The effect of rotator cuff malreduction on tendon tension: an evaluation of a custom-made digital tensiometer clamp

Zeitschrift:
Archives of Orthopaedic and Trauma Surgery > Ausgabe 2/2018
Autoren:
Marc-Frederic Pastor, Manuel Kraemer, Michael Schwarze, Christof Hurschler, Tomas Smith, Mathias Wellmann

Abstract

Introduction

Rotator cuff tears are common and good-to-excellent clinical outcome is reported after subsequent repair. However, the retear rate of rotator cuff repairs has been shown to be as high as 20%. The reasons for retear seem to be multifactorial, mainly comprised by mechanical and biological aspects. Regarding mechanical causes, the role of the tendon tension and malreduction is so far unknown. First, we hypothesized that the tendon tension depends on the technique of tendon reposition and that malreduction of the tendon results in an increased tendon tension. Second, we aimed to demonstrate the inter- and intraobserver reliability of a novel custom-made digital tensiometer clamp.

Materials and methods

A tendon defect of posterosuperior rotator cuff (reverse L-shaped) was simulated in seven cadaveric human shoulder specimens. By use of a custom-made tensiometer clamp, the supraspinatus tendon was reduced by pulling it in (1) an anterolateral direction (anatomical reduction) and (2) in a straight lateral direction (malreduction) until the footprint was completely covered. The reduction procedure was consecutively repeated to evaluate the inter- and intraobserver reliability.

Results

The mean traction forces for anatomical reduction and malreduction were 16.02 N (SD 8.06) and 19.52 N (SD 9.95), respectively. The difference between the two groups was statistically significant (p = 0.028). The interobserver reliability showed a correlation of r = 0.757 [95% confidence interval (CI) 0.092–0.955]. The intraobserver reliability of the three surgeons was observed to be between r = 0.905 and 0.986.

Conclusions

The malreduction of the rotator cuff has a significant influence on the tendon tension and may therefore affect the healing rate of the tendon after the repair, so that a tension-balanced repair could improve the clinical results. Furthermore, the application of a novel custom-made tensiometer clamp showed good interobserver and excellent intraobserver reliabilities.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de. Zusätzlich können Sie eine Zeitschrift Ihrer Wahl in gedruckter Form beziehen – ohne Aufpreis.

Weitere Produktempfehlungen anzeigen
Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 2/2018

Archives of Orthopaedic and Trauma Surgery 2/2018 Zur Ausgabe
  1. Sie können e.Med Orthopädie & Unfallchirurgie 14 Tage kostenlos testen (keine Print-Zeitschrift enthalten). Der Test läuft automatisch und formlos aus. Es kann nur einmal getestet werden.

Neu im Fachgebiet Orthopädie und Unfallchirurgie

Mail Icon II Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Orthopädie und Unfallchirurgie und bleiben Sie gut informiert – ganz bequem per eMail.

Bildnachweise