Abstract

Objectives

Conventional methods for orthodontic metal brackets debonding produce forces that are high enough to cause enamel scratches, fracture, and patient’s discomfort. The aim of this study was to assess the effectiveness of Er,Cr:YSGG laser in debonding metal orthodontic brackets in comparison to conventional debonding method.

Materials and methods

Stainless steel orthodontic brackets were bonded on the buccal surface of 30 freshly extracted human premolars teeth which were divided into two groups: (1) control group; conventional bracket debonding, using debonding plier and (2) test group; Er,Cr:YSGG laser (2.78 μm, 6 W, 20 Hz, 60 μs pulse duration) were used for laser debonding. Adhesive Remnants Index (ARI) was assessed using scanning electron microscope images and statistically compared between both groups. The time needed for debonding in both groups was also recorded and statistically compared.

Results

The results of this study showed that in test group, the used laser irradiation parameters effectively debonded all metal brackets. Mann-Whitney U test showed lower ARI scores in the test irradiated group when compared to the control group. The results also showed that higher time values were needed for debonding of metal brackets in test group when compared to the control group.

Conclusion

The Er,Cr:YSGG laser can be used for effective debonding of stainless steel orthodontic brackets.
Literatur
6.
Zurück zum Zitat Pickett K, Sadowsky L, Jacobson A, Lacefield W (2001) Orthodontic in vivo bond strength: comparison with in vitro study. Angle Orthod. 77:141–148 Pickett K, Sadowsky L, Jacobson A, Lacefield W (2001) Orthodontic in vivo bond strength: comparison with in vitro study. Angle Orthod. 77:141–148
11.
Zurück zum Zitat Shafiee HA et al (2015) Enamel surface roughness after orthodontic bracket debonding and composite resin removal by two types of burs. Journal of Dental School 33(3):210–219 Shafiee HA et al (2015) Enamel surface roughness after orthodontic bracket debonding and composite resin removal by two types of burs. Journal of Dental School 33(3):210–219
14.
Zurück zum Zitat Kotana T (1997) Stresses developed during clinical debonding of stainless steel orthodontic brackets. Angle Orthod. 67(1):39–46 Kotana T (1997) Stresses developed during clinical debonding of stainless steel orthodontic brackets. Angle Orthod. 67(1):39–46
19.
Zurück zum Zitat Khan H, Chaudry A, Ahmad F, Warriach F (2015) Comparison of debonding time and pain between three different debonding techniques for stainless steel brackets. Pak Oral amd Dent J 35(1):79–82 Khan H, Chaudry A, Ahmad F, Warriach F (2015) Comparison of debonding time and pain between three different debonding techniques for stainless steel brackets. Pak Oral amd Dent J 35(1):79–82
Metadaten
Titel
The effect of using Er,Cr:YSGG laser in debonding stainless steel orthodontic brackets: an in vitro study
verfasst von
Youssef Sedky
Norbert Gutknecht
Publikationsdatum
18.01.2018
Verlag
Springer International Publishing
Erschienen in
Lasers in Dental Science / Ausgabe 1/2018
Elektronische ISSN: 2367-2587
DOI
https://doi.org/10.1007/s41547-017-0012-1

Weitere Artikel der Ausgabe 1/2018

Lasers in Dental Science 1/2018 Zur Ausgabe

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.