):775–783. https://​doi.​org/​10.​1093/​europace/​euw105 CrossRef
19.
Zurück zum Zitat Williams S, Harrison JL, Chubb H, Bloch L, Andersen N, Dam H et al (2015) The effect of contact force in atrial radiofrequency ablation electroanatomical, cardiovascular magnetic resonance, and histological assessment in a chronic porcine model. JACC 1(5):421–431PubMed Williams S, Harrison JL, Chubb H, Bloch L, Andersen N, Dam H et al (2015) The effect of contact force in atrial radiofrequency ablation electroanatomical, cardiovascular magnetic resonance, and histological assessment in a chronic porcine model. JACC 1(5):421–431PubMed
21.
Zurück zum Zitat Oza SR, Hunter TD, Biviano AB, Dandamudi G, Herweg B, Patel AM et al (2014) Acute safety of an open-irrigated ablation catheter with 56-hole porous tip for radiofrequency ablation of paroxysmal atrial fibrillation: analysis from 2 observational registry studies. J Cardiovasc Electrophysiol 25(8):852–858CrossRef Oza SR, Hunter TD, Biviano AB, Dandamudi G, Herweg B, Patel AM et al (2014) Acute safety of an open-irrigated ablation catheter with 56-hole porous tip for radiofrequency ablation of paroxysmal atrial fibrillation: analysis from 2 observational registry studies. J Cardiovasc Electrophysiol 25(8):852–858CrossRef
22.
Zurück zum Zitat Theis C, Rostock T, Mollnau H, Sonnenschein S, Himmrich E, Kampfner D et al (2015) The incidence of audible steam pops is increased and unpredictable with the ThermoCool(R) surround flow catheter during left atrial catheter ablation: a prospective observational study. J Cardiovasc Electrophysiol. https://doi.org/10.1111/jce.12721 CrossRef Theis C, Rostock T, Mollnau H, Sonnenschein S, Himmrich E, Kampfner D et al (2015) The incidence of audible steam pops is increased and unpredictable with the ThermoCool(R) surround flow catheter during left atrial catheter ablation: a prospective observational study. J Cardiovasc Electrophysiol. https://​doi.​org/​10.​1111/​jce.​12721 CrossRef
23.
Zurück zum Zitat Quallich SG, Van Heel M, Iaizzo PA (2015) Optimal contact forces to minimize cardiac perforations before, during, and/or after radiofrequency or cryothermal ablations. Heart Rhythm 12(2):291–296CrossRef Quallich SG, Van Heel M, Iaizzo PA (2015) Optimal contact forces to minimize cardiac perforations before, during, and/or after radiofrequency or cryothermal ablations. Heart Rhythm 12(2):291–296CrossRef
25.
Zurück zum Zitat Cappato R, Calkins H, Chen SA, Davies W, Iesaka Y, Kalman J et al (2010) Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation. Circ Arrhythm Electrophysiol 3(1):32–38CrossRef Cappato R, Calkins H, Chen SA, Davies W, Iesaka Y, Kalman J et al (2010) Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation. Circ Arrhythm Electrophysiol 3(1):32–38CrossRef
Metadaten
Titel
The best of two worlds? Pulmonary vein isolation using a novel radiofrequency ablation catheter incorporating contact force sensing technology and 56-hole porous tip irrigation
verfasst von
Tilman Maurer
Laura Rottner
Hisaki Makimoto
Bruno Reissmann
Christian-H. Heeger
Christine Lemes
Thomas Fink
Johannes Riedl
Francesco Santoro
Peter Wohlmuth
Marius Volkmer
Shibu Mathew
Andreas Metzner
Feifan Ouyang
Karl-Heinz Kuck
Christian Sohns
Publikationsdatum
08.05.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Research in Cardiology / Ausgabe 11/2018
Print ISSN: 1861-0684
Elektronische ISSN: 1861-0692
DOI
https://doi.org/10.1007/s00392-018-1270-y

Weitere Artikel der Ausgabe 11/2018

Clinical Research in Cardiology 11/2018 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.