Skip to main content
Erschienen in: BMC Musculoskeletal Disorders 1/2017

Open Access 01.12.2017 | Research article

The effect of different screw-rod design on the anti-rotational torque: a biomechanical comparison of three conventional screw-rod constructs

verfasst von: Zifang Huang, Chongwen Wang, Hengwei Fan, Wenyuan Sui, Xueshi Li, Qifei Wang, Junlin Yang

Erschienen in: BMC Musculoskeletal Disorders | Ausgabe 1/2017

Abstract

Background

Screw-rod constructs have been widely used to correct spinal deformities, but the effects of different screw-rod systems on anti-rotational torque have not been determined. This study aimed to analyze the biomechanical effect of different rod-screw constructs on anti-rotational torque.

Methods

Three conventional spinal screw-rod systems (Legacy, RF-F-10 and USSII) were used to test the anti-rotational torque in the material test machine. ANOVA was performed to evaluate the anti-rotational capacity of different pedicle screws-rod constructs.

Results

The anti-rotational torque of Legacy group, RF-F-10 group and USSII group were 12.3 ± 1.9 Nm, 6.8 ± 0.4 Nm, and 3.9 ± 0.8 Nm, with a P value lower than 0.05. This results indicated that the Legacy screws-rod construct could provide a highest anti-rotation capacity, which is 68% and 210% greater than RF-F-10 screw-rod construct and USSII screw-rod respectively.

Conclusions

The anti-rotational torque may be mainly affected by screw cap and groove design. Our result showed the anti-rotational torque are: Legacy system > RF-F-10 system > USSII system, suggesting that appropriate rod-screw constructs selection in surgery may be vital for anti-rotational torque improvement and preventing derotation correction loss.
Abkürzungen
AIS
Adolescent idiopathic scoliosis
DVBD
Direct vertebral body derotation
DVR
Direct vertebral rotation
VCA
Vertebral coplanar alignment
VCM
Vertebral column manipulator

Background

Adolescent idiopathic scoliosis (AIS) is a complex three-dimensional (3D) anomaly of the spine in the coronal, sagittal, and axial planes. Rotational deformity is an important part of AIS and can affect mental health and cause cosmetic defects. Cotrel-Dubousset (CD) instrumentation and rod derotation are excellent techniques for the coronal and sagittal realignment of deformities, but it provides poor rotational improvement for a weak posteromedialization effect [1, 2]. Modern instrumentation systems with pedicle screws are able to provide both real vertebral rotational correction and rib hump correction with the use of direct vertebral rotation (DVR) [3, 4], direct vertebral body derotation (DVBD) [58], vertebral coplanar alignment (VCA) [9, 10], or vertebral column manipulator (VCM) techniques [1113]. Two recent clinical studies [14, 15] reported correction loss in the axial plane despite the use of powerful spinal screw-rod instrumentation, this phenomenon was also found in our clinical practice (Fig. 1). Biological or mechanical factors could both play roles, but to our knowledge, research on this topic is limited.
The purpose of this study was to evaluate anti-derotational torque, that is, how much tolerance a screw-rod construct has when twisting the rod in the pedicle screw groove. Here, we assessed the anti-rotational capacities of three different screw-rod constructs (Legacy, RF-F-10, and USSII, as shown in Fig. 2), which were commonly used in China.

Methods

Three testing groups included different conventional spinal screw-rod fixation systems (Legacy, Medtronic Inc., Minneapolis, MN, USA; RF-F-10 screws, Kanghui Inc., China; and USSII, Synthes Inc., West Chester, PA, USA, respectively). Each group comprised seven monoaxial pedicle screws and one round rod (Table 1). One pedicle screw was used from in group in a preliminary study (for testing the machine and adjusting the custom jig before the experiment), and the remaining six pedicle screws were tested in the experiment. Each time, one screw was tightened on the rod with constant torque. The tightening torque is created by twisting off the end cap (11–12.5 Nm) in Legacy group and tightening by 12 Nm in RF-F-10 group and USSII group. Then, part of screw thread was fixed inferiorly with methyl methacrylate to a custom jig in the material test machine (MTS 858 System Inc., Minneapolis, MN, USA), with the free end of rod (3 cm) vertically aligned with the screw axis. Finally, the rod was twisted in the pedicle screw groove at a speed of 10°/min until the torque stopped increasing, and this value was recorded (Fig. 3).
Table 1
Instrument parameters
Group
Screw-rod construct
Number of screws
Screw length and diameter (mm)
Rod diameter (mm)
A
Legacy
7
6.5 × 50
5.5
B
USSII
7
6.0 × 45
5.5
C
RF-F-10
7
6.0 × 45
5.5

Statistical analysis

Statistical comparisons were was carried out using SPSS 17 software (SPSS Inc., Chicago, IL, USA). The anti-rotational torque of three groups are presented as mean ± S.D. Analyses of variance (ANOVAs) were performed to evaluate the posthoc anti-rotational capacities of different pedicle screw-rod constructs. P-values <0.05 were considered significant.

Results

The mean anti-rotational torques of Legacy group, RF-F-10 group and USSII group were 12.3 ± 1.9 Nm, 6.8 ± 0.4 Nm, and 3.9 ± 0.8 Nm respectively, which were significantly different (P < 0.01). Posthoc testing comparing pairs of groups revealed that all were statistically different (all P < 0.01). The anti-rotational torque of the Legacy screw-rod construct was larger than that of RF-F-10, and the USSII screw-rod construct was the lowest (Fig. 4).

Discussion

Adolescent idiopathic scoliosis (AIS) is a complex 3D anomaly of the spine. Deformity in a single plane does not develop in isolation; rather, it is dependent on the co-development of curvature, translation, and rotation in other planes [1618]. Curve progression, secondary thoracic cage deformity, and rib hump are always associated with spinal rotational deformity [1922]; therefore, vertebral derotation is an important consideration when correcting AIS.
A good 3D correction for scoliosis requires both spinal instrumentation systems and corrective techniques. In the early 1980s, Cotrel-Dubousset (CD) instrumentation with rod derotation was introduced to enable 3D scoliosis correction surgery. However, recent reports suggest that rotational correction is variable (<25%) [23]. Compared to hooks, pedicle screw fixation provides better three-column fixation and 3D correction, which significantly improves the correction rates in the coronal and sagittal planes, particularly for rotational correction of the axial plane Lee et al. (2004), Gabriel et al. (2008), and Huang et al. [3, 9, 11] reported 42.5%, 56%, and 55.2% apical derotations by DVR, VCA, and VCM combined with segmental pedicle instrumentation in AIS, respectively. All three of these techniques also reduce the rib hump, in some cases eliminating the need for a thoracoplasty. This result had been substantiated in other studies [3, 10, 13]. However, Fu et al. [14] reported a recent study of vertebral rotation correction in AIS treated with four different techniques and anchors in which the patients were evaluated by the RAml method on computed tomography scan after 2 years. The authors found that rotation losses in the hook, wire, screw, and anterior groups were 20, 19.4, 17.1, and 12%, respectively. A similar result was described by Cui et al. [15], who reported a mean 2.1° correction loss of apical vertebral rotation angle 2 years after 27 AIS patients were treated with segmental pedicle screw rod constructs. However, to our knowledge, the difference in the anti-rotational capacities of different screw-rod constructs has not been previously described.
In this study, we biomechanically tested the anti-rotational torque of three different pedicle screws-rod constructs. The Legacy screw-rod construct provided the best anti-rotation capacity compared with the RF-F-10 and USSII screw-rod constructs by 68% and 210%, respectively. This suggests that the Legacy screw-rod construct can increase derotational power and better sustain potential derotational correction than the other two spinal instrumentation systems. As the same type of round rods are used in all the three, it is suspected that the anti-rotational torque differences may be caused by differences in pedicle screw design, especially in the screw head and cap part. Indeed, the cap of the Legacy screw is considered to be the main reason for its excellent anti-rotational torque.
The biomechanical testing results demonstrated that the Legacy screw-rod construct provides greater capacity for anti-rotational torque compared to the other two systems. This desirable property is likely affected by different screw cap and groove designs; thus, selecting an appropriate screw-rod system is very important for increasing the anti-rotational torque of a screw-rod construct, and derotational correction loss after AIS surgery is thereby reduced. However, the actual anti-rotational capacity of these three constructs need to be confirmed in clinical comparisons.
It is important to discuss the limitations of the current study. Only one pedicle screw with straight rod was tested in each simulation, which is both biologically and mechanically different from the situation in which multiple pedicle screws connected with curved rod during surgery. The second limitation was that polyaxial screws test was not considered in this study, although we thought it will more useful for easying the rod placement in clinical practice but not derotation. Furthermore, our findings do not clarify whether the resulting stress concentration by the cap tip on the rod in the Legacy screw-rod construct would cause fatigue failure in the rods (Fig. 5). Thus, further biomechanical evaluations of different systems’ fatigue failure and polyaxial screw’s anti-rotational effect may be needed.

Conclusions

In summary, we successfully assessed three conventional spinal screw-rod fixations for anti-rotational torque with the MTS 858 Testing System. The results showed that Legacy screws-rod construct can provide better anti-rotational capacity, possibly due to the screw cap and groove designs. The preliminary experimental results demonstrated that appropriate rod-screw construct selection in the clinic is very important for improving anti-rotational torque and preventing derotation correction loss.

Acknowledgments

No funds were received in support of this work. No benefits in any form have been or will be received from a commercial party related directly or indirectly to the subject of this manuscript.

Availability of data and materials

We had full access to all of the data in the study and take responsibility for the integrity of the data and the accuracy of the data analysis. The data is available on request from the corresponding author.
The study did not involve human and animal research.

Competing interests

The corresponding author declares the absence of any conflict of interest regarding the submitted manuscript. The funders had no role in study design, data collection and analysis, decision to publish or preparation of the manuscript.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
Literatur
1.
Zurück zum Zitat Cotrel Y, Dubousset J, Guillaumat M. New universal instrumentation in spinal surgery. Clin Orthop Relat Res. 1988;227:10–23.PubMed Cotrel Y, Dubousset J, Guillaumat M. New universal instrumentation in spinal surgery. Clin Orthop Relat Res. 1988;227:10–23.PubMed
2.
Zurück zum Zitat Krismer M, Bauer R, Sterzinger W. Scoliosis correction by Cotrel-Dubousset instrumentation. The effect of derotation and three-dimensional correction. Spine. 1992;17:S263–9.CrossRefPubMed Krismer M, Bauer R, Sterzinger W. Scoliosis correction by Cotrel-Dubousset instrumentation. The effect of derotation and three-dimensional correction. Spine. 1992;17:S263–9.CrossRefPubMed
3.
Zurück zum Zitat Lee SM, Suk SI, Chung ER. Direct vertebral rotation: a new technique of three-dimensional deformity correction with segmental pedicle screw fixation in adolescent idiopathic scoliosis. Spine. 2004;29:343–9.CrossRefPubMed Lee SM, Suk SI, Chung ER. Direct vertebral rotation: a new technique of three-dimensional deformity correction with segmental pedicle screw fixation in adolescent idiopathic scoliosis. Spine. 2004;29:343–9.CrossRefPubMed
4.
Zurück zum Zitat Mladenov KV, Vaeterlein C, Stuecker R. Selective posterior thoracic fusion by means of direct vertebral derotation in adolescent idiopathic scoliosis: effects on the sagittal alignment. Eur Spine J. 2011;20:1114–7.CrossRefPubMedPubMedCentral Mladenov KV, Vaeterlein C, Stuecker R. Selective posterior thoracic fusion by means of direct vertebral derotation in adolescent idiopathic scoliosis: effects on the sagittal alignment. Eur Spine J. 2011;20:1114–7.CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Hwang SW, Samdani AF, Gressot LV. Effect of direct vertebral body derotation on the sagittal profile in adolescent idiopathic scoliosis. Eur Spine J. 2012;12:31–9.CrossRef Hwang SW, Samdani AF, Gressot LV. Effect of direct vertebral body derotation on the sagittal profile in adolescent idiopathic scoliosis. Eur Spine J. 2012;12:31–9.CrossRef
7.
Zurück zum Zitat Hwang SW, Dubaz OM, Ames R, et al. The impact of direct vertebal body derotation on the lumbar prominence in Lenke Type 5C curves. J Neurosurg Spine. 2012;17(4):308–13.CrossRefPubMed Hwang SW, Dubaz OM, Ames R, et al. The impact of direct vertebal body derotation on the lumbar prominence in Lenke Type 5C curves. J Neurosurg Spine. 2012;17(4):308–13.CrossRefPubMed
8.
Zurück zum Zitat Hwang SW, Samdani AF, Lonner B, et al. Impact of direct vertebral body derotation on rib prominence: are preoperative factors predictive of changes in rib prominence? Spine (Phila Pa 1976). 2012;37(2):E86–9.CrossRef Hwang SW, Samdani AF, Lonner B, et al. Impact of direct vertebral body derotation on rib prominence: are preoperative factors predictive of changes in rib prominence? Spine (Phila Pa 1976). 2012;37(2):E86–9.CrossRef
9.
Zurück zum Zitat Vallespir GP, Flores JB, Trigueros IS. Vertebral coplanar alignment: a standardized technique for three dimensional correction in scoliosis surgery: technical description and preliminary results in Lenke type 1 curves. Spine. 2008;33:1588–97.CrossRefPubMed Vallespir GP, Flores JB, Trigueros IS. Vertebral coplanar alignment: a standardized technique for three dimensional correction in scoliosis surgery: technical description and preliminary results in Lenke type 1 curves. Spine. 2008;33:1588–97.CrossRefPubMed
10.
Zurück zum Zitat Qiu Y, Zhu F, Wang B. Comparison of surgical outcomes of Lenke type 1 idiopathic scoliosis: vertebral coplanar alignment versus derotation technique. J Spinal Disord Tech. 2011;12:492–9. Qiu Y, Zhu F, Wang B. Comparison of surgical outcomes of Lenke type 1 idiopathic scoliosis: vertebral coplanar alignment versus derotation technique. J Spinal Disord Tech. 2011;12:492–9.
11.
Zurück zum Zitat Huang Z, Wang Q, Yang J, et al. Vertebral derotation by vertebral column manipulator improves postoperative radiographs outcomes of Lenke 5C patients for follow up minimum 2 year. J Spinal Disord Tech. 2014;4. [Epub ahead of print]. Huang Z, Wang Q, Yang J, et al. Vertebral derotation by vertebral column manipulator improves postoperative radiographs outcomes of Lenke 5C patients for follow up minimum 2 year. J Spinal Disord Tech. 2014;4. [Epub ahead of print].
12.
Zurück zum Zitat Yang J, Huang Z, Grevitt MP, et al. Double-curve synchronous derotation with convex correction: a new corrective technique for adolescent idiopathic scoliosis with double curves. J Spinal Disord Tech. 2014;27(1):E32–6.CrossRefPubMed Yang J, Huang Z, Grevitt MP, et al. Double-curve synchronous derotation with convex correction: a new corrective technique for adolescent idiopathic scoliosis with double curves. J Spinal Disord Tech. 2014;27(1):E32–6.CrossRefPubMed
13.
Zurück zum Zitat Sun L, Song Y, Liu L, et al. Bilateral apical vertebal derotation technique by vertebral column manipulation compare with vertebral coplanar alignment technique in the correction of Lenke I type idiopathic scoliosis. BMC Musculoskelet Disord. 2013;14:175.CrossRefPubMedPubMedCentral Sun L, Song Y, Liu L, et al. Bilateral apical vertebal derotation technique by vertebral column manipulation compare with vertebral coplanar alignment technique in the correction of Lenke I type idiopathic scoliosis. BMC Musculoskelet Disord. 2013;14:175.CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat Fu G, Kawakami N, Goto M. Comparison of vertebral rotation corrected by different techniques and anchors in surgical treatment of adolescent thoracic idiopathic scoliosis. J Spinal Disord Tech. 2009;22:182–9.CrossRefPubMed Fu G, Kawakami N, Goto M. Comparison of vertebral rotation corrected by different techniques and anchors in surgical treatment of adolescent thoracic idiopathic scoliosis. J Spinal Disord Tech. 2009;22:182–9.CrossRefPubMed
15.
Zurück zum Zitat Cui G, Watanabe K, Nishiwaki Y, et al. Loss of apical vertebral derotation in adolescent idiopathic scoliosis: 2-year follow-up using multi-planar reconstruction computed tomography. Eur Spine J. 2012;21(6):1111–20.CrossRefPubMedPubMedCentral Cui G, Watanabe K, Nishiwaki Y, et al. Loss of apical vertebral derotation in adolescent idiopathic scoliosis: 2-year follow-up using multi-planar reconstruction computed tomography. Eur Spine J. 2012;21(6):1111–20.CrossRefPubMedPubMedCentral
16.
Zurück zum Zitat Cholewicki J, Crisco JJ 3rd, Oxland TR. Effects of posture and structure on three-dimensional coupled rotations in the lumbar spine. Spine. 1996;21:2421–8.CrossRefPubMed Cholewicki J, Crisco JJ 3rd, Oxland TR. Effects of posture and structure on three-dimensional coupled rotations in the lumbar spine. Spine. 1996;21:2421–8.CrossRefPubMed
17.
Zurück zum Zitat Perdriolle R, Vidal J. Morphology of scoliosis: three-dimensional evolution. Orthopedics. 1987;10:909–15.PubMed Perdriolle R, Vidal J. Morphology of scoliosis: three-dimensional evolution. Orthopedics. 1987;10:909–15.PubMed
18.
19.
Zurück zum Zitat Weinstein SL, Zavala DC, Ponseti IV. Idiopathic scoliosis: long-term follow-up and prognosis in untreated patients. J Bone Joint Surg Am. 1981;63:702–12.CrossRefPubMed Weinstein SL, Zavala DC, Ponseti IV. Idiopathic scoliosis: long-term follow-up and prognosis in untreated patients. J Bone Joint Surg Am. 1981;63:702–12.CrossRefPubMed
20.
Zurück zum Zitat Aronsson DD, Stokes IA, Ronchetti PJ. Surgical correction of vertebral axial rotation in adolescent idiopathic scoliosis: prediction by lateral bending films. J Spinal Disord. 1996;9:214–9.CrossRefPubMed Aronsson DD, Stokes IA, Ronchetti PJ. Surgical correction of vertebral axial rotation in adolescent idiopathic scoliosis: prediction by lateral bending films. J Spinal Disord. 1996;9:214–9.CrossRefPubMed
21.
Zurück zum Zitat Behensky H, Cole AA, Freeman BJ. Fixed lumbar apical vertebral rotation predicts spinal decompensation in Lenke type 3C adolescent idiopathic scoliosis after selective posterior thoracic correction and fusion. Eur Spine J. 2007;16:1570–8.CrossRefPubMedPubMedCentral Behensky H, Cole AA, Freeman BJ. Fixed lumbar apical vertebral rotation predicts spinal decompensation in Lenke type 3C adolescent idiopathic scoliosis after selective posterior thoracic correction and fusion. Eur Spine J. 2007;16:1570–8.CrossRefPubMedPubMedCentral
22.
Zurück zum Zitat Perdriolle R, Vidal J. Thoracic idiopathic scoliosis curve evaluation and prognosis. Spine. 1985;10:785–91.CrossRefPubMed Perdriolle R, Vidal J. Thoracic idiopathic scoliosis curve evaluation and prognosis. Spine. 1985;10:785–91.CrossRefPubMed
23.
Zurück zum Zitat Steib JP, Dumas R, Mitton D. Surgical correction of scoliosis by in situ contouring: a detorsion analysis. Spine. 2004;29:193–9.CrossRefPubMed Steib JP, Dumas R, Mitton D. Surgical correction of scoliosis by in situ contouring: a detorsion analysis. Spine. 2004;29:193–9.CrossRefPubMed
Metadaten
Titel
The effect of different screw-rod design on the anti-rotational torque: a biomechanical comparison of three conventional screw-rod constructs
verfasst von
Zifang Huang
Chongwen Wang
Hengwei Fan
Wenyuan Sui
Xueshi Li
Qifei Wang
Junlin Yang
Publikationsdatum
01.12.2017
Verlag
BioMed Central
Erschienen in
BMC Musculoskeletal Disorders / Ausgabe 1/2017
Elektronische ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-017-1683-1

Weitere Artikel der Ausgabe 1/2017

BMC Musculoskeletal Disorders 1/2017 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.