Skip to main content
Erschienen in: International Orthopaedics 11/2016

23.12.2015 | Original Paper

The focally constrained liner is a reasonable option for revision of unstable total hip arthroplasty

verfasst von: Tatu J. Mäkinen, Simcha G. Fichman, Wael A. Rahman, Tomas Amenabar, Oleg Safir, Allan E. Gross, Paul R. T. Kuzyk

Erschienen in: International Orthopaedics | Ausgabe 11/2016

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Revision surgery for a patient with previous recurrent dislocations or abductor muscle dysfunction has been considered to be a complication-prone procedure regardless of the type of constrained implant used. We investigated the survivorship of a focally constrained acetabular liner used for revision total hip arthroplasty in patients with abductor insufficiency or previous recurrent dislocations.

Methods

We retrospectively reviewed 98 patients in whom a focally constrained acetabular liner was used to treat abductor insufficiency or previous recurrent dislocations. The mean age was 69.4 years (37–92) and 64 of these were females. Previously, the patients had undergone a mean of two (1–5) revisions. The mean follow-up was 38 (12–66) months. Kaplan-Meier survival curves were calculated and Log-rank test was used to test the difference in survivorship between patients with abductor insufficiency and previous dislocations.

Results

Sixteen patients needed a further re-revision for any cause. Thus, the revision-free survivorship was 84.3 % at five years. Five patients suffered a dislocation with a mean of five months post-operatively and were managed with repeat revision. Five patients failed at the implant-host bone interface. Three of these failures occurred after cementing the constrained liner into a pre-existing shell.

Conclusions

The focally constrained liner provided a reasonable option for revision total hip arthroplasty in patients with hip instability. Failures were observed in patients with acetabular osteolysis but seemingly well-fixed component and unrecognized impingement.
Literatur
1.
Zurück zum Zitat Wera GD, Ting NT, Moric M, Paprosky WG, Sporer SM, Della Valle CJ (2012) Classification and management of the unstable total hip arthroplasty. J Arthroplasty 27:710–715CrossRefPubMed Wera GD, Ting NT, Moric M, Paprosky WG, Sporer SM, Della Valle CJ (2012) Classification and management of the unstable total hip arthroplasty. J Arthroplasty 27:710–715CrossRefPubMed
2.
Zurück zum Zitat Opperer M, Lee YY, Nally F, Blanes Perez A, Goudarz-Mehdikhani K, Gonzalez Della Valle A (2015) A critical analysis of radiographic factors in patients who develop dislocation after elective primary total hip arthroplasty. Int Orthop. In press Opperer M, Lee YY, Nally F, Blanes Perez A, Goudarz-Mehdikhani K, Gonzalez Della Valle A (2015) A critical analysis of radiographic factors in patients who develop dislocation after elective primary total hip arthroplasty. Int Orthop. In press
3.
Zurück zum Zitat Khan RJ, Fick D, Alakeson R, Li MG, Nivbrant B, Wood D (2007) The constrained acetabular component for hip instability. J Arthroplasty 22:377–382CrossRefPubMed Khan RJ, Fick D, Alakeson R, Li MG, Nivbrant B, Wood D (2007) The constrained acetabular component for hip instability. J Arthroplasty 22:377–382CrossRefPubMed
4.
Zurück zum Zitat Soong M, Rubash HE, Macaulay W (2004) Dislocation after total hip arthroplasty. J Am Acad Orthop Surg 12:314–321CrossRefPubMed Soong M, Rubash HE, Macaulay W (2004) Dislocation after total hip arthroplasty. J Am Acad Orthop Surg 12:314–321CrossRefPubMed
5.
Zurück zum Zitat Wetters NG, Murray TG, Moric M, Sporer SM, Paprosky WG, Della Valle CJ (2013) Risk factors for dislocation after revision total hip arthroplasty. Clin Orthop Relat Res 471:410–416CrossRefPubMed Wetters NG, Murray TG, Moric M, Sporer SM, Paprosky WG, Della Valle CJ (2013) Risk factors for dislocation after revision total hip arthroplasty. Clin Orthop Relat Res 471:410–416CrossRefPubMed
6.
Zurück zum Zitat Shah SN, Kaye RJ, Kelly NH, Su EP, Padgett DE, Wright TM (2009) Retrieval analysis of failed constrained acetabular liners. J Arthroplasty 24(6 Suppl):54–57CrossRefPubMed Shah SN, Kaye RJ, Kelly NH, Su EP, Padgett DE, Wright TM (2009) Retrieval analysis of failed constrained acetabular liners. J Arthroplasty 24(6 Suppl):54–57CrossRefPubMed
7.
Zurück zum Zitat Yun AG, Padgett D, Pellicci P, Dorr LD (2005) Constrained acetabular liners: mechanisms of failure. J Arthroplasty 20:536–541CrossRefPubMed Yun AG, Padgett D, Pellicci P, Dorr LD (2005) Constrained acetabular liners: mechanisms of failure. J Arthroplasty 20:536–541CrossRefPubMed
8.
Zurück zum Zitat Etienne G, Ragland PS, Mont MA (2005) Use of constrained acetabular liners in total hip arthroplasty. Orthopedics 28:463–469PubMed Etienne G, Ragland PS, Mont MA (2005) Use of constrained acetabular liners in total hip arthroplasty. Orthopedics 28:463–469PubMed
9.
Zurück zum Zitat Anderson MJ, Murray WR, Skinner HB (1994) Constrained acetabular components. J Arthroplasty 9:17–23CrossRefPubMed Anderson MJ, Murray WR, Skinner HB (1994) Constrained acetabular components. J Arthroplasty 9:17–23CrossRefPubMed
10.
Zurück zum Zitat Lombardi AV Jr, Mallory TH, Kraus TJ, Vaughn BK (1991) Preliminary report on the S-ROM constraining acetabular insert: a retrospective clinical experience. Orthopedics 14:297–303PubMed Lombardi AV Jr, Mallory TH, Kraus TJ, Vaughn BK (1991) Preliminary report on the S-ROM constraining acetabular insert: a retrospective clinical experience. Orthopedics 14:297–303PubMed
11.
Zurück zum Zitat Munro JT, Vioreanu MH, Masri BA, Duncan CP (2013) Acetabular liner with focal constraint to prevent dislocation after THA. Clin Orthop Relat Res 471:3883–3890CrossRefPubMedPubMedCentral Munro JT, Vioreanu MH, Masri BA, Duncan CP (2013) Acetabular liner with focal constraint to prevent dislocation after THA. Clin Orthop Relat Res 471:3883–3890CrossRefPubMedPubMedCentral
12.
Zurück zum Zitat Goetz DD, Capello WN, Callaghan JJ, Brown TD, Johnston RC (1998) Salvage of total hip instability with a constrained acetabular component. Clin Orthop Relat Res 355:171–181CrossRef Goetz DD, Capello WN, Callaghan JJ, Brown TD, Johnston RC (1998) Salvage of total hip instability with a constrained acetabular component. Clin Orthop Relat Res 355:171–181CrossRef
13.
Zurück zum Zitat Shapiro GS, Weiland DE, Markel DC, Padgett DE, Sculco TP, Pellicci PM (2003) The use of a constrained acetabular component for recurrent dislocation. J Arthroplasty 18:250–258CrossRefPubMed Shapiro GS, Weiland DE, Markel DC, Padgett DE, Sculco TP, Pellicci PM (2003) The use of a constrained acetabular component for recurrent dislocation. J Arthroplasty 18:250–258CrossRefPubMed
14.
Zurück zum Zitat Della Valle CJ, Chang D, Sporer S, Berger RA, Rosenberg AG, Paprosky WG (2005) High failure rate of a constrained acetabular liner in revision total hip arthroplasty. J Arthroplasty 20(7 Suppl 3):103–107CrossRefPubMed Della Valle CJ, Chang D, Sporer S, Berger RA, Rosenberg AG, Paprosky WG (2005) High failure rate of a constrained acetabular liner in revision total hip arthroplasty. J Arthroplasty 20(7 Suppl 3):103–107CrossRefPubMed
15.
Zurück zum Zitat Berend KR, Lombardi AV Jr, Mallory TH, Adams JB, Russell JH, Groseth KL (2005) The long-term outcome of 755 consecutive constrained acetabular components in total hip arthroplasty examining the successes and failures. J Arthroplasty 20(7 Suppl 3):93–102CrossRefPubMed Berend KR, Lombardi AV Jr, Mallory TH, Adams JB, Russell JH, Groseth KL (2005) The long-term outcome of 755 consecutive constrained acetabular components in total hip arthroplasty examining the successes and failures. J Arthroplasty 20(7 Suppl 3):93–102CrossRefPubMed
16.
Zurück zum Zitat Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am 51:737–755PubMed Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am 51:737–755PubMed
17.
Zurück zum Zitat DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 1976:20–32 DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 1976:20–32
18.
Zurück zum Zitat Guyen O, Lewallen DG, Cabanela ME (2008) Modes of failure of Osteonics constrained tripolar implants: a retrospective analysis of forty-three failed implants. J Bone Joint Surg Am 90:1553–1560CrossRefPubMed Guyen O, Lewallen DG, Cabanela ME (2008) Modes of failure of Osteonics constrained tripolar implants: a retrospective analysis of forty-three failed implants. J Bone Joint Surg Am 90:1553–1560CrossRefPubMed
19.
Zurück zum Zitat Pattyn C, De Haan R, Kloeck A, Van Maele G, De Smet K (2010) Complications encountered with the use of constrained acetabular prostheses in total hip arthroplasty. J Arthroplasty 25:287–294CrossRefPubMed Pattyn C, De Haan R, Kloeck A, Van Maele G, De Smet K (2010) Complications encountered with the use of constrained acetabular prostheses in total hip arthroplasty. J Arthroplasty 25:287–294CrossRefPubMed
20.
Zurück zum Zitat Cooper HJ, Della Valle CJ (2014) Large diameter femoral heads: is bigger always better? Bone Joint J 96-B(11 Suppl A):23–26CrossRefPubMed Cooper HJ, Della Valle CJ (2014) Large diameter femoral heads: is bigger always better? Bone Joint J 96-B(11 Suppl A):23–26CrossRefPubMed
21.
Zurück zum Zitat Levine BR, Della Valle CJ, Deirmengian CA, Breien KM, Weeden SH, Sporer SM, Paprosky WG (2008) The use of a tripolar articulation in revision total hip arthroplasty: a minimum of 24 months’ follow-up. J Arthroplasty 23:1182–1188CrossRefPubMed Levine BR, Della Valle CJ, Deirmengian CA, Breien KM, Weeden SH, Sporer SM, Paprosky WG (2008) The use of a tripolar articulation in revision total hip arthroplasty: a minimum of 24 months’ follow-up. J Arthroplasty 23:1182–1188CrossRefPubMed
22.
Zurück zum Zitat Kosashvili Y, Drexler M, Backstein D, Safir O, Lakstein D, Safir A, Chakravertty R, Dwyer T, Gross A (2014) Dislocation after the first and multiple revision total hip arthroplasty: comparison between acetabulum-only, femur-only and both component revision hip arthroplasty. Can J Surg 57:E15–E18CrossRefPubMedPubMedCentral Kosashvili Y, Drexler M, Backstein D, Safir O, Lakstein D, Safir A, Chakravertty R, Dwyer T, Gross A (2014) Dislocation after the first and multiple revision total hip arthroplasty: comparison between acetabulum-only, femur-only and both component revision hip arthroplasty. Can J Surg 57:E15–E18CrossRefPubMedPubMedCentral
23.
Zurück zum Zitat Plummer DR, Haughom BD, Della Valle CJ (2014) Dual mobility in total hip arthroplasty. Orthop Clin N Am 45:1–8CrossRef Plummer DR, Haughom BD, Della Valle CJ (2014) Dual mobility in total hip arthroplasty. Orthop Clin N Am 45:1–8CrossRef
24.
Zurück zum Zitat Lachiewicz PF, Watters TS (2012) The use of dual-mobility components in total hip arthroplasty. J Am Acad Orthop Surg 20:481–486CrossRefPubMed Lachiewicz PF, Watters TS (2012) The use of dual-mobility components in total hip arthroplasty. J Am Acad Orthop Surg 20:481–486CrossRefPubMed
25.
Zurück zum Zitat Prudhon JL, Steffann F, Ferreira A, Verdier R, Aslanian T, Caton J (2014) Cementless dual-mobility cup in total hip arthroplasty revision. Int Orthop 38:2463–2468CrossRefPubMed Prudhon JL, Steffann F, Ferreira A, Verdier R, Aslanian T, Caton J (2014) Cementless dual-mobility cup in total hip arthroplasty revision. Int Orthop 38:2463–2468CrossRefPubMed
26.
Zurück zum Zitat Wegrzyn J, Tebaa E, Jacquel A, Carret JP, Bejui-Hugues J, Pibarot V (2015) Can dual mobility cups prevent dislocation in all situations after revision total Hip arthroplasty? J Arthroplasty 30:631–640CrossRefPubMed Wegrzyn J, Tebaa E, Jacquel A, Carret JP, Bejui-Hugues J, Pibarot V (2015) Can dual mobility cups prevent dislocation in all situations after revision total Hip arthroplasty? J Arthroplasty 30:631–640CrossRefPubMed
27.
Zurück zum Zitat Hailer NP, Weiss RJ, Stark A, Karrholm J (2012) Dual-mobility cups for revision due to instability are associated with a low rate of re-revisions due to dislocation: 228 patients from the Swedish Hip Arthroplasty Register. Acta Orthop 83:566–571CrossRefPubMedPubMedCentral Hailer NP, Weiss RJ, Stark A, Karrholm J (2012) Dual-mobility cups for revision due to instability are associated with a low rate of re-revisions due to dislocation: 228 patients from the Swedish Hip Arthroplasty Register. Acta Orthop 83:566–571CrossRefPubMedPubMedCentral
28.
Zurück zum Zitat Odak S, Ivory J (2013) Management of abductor mechanism deficiency following total hip replacement. Bone Joint J 95-B:343–347CrossRefPubMed Odak S, Ivory J (2013) Management of abductor mechanism deficiency following total hip replacement. Bone Joint J 95-B:343–347CrossRefPubMed
Metadaten
Titel
The focally constrained liner is a reasonable option for revision of unstable total hip arthroplasty
verfasst von
Tatu J. Mäkinen
Simcha G. Fichman
Wael A. Rahman
Tomas Amenabar
Oleg Safir
Allan E. Gross
Paul R. T. Kuzyk
Publikationsdatum
23.12.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 11/2016
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-015-3082-2

Weitere Artikel der Ausgabe 11/2016

International Orthopaedics 11/2016 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.