Introduction

In addition to abrasion-induced osteolysis and ensuing instabilities, the polyethylene (PE) abrasion of total hip arthroplasty (THA) inlays can also cause gait instability due to the decentralization of the hip joint. The current literature yields, as yet, insufficient findings whether these two factors are linked directly or indirectly to a higher risk for periprosthetic proximal femoral fractures (PPFF). The aim of our retrospective evaluation is to analyse the impact of PE abrasion on the pathology of PPFF in patients with THA.

Material and methods

The retrospective evaluation comprises all PPFF in patients with THA in the period from 01/2010 up to 12/2016. The study group (SG) included 66 cases (n = 66). The control group (CG) was comprised of patients with asymptomatic THA (n = 66), who were treated by our outpatient department including routine check-ups and X-ray examinations. We used the matched-pair methodology to scale the period of postsurgical care of the CG to the lifetime of the implant up to PPFF in the SG. We included epidemiologic data, radiological femoral head decentralization, osteolysis (Gruen classification), instabilities, acetabular cup position, and implant properties in our analysis. For the SG, we also included intra-operative signs of abrasion.

Findings

The SG showed significantly higher numbers of decentralized THA as signs of inlay erosion with 73% compared to only 41% in the CG (p > 0.001). The SG showed 1 ± 0.68 mm hip joint decentralization as to 0.5 ± 0.59 mm in the CG (p = 0.004). We found significantly more cases of osteolysis in the SG (n = 25) than in the CG (n = 13) (p = 0.003). We found no notable differences in acetabular cup inclination or anteversion as well as cup size. However, differences were significant in femoral head size (SG 32 ± 2.3 mm, CG 36 ± 2.4 mm; p = 0.042) and head material. We found more widespread use of metal femoral heads in the SG than in the CG (SG 1:1, CG 1:21; p = 0.001).

Conclusion

PPFF patients showed significantly higher rates of inlay erosion, resulting in femoral head decentralization and osteolysis. The higher rate of fracture is likely caused by the increasing instability of the implant fixation due to abrasion-induced osteolysis and the associated degradation of bone quality. It is conceivable that the abrasion and decentralization of the THA can also lead to gait instability, and thus, a higher proneness to falls. Gait instability can also be aggravated by increased granulation tissue and effusion due to the inlay abrasion. Although this cannot be substantiated by the investigation. In patients with decentralization of the THA and osteolysis, a radiological follow-up should be performed, and in case of gait instability (femoral head and) inlay replacements should be considered.
Literatur
13.
Zurück zum Zitat Gruen TA, McNeice GM, Amstutz HC. “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979;141:17–27. Gruen TA, McNeice GM, Amstutz HC. “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979;141:17–27.
15.
Zurück zum Zitat Green TR, Fisher J, Matthews JB, Stone MH, Ingham E. Effect of size and dose on bone resorption activity of macrophages by in vitro clinically relevant ultra high molecular weight polyethylene particles. J Biomed Mater Res. 2000;53:490–7.CrossRef Green TR, Fisher J, Matthews JB, Stone MH, Ingham E. Effect of size and dose on bone resorption activity of macrophages by in vitro clinically relevant ultra high molecular weight polyethylene particles. J Biomed Mater Res. 2000;53:490–7.CrossRef
16.
Zurück zum Zitat Green TR, Fisher J, Stone M, Wroblewski BM, Ingham E. Polyethylene particles of a ‘critical size’ are necessary for the induction of cytokines by macrophages in vitro. Biomaterials. 1998;19:2297–302.CrossRef Green TR, Fisher J, Stone M, Wroblewski BM, Ingham E. Polyethylene particles of a ‘critical size’ are necessary for the induction of cytokines by macrophages in vitro. Biomaterials. 1998;19:2297–302.CrossRef
19.
Zurück zum Zitat Clarke IC, Gustafson A. Clinical and hip simulator comparisons of ceramic-on-polyethylene and metal-on-polyethylene wear. Clin Orthop Relat Res. 2000;379:34–40.CrossRef Clarke IC, Gustafson A. Clinical and hip simulator comparisons of ceramic-on-polyethylene and metal-on-polyethylene wear. Clin Orthop Relat Res. 2000;379:34–40.CrossRef
20.
Zurück zum Zitat Hernigou P, Auregan JC, Bastard C, Housset V, Flouzat-Lachaniette CH, Dubory A. Higher prevalence of periprosthetic fractures with ceramic on polyethylene hip bearing compared with ceramic on ceramic on the contralateral side: a forty year experience with hip osteonecrosis. Int Orthop. 2018;42:1457–61. https://doi.org/10.1007/s00264-018-3863-5.CrossRefPubMed Hernigou P, Auregan JC, Bastard C, Housset V, Flouzat-Lachaniette CH, Dubory A. Higher prevalence of periprosthetic fractures with ceramic on polyethylene hip bearing compared with ceramic on ceramic on the contralateral side: a forty year experience with hip osteonecrosis. Int Orthop. 2018;42:1457–61. https://​doi.​org/​10.​1007/​s00264-018-3863-5.CrossRefPubMed
21.
22.
Zurück zum Zitat Graves SE, Davidson DC, de Steiger R, Lewis P, Stoney J, Tomkins A, Vial R, Griffith E, Lorimer M, Liu Y, Stanford T, Cuthbert A, Kelly L, O'Donohue G Harvard 44th Annual Advances in Arthroplasty Course, October 7–10, 2014, Massachusetts Graves SE, Davidson DC, de Steiger R, Lewis P, Stoney J, Tomkins A, Vial R, Griffith E, Lorimer M, Liu Y, Stanford T, Cuthbert A, Kelly L, O'Donohue G Harvard 44th Annual Advances in Arthroplasty Course, October 7–10, 2014, Massachusetts
23.
Zurück zum Zitat Premnath V, Harris WH, Jasty M, Merrill EW. Gamma sterilization of UHMWPE articular implants: an analysis of the oxidation problem ultra high molecular weight poly ethylene. Biomaterials. 1996;17:1741–53.CrossRef Premnath V, Harris WH, Jasty M, Merrill EW. Gamma sterilization of UHMWPE articular implants: an analysis of the oxidation problem ultra high molecular weight poly ethylene. Biomaterials. 1996;17:1741–53.CrossRef
26.
Zurück zum Zitat Maloney WJ, Wadey VMR. Management of acetabular bone loss. Instr Course Lect. 2006;55:279–85.PubMed Maloney WJ, Wadey VMR. Management of acetabular bone loss. Instr Course Lect. 2006;55:279–85.PubMed
Metadaten
Titel
The impact of polyethylene abrasion on the occurrence of periprosthetic proximal femoral fractures in patients with total hip arthroplasty
verfasst von
Dirk Zajonz
Nora Lang
Cathleen Pönick
Melanie Edel
Robert Möbius
Harald Busse
Christoph Josten
Andreas Roth
Johannes K. M. Fakler
Publikationsdatum
13.09.2019
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Trauma and Emergency Surgery / Ausgabe 1/2021
Print ISSN: 1863-9933
Elektronische ISSN: 1863-9941
DOI
https://doi.org/10.1007/s00068-019-01222-1

Weitere Artikel der Ausgabe 1/2021

European Journal of Trauma and Emergency Surgery 1/2021 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.