Skip to main content
Erschienen in: European Spine Journal 3/2012

01.03.2012 | Original Article

The effect of the X-Stop implantation on intervertebral foramen, segmental spinal canal length and disc space in elderly patients with lumbar spinal stenosis

verfasst von: Zongmiao Wan, Shaobai Wang, Michal Kozanek, Qun Xia, Frederick L. Mansfield, Guohua Lü, Kirkham B. Wood, Guoan Li

Erschienen in: European Spine Journal | Ausgabe 3/2012

Einloggen, um Zugang zu erhalten

Abstract

Objectives

To evaluate the biomechanical effect of the X-Stop device on the intervertebral foramen (IVF) and segmental spinal canal length (SSCL), as well as the intervertebral disc space at the implanted and the adjacent segments in patients with lumbar spinal stenosis (LSS).

Materials and methods

Eight elderly patients with LSS, scheduled for X-stop implantation, were CT or MRI scanned to construct 3D vertebral models (L2–S1). Before and after the surgery, each patient was also imaged using a dual-fluoroscopic image system during weight-bearing standing and maximum extension–flexion. The positions of the vertebrae were then determined using an established 2D–3D model matching method.

Results

The data revealed that the postoperative IVF area was significantly increased by 32.9% (or 32 mm2) (p < 0.05) and the IVF width was increased by 24.4% (or 1.1 mm, p = 0.06) during extension, but with minimal change in standing and flexion. The IVF heights were significantly (p < 0.05) increased at standing by 1.2 mm and extension by 1.8 mm, but not at flexion. The SSCL were significantly (p < 0.05) increased at extension by 1.2 mm, but not at standing and flexion. Anterior disc space of the implanted level was significantly decreased from 8.0 to 6.6 mm during standing.

Conclusion

The X-Stop implantation efficiently enlarged the IVF area in the elderly patients with LSS at the operated level with little biomechanical effect immediately on the superior and inferior adjacent levels. However, it reduced the anterior disc space at the implanted level.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Verbiest H (1954) A radicular syndrome from developmental narrowing of the lumbar vertebral canal. J Bone Joint Surg Br 36-B:230–237PubMed Verbiest H (1954) A radicular syndrome from developmental narrowing of the lumbar vertebral canal. J Bone Joint Surg Br 36-B:230–237PubMed
2.
Zurück zum Zitat Inufusa A, An HS, Lim TH, Hasegawa T, Haughton VM, Nowicki BH (1996) Anatomic changes of the spinal canal and intervertebral foramen associated with flexion–extension movement. Spine 21:2412–2420 (Phila Pa 1976)PubMedCrossRef Inufusa A, An HS, Lim TH, Hasegawa T, Haughton VM, Nowicki BH (1996) Anatomic changes of the spinal canal and intervertebral foramen associated with flexion–extension movement. Spine 21:2412–2420 (Phila Pa 1976)PubMedCrossRef
5.
Zurück zum Zitat Juricek M, Rehak L, Horvath J, Tisovsky P (2010) Quality of life after elective lumbar spinal fusions. Bratisl Lek Listy 111:290–295PubMed Juricek M, Rehak L, Horvath J, Tisovsky P (2010) Quality of life after elective lumbar spinal fusions. Bratisl Lek Listy 111:290–295PubMed
6.
Zurück zum Zitat Lee J, Hida K, Seki T, Iwasaki Y, Minoru A (2004) An interspinous process distractor (X STOP) for lumbar spinal stenosis in elderly patients: preliminary experiences in 10 consecutive cases. J Spinal Disord Tech 17:72–77 00024720-200402000-00013[pii] (discussion 78)PubMedCrossRef Lee J, Hida K, Seki T, Iwasaki Y, Minoru A (2004) An interspinous process distractor (X STOP) for lumbar spinal stenosis in elderly patients: preliminary experiences in 10 consecutive cases. J Spinal Disord Tech 17:72–77 00024720-200402000-00013[pii] (discussion 78)PubMedCrossRef
9.
Zurück zum Zitat Zucherman JF, Hsu KY, Hartjen CA, Mehalic TF, Implicito DA, Martin MJ, Johnson DR 2nd, Skidmore GA, Vessa PP, Dwyer JW, Puccio ST, Cauthen JC, Ozuna RM (2005) A multicenter, prospective, randomized trial evaluating the X STOP interspinous process decompression system for the treatment of neurogenic intermittent claudication: two-year follow-up results. Spine 30:1351–1358 00007632-200506150-00003[pii] (Phila Pa 1976)PubMedCrossRef Zucherman JF, Hsu KY, Hartjen CA, Mehalic TF, Implicito DA, Martin MJ, Johnson DR 2nd, Skidmore GA, Vessa PP, Dwyer JW, Puccio ST, Cauthen JC, Ozuna RM (2005) A multicenter, prospective, randomized trial evaluating the X STOP interspinous process decompression system for the treatment of neurogenic intermittent claudication: two-year follow-up results. Spine 30:1351–1358 00007632-200506150-00003[pii] (Phila Pa 1976)PubMedCrossRef
11.
Zurück zum Zitat Kuchta J, Sobottke R, Eysel P, Simons P (2009) Two-year results of interspinous spacer (X-Stop) implantation in 175 patients with neurologic intermittent claudication due to lumbar spinal stenosis. Eur Spine J 18:823–829. doi:10.1007/s00586-009-0967-z PubMedCrossRef Kuchta J, Sobottke R, Eysel P, Simons P (2009) Two-year results of interspinous spacer (X-Stop) implantation in 175 patients with neurologic intermittent claudication due to lumbar spinal stenosis. Eur Spine J 18:823–829. doi:10.​1007/​s00586-009-0967-z PubMedCrossRef
12.
Zurück zum Zitat Richards JC, Majumdar S, Lindsey DP, Beaupre GS, Yerby SA (2005) The treatment mechanism of an interspinous process implant for lumbar neurogenic intermittent claudication. Spine 30:744–749 00007632-200504010-00006[pii] (Phila Pa 1976)PubMedCrossRef Richards JC, Majumdar S, Lindsey DP, Beaupre GS, Yerby SA (2005) The treatment mechanism of an interspinous process implant for lumbar neurogenic intermittent claudication. Spine 30:744–749 00007632-200504010-00006[pii] (Phila Pa 1976)PubMedCrossRef
13.
Zurück zum Zitat Nandakumar A, Clark NA, Peehal JP, Bilolikar N, Wardlaw D, Smith FW (2010) The increase in dural sac area is maintained at 2 years after X-stop implantation for the treatment of spinal stenosis with no significant alteration in lumbar spine range of movement. Spine J 10:762–768. doi:10.1016/j.spinee.2010.06.007 PubMedCrossRef Nandakumar A, Clark NA, Peehal JP, Bilolikar N, Wardlaw D, Smith FW (2010) The increase in dural sac area is maintained at 2 years after X-stop implantation for the treatment of spinal stenosis with no significant alteration in lumbar spine range of movement. Spine J 10:762–768. doi:10.​1016/​j.​spinee.​2010.​06.​007 PubMedCrossRef
15.
Zurück zum Zitat Wan Z, Wang S, Kozanek M, Passias PG, Xia Q, Mansfield FL, Wood KB, Li G (2011) Effect of X-Stop implantation on vertebral and interspinous process motion. In: 57th Annual Meeting of the Orthopaedic Research Soceity Long Beach, California Wan Z, Wang S, Kozanek M, Passias PG, Xia Q, Mansfield FL, Wood KB, Li G (2011) Effect of X-Stop implantation on vertebral and interspinous process motion. In: 57th Annual Meeting of the Orthopaedic Research Soceity Long Beach, California
18.
Zurück zum Zitat Fujiwara A, An HS, Lim TH, Haughton VM (2001) Morphologic changes in the lumbar intervertebral foramen due to flexion-extension, lateral bending, and axial rotation: an in vitro anatomic and biomechanical study. Spine 26:876–882 (Phila Pa 1976)PubMedCrossRef Fujiwara A, An HS, Lim TH, Haughton VM (2001) Morphologic changes in the lumbar intervertebral foramen due to flexion-extension, lateral bending, and axial rotation: an in vitro anatomic and biomechanical study. Spine 26:876–882 (Phila Pa 1976)PubMedCrossRef
19.
Zurück zum Zitat Ge Y, Maurer CR, Fitzpatrick JM (1996) Surface-based 3D image registration using the iterative closest point algorithm with a closest-point transform. Med Imaging Image Process 2710:358–367. doi:10.1117/12.237938 Ge Y, Maurer CR, Fitzpatrick JM (1996) Surface-based 3D image registration using the iterative closest point algorithm with a closest-point transform. Med Imaging Image Process 2710:358–367. doi:10.​1117/​12.​237938
21.
Zurück zum Zitat Schlegel JD, Champine J, Taylor MS, Watson JT, Champine M, Schleusener RL, Savory KM (1994) The role of distraction in improving the space available in the lumbar stenotic canal and foramen. Spine 19:2041–2047 (Phila Pa 1976)PubMedCrossRef Schlegel JD, Champine J, Taylor MS, Watson JT, Champine M, Schleusener RL, Savory KM (1994) The role of distraction in improving the space available in the lumbar stenotic canal and foramen. Spine 19:2041–2047 (Phila Pa 1976)PubMedCrossRef
22.
Zurück zum Zitat Bayley JC, Yoo JU, Kruger DM, Schlegel J (1995) The role of distraction in improving the space available for the cord in cervical spondylosis. Spine 20:771–775 (Phila Pa 1976)PubMedCrossRef Bayley JC, Yoo JU, Kruger DM, Schlegel J (1995) The role of distraction in improving the space available for the cord in cervical spondylosis. Spine 20:771–775 (Phila Pa 1976)PubMedCrossRef
23.
Zurück zum Zitat Siddiqui M, Nicol M, Karadimas E, Smith F, Wardlaw D (2005) The positional magnetic resonance imaging changes in the lumbar spine following insertion of a novel interspinous process distraction device. Spine 30:2677–2682 00007632-200512010-00013[pii] (Phila Pa 1976)PubMedCrossRef Siddiqui M, Nicol M, Karadimas E, Smith F, Wardlaw D (2005) The positional magnetic resonance imaging changes in the lumbar spine following insertion of a novel interspinous process distraction device. Spine 30:2677–2682 00007632-200512010-00013[pii] (Phila Pa 1976)PubMedCrossRef
Metadaten
Titel
The effect of the X-Stop implantation on intervertebral foramen, segmental spinal canal length and disc space in elderly patients with lumbar spinal stenosis
verfasst von
Zongmiao Wan
Shaobai Wang
Michal Kozanek
Qun Xia
Frederick L. Mansfield
Guohua Lü
Kirkham B. Wood
Guoan Li
Publikationsdatum
01.03.2012
Verlag
Springer-Verlag
Erschienen in
European Spine Journal / Ausgabe 3/2012
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-011-2021-1

Weitere Artikel der Ausgabe 3/2012

European Spine Journal 3/2012 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.