Skip to main content
Erschienen in: BMC Oral Health 1/2017

Open Access 01.12.2017 | Research article

The effectiveness of vibrational stimulus to accelerate orthodontic tooth movement: a systematic review

verfasst von: Dian Jing, Jiani Xiao, Xiaobing Li, Yu Li, Zhihe Zhao

Erschienen in: BMC Oral Health | Ausgabe 1/2017

Abstract

Background

In recent years, it has been a hot research topic to accelerate orthodontic tooth movement (OTM) through vibration. This review was therefore aimed to systematically evaluate the available evidences on the efficacy of vibrational stimulus to accelerate OTM.

Methods

Randomized controlled trials and controlled clinical trials that evaluated the efficacy of vibration on OTM acceleration were searched through electronic and manual search. Two review authors independently conducted the study inclusion, quality assessment and data extraction. The quality of synthesized evidence was assessed according to GRADE system.

Results

Eight clinical trials were included in this systematic review. Four studies found that vibration did not enhance the rate of OTM during alignment phase. Two studies revealed that the use of vibratory stimulation accelerated canine retraction. No deleterious effects including pain perceptions and root resorptions were reported.

Conclusions

Within the limitations of this review, weak evidence indicates that vibrational stimulus is effective for accelerating canine retraction but not for alignment. The effects of vibration on pain intensity and root resorption during orthodontic treatment are inconclusive. Future high-quality clinical trials are needed before warranting recommendations to clinical application.
Abkürzungen
CCT
Controlled clinical trials
CENTRAL
Cochrane Central Register of Controlled Trials
GRADE
Grading of Recommendations Assessment, Development and Evaluation
MeSH
Medical Subject Headings
OTM
Orthodontic tooth movement
PRISMA
Preferred Reporting Items for Systematic Reviews and Meta-analyses
RCT
Randomized controlled trials
SIGLE
System for Information on Grey Literature in Europe
VAS
Visual analogue scale

Background

The length of orthodontic treatment, which normally ranges from 24 to 36 months, is one of the main concerns to patients [1, 2]. The prolonged treatment duration could reduce the compliance of patients, and cause numerous adverse effects including white spot lesions, periodontal diseases and external root resorptions [3, 4]. Therefore, approaches to speed up orthodontic tooth movement (OTM) and the resulting reduction of treatment duration are always desirable to orthodontists and patients.
In recent years, numerous surgical and nonsurgical adjunctive procedures to accelerate OTM have been introduced [57]. Surgical techniques like corticotomy have been reported to facilitate tooth movement in short term via inducing regional acceleratory phenomenon [5, 7]. However, the invasiveness and postoperative discomfort make patients less receptive to these techniques and restrict the routine application in clinics [8]. Several nonsurgical adjuncts including laser therapy, electric current, pulsed electromagnetic fields and photobiomodulation are suggested to promote tooth movement [911]. However, the use of these approaches is also limited since the necessity of performance by disciplined clinicians and low quality of evidence [5, 9].
Among the nonsurgical interventions, vibrational stimulus is promising and has already been commercial since portability, convenience and invasiveness. The potency of applying vibrational stimulus to accelerate OTM has been identified in previous animal studies [12, 13]. Recently, several clinical reports have investigated the effects of vibrations on the rate of tooth movement [1423]. Nevertheless, the methodological heterogeneity and inconclusive results of these studies could cause difficulties to evaluate evidences and mislead clinical practice. Therefore, a comprehensive systematic review addressing the effectiveness of vibration to accelerate OTM would be beneficial to practitioners.
In this study, we performed a critical systematic review on randomized controlled trials (RCT) and controlled clinical trials (CCT) to evaluate the efficacy of vibration in accelerating tooth movement in an evidence-based approach.

Methods

This systematic review was carried out and reported according to Cochrane Handbook for Systematic reviews of Interventions [24] and Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) [25]. Two review authors performed the literature search, study inclusion, data extraction and risk of bias assessment independently. Any discrepancy was resolved by reaching a consensus through discussion with a third reviewer.

Eligibility criteria

The inclusion criteria were as follows: (1) The study should evaluate the effectiveness of vibrational stimulus on OTM; (2) Study design: the study should be RCT or CCT; (3) Participants: subjects should be systematically healthy patients who require orthodontic treatment; (4) Type of interventions: subjects should be assigned to experimental or control/placebo group based on receiving vibrational stimulus or not; (5) Type of outcomes: indicator of tooth movement velocity and related treatment parameters.
The exclusion criteria were as follows: (1) Retrospective design, cohort study, case reports, descriptive studies or letters; (2) Animal experiments; (3) Participants with systematic diseases that affect bone metabolism or orthodontic treatment.

Information sources, search strategy, and study selection

PubMed, Embase, Cochrane Central Register of Controlled Trials (CENTRAL), and System for Information on Grey Literature in Europe (SIGLE) were searched for literature until Nov 2016. We adopted a combination of Medical Subject Headings (MeSH) with related free text words for the search in PubMed, and optimized the search strategy for each database respectively. The specific search strategies were presented in Table 1. In addition, a manual search was conducted among relevant journals and reference sections of retrieved records. The search was carried out in English without publication time limitation.
Table 1
Search strategies for Each Database
Step
PubMed
Embase, CENTRAL, & SIGLE
1
Vibration [Mesh] OR vibratory OR vibrational
vibration OR vibratory OR vibrational
2
Orthodontics [Mesh] OR orthodont*
Orthodontics OR orthodont*
3
Tooth movement [Mesh] OR move* OR retract*
tooth movement OR move* OR retract*
4
1 AND 2 AND 3
1 AND 2 AND 3
After the removal of duplicate records, the titles and abstracts of identified studies were screened to exclude irrelevant citations. The full-text of reserved studies were retrieved and assessed referring to eligibility criteria by two reviewers independently.

Data items and collection

A customized form was developed for data extraction. The general information of recruited studies including author, publication year, country, demographic information, vibration parameters, type of tooth movement, follow-ups and results were extracted.
The primary outcome of interest in this review was the rate of tooth movement, time needed to complete a predefined tooth movement and accumulated moved distance. The secondary outcome included patients’ quality of life and adverse effects like root resorption and discomfort.

Risk of bias in individual studies

The risk of bias of included trials were evaluated according to Cochrane Collaboration’s tool for assessing risk of bias [26]. This tool assesses the methodological quality of clinical trials through seven domains including random sequence generation, allocation concealment, blinding of participants and personnel, blinding of outcome assessment, incomplete outcome, selective reporting and other bias. The primary study was categorized as low risk when all items being assessed as low risk of bias, as unclear risk if one of more items being assessed as unclear risk of bias, and as high risk when one or more items being assessed as high risk of bias [26].

Summary measures and approach to synthesis

The original outcome data regarding the efficacy of vibration were extracted and had been planned to undergo statistical pooling when the heterogeneity of primary studies was acceptable. When conducting meta-analysis failed, a qualitative summarization of evidences was adopted. The quality of synthesized evidence was assessed using Grading of Recommendations Assessment, Development and Evaluation (GRADE) system [27].

Results

Study selection and characteristics

The details of search results are depicted in a PRISMA flow-diagram (Fig. 1). Three hundred fourteen studies were identified in the electronic databases, and two additional records were found through manual search. After removal of the duplicates, a total of 269 citations were screened based on title and abstract. Subsequently, full texts of the 14 reserved studies were retrieved for assessment referring to the inclusion and exclusion criteria. Finally, eight studies were included in the review [1623]. The Cohen’s-Kappa coefficient was used to measure inter-examiner agreement in the study selection process [24]. The kappa score was 0.86, indicating the interrater bias was low [28].
The general information of included studies was presented in Table 2. Out of the eight studies, seven were RCTs [1619, 2123] and one was demarcated as CCT [20]. Three publications were different parts of a same clinical trial, and were all included in this review since each of them reported an important outcome of vibration-assisted orthodontics respectively (tooth movement velocity, pain and discomfort, and root resorption) [1719]. The sample size of single primary study ranged from 15 to 81. A total of 305 participants were involved in present review, among which 149 subjects underwent vibrational stimulus and 171 patients were assigned into sham/control group (15 patients were involved in split-mouth design). The priori sample size calculation was conducted in seven studies [1619, 2123].
Table 2
Overview of included studies
Study ID
Study design
Origin
Participants description
grouping
Vibration device
Type of tooth movement
Miles (2012) [16]
RCT
Australia
n = 66; F:40; M:26;
Age:11–15
E:M:12;F:21;Age:13.0 ± 0.18y;
C:M:14; F:19;Age:13.1 ± 0.18y
Tooth Masseuse (111 Hz, 0.06 N)
Alignment of the 6 mandibular anterior teeth (3–3)
Pavlin (2015) [23]
RCT
USA
n = 45; Age:12–40
E:n = 23; C:n = 22
AcceleDent (30 Hz, 0.25 N)
Retraction of maxillary canine or maxillary anterior teeth (3–3).
Woodhouse
(2015a) [18]a
RCT
UK and Germany
n = 81; M:40, F:41.
Age: 14.06 ± 1.7y
E:n = 29; Age: 13.9 ± 1.6y
Sham: n = 25; Age: 14.1 ± 1.9y
C: n = 27; Age: 14.4 ± 1.8y
AcceleDent (30 Hz, 0.25 N)
Alignment of the mandibular arch in comprehensive treatment
Woodhouse
(2015b) [17]a
RCT
UK and Germany
n = 81; M:40, F:41.
Age: 14.1 ± 1.7y
E:n = 29;M:15, F:14; Age: 13.9 ± 1.6y
Sham: n = 25; M: 13, F:12 Age:13.8 ± 1.7y
C: n = 27; M:12, F:15; Age: 14.4 ± 1.9y
AcceleDent (30 Hz, 0.25 N)
Alignment of the mandibular arch in comprehensive treatment
Leethanakul (2016) [20]
CCT
Thailand
n = 15; M:4; F:11
Age:19-25y
Split-mouth design, the experimental tooth (right or left) was determined randomly.
A electronic toothbrush (Colgate) with a vibrating head (125 Hz)
Retraction of maxillary canines after complete alignment.
Lobre
(2016) [21]
RCT
USA
N = 58
E:n = 29
C:n = 29
AcceleDent(30 Hz, 0.25 N)
Alignment in comprehensive treatment
Miles
(2016) [22]
RCT
Australia
n = 40; M:14; F:26
Age:12.8 ± 1.3y
E:M:6; F:14; Age: 12.7 ± 1.2y
C:M:8; F:12; Age: 13.0 ± 1.5y
AcceleDent(30 Hz, 0.25 N)
Alignment of the 6 mandibular anterior teeth (3–3)
DiBiase
(2016) [19]a
RCT
UK and Germany
n = 81;
E:n = 29
Sham: n = 25
C: n = 27
AcceleDent (30 Hz, 0.25 N)
Alignment in comprehensi9ve treatment
aThe three publications are different parts of a same clinical trial
E experimental (vibration) group, C control group

Risk of bias within studies

The results of risk of bias assessment are summarized in Fig. 2. Among the eight studies, two studies (from a same clinical trial) were assessed as low risk of bias [17, 18], four were rated as unclear risk of bias [16, 19, 21, 22], and two were high risk of bias [20, 23]. Sixed studies adequately addressed random sequence generation [1719, 2123], and five of them were considered as reliable in allocation concealment [1719, 21, 22]. The items regarding randomization and allocation concealment in CCT were set by default as high risk [20]. Since the use of vibrational devices, participants could not be blinded, which might influence the visual analogue scale scoring for pain perceptions. Therefore four studies were assessed as unclear risk for performance bias [16, 2123]. Woodhouse et al. included a group of subjects using sham appliance and adequately considered the blind for participants regarding the allocation of functional and sham group [17]. Thus it was assessed as being free of performance bias [17]. Two studies did not report the details of missing data of drop-outs, thus were considered as unclear risk for attrition bias [16, 21]. High risk of other bias was present in two studies since split-mouth design and sponsorship from manufacturer of vibrational devices respectively [20, 23]. Unclear risk of other bias was detected in one study since root resorptions were evaluated using periapical radiographs [19].

Description of interventions

All the included studies investigated the effects of vibrational stimulus on orthodontic treatment, but the procedures of vibrational stimulus and tooth movement differed (Tables 2, 3). One study adopted Tooth Masseuse that provided a vibrational force of 111 Hz and 0.06 N for 20 min per day [16]. Six studies used AcceleDent (OrthoAccel Technologies, Inc., Bellaire, TX) which delivers a vibrational force of 0.25 N with a frequency of 30 Hz [1719, 2123]. The other one study employed an electrical toothbrush with a vibration head (125 Hz) [20]. When concerning the type of tooth movement, six studies investigated mandibular teeth alignment [1619, 21, 22] and the other two focused on maxillary canine retraction (Table 2) [20, 23].
Table 3
Characteristic of interventions and results
Study ID
Vibration details
Orthodontic treatment
Follow-ups
Tooth movement measurement
Primary result
Secondary result
Miles (2012) [16]
A vibrational device (Tooth Masseuse) provides vibration (111 Hz, 0.06 N) for 20 min per day.
Level and align the lower anterior teeth using 0.018*0.025-in. bracket slot system and 0.014 in. NITI wire in cases without extraction in lower arch or impacted teeth.
10 weeks (assessed at 5, 8 and 10 weeks after commencement)
Reduction in the irregularity assessed by Little’s Irregularity Index.
No differences in irregularity were observed at 5, 8 and 10 weeks after commencement between 2 groups.
No differences pain levels were observed at any time points between 2 groups.
Pavlin (2015) [23]
A vibrational device (AcceleDent) provides vibration (30 Hz, 0.25 N) for 20 min per day.
After complete alignment, maxillary canines or all 6 anterior teeth were retracted using miniscrews under force of 180 g, in patients that had maxillary first premolars extracted
Entire space closure
Measured using a digital caliper in patients’ mouth.
The rate of canine retraction was higher in the AcceleDent group (1.16 mm/month) than the control group (0.79 mm/month).
No differences in root resorption and pain levels were observed between 2 groups.
Woodhouse (2015a) [18]a
A vibrational device (AcceleDent) provides vibration (30 Hz, 0.2 N) for 20 min per day.
Level and align the mandibular arch using sequential arch wires (from 0.014-in NITI wire to 0.019*0.025-in stainless wire) in patients that had mandibular premolars extracted.
Entire alignment (from 0.014-in NITI wire to 0.019*0.025-in stainless wire)
Difference in the irregularity (Little’s irregularity index) divided by the number of days between measurements.
No significant difference in the rate of tooth movement or amount of required time among 3 groups.
Woodhouse
(2015b) [17]a
A vibrational device (AcceleDent) provides vibration (30 Hz, 0.2 N) for 20 min per day.
Level and align the mandibular arch using 0.014-in NiTi and 0.018-in NiTi wire in patients that had mandibular premolars extracted.
Initial alignment from 0.014-in NiTi wire to 0.018-in NiTi wire.
Difference of irregularity index of casts taken at placement of 0.014-in and 0.018-in NiTi wire divided by number of days between 2 measurements
No significant difference in the rate of tooth movement in the initial alignment phase was observed among 3 groups.
The maximum and mean pain intensity in the first week after placement of 0.014-in and 0.018-in NiTi wire similar among 3 groups
Leethanakul (2016) [20]
A electronic toothbrush (Colgate) with a rotating and vibrating head (125 Hz), which is used to provide mechanical vibration for a minimum of 5 min 3 times per day.
After complete alignment, the maxillary canine was retracted using elastomeric chain on the buccal and palatal side, under force of approximate 60 g, in patients that had maxillary first premolars extracted
2 months
Difference in the distance between canine and third rugae among consecutive models, assessed using digital caliper.
The accumulative amount of tooth movement was greater for the experimental canine (2.85 ± 0.17 mm) than for the control group (1.77 ± 0.11 mm).
Lobre
(2016) [21]
A vibrational device (AcceleDent) provides vibration (30 Hz, 0.25 N) for 20 min per day.
Level and align dentitions, and returned per months.
4 months
Vibrational stimulus significantly reduced the intensity of overall pain and biting pain.
Miles
(2016) [22]
A vibrational device (AcceleDent) provides vibration (30 Hz, 0.25 N) for 20 min per day.
Participants were Class II patients with maxillary premolars extracted and receiving comprehensive treatment in both archs. The dentitions were aligned using a 0.014-in thermal NiTi wire in the whole experiment.
10 weeks
Arch perimeter and irregularity of mandibular anterior teeth (3–3) assessed using Alginate impressions
No significant differences in anterior arch perimeters and irregularity were observed at 5, 8 or 10 weeks after commencement between 2 groups.
No significant difference of pain intensity in the first week after appliance placement.
DiBiase
(2016) [19]a
A vibrational device (AcceleDent) provides vibration (30 Hz, 0.2 N) for 20 min per day.
Level and align using sequential arch wires (from 0.014-in NITI wire to 0.019*0.025-in stainless wire) in patients that had mandibular premolars extracted.
Entire alignment (from 0.014-in NITI wire to 0.019*0.025-in stainless wire)
No significant difference in the external root resorptions of maxillary right central incisors among 3 groups.
aThe three publications are different parts of a same clinical tria

Results of individual studies and data synthesis

Since the substantial differences in vibration parameters, type of tooth movement and outcome measurements among included studies (Tables 2, 3), it is difficult to quantitatively combine the original outcome. Thus, the results of included trials were summarized qualitatively. The quality of synthesized evidence for each outcome was assessed using GRADE approach and presented in Table 4.
Table 4
GRADE assessment for quality of evidence
Patient or population: patients with orthodontic treatment Settings: RCT and CCT Intervention: vibrational stimulus
Outcomes
Illustrative comparative risks (95% CI)
Relative effect(95% CI)
No of Participants(studies)
Quality of the evidence(GRADE)
Comments
Assumed risk
Corresponding risk
 
Control
Vibrational stimulus
    
rate of OTM in alignment
See comment
See comment
Not estimable
187(3 studies)
⊕⊝⊝⊝very lowa,b,c
vibrational stimulus did not increase tooth movement in alignment
rate of OTM in canine retraction
See comment
See comment
Not estimable
60(2 studies)
⊕⊝⊝⊝very lowb,d,e
vibrational stimulus increased the rate of canine retraction
aUnclear risk in random sequence generation, allocation concealment, blinding of participants, incomplete reporting and other bias
bThe procedure of orthodontic treatment and vibrational stimulus and follow-up durations varied
cOnly three studies with limited sample size (n = 187) were included
dHigh risk of bias in randomization, blinding and other bias
eOnly two studies with limited sample size (n = 60) were included

Rate of tooth movement in alignment

Miles et al. compared the reduction of irregularity index of mandibular anterior teeth between patients receiving vibrational stimulus (Tooth Masseuse) or not. No significant difference of mean irregularity index reduction between two groups was detected at 5 (50% vs 45%), 8 (61% vs 61%) or 10 weeks (65% vs 69%) after commencement [16]. Thereafter, Miles et al. investigated the effectiveness of AcceleDent device in another trial, and observed similar rates of anterior lower teeth alignment between experimental and control groups [22]. Woodhouse and DiBiase et al. conducted a RCT involving patients treated with AcceleDent vibrational device, nonfunctional device or orthodontic treatment only, and reported results of alignment rate in two publications. One study showed that the time required for initial and final alignment of mandibular dentition were similar among three groups (initial alignment: 56.3 vs 59.8 vs 61.0 day; final alignment: 210.2 vs 217.5 vs 200.7 day) [18]. Similarly, the other study demonstrated no difference in the average rate of initial alignment was observed (0.10 ± 0.05 mm vs 0.11 ± 0.06 mm vs 0.10 ± 0.05 mm) [17]. These two publications were considered as one study for constructing body evidence (Table 4). According to GRADE, the quality of evidence on the effect of vibrations on alignment is assessed as very low (Table 4).

Rate of tooth movement in canine distalization

Pavlin et al. [23] reported the average rate of maxillary canine retraction was significantly enhanced by using AcceleDent device for 20 min per day (1.16, 95% CI: 0.86–1.45 mm/month vs 0.79, 95%CI: 0.49–1.09 mm/month). Leethanakul et al. [20] showed the accumulative distance of canine distalization on the quadrant receiving stimulation from a vibrating head (125 Hz) of electronic toothbrush was enhanced compared to the control side (2.85 ± 0.17 mm vs 1.77 ± 0.11 mm). The quality of evidence supporting the efficacy of vibrations on canine retraction is assessed as very low (Table 4).

Pain and discomfort

Five studies evaluated the effects of vibrational stimulus on pain intensities using visual analogue scale (VAS). Miles et al. found the use of vibratory device (Tooth Masseuse) did not reduce pain perceptions at 6-8 h (39.6 ± 25.8 mm vs 40.4 ± 20.8), 1 day (47.6 ± 24.5 mm vs 41.5 ± 27.2), 3 days (19.9 ± 15.5 mm vs 18.8 ± 18.5) and 7 days (5.5 ± 7.8 mm vs 4.0 ± 6.3) after placing appliances [16]. Similar results were observed in another RCT conducted by Miles et al., which adopted AcceleDent to produce vibrational stimulus [22]. Woodhouse et al. found either the maximum or mean pain intensities in the first week after placement of 0.014-in. and 0.018-in. NiTi archwires were similar among the vibration (AcceleDent), sham (nonfunctional AcceleDent) and control group [17]. Pavlin et al. also reported that no significant difference in pain or discomfort was detected in participants treated with vibrations or not. On contrary to the foregoing studies which suggested that vibrational stimulus did not influence pain levels, Lobre et al. evaluated the biting and overall pain in the first 4 month of treatment, and found that patients treated with vibration (AcceleDent) perceived both biting (P = 0.003) and overall pains (P = 0.002) of lower intensities during the whole study period [21].

Root resorption

DiBiase et al. evaluated the right maxillary central incisor lengths before and after alignment using periapical radiographs, and found the orthodontically induced inflammatory root resorption was not affected by application of supplemental vibrational force [17]. Similarly, Pavlin et al. reported no difference in root resorption after canine retraction between patients using vibrational device (AcceleDent) or not [23].

Discussion

To our knowledge, this is the first systematic review addressing the efficacy of vibrational stimulus to accelerate OTM. This review included eight prospective clinical trials comprising an overall sample of 305 patients. The heterogeneity in methodology and non-comparability of outcome measures in retrieved publications prevented a quantitative synthesis from being performed. Therefore, we collected, appraised and qualitatively synthesized the currently available literatures to provide evidence regarding this issue.
Four studies [1618, 22] in this review investigated the rate of tooth movement in alignment, two of which were the different parts of a same RCT [17, 18]. All of the four publications reported that the use of vibratory device could not enhance the velocity of tooth movement during alignment (Table 3). However, this result should be interpreted with caution since following reasons. Firstly, only four publications (three clinical trials) are included for this outcome, and the methodological flaws are noteworthy (Fig. 2). Secondly, vibrational stimuli are different in the four studies (Tables 2, 3). Thirdly, Studies reported by Miles et al. [16, 22] focused on the alignment of lower anterior teeth in patients without extraction in mandible while the other two studies reported by Woodhouse et al. [17, 18] aligned the whole mandibular dentition in patients that had mandibular first premolars extracted (Table 3). Due to the reasons above, quality of this evidence was assessed as very low quality referring to GRADE guidance (Table 4) [27].
Two studies [20, 23] evaluated the effects of vibration on canine distalization in patients that had maxillary first premolar extracted (Tables 2, 3). Results of the two studies advocated the advantage of vibrational forces in acclerating canine retraction (Table 3). Leethanakul et al. detected enhanced IL-1β secretion in gingival crevicular fluid in quadrant receiving vibrational stimulus compared to the control quadrant [20]. IL-1 could induce RANKL expression in osteoblasts and periodontal ligament cells, and also promote the differentiation of pre-osteoclast [29]. Interestingly, a well-designed animal study indicated that vibration could promote osteoclast formation via enhancing RANKL expression in periodontal tissue and thus facilitate alveolar bone remodeling and lead to faster tooth movement [13]. These studies suggested that vibrational stimulus could accelerate OTM through promoting osteoclast formation and alveolar bone remodeling. However, current evidence supporting the effectiveness of vibration on accelerating canine distalization is of very low quality, mainly due to the lack of high-quality primary studies and methodological heterogeneity (Table 4).
Vibratory stimulations have been proved to reduce pain perceptions in different fields [30, 31]. Five studies in this review investigated effects of vibrations on orthodontic pain (Table 3). However, the reliability of these results is questionable since the absence of blinding to participants could influence the VAS scoring for pain levels. Only one study was free of this bias since it included participants intervened with identical non-functional device and concealed the allocation of functional and non-functional group, which suggested that vibration did not influence pain levels [17]. Anyway, no conclusion concerning the effects of vibration on pain and discomfort could be drawn based on current information.
Root resorption is one of the main complications in orthodontic treatment [32]. DeBiase et al. assessed the changes of root lengths after orthodontic treatment using periapical radiographs [19]. However, film radiographs could only provide information of apical root resorptions. The resorptions occurring at other sites on root could be underestimated [33]. Another study observed no impact of vibrations on root resorptions. Nevertheless, no details of measurements and outcomes were reported [23]. In general, no reliable result on root resorption is available yet.
OTM is the consequence of tissue remodeling within periodontium induced by external forces [34]. Most of the current adjunctive interventions, like corticotomy, enhance the rate of tooth movement by promoting alveolar bone remodeling [35]. The anabolic effects of supplemental vibrational therapy on bone metabolism have been long recognized [36]. Its effectiveness in promoting suture growth and remodeling in craniofacial region has also been identified [37]. A recent study indicates that vibration could accelerate OTM through promoting alveolar bone remodeling [13]. However, another experiment found that mechanical vibration did not increase the number of osteoclasts or rate of tooth movement [38]. It should be noted that distinguished difference of vibration frequency exists in these two animal studies (60 vs 5–20 Hz), indicating that vibratory stimulus could act in a frequency-dependent manner. Therefore, future clinical trials should be carried out to explore the optimal protocols of vibratory forces for accelerating OTM.
Although this systematic review was performed carefully following normalized procedures, several limitations which deserved further discussion still existed. First, the shortage of high-quality clinical trials is evident. Though a comprehensive literature search was performed, only eight studies were included in this review. Future well-designed studies are needed to obtain a more reliable conclusion. Second, the methodological heterogeneity and non-comparability of original outcomes could bias the qualitative summarization of this review. Third, the publication bias has not been investigated since the weak statistical power when included publications are limited [39]. Fourth, the language restriction in literature search could have introduced bias into this review.

Conclusions

Based on current information, weak evidence suggests that vibrational stimulus is effective for accelerating tooth movement in canine retraction but not in the alignment phase. The effects of vibration on pain intensity and root resorption during orthodontic treatment are inconclusive. There is a need for well-designed randomized controlled trials to obtain more reliable results.

Acknowledgements

Not applicable.

Funding

This work was supported by the National Nature Science Foundation of China (Nos.31470904 and 11372202).

Availability of data and materials

The summary of data extraction in this study is available upon request to the corresponding author.
Not applicable.
Not applicable.

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
Literatur
1.
Zurück zum Zitat Fisher MA, Wenger RM, Hans MG. Pretreatment characteristics associated with orthodontic treatment duration. Am J Orthod Dentofac Orthop. 2010;137:178–86.CrossRef Fisher MA, Wenger RM, Hans MG. Pretreatment characteristics associated with orthodontic treatment duration. Am J Orthod Dentofac Orthop. 2010;137:178–86.CrossRef
2.
Zurück zum Zitat Mavreas D, Athanasiou AE. Factors affecting the duration of orthodontic treatment: a systematic review. Eur J Orthod. 2008;30:386–95.CrossRefPubMed Mavreas D, Athanasiou AE. Factors affecting the duration of orthodontic treatment: a systematic review. Eur J Orthod. 2008;30:386–95.CrossRefPubMed
3.
Zurück zum Zitat Geiger AM, Gorelick L, Gwinnett AJ, Benson BJ. Reducing white spot lesions in orthodontic populations with fluoride rinsing. Am J Orthod Dentofac Orthop. 1992;101:403–7.CrossRef Geiger AM, Gorelick L, Gwinnett AJ, Benson BJ. Reducing white spot lesions in orthodontic populations with fluoride rinsing. Am J Orthod Dentofac Orthop. 1992;101:403–7.CrossRef
4.
Zurück zum Zitat Pandis N, Nasika M, Polychronopoulou A, Eliades T. External apical root resorption in patients treated with conventional and self-ligating brackets. Am J Orthod Dentofac Orthop. 2008;134:646–51.CrossRef Pandis N, Nasika M, Polychronopoulou A, Eliades T. External apical root resorption in patients treated with conventional and self-ligating brackets. Am J Orthod Dentofac Orthop. 2008;134:646–51.CrossRef
5.
Zurück zum Zitat Gkantidis N, Mistakidis I, Kouskoura T, Pandis N. Effectiveness of non-conventional methods for accelerated orthodontic tooth movement: a systematic review and meta-analysis. J Dent. 2014;42:1300–19.CrossRefPubMed Gkantidis N, Mistakidis I, Kouskoura T, Pandis N. Effectiveness of non-conventional methods for accelerated orthodontic tooth movement: a systematic review and meta-analysis. J Dent. 2014;42:1300–19.CrossRefPubMed
6.
Zurück zum Zitat El-Angbawi A, McIntyre GT, Fleming PS, Bearn DR. Non-surgical adjunctive interventions for accelerating tooth movement in patients undergoing fixed orthodontic treatment. Cochrane Database Syst Rev. 2015;18:Cd010887. El-Angbawi A, McIntyre GT, Fleming PS, Bearn DR. Non-surgical adjunctive interventions for accelerating tooth movement in patients undergoing fixed orthodontic treatment. Cochrane Database Syst Rev. 2015;18:Cd010887.
7.
Zurück zum Zitat Fleming PS, Fedorowicz Z, Johal A, El-Angbawi A, Pandis N. Surgical adjunctive procedures for accelerating orthodontic treatment. Cochrane Database Syst Rev. 2015;30:Cd010572. Fleming PS, Fedorowicz Z, Johal A, El-Angbawi A, Pandis N. Surgical adjunctive procedures for accelerating orthodontic treatment. Cochrane Database Syst Rev. 2015;30:Cd010572.
9.
Zurück zum Zitat Kalemaj Z, Debernard IC, Buti J. Efficacy of surgical and non-surgical interventions on accelerating orthodontic tooth movement: a systematic review. Eur J Oral Implantol. 2015;8:9–24.PubMed Kalemaj Z, Debernard IC, Buti J. Efficacy of surgical and non-surgical interventions on accelerating orthodontic tooth movement: a systematic review. Eur J Oral Implantol. 2015;8:9–24.PubMed
10.
Zurück zum Zitat Showkatbakhsh R, Jamilian A, Showkatbakhsh M. The effect of pulsed electromagnetic fields on the acceleration of tooth movement. World J Orthod. 2010;11:e52–6.PubMed Showkatbakhsh R, Jamilian A, Showkatbakhsh M. The effect of pulsed electromagnetic fields on the acceleration of tooth movement. World J Orthod. 2010;11:e52–6.PubMed
11.
Zurück zum Zitat Kau CH, Kantarci A, Shaughnessy T, Vachiramon A, Santiwong P, de la Fuente A, Skrenes D, Ma D, Brawn P. Photobiomodulation accelerates orthodontic alignment in the early phase of treatment. Prog Orthod. 2013;14:30.CrossRefPubMedPubMedCentral Kau CH, Kantarci A, Shaughnessy T, Vachiramon A, Santiwong P, de la Fuente A, Skrenes D, Ma D, Brawn P. Photobiomodulation accelerates orthodontic alignment in the early phase of treatment. Prog Orthod. 2013;14:30.CrossRefPubMedPubMedCentral
12.
Zurück zum Zitat Darendeliler MA, Zea A, Shen G, Zoellner H. Effects of pulsed electromagnetic field vibration on tooth movement induced by magnetic and mechanical forces: a preliminary study. Aust Dent J. 2007;52:282–7.CrossRefPubMed Darendeliler MA, Zea A, Shen G, Zoellner H. Effects of pulsed electromagnetic field vibration on tooth movement induced by magnetic and mechanical forces: a preliminary study. Aust Dent J. 2007;52:282–7.CrossRefPubMed
13.
Zurück zum Zitat Nishimura M, Chiba M, Ohashi T, Sato M, Shimizu Y, Igarashi K, Mitani H. Periodontal tissue activation by vibration: intermittent stimulation by resonance vibration accelerates experimental tooth movement in rats. Am J Orthod Dentofac Orthop. 2008;133:572–83.CrossRef Nishimura M, Chiba M, Ohashi T, Sato M, Shimizu Y, Igarashi K, Mitani H. Periodontal tissue activation by vibration: intermittent stimulation by resonance vibration accelerates experimental tooth movement in rats. Am J Orthod Dentofac Orthop. 2008;133:572–83.CrossRef
14.
Zurück zum Zitat Bowman SJ. The effect of vibration on the rate of leveling and alignment. J Clin Orthod. 2014;48:678–88.PubMed Bowman SJ. The effect of vibration on the rate of leveling and alignment. J Clin Orthod. 2014;48:678–88.PubMed
15.
Zurück zum Zitat Orton-Gibbs S, Kim NY. Clinical experience with the use of pulsatile forces to accelerate treatment. J Clin Orthod. 2015;49:557–73.PubMed Orton-Gibbs S, Kim NY. Clinical experience with the use of pulsatile forces to accelerate treatment. J Clin Orthod. 2015;49:557–73.PubMed
16.
Zurück zum Zitat Miles P, Smith H, Weyant R, Rinchuse DJ. The effects of a vibrational appliance on tooth movement and patient discomfort: a prospective randomised clinical trial. Aust Orthod J. 2012;28:213–8.PubMed Miles P, Smith H, Weyant R, Rinchuse DJ. The effects of a vibrational appliance on tooth movement and patient discomfort: a prospective randomised clinical trial. Aust Orthod J. 2012;28:213–8.PubMed
17.
Zurück zum Zitat Woodhouse NR, DiBiase AT, Papageorgiou SN, Johnson N, Slipper C, Grant J, Alsaleh M, Cobourne MT. Supplemental vibrational force does not reduce pain experience during initial alignment with fixed orthodontic appliances: a multicenter randomized clinical trial. Sci Rep. 2015;5:17224.CrossRefPubMedPubMedCentral Woodhouse NR, DiBiase AT, Papageorgiou SN, Johnson N, Slipper C, Grant J, Alsaleh M, Cobourne MT. Supplemental vibrational force does not reduce pain experience during initial alignment with fixed orthodontic appliances: a multicenter randomized clinical trial. Sci Rep. 2015;5:17224.CrossRefPubMedPubMedCentral
18.
Zurück zum Zitat Woodhouse NR, DiBiase AT, Johnson N, Slipper C, Grant J, Alsaleh M, Donaldson AN, Cobourne MT. Supplemental vibrational force during orthodontic alignment: a randomized trial. J Dent Res. 2015;94:682–9.CrossRefPubMed Woodhouse NR, DiBiase AT, Johnson N, Slipper C, Grant J, Alsaleh M, Donaldson AN, Cobourne MT. Supplemental vibrational force during orthodontic alignment: a randomized trial. J Dent Res. 2015;94:682–9.CrossRefPubMed
19.
Zurück zum Zitat DiBiase AT, Woodhouse NR, Papageorgiou SN, Johnson N, Slipper C, Grant J, Alsaleh M, Cobourne MT. Effect of supplemental vibrational force on orthodontically induced inflammatory root resorption: a multicenter randomized clinical trial. Am J Orthod Dentofac Orthop. 2016;150:918–27.CrossRef DiBiase AT, Woodhouse NR, Papageorgiou SN, Johnson N, Slipper C, Grant J, Alsaleh M, Cobourne MT. Effect of supplemental vibrational force on orthodontically induced inflammatory root resorption: a multicenter randomized clinical trial. Am J Orthod Dentofac Orthop. 2016;150:918–27.CrossRef
20.
Zurück zum Zitat Leethanakul C, Suamphan S, Jitpukdeebodintra S, Thongudomporn U, Charoemratrote C. Vibratory stimulation increases interleukin-1 beta secretion during orthodontic tooth movement. Angle Orthod. 2016;86:74–80.CrossRefPubMed Leethanakul C, Suamphan S, Jitpukdeebodintra S, Thongudomporn U, Charoemratrote C. Vibratory stimulation increases interleukin-1 beta secretion during orthodontic tooth movement. Angle Orthod. 2016;86:74–80.CrossRefPubMed
21.
Zurück zum Zitat Lobre WD, Callegari BJ, Gardner G, Marsh CM, Bush AC, Dunn WJ. Pain control in orthodontics using a micropulse vibration device: a randomized clinical trial. Angle Orthod. 2016;86:625–30.CrossRefPubMed Lobre WD, Callegari BJ, Gardner G, Marsh CM, Bush AC, Dunn WJ. Pain control in orthodontics using a micropulse vibration device: a randomized clinical trial. Angle Orthod. 2016;86:625–30.CrossRefPubMed
22.
Zurück zum Zitat Miles P, Fisher E. Assessment of the changes in arch perimeter and irregularity in the mandibular arch during initial alignment with the AcceleDent Aura appliance vs no appliance in adolescents: a single-blind randomized clinical trial. Am J Orthod Dentofac Orthop. 2016;150:928–36.CrossRef Miles P, Fisher E. Assessment of the changes in arch perimeter and irregularity in the mandibular arch during initial alignment with the AcceleDent Aura appliance vs no appliance in adolescents: a single-blind randomized clinical trial. Am J Orthod Dentofac Orthop. 2016;150:928–36.CrossRef
23.
Zurück zum Zitat Pavlin D, Anthony R, Raj V, PT G. Cyclic loading (vibration) accelerates tooth movement in orthodontic patients: a double-blind, randomized controlled trial. Semin Orthod. 2015;21:187–94.CrossRef Pavlin D, Anthony R, Raj V, PT G. Cyclic loading (vibration) accelerates tooth movement in orthodontic patients: a double-blind, randomized controlled trial. Semin Orthod. 2015;21:187–94.CrossRef
24.
Zurück zum Zitat Higgins J, Green S. Cochrane handbook for systematic reviews of interventions. Chichester: Wiley; 2009. Higgins J, Green S. Cochrane handbook for systematic reviews of interventions. Chichester: Wiley; 2009.
25.
Zurück zum Zitat Moher D, Liberati A, Tetzlaff J, Altman DG, Group P. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. BMJ. 2009;339:b2535.CrossRefPubMedPubMedCentral Moher D, Liberati A, Tetzlaff J, Altman DG, Group P. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. BMJ. 2009;339:b2535.CrossRefPubMedPubMedCentral
26.
Zurück zum Zitat Higgins JP, Altman DG, Gotzsche PC, Juni P, Moher D, Oxman AD, Savovic J, Schulz KF, Weeks L, Sterne JA, et al. The Cochrane Collaboration's tool for assessing risk of bias in randomised trials. BMJ. 2011;343:d5928.CrossRefPubMedPubMedCentral Higgins JP, Altman DG, Gotzsche PC, Juni P, Moher D, Oxman AD, Savovic J, Schulz KF, Weeks L, Sterne JA, et al. The Cochrane Collaboration's tool for assessing risk of bias in randomised trials. BMJ. 2011;343:d5928.CrossRefPubMedPubMedCentral
27.
Zurück zum Zitat Guyatt GH, Oxman AD, Vist GE, Kunz R, Falck-Ytter Y, Alonso-Coello P, Schunemann HJ, Group GW. GRADE an emerging consensus on rating quality of evidence and strength of recommendations. BMJ. 2008;336:924–6.CrossRefPubMedPubMedCentral Guyatt GH, Oxman AD, Vist GE, Kunz R, Falck-Ytter Y, Alonso-Coello P, Schunemann HJ, Group GW. GRADE an emerging consensus on rating quality of evidence and strength of recommendations. BMJ. 2008;336:924–6.CrossRefPubMedPubMedCentral
28.
Zurück zum Zitat Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33:159–74.CrossRefPubMed Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33:159–74.CrossRefPubMed
29.
Zurück zum Zitat Teixeira CC, Khoo E, Tran J, Chartres I, Liu Y, Thant LM, Khabensky I, Gart LP, Cisneros G, Alikhani M. Cytokine expression and accelerated tooth movement. J Dent Res. 2010;89:1135–41.CrossRefPubMedPubMedCentral Teixeira CC, Khoo E, Tran J, Chartres I, Liu Y, Thant LM, Khabensky I, Gart LP, Cisneros G, Alikhani M. Cytokine expression and accelerated tooth movement. J Dent Res. 2010;89:1135–41.CrossRefPubMedPubMedCentral
30.
Zurück zum Zitat Lundeberg T, Nordemar R, Ottoson D. Pain alleviation by vibratory stimulation. Pain. 1984;20:25–44.CrossRefPubMed Lundeberg T, Nordemar R, Ottoson D. Pain alleviation by vibratory stimulation. Pain. 1984;20:25–44.CrossRefPubMed
31.
Zurück zum Zitat Roy EA, Hollins M, Maixner W. Reduction of TMD pain by high-frequency vibration: a spatial and temporal analysis. Pain. 2003;101:267–74.CrossRefPubMed Roy EA, Hollins M, Maixner W. Reduction of TMD pain by high-frequency vibration: a spatial and temporal analysis. Pain. 2003;101:267–74.CrossRefPubMed
32.
Zurück zum Zitat Weltman B, Vig KW, Fields HW, Shanker S, Kaizar EE. Root resorption associated with orthodontic tooth movement: a systematic review. Am J Orthod Dentofac Orthop. 2010;137:462–76.CrossRef Weltman B, Vig KW, Fields HW, Shanker S, Kaizar EE. Root resorption associated with orthodontic tooth movement: a systematic review. Am J Orthod Dentofac Orthop. 2010;137:462–76.CrossRef
33.
Zurück zum Zitat Yi J, Sun Y, Li Y, Li C, Li X, Zhao Z. Cone-beam computed tomography versus periapical radiograph for diagnosing external root resorption: a systematic review and meta-analysis. Angle Orthod. 2016;87:328–37.CrossRefPubMed Yi J, Sun Y, Li Y, Li C, Li X, Zhao Z. Cone-beam computed tomography versus periapical radiograph for diagnosing external root resorption: a systematic review and meta-analysis. Angle Orthod. 2016;87:328–37.CrossRefPubMed
35.
Zurück zum Zitat Alikhani M, Raptis M, Zoldan B, Sangsuwon C, Lee YB, Alyami B, Corpodian C, Barrera LM, Alansari S, Khoo E, et al. Effect of micro-osteoperforations on the rate of tooth movement. Am J Orthod Dentofac Orthop. 2013;144:639–48.CrossRef Alikhani M, Raptis M, Zoldan B, Sangsuwon C, Lee YB, Alyami B, Corpodian C, Barrera LM, Alansari S, Khoo E, et al. Effect of micro-osteoperforations on the rate of tooth movement. Am J Orthod Dentofac Orthop. 2013;144:639–48.CrossRef
36.
Zurück zum Zitat Rubin C, Turner AS, Muller R, Mittra E, McLeod K, Lin W, Qin YX. Quantity and quality of trabecular bone in the femur are enhanced by a strongly anabolic, noninvasive mechanical intervention. J Bone Miner Res. 2002;17:349–57.CrossRefPubMed Rubin C, Turner AS, Muller R, Mittra E, McLeod K, Lin W, Qin YX. Quantity and quality of trabecular bone in the femur are enhanced by a strongly anabolic, noninvasive mechanical intervention. J Bone Miner Res. 2002;17:349–57.CrossRefPubMed
37.
Zurück zum Zitat Peptan AI, Lopez A, Kopher RA, Mao JJ. Responses of intramembranous bone and sutures upon in vivo cyclic tensile and compressive loading. Bone. 2008;42:432–8.CrossRefPubMed Peptan AI, Lopez A, Kopher RA, Mao JJ. Responses of intramembranous bone and sutures upon in vivo cyclic tensile and compressive loading. Bone. 2008;42:432–8.CrossRefPubMed
38.
Zurück zum Zitat Yadav S, Dobie T, Assefnia A, Gupta H, Kalajzic Z, Nanda R. Effect of low-frequency mechanical vibration on orthodontic tooth movement. Am J Orthod Dentofac Orthop. 2015;148:440–9.CrossRef Yadav S, Dobie T, Assefnia A, Gupta H, Kalajzic Z, Nanda R. Effect of low-frequency mechanical vibration on orthodontic tooth movement. Am J Orthod Dentofac Orthop. 2015;148:440–9.CrossRef
39.
Zurück zum Zitat Song F, Eastwood AJ, Gilbody S, Duley L, Sutton AJ. Publication and related biases. Health Technol Assess. 2000;4:1–115. Song F, Eastwood AJ, Gilbody S, Duley L, Sutton AJ. Publication and related biases. Health Technol Assess. 2000;4:1–115.
Metadaten
Titel
The effectiveness of vibrational stimulus to accelerate orthodontic tooth movement: a systematic review
verfasst von
Dian Jing
Jiani Xiao
Xiaobing Li
Yu Li
Zhihe Zhao
Publikationsdatum
01.12.2017
Verlag
BioMed Central
Erschienen in
BMC Oral Health / Ausgabe 1/2017
Elektronische ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-017-0437-7

Weitere Artikel der Ausgabe 1/2017

BMC Oral Health 1/2017 Zur Ausgabe

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.