The effect of strut thickness on shear stress distribution in a preclinical model

verfasst von: Erhan Tenekecioglu, Ryo Torii, Christos Bourantas, Yosuke Miyazaki, Carlos Collet, Rasha Al-Lameé, Kadem Al-Lameé, Yoshinobu Onuma, Patrick W. Serruys

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 11/2017

download
DOWNLOAD
print
DRUCKEN
insite
SUCHEN
Hinweise
Erhan Tenekecioglu and Ryo Torii have contributed equally to this work.

Case report

In-vitro and in-silico studies have shown that stent design and struts thickness introduce significant changes in local hemodynamics. The protruding struts disrupt the laminar flow with the impacts of strut thickness and strut shape. Angiographic and optical coherence tomography (OCT) data were implemented to reconstruct three-dimensional (3D) geometry of the right coronary artery (RCA) of a healthy mini-swine implanted with 3.0 × 14 mm ArterioSorb (Arterius, UK) with 95 micron (µm) strut thickness in proximal segment (final post-dilatation mean lumen diameter: 2.78 mm) and 3.0 × 14 mm ArterioSorb with 120 µm strut thickness in mid-segment (final post-dilatation mean lumen diameter: 2.80 mm) of the vessel.
During computational fluid dynamic (CFD) study, endothelial shear stress (ESS) was quantified in the scaffolded segment around the circumference of the lumen per 5°-subunit and along the axial direction per 200 µm interval [1]. Median ESS was lower in the distal scaffold (ArterioSorb-120 µm) [1.17 (0.78–1.55) Pa] than in the proximal scaffold (ArterioSorb-95 µm) [1.25 (0.92–1.88) Pa] in Newtonian steady flow simulation (p < 0.0001). 37.4% of the scaffolded surface in ArterioSorb-120 µm and 32.6% in ArterioSorb-95 µm was exposed to a low (<1 Pa) athero-promoting ESS (Fig. 1). The p-value is based on 5°-subunit (n = 15,984) analysis using mixed effects regression model.
The difference in ESS may stem from strut thickness, luminal diameter, vessel curvature and flow boundary conditions. In the present case, after excluding other factors, lower ESS in ArterioSorb-120 µm is presumably ascribed to the thicker struts (Fig. 1). However, even in ArterioSorb-120 µm, the shear stress was not as low as reported in Absorb BVS (Median ESS:0.57 Pa) [2] which should be attributed to the thinner struts of ArterioSorb.

Compliance with ethical standards

Disclosures

E. Tenekecioglu has a research grant from TUBITAK (The Scientific Council of Turkey). P.W. Serruys is a member of the International Advisory Board of Abbott Vascular. Y. Onuma is a member of the International Advisory Board of Abbott Vascular.

Research involving human and animal participants

All applicable international and institutional guidelines for the care and use of animals were followed.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Innere Medizin

Kombi-Abonnement

Mit e.Med Innere Medizin erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes Innere Medizin, den Premium-Inhalten der internistischen Fachzeitschriften, inklusive einer gedruckten internistischen Zeitschrift Ihrer Wahl.

Literatur
1.
Zurück zum Zitat Tenekecioglu E, Torii R, Bourantas C et al (2016) Preclinical assessment of the endothelial shear stress in porcine-based models following implantation of two different bioresorbable scaffolds: effect of scaffold design on the local haemodynamic micro-environment. EuroIntervention 12(10):1296CrossRefPubMed Tenekecioglu E, Torii R, Bourantas C et al (2016) Preclinical assessment of the endothelial shear stress in porcine-based models following implantation of two different bioresorbable scaffolds: effect of scaffold design on the local haemodynamic micro-environment. EuroIntervention 12(10):1296CrossRefPubMed
2.
Zurück zum Zitat Tenekecioglu E, Torii R, Bourantas C et al (2017) Assessment of the hemodynamic characteristics of Absorb BVS in a porcine coronary artery model. Int J Cardiol 227:467–473CrossRefPubMed Tenekecioglu E, Torii R, Bourantas C et al (2017) Assessment of the hemodynamic characteristics of Absorb BVS in a porcine coronary artery model. Int J Cardiol 227:467–473CrossRefPubMed
Metadaten
Titel
The effect of strut thickness on shear stress distribution in a preclinical model
verfasst von
Erhan Tenekecioglu
Ryo Torii
Christos Bourantas
Yosuke Miyazaki
Carlos Collet
Rasha Al-Lameé
Kadem Al-Lameé
Yoshinobu Onuma
Patrick W. Serruys
Publikationsdatum
31.05.2017
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 11/2017
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-017-1173-4

Weitere Artikel der Ausgabe 11/2017

The International Journal of Cardiovascular Imaging 11/2017 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.