Skip to main content
Erschienen in: European Radiology 3/2011

Open Access 01.03.2011 | Editorial

The Holy Grail in diagnostic neuroradiology: 3T or 3D?

verfasst von: Frederik Barkhof, Petra J. W. Pouwels, Mike P. Wattjes

Erschienen in: European Radiology | Ausgabe 3/2011

Einloggen, um Zugang zu erhalten

Abstract

Many technical developments keep occurring in the field of MRI that could benefit image acquisition in the field of diagnostic neuroradiology. While there is much focus on the potential advantages of 3T and higher field strengths, it is often unclear whether these are cosmetic only, or convey clinically relevant diagnostic value. The increased signal-to-noise at 3T is certainly beneficial in different ways particularly for the acquisition of isotropic 3D sequences like FLAIR. Single-slab 3D sequences can now be obtained with multiple contrasts in clinically attainable data acquisition times and could revolutionize MRI to evolve into a fundamentally multi-planar technique, rather similar to what has happened with the introduction of multi-detector row CT.
Literatur
1.
Zurück zum Zitat Lauterbur PC (1973) Image formation by induced local interactions: examples of employing nuclear magnetic resonance. Nature 242:190–191CrossRef Lauterbur PC (1973) Image formation by induced local interactions: examples of employing nuclear magnetic resonance. Nature 242:190–191CrossRef
2.
Zurück zum Zitat Young IR, Hall AS, Pallis CA, Legg NJ, Bydder GM, Steiner RE (1981) Nuclear magnetic resonance imaging of the brain in multiple sclerosis. Lancet 2:1063–1066CrossRefPubMed Young IR, Hall AS, Pallis CA, Legg NJ, Bydder GM, Steiner RE (1981) Nuclear magnetic resonance imaging of the brain in multiple sclerosis. Lancet 2:1063–1066CrossRefPubMed
3.
Zurück zum Zitat Schick F (2005) Whole-body MRI at high field: technical limits and clinical potential. Eur Radiol 15:946–959CrossRefPubMed Schick F (2005) Whole-body MRI at high field: technical limits and clinical potential. Eur Radiol 15:946–959CrossRefPubMed
4.
Zurück zum Zitat Willinek WA, Schild HH (2008) Clinical advantages of 3.0T MRI over 1.5T. Eur J Radiol 65:2–14CrossRefPubMed Willinek WA, Schild HH (2008) Clinical advantages of 3.0T MRI over 1.5T. Eur J Radiol 65:2–14CrossRefPubMed
5.
Zurück zum Zitat Wattjes MP, Lutterbey GG, Harzheim M et al (2006) Higher sensitivity in the detection of inflammatory brain lesions in patients with clinically isolated syndromes suggestive of multiple sclerosis using high field MRI: an intraindividual comparison of 1.5T with 3.0T. Eur Radiol 16:2067–2073CrossRefPubMed Wattjes MP, Lutterbey GG, Harzheim M et al (2006) Higher sensitivity in the detection of inflammatory brain lesions in patients with clinically isolated syndromes suggestive of multiple sclerosis using high field MRI: an intraindividual comparison of 1.5T with 3.0T. Eur Radiol 16:2067–2073CrossRefPubMed
6.
Zurück zum Zitat Bachmann R, Reilmann R, Schwindt W, Kugel H, Heindel W, Krämer S (2006) FLAIR imaging for multiple sclerosis: a comparative MR study at 1.5 and 3.0 Tesla. Eur Radiol 16:915–921CrossRefPubMed Bachmann R, Reilmann R, Schwindt W, Kugel H, Heindel W, Krämer S (2006) FLAIR imaging for multiple sclerosis: a comparative MR study at 1.5 and 3.0 Tesla. Eur Radiol 16:915–921CrossRefPubMed
7.
Zurück zum Zitat Simon B, Schmidt S, Lukas C et al (2010) Improved in vivo detection of cortical lesions in multiple sclerosis using double inversion recovery MR imaging at 3 Tesla. Eur Radiol 20:1675–1683CrossRefPubMed Simon B, Schmidt S, Lukas C et al (2010) Improved in vivo detection of cortical lesions in multiple sclerosis using double inversion recovery MR imaging at 3 Tesla. Eur Radiol 20:1675–1683CrossRefPubMed
8.
Zurück zum Zitat Wattjes MP, Barkhof F (2009) High field MRI in the diagnosis of multiple sclerosis: high field –high yield? Neuroradiology 51:279–292CrossRefPubMed Wattjes MP, Barkhof F (2009) High field MRI in the diagnosis of multiple sclerosis: high field –high yield? Neuroradiology 51:279–292CrossRefPubMed
9.
Zurück zum Zitat Vargas MI, Nguyen D, Viallon M et al (2010) Dynamic MR angiography (MRA) of spinal vascular diseases at 3T. Eur Radiol 20:2491–2495CrossRefPubMed Vargas MI, Nguyen D, Viallon M et al (2010) Dynamic MR angiography (MRA) of spinal vascular diseases at 3T. Eur Radiol 20:2491–2495CrossRefPubMed
10.
Zurück zum Zitat Willinek WA, Born M, Simon B et al (2003) Time-of-flight MA angiography: comparison of 3.0T-imaging and 1.5T-imaging-initial experience. Radiology 229:913–920CrossRefPubMed Willinek WA, Born M, Simon B et al (2003) Time-of-flight MA angiography: comparison of 3.0T-imaging and 1.5T-imaging-initial experience. Radiology 229:913–920CrossRefPubMed
11.
Zurück zum Zitat Willinek WA, Bayer T, Gieseke J et al (2007) High spatial resolution contrast-enhanced MR angiography oft he supraaortal arteries using the quadrature head coil at 3.0T: a feasibility study. Eur Radiol 17:618–625CrossRefPubMed Willinek WA, Bayer T, Gieseke J et al (2007) High spatial resolution contrast-enhanced MR angiography oft he supraaortal arteries using the quadrature head coil at 3.0T: a feasibility study. Eur Radiol 17:618–625CrossRefPubMed
12.
Zurück zum Zitat Kakeda S, Korogi Y, Hiai Y et al (2007) Detection of brain metastasis at 3T: comparison among SE, IR-FSE and 3D-GRE sequences. Eur Radiol 17:2345–2351CrossRefPubMed Kakeda S, Korogi Y, Hiai Y et al (2007) Detection of brain metastasis at 3T: comparison among SE, IR-FSE and 3D-GRE sequences. Eur Radiol 17:2345–2351CrossRefPubMed
13.
Zurück zum Zitat Bink A, Schmitt M, Gaa J, Mugler JP 3rd, Lanfermann H, Zanella FE (2006) Detection of lesions in multiple sclerosis by 2D FLAIR and single-slab 3D FLAIR sequences at 3.0T: initial results. Eur Radiol 16:1104–1110CrossRefPubMed Bink A, Schmitt M, Gaa J, Mugler JP 3rd, Lanfermann H, Zanella FE (2006) Detection of lesions in multiple sclerosis by 2D FLAIR and single-slab 3D FLAIR sequences at 3.0T: initial results. Eur Radiol 16:1104–1110CrossRefPubMed
14.
Zurück zum Zitat Schaafsma JD, Velthuis BK, Majoie CB et al (2010) Intracranial aneurysms treated with coil placement: test characteristics of follow-up MR angiography–multicenter study. Radiology 256:209–218CrossRefPubMed Schaafsma JD, Velthuis BK, Majoie CB et al (2010) Intracranial aneurysms treated with coil placement: test characteristics of follow-up MR angiography–multicenter study. Radiology 256:209–218CrossRefPubMed
15.
Zurück zum Zitat Kamali A, Kramer LA, Butler IJ, Hasan KM (2009) Diffusion tensor tractography of the somatosensory system in the human brainstem: initial findings using high isotropic spatial resolution at 3.0T. Eur Radiol 19:1480–1488CrossRefPubMed Kamali A, Kramer LA, Butler IJ, Hasan KM (2009) Diffusion tensor tractography of the somatosensory system in the human brainstem: initial findings using high isotropic spatial resolution at 3.0T. Eur Radiol 19:1480–1488CrossRefPubMed
16.
Zurück zum Zitat Poser BA, Koopmans PJ, Witzel T, Wald LL, Barth M (2010) Three dimensional echo-planar imaging at 7 Tesla. Neuroimage 51:261–266CrossRefPubMed Poser BA, Koopmans PJ, Witzel T, Wald LL, Barth M (2010) Three dimensional echo-planar imaging at 7 Tesla. Neuroimage 51:261–266CrossRefPubMed
17.
Zurück zum Zitat Tan IL, Pouwels PJ, van Schijndel RA, Adèr HJ, Manoliu RA, Barkhof F (2002) Isotropic 3D fast FLAIR imaging of the brain in multiple sclerosis patients: initial experience. Eur Radiol 12:559–567PubMed Tan IL, Pouwels PJ, van Schijndel RA, Adèr HJ, Manoliu RA, Barkhof F (2002) Isotropic 3D fast FLAIR imaging of the brain in multiple sclerosis patients: initial experience. Eur Radiol 12:559–567PubMed
18.
Zurück zum Zitat Naganawa S, Koshikawa T, Nakamura T et al (2004) Comparison of flow artifacts between 2D-FLAIR and 3D-FLAIR sequences at 3T. Eur Radiol 14:1901–1908PubMed Naganawa S, Koshikawa T, Nakamura T et al (2004) Comparison of flow artifacts between 2D-FLAIR and 3D-FLAIR sequences at 3T. Eur Radiol 14:1901–1908PubMed
19.
Zurück zum Zitat Mugler JP 3rd, Bao S, Mulkern RV et al (2000) Optimized single-slab three-dimensional spin-echo MR imaging of the brain. Radiology 216:891–899PubMed Mugler JP 3rd, Bao S, Mulkern RV et al (2000) Optimized single-slab three-dimensional spin-echo MR imaging of the brain. Radiology 216:891–899PubMed
20.
Zurück zum Zitat Pouwels PJ, Kuijer JP, Mugler JP 3rd, Guttmann CR, Barkhof F (2006) Human gray matter: feasibility of single-slab 3D double inversion-recovery high-spatial-resolution MR imaging. Radiology 241:873–879CrossRefPubMed Pouwels PJ, Kuijer JP, Mugler JP 3rd, Guttmann CR, Barkhof F (2006) Human gray matter: feasibility of single-slab 3D double inversion-recovery high-spatial-resolution MR imaging. Radiology 241:873–879CrossRefPubMed
21.
Zurück zum Zitat Moraal B, Roosendaal SD, Pouwels PJ et al (2008) Multi-contrast, isotropic, single-slab 3D MR imaging in multiple sclerosis. Eur Radiol 18:2311–2320CrossRefPubMed Moraal B, Roosendaal SD, Pouwels PJ et al (2008) Multi-contrast, isotropic, single-slab 3D MR imaging in multiple sclerosis. Eur Radiol 18:2311–2320CrossRefPubMed
22.
Zurück zum Zitat Willemse RB, Pouwels PJ, Barkhof F, Vandertop WP (2010) Localisation of the central sulcus region in glioma patients with three-dimensional fluid-attenuated inversion recovery and volume rendering: comparison with functional and conventional magnetic resonance. Br J Neurosurg. doi:10.3109/02688697.2010.522742 PubMed Willemse RB, Pouwels PJ, Barkhof F, Vandertop WP (2010) Localisation of the central sulcus region in glioma patients with three-dimensional fluid-attenuated inversion recovery and volume rendering: comparison with functional and conventional magnetic resonance. Br J Neurosurg. doi:10.​3109/​02688697.​2010.​522742 PubMed
Metadaten
Titel
The Holy Grail in diagnostic neuroradiology: 3T or 3D?
verfasst von
Frederik Barkhof
Petra J. W. Pouwels
Mike P. Wattjes
Publikationsdatum
01.03.2011
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 3/2011
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-010-2034-x

Weitere Artikel der Ausgabe 3/2011

European Radiology 3/2011 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.