Skip to main content
Erschienen in: Radiological Physics and Technology 3/2019

05.06.2019

The feasibility of contrast-enhanced spectral mammography immediately after contrast-enhanced CT

verfasst von: Nobuko Okada, Fuminari Tatsugami, Mai Sugai, Izumi Okita, Mitsuya Ito, Shoichiro Ohtani, Kouichi Ichimura, Masaki Urashima, Kazuo Awai

Erschienen in: Radiological Physics and Technology | Ausgabe 3/2019

Einloggen, um Zugang zu erhalten

Abstract

Contrast-enhanced spectral mammography (CESM) is a digital mammography method that requires an intravenous injection of iodinated contrast material to detect hypervascular lesions. In patients undergoing evaluation for metastases before breast tumor surgery, a contrast material must be injected for computed tomography (CT) and CESM studies. The purpose of our study was to investigate the feasibility of performing CESM immediately after contrast-enhanced CT, without injecting additional contrast material. We enrolled 77 women with 88 breast carcinomas. Immediately after contrast-enhanced CT, we performed CESM without injecting additional contrast material. The patients were divided into two groups based on the length of the interval between contrast material injection and the start of mammography. In group A (n = 51), it was less, and in group B (n = 26) it was more than 7 min. We measured the tumor gland contrast of each tumor on the CESM images and recorded the tumor opacification on a 4-point visual scale. The mean interval between the start of contrast material injection for CT and the acquisition of mammograms in groups A and B was 5.41 and 10.40 min, respectively. All lesions were detectable on the CESM images. There was no significant difference in the visual evaluation between the two groups (p = 0.21). CESM immediately after contrast-enhanced CT without the injection of additional contrast material is feasible and cost-effective.
Literatur
7.
Zurück zum Zitat Luczynska E, Niemiec J, Hendrick E, Heinze S, Jaszczynski J, Jakubowicz J, et al. Degree of enhancement on contrast enhanced spectral mammography (CESM) and lesion type on mammography (MG): comparison based on histological results. Med Sci Monit Int Med J Exp Clin Res. 2016;22:3886–933. Luczynska E, Niemiec J, Hendrick E, Heinze S, Jaszczynski J, Jakubowicz J, et al. Degree of enhancement on contrast enhanced spectral mammography (CESM) and lesion type on mammography (MG): comparison based on histological results. Med Sci Monit Int Med J Exp Clin Res. 2016;22:3886–933.
14.
Zurück zum Zitat Shiraishi A, Kurosaki Y, Maehara T, Suzuki M, Kurosumi M. Extension of ductal carcinoma in situ: histopathological association with MR imaging and mammography. Magn Reson Med Sci. 2003;2(4):159–63.CrossRefPubMed Shiraishi A, Kurosaki Y, Maehara T, Suzuki M, Kurosumi M. Extension of ductal carcinoma in situ: histopathological association with MR imaging and mammography. Magn Reson Med Sci. 2003;2(4):159–63.CrossRefPubMed
Metadaten
Titel
The feasibility of contrast-enhanced spectral mammography immediately after contrast-enhanced CT
verfasst von
Nobuko Okada
Fuminari Tatsugami
Mai Sugai
Izumi Okita
Mitsuya Ito
Shoichiro Ohtani
Kouichi Ichimura
Masaki Urashima
Kazuo Awai
Publikationsdatum
05.06.2019
Verlag
Springer Singapore
Erschienen in
Radiological Physics and Technology / Ausgabe 3/2019
Print ISSN: 1865-0333
Elektronische ISSN: 1865-0341
DOI
https://doi.org/10.1007/s12194-019-00518-6

Weitere Artikel der Ausgabe 3/2019

Radiological Physics and Technology 3/2019 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.