Skip to main content
Erschienen in: International Orthopaedics 5/2019

21.07.2018 | Original Paper

The efficacy of dual-mobility cup in preventing dislocation after total hip arthroplasty: a systematic review and meta-analysis of comparative studies

verfasst von: Matteo Romagnoli, Alberto Grassi, Giuseppe Gianluca Costa, Lionel E Lazaro, Mirco Lo Presti, Stefano Zaffagnini

Erschienen in: International Orthopaedics | Ausgabe 5/2019

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Although long-term reports of total hip arthroplasty (THA) showed successful results, instability remains a major complication. Recently, dual-mobility cups (DMC) have gained more and more interest among clinicians, with encouraging results in terms of lower rate of dislocation associated with good clinical results, but a lack of evidence exists regarding the real efficacy of this implant design compared to traditional fixed-bearing total hip arthroplasties.

Methods

A systematic search was performed in PubMed, Google scholar, Cochrane Library, and EMBASE by two independent reviewers for comparative studies available till December 2017, with the primary objective to demonstrate a real lower dislocation rate of DMC implants compared to unipolar fixed-bearing cup designs. A meta-analysis was conducted with the collected pooled data about dislocation rate, calculating the risk difference (RD) and relative risk (RR) with 95% CI for dichotomous variables. Heterogeneity was tested using the χ2 and Higgins’ I2 tests. A fixed-effect model was used because the statistical heterogeneity was below 50%.

Results

After performing a critical exclusion process, the number of eligible studies included for final synthesis considered was 15, describing the results of a total of 2408 total hip arthroplasties (50.6% with a dual-mobility acetabular cup design, 49.4% with a standard fixed-bearing design). The fixed-effect meta-analysis showed a slight significant risk ratio of 0.16 (95% CI, 0.09, 0.28; I2 = 0%, p < 0.00001); a statistically significant difference in favor of the DMC group was maintained also considering only primary or revision arthroplasties, traumatic fractures or elective patients with diagnosis of osteoarthritis, avascular osteonecrosis or rheumatic arthritis.

Conclusions

With the intrinsic limitations of our study design and based on the current available data, this study demonstrates that dual-mobility acetabular components decrease the risk of post-operative instability also in high-risk patients, both in primary and revision hip arthroplasties. However, new high-quality studies, possibly with a randomized control design, should be undertaken in order to strengthen the present data.

Study design

Level of Evidence III, therapeutic study.
Literatur
1.
Zurück zum Zitat Patel PD, Potts A, Froimson MI (2007) The dislocating hip arthroplasty: prevention and treatment. J Arthroplast 22(suppl 1):86–90CrossRef Patel PD, Potts A, Froimson MI (2007) The dislocating hip arthroplasty: prevention and treatment. J Arthroplast 22(suppl 1):86–90CrossRef
2.
Zurück zum Zitat Bystrom S, Espehaug B, Furnes O, Havelin LI (2003) Femoral head size is a risk factor for total hip luxation. Acta Orthop Scand 74(5):514–524CrossRef Bystrom S, Espehaug B, Furnes O, Havelin LI (2003) Femoral head size is a risk factor for total hip luxation. Acta Orthop Scand 74(5):514–524CrossRef
3.
Zurück zum Zitat Khatod M, Barber T, Paxton E, Namba R, Fithian D (2006) An analysis of hip dislocation with a contemporary total joint registry. Clin Orthop Relat Res 453:19–23CrossRef Khatod M, Barber T, Paxton E, Namba R, Fithian D (2006) An analysis of hip dislocation with a contemporary total joint registry. Clin Orthop Relat Res 453:19–23CrossRef
4.
Zurück zum Zitat Meek RMD, Allan DB, McPhillips G, Kerr L, Howie CR (2006) Epidemiology of dislocation after total hip arthroplasty. J Bone Joint Surg 447:9–18 Meek RMD, Allan DB, McPhillips G, Kerr L, Howie CR (2006) Epidemiology of dislocation after total hip arthroplasty. J Bone Joint Surg 447:9–18
9.
Zurück zum Zitat Berry DJ, Von Knoch M, Schleck CD, Harmsen WS (2004) The cumulative long-term risk of dislocation after primary Charnley total hip arthroplasty. J Bone Joint Surg Am 86.A(1):9–14CrossRef Berry DJ, Von Knoch M, Schleck CD, Harmsen WS (2004) The cumulative long-term risk of dislocation after primary Charnley total hip arthroplasty. J Bone Joint Surg Am 86.A(1):9–14CrossRef
10.
Zurück zum Zitat Dargel J, Oppermann J, Brüggemann GP, Eysel P (2014) Dislocation following total hip replacement. Dtsch Arztebl Int 111(51–52):884–890PubMedPubMedCentral Dargel J, Oppermann J, Brüggemann GP, Eysel P (2014) Dislocation following total hip replacement. Dtsch Arztebl Int 111(51–52):884–890PubMedPubMedCentral
11.
Zurück zum Zitat Guo L, Yang Y, An B, Yang Y, Shi L, Han X, Gao S (2017) Risk factors for dislocation after revision total hip arthroplasty: a systematic review and meta-analysis. Int J Surg 38:123–129CrossRef Guo L, Yang Y, An B, Yang Y, Shi L, Han X, Gao S (2017) Risk factors for dislocation after revision total hip arthroplasty: a systematic review and meta-analysis. Int J Surg 38:123–129CrossRef
12.
Zurück zum Zitat Williams JT Jr, Ragland PS, Clarke S (2007) Constrained components for the unstable hip arthroplasty: a literature review. Int Orthop 31(3):273–277CrossRef Williams JT Jr, Ragland PS, Clarke S (2007) Constrained components for the unstable hip arthroplasty: a literature review. Int Orthop 31(3):273–277CrossRef
13.
Zurück zum Zitat Guyen O (2017) Constrained liners, dual mobility or large diameter heads to avoid dislocation in THA. EFORT Open Rev 1(5):197–204CrossRef Guyen O (2017) Constrained liners, dual mobility or large diameter heads to avoid dislocation in THA. EFORT Open Rev 1(5):197–204CrossRef
14.
Zurück zum Zitat Boyer B, Philippot R, Geringer J, Farizon F (2012) Primary total hip arthroplasty with dual mobility socket to prevent dislocation: a 22-year follow-up of 240 hips. Int Orthop 36:511–518CrossRef Boyer B, Philippot R, Geringer J, Farizon F (2012) Primary total hip arthroplasty with dual mobility socket to prevent dislocation: a 22-year follow-up of 240 hips. Int Orthop 36:511–518CrossRef
15.
Zurück zum Zitat De Martino I, D’Apolito R, Soranoglou VG, Poultsides LA, Sculco PK, Sculco TP (2017) Dislocation following total hip arthroplasty using dual mobility acetabular components: a systematic review. Bone Joint J 99-B(ASuppl1):18–24CrossRef De Martino I, D’Apolito R, Soranoglou VG, Poultsides LA, Sculco PK, Sculco TP (2017) Dislocation following total hip arthroplasty using dual mobility acetabular components: a systematic review. Bone Joint J 99-B(ASuppl1):18–24CrossRef
16.
Zurück zum Zitat Charnley J (1972) The long-term results of low-friction arthroplasty of the hip performed as a primary intervention. J Bone Joint Surg (Br) 54-B:61–76CrossRef Charnley J (1972) The long-term results of low-friction arthroplasty of the hip performed as a primary intervention. J Bone Joint Surg (Br) 54-B:61–76CrossRef
17.
Zurück zum Zitat McKee GK, Watson-Farrar J (1966) Replacement of arthritic hips by the McKee-Farrar prosthesis. J Bone Joint Surg (Br) 48-B:245–259CrossRef McKee GK, Watson-Farrar J (1966) Replacement of arthritic hips by the McKee-Farrar prosthesis. J Bone Joint Surg (Br) 48-B:245–259CrossRef
19.
Zurück zum Zitat Philippot R, Boyer B, Farizon F (2013) Intraprosthetic dislocation: a specific complication of the dual-mobility system. Clin Orthop Relat Res 471:965–970CrossRef Philippot R, Boyer B, Farizon F (2013) Intraprosthetic dislocation: a specific complication of the dual-mobility system. Clin Orthop Relat Res 471:965–970CrossRef
20.
Zurück zum Zitat Moher D, Liberati A, Tetzlaff J, Altman DG, PRISMA Group (2009) Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. BMJ 339:b2535CrossRef Moher D, Liberati A, Tetzlaff J, Altman DG, PRISMA Group (2009) Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. BMJ 339:b2535CrossRef
21.
Zurück zum Zitat Adam P, Philippe R, Ehlinger M, Roche O, Bonnomet F, Molé D, Fessy MH, French Society of Orthopaedic Surgery and Traumatology SoFCOT (2012) Dual mobility cups hip arthroplasty as a treatment for displaced fracture of the femoral neck in the elderly. A prospective, systematic, multicenter study with specific focus on postoperative dislocation. Orthop Traumatol Surg Res 98:296–300CrossRef Adam P, Philippe R, Ehlinger M, Roche O, Bonnomet F, Molé D, Fessy MH, French Society of Orthopaedic Surgery and Traumatology SoFCOT (2012) Dual mobility cups hip arthroplasty as a treatment for displaced fracture of the femoral neck in the elderly. A prospective, systematic, multicenter study with specific focus on postoperative dislocation. Orthop Traumatol Surg Res 98:296–300CrossRef
22.
Zurück zum Zitat Prudhon JL, Desmarchelier R, Hamadouche M, Delaunay C, Verdier R, SoFCOT (2017) Causes for revision of dual-mobility and standard primary total hip arthroplasty: matched case-control study based on a prospective multicenter study of two thousand and forty four implants. Int Orthop 41(3):455–459CrossRef Prudhon JL, Desmarchelier R, Hamadouche M, Delaunay C, Verdier R, SoFCOT (2017) Causes for revision of dual-mobility and standard primary total hip arthroplasty: matched case-control study based on a prospective multicenter study of two thousand and forty four implants. Int Orthop 41(3):455–459CrossRef
23.
Zurück zum Zitat Epinette JA, Lafuma A, Robert J, Doz M (2016) Cost-effectiveness model comparing dual-mobility to fixed-bearing designs for total hip replacement in France. Orthop Traumatol Surg Res 102(2):143–148CrossRef Epinette JA, Lafuma A, Robert J, Doz M (2016) Cost-effectiveness model comparing dual-mobility to fixed-bearing designs for total hip replacement in France. Orthop Traumatol Surg Res 102(2):143–148CrossRef
24.
Zurück zum Zitat Gaudin G, Ferreira A, Gaillard R, Prudhon JL, Caton JH, Lustig S (2017) Equivalent wear performance of dual mobility bearing compared with standard bearing in total hip arthroplasty: in vitro study. Int Orthop 41(3):521–527CrossRef Gaudin G, Ferreira A, Gaillard R, Prudhon JL, Caton JH, Lustig S (2017) Equivalent wear performance of dual mobility bearing compared with standard bearing in total hip arthroplasty: in vitro study. Int Orthop 41(3):521–527CrossRef
25.
Zurück zum Zitat Wegrzyn J, Thoreson AR, Guyen O, Lewallen DG, An KN (2013) Cementation of a dual-mobility acetabular component into a well-fixed metal shell during revision total hip arthroplasty: a biomechanical validation. J Orthop Res 31(6):991–997CrossRef Wegrzyn J, Thoreson AR, Guyen O, Lewallen DG, An KN (2013) Cementation of a dual-mobility acetabular component into a well-fixed metal shell during revision total hip arthroplasty: a biomechanical validation. J Orthop Res 31(6):991–997CrossRef
26.
Zurück zum Zitat Bensen AS, Jakobsen T, Krarup N (2014) Dual mobility cup reduces dislocation and re-operation when used to treat displaced femoral neck fractures. Int Orthop 38(6):1241–1245CrossRef Bensen AS, Jakobsen T, Krarup N (2014) Dual mobility cup reduces dislocation and re-operation when used to treat displaced femoral neck fractures. Int Orthop 38(6):1241–1245CrossRef
27.
Zurück zum Zitat Hailer NP, Weiss RJ, Stark A, Kärrholm J (2012) The risk of revision due to dislocation after total hip arthroplasty depends on surgical approach, femoral head size, sex, and primary diagnosis. An analysis of 78,098 operations in the Swedish hip arthroplasty register. Acta Orthop 83(5):442–448CrossRef Hailer NP, Weiss RJ, Stark A, Kärrholm J (2012) The risk of revision due to dislocation after total hip arthroplasty depends on surgical approach, femoral head size, sex, and primary diagnosis. An analysis of 78,098 operations in the Swedish hip arthroplasty register. Acta Orthop 83(5):442–448CrossRef
28.
Zurück zum Zitat Marx RG, Wilson SM, Swiontkowski MF (2015) Updating the assignment of levels of evidence. J Bone Joint Surg Am 97(1):1–2CrossRef Marx RG, Wilson SM, Swiontkowski MF (2015) Updating the assignment of levels of evidence. J Bone Joint Surg Am 97(1):1–2CrossRef
29.
Zurück zum Zitat Slim K, Nini E, Forestier D, Kwiatkowski F, Panis Y, Chipponi J (2003) Methodological index for non-randomized studies (minors): development and validation of a new instrument. ANZ J Surg 73(9):712–716CrossRef Slim K, Nini E, Forestier D, Kwiatkowski F, Panis Y, Chipponi J (2003) Methodological index for non-randomized studies (minors): development and validation of a new instrument. ANZ J Surg 73(9):712–716CrossRef
30.
31.
Zurück zum Zitat Charissoux JL, Asloum Y, Marcheix PS (2014) Surgical management of recurrent dislocation after total hip arthroplasty. Orthop Traumatol Surg Res 100(1 Suppl):25–34CrossRef Charissoux JL, Asloum Y, Marcheix PS (2014) Surgical management of recurrent dislocation after total hip arthroplasty. Orthop Traumatol Surg Res 100(1 Suppl):25–34CrossRef
32.
Zurück zum Zitat Parvizi J, Picinic E, Sharkey PF (2008) Revision total hip arthroplasty for instability: surgical techniques and principles. J Bone Joint Surg Am 90(5):1134–1142PubMed Parvizi J, Picinic E, Sharkey PF (2008) Revision total hip arthroplasty for instability: surgical techniques and principles. J Bone Joint Surg Am 90(5):1134–1142PubMed
33.
Zurück zum Zitat Hozo SP, Djulbegovic B, Hozo I (2005) Estimating the mean and variance from the median, range, and the size of a sample. BMC Med Res Methodol 5:13CrossRef Hozo SP, Djulbegovic B, Hozo I (2005) Estimating the mean and variance from the median, range, and the size of a sample. BMC Med Res Methodol 5:13CrossRef
34.
Zurück zum Zitat Higgins JPT, Thompson SG, Deeks JJ, Altman DG (2003) Measuring inconsistency in meta-analyses. BMJ 327:557–560CrossRef Higgins JPT, Thompson SG, Deeks JJ, Altman DG (2003) Measuring inconsistency in meta-analyses. BMJ 327:557–560CrossRef
35.
Zurück zum Zitat Hedges LV, Vevea JL (1998) Fixed- and random-effects models in meta-analysis. Psychol Methods 3(4):486–504CrossRef Hedges LV, Vevea JL (1998) Fixed- and random-effects models in meta-analysis. Psychol Methods 3(4):486–504CrossRef
36.
Zurück zum Zitat Bouchet R, Mercier N, Saragaglia D (2011) Posterior approach and dislocation rate: a 213 total hip replacements case-control study comparing the dual mobility cup with a conventional 28-mm metal head/polyethylene prosthesis. Orthop Traumatol Surg Res 97(1):2–7CrossRef Bouchet R, Mercier N, Saragaglia D (2011) Posterior approach and dislocation rate: a 213 total hip replacements case-control study comparing the dual mobility cup with a conventional 28-mm metal head/polyethylene prosthesis. Orthop Traumatol Surg Res 97(1):2–7CrossRef
37.
Zurück zum Zitat Caton JH, Prudhon JL, Ferreira A, Aslanian T, Verdier R (2014) A comparative and retrospective study of three hundred and twenty primary Charnley type hip replacements with a minimum follow up of ten years to assess whether a dual mobility cup has a decreased dislocation risk. Int Orthop 38(6):1125–1129CrossRef Caton JH, Prudhon JL, Ferreira A, Aslanian T, Verdier R (2014) A comparative and retrospective study of three hundred and twenty primary Charnley type hip replacements with a minimum follow up of ten years to assess whether a dual mobility cup has a decreased dislocation risk. Int Orthop 38(6):1125–1129CrossRef
38.
Zurück zum Zitat Chalmers BP, Perry KI, Hanssen AD, Pagnano MW, Abdel MP (2017) Conversion of hip hemiarthroplasty to total hip arthroplasty utilizing a dual-mobility construct compared with large femoral heads. J Arthroplast 32(10):3071–3075CrossRef Chalmers BP, Perry KI, Hanssen AD, Pagnano MW, Abdel MP (2017) Conversion of hip hemiarthroplasty to total hip arthroplasty utilizing a dual-mobility construct compared with large femoral heads. J Arthroplast 32(10):3071–3075CrossRef
39.
Zurück zum Zitat D'Apuzzo MR, Nevelos J, Yeager A, Westrich GH (2014) Relative head size increase using an anatomic dual mobility hip prosthesis compared to traditional hip arthroplasty: impact on hip stability. J Arthroplast 29(9):1854–1856CrossRef D'Apuzzo MR, Nevelos J, Yeager A, Westrich GH (2014) Relative head size increase using an anatomic dual mobility hip prosthesis compared to traditional hip arthroplasty: impact on hip stability. J Arthroplast 29(9):1854–1856CrossRef
40.
Zurück zum Zitat Epinette JA (2015) Clinical outcomes, survivorship and adverse events with mobile-bearings versus fixed-bearings in hip arthroplasty-a prospective comparative cohort study of 143 ADM versus 130 trident cups at 2 to 6-year follow-up. J Arthroplast 30(2):241–248CrossRef Epinette JA (2015) Clinical outcomes, survivorship and adverse events with mobile-bearings versus fixed-bearings in hip arthroplasty-a prospective comparative cohort study of 143 ADM versus 130 trident cups at 2 to 6-year follow-up. J Arthroplast 30(2):241–248CrossRef
41.
Zurück zum Zitat Gonzalez AI, Bartolone P, Lubbeke A, Dupuis Lozeron E, Peter R, Hoffmeyer P, Christofilopoulos P (2017) Comparison of dual-mobility cup and unipolar cup for prevention of dislocation after revision total hip arthroplasty. Acta Orthop 88(1):18–23CrossRef Gonzalez AI, Bartolone P, Lubbeke A, Dupuis Lozeron E, Peter R, Hoffmeyer P, Christofilopoulos P (2017) Comparison of dual-mobility cup and unipolar cup for prevention of dislocation after revision total hip arthroplasty. Acta Orthop 88(1):18–23CrossRef
42.
Zurück zum Zitat Griffin XL, Parsons N, Achten J, Costa ML (2016) A randomized feasibility study comparing total hip arthroplasty with and without dual mobility acetabular component in the treatment of displaced intracapsular fractures of the proximal femur: the Warwick hip trauma evaluation two: WHiTE two. Bone Joint J 98-B(11):1431–1435CrossRef Griffin XL, Parsons N, Achten J, Costa ML (2016) A randomized feasibility study comparing total hip arthroplasty with and without dual mobility acetabular component in the treatment of displaced intracapsular fractures of the proximal femur: the Warwick hip trauma evaluation two: WHiTE two. Bone Joint J 98-B(11):1431–1435CrossRef
43.
Zurück zum Zitat Hernigou P, Trousselier M, Roubineau F, Bouthors C, Flouzat Lachaniette CH (2016) Dual-mobility or constrained liners are more effective than preoperative bariatric surgery in prevention of THA dislocation. Clin Orthop Relat Res 474(10):2202–2210 Hernigou P, Trousselier M, Roubineau F, Bouthors C, Flouzat Lachaniette CH (2016) Dual-mobility or constrained liners are more effective than preoperative bariatric surgery in prevention of THA dislocation. Clin Orthop Relat Res 474(10):2202–2210
44.
Zurück zum Zitat Hernigou P, Auregan JC, Potage D, Roubineau F, Flouzat Lachaniette CH, Dubory A (2017) Dual-mobility implants prevent hip dislocation following hip revision in obese patients. Int Orthop 41(3):469–473CrossRef Hernigou P, Auregan JC, Potage D, Roubineau F, Flouzat Lachaniette CH, Dubory A (2017) Dual-mobility implants prevent hip dislocation following hip revision in obese patients. Int Orthop 41(3):469–473CrossRef
45.
Zurück zum Zitat Homma Y, Baba T, Kobayashi H, Desroches A, Ochi H, Ozaki Y, Matsumoto M, Yuasa T, Kaneko K (2016) Benefit and risk in short term after total hip arthroplasty by direct anterior approach combined with dual mobility cup. Eur J Orthop Surg Traumatol 26(6):619–624CrossRef Homma Y, Baba T, Kobayashi H, Desroches A, Ochi H, Ozaki Y, Matsumoto M, Yuasa T, Kaneko K (2016) Benefit and risk in short term after total hip arthroplasty by direct anterior approach combined with dual mobility cup. Eur J Orthop Surg Traumatol 26(6):619–624CrossRef
46.
Zurück zum Zitat Jauregui JJ, Pierce TP, Elmallah RK, Cherian JJ, Delanois RE, Mont MA (2016) Dual mobility cups: an effective prosthesis in revision total hip arthroplasties for preventing dislocations. Hip Int 26(1):57–61CrossRef Jauregui JJ, Pierce TP, Elmallah RK, Cherian JJ, Delanois RE, Mont MA (2016) Dual mobility cups: an effective prosthesis in revision total hip arthroplasties for preventing dislocations. Hip Int 26(1):57–61CrossRef
47.
Zurück zum Zitat Perrin A, Saab M, Putman S, Benad K, Drumez E, Chantelot C (2017) The benefit of the systematic revision of the acetabular implant in favor of a dual mobility articulation during the treatment of periprosthetic fractures of the femur: a 49 cases prospective comparative study. Eur J Orthop Surg Traumatol. https://doi.org/10.1007/s00590-017-2037-2 Perrin A, Saab M, Putman S, Benad K, Drumez E, Chantelot C (2017) The benefit of the systematic revision of the acetabular implant in favor of a dual mobility articulation during the treatment of periprosthetic fractures of the femur: a 49 cases prospective comparative study. Eur J Orthop Surg Traumatol. https://​doi.​org/​10.​1007/​s00590-017-2037-2
48.
Zurück zum Zitat Rowan FE, Salvatore AJ, Lange JK, Westrich GH (2017) Dual-mobility vs fixed-bearing total hip arthroplasty in patients under 55 years of age: a single-institution, matched-cohort analysis. J Arthroplast 32(10):3076–3081CrossRef Rowan FE, Salvatore AJ, Lange JK, Westrich GH (2017) Dual-mobility vs fixed-bearing total hip arthroplasty in patients under 55 years of age: a single-institution, matched-cohort analysis. J Arthroplast 32(10):3076–3081CrossRef
49.
Zurück zum Zitat Tarasevicius S, Busevicius M, Robertsson O, Wingstrand H (2010) Dual mobility cup reduces dislocation rate after arthroplasty for femoral neck fracture. BMC Musculoskelet Disord 6(11):175CrossRef Tarasevicius S, Busevicius M, Robertsson O, Wingstrand H (2010) Dual mobility cup reduces dislocation rate after arthroplasty for femoral neck fracture. BMC Musculoskelet Disord 6(11):175CrossRef
50.
Zurück zum Zitat Tarasevicius S, Robertsson O, Dobozinskas P, Wingstrand H (2013) A comparison of outcomes and dislocation rates using dual articulation cups and THA for intracapsular femoral neck fractures. Hip Int 23(1):22–26CrossRef Tarasevicius S, Robertsson O, Dobozinskas P, Wingstrand H (2013) A comparison of outcomes and dislocation rates using dual articulation cups and THA for intracapsular femoral neck fractures. Hip Int 23(1):22–26CrossRef
51.
Zurück zum Zitat Bousquet G, Gazielly DF, Debiesse JL (1985) The ceramic coated cementless total hip arthroplasty. Basic concepts and surgical technique. J Orthop Surg Tech 1:15–28 Bousquet G, Gazielly DF, Debiesse JL (1985) The ceramic coated cementless total hip arthroplasty. Basic concepts and surgical technique. J Orthop Surg Tech 1:15–28
52.
Zurück zum Zitat Howie DW, Holubowycz OT, Middleton R (2012) Large Articulation Study Group. Large femoral heads decrease the incidence of dislocation after total hip arthroplasty: a randomized controlled trial. J Bone Joint Surg [Am] 94-A:1095–1102 Howie DW, Holubowycz OT, Middleton R (2012) Large Articulation Study Group. Large femoral heads decrease the incidence of dislocation after total hip arthroplasty: a randomized controlled trial. J Bone Joint Surg [Am] 94-A:1095–1102
53.
Zurück zum Zitat Malik A, Maheshawari A, Dorr LD (2007) Impingement with total hip replacement. J Bone Joint Surg Am 89:1832–1842 Malik A, Maheshawari A, Dorr LD (2007) Impingement with total hip replacement. J Bone Joint Surg Am 89:1832–1842
54.
Zurück zum Zitat Cooper HJ, Della Valle CJ (2014) Large diameter femoral heads: is bigger always better? Bone Joint J 96B(11 Suppl. A):23–26CrossRef Cooper HJ, Della Valle CJ (2014) Large diameter femoral heads: is bigger always better? Bone Joint J 96B(11 Suppl. A):23–26CrossRef
55.
Zurück zum Zitat Delaunay C, Hamadouche M, Girard J, Duhamel A, So FG (2013) What are the causes for failures of primary hip arthroplasties in France? Clin Orthop Relat Res 471(12):3863–3869CrossRef Delaunay C, Hamadouche M, Girard J, Duhamel A, So FG (2013) What are the causes for failures of primary hip arthroplasties in France? Clin Orthop Relat Res 471(12):3863–3869CrossRef
56.
Zurück zum Zitat Vahedi H, Makhdom AM, Parvizi J (2017) Dual mobility acetabular cup for total hip arthroplasty: use with caution. Expert Rev Med Devices 14(3):237–243CrossRef Vahedi H, Makhdom AM, Parvizi J (2017) Dual mobility acetabular cup for total hip arthroplasty: use with caution. Expert Rev Med Devices 14(3):237–243CrossRef
57.
Zurück zum Zitat Adam P, Farizon F, Fessy MH (2014) Dual mobility retentive acetabular liners and wear: surface analysis of 40 retrieved polyethylene implants. Orthop Traumatol Surg Res 100:85–91CrossRef Adam P, Farizon F, Fessy MH (2014) Dual mobility retentive acetabular liners and wear: surface analysis of 40 retrieved polyethylene implants. Orthop Traumatol Surg Res 100:85–91CrossRef
58.
Zurück zum Zitat D'Apuzzo MR, Koch CN, Esposito CI, Elpers ME, Wright TM, Westrich GH (2016) Assessment of damage on a dual mobility acetabular system. J Arthroplast 31:1828–1835CrossRef D'Apuzzo MR, Koch CN, Esposito CI, Elpers ME, Wright TM, Westrich GH (2016) Assessment of damage on a dual mobility acetabular system. J Arthroplast 31:1828–1835CrossRef
59.
Zurück zum Zitat Vermersch T, Viste A, Desmarchelier R, Fessy MH (2015) Prospective longitudinal study of one hundred patients with total hip arthroplasty using a second-generation cementless dual-mobility cup. Int Orthop 39:2097–2101CrossRef Vermersch T, Viste A, Desmarchelier R, Fessy MH (2015) Prospective longitudinal study of one hundred patients with total hip arthroplasty using a second-generation cementless dual-mobility cup. Int Orthop 39:2097–2101CrossRef
60.
Zurück zum Zitat Banzhof JA, Robbins CE, van der Ven A, Talmo CT, Bono JV (2013) Femoral head dislodgement complicating use of dual mobility prosthesis for recurrent instability. J Arthroplast 28:543.e1–543.e3CrossRef Banzhof JA, Robbins CE, van der Ven A, Talmo CT, Bono JV (2013) Femoral head dislodgement complicating use of dual mobility prosthesis for recurrent instability. J Arthroplast 28:543.e1–543.e3CrossRef
61.
Zurück zum Zitat Odland AN, Sierra RJ (2014) Intraprosthetic dislocation of a contemporary dual-mobility design used during conversion THA. Orthopedics 37:e1124–e1128CrossRef Odland AN, Sierra RJ (2014) Intraprosthetic dislocation of a contemporary dual-mobility design used during conversion THA. Orthopedics 37:e1124–e1128CrossRef
62.
Zurück zum Zitat Barlow BT, McLawhorn AS, Westrich GH (2017) The cost-effectiveness of dual mobility implants for primary total hip arthroplasty: a computer-based cost-utility model. J Bone Joint Surg Am 3 99(9):768–777CrossRef Barlow BT, McLawhorn AS, Westrich GH (2017) The cost-effectiveness of dual mobility implants for primary total hip arthroplasty: a computer-based cost-utility model. J Bone Joint Surg Am 3 99(9):768–777CrossRef
Metadaten
Titel
The efficacy of dual-mobility cup in preventing dislocation after total hip arthroplasty: a systematic review and meta-analysis of comparative studies
verfasst von
Matteo Romagnoli
Alberto Grassi
Giuseppe Gianluca Costa
Lionel E Lazaro
Mirco Lo Presti
Stefano Zaffagnini
Publikationsdatum
21.07.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 5/2019
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-018-4062-0

Weitere Artikel der Ausgabe 5/2019

International Orthopaedics 5/2019 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.