Abstract

Background

Rapid on-site evaluation (ROSE) improves the adequacy and accuracy of EUS-guided tissue acquisition, although it is not routinely widely available. Evidence suggested that core needles might overcome the absence of ROSE. The aim of this study was to evaluate the influence of ROSE on the adequacy and accuracy of EUS-guided tissue acquisition with core needles in patients with pancreatic solid lesions.

Methods

Patients who underwent EUS-guided tissue acquisition of pancreatic mass lesions were retrospectively identified at three tertiary referral centers and those performed with the core needle were included. Adequacy, defined as the rate of cases in which a tissue specimen for proper examination was achieved, with and without ROSE was the primary outcome measure. The diagnostic accuracy and tissue core acquisition were the secondary outcome measures.

Results

A total of 333 patients with pancreatic solid mass lesions were included in the study; 140 cases sampled with ROSE and 193 cases without ROSE. The adequacy was 92.1 % in the group sampled with ROSE and 88.1 % in the group without ROSE (p = 0.227). In the ROSE group sensitivity, specificity, and accuracy were 90.7, 100 and 92.1 %, respectively. In the group without ROSE, sensitivity, specificity, and accuracy were 87.2, 100, and 88.1 %, respectively. No difference for all these figures was observed between the two groups. The tissue core was available in 61.4 and 53.4 % of cases with and without ROSE, respectively (p = 0.143).

Conclusion

In the absence of ROSE, EUS-based tissue acquisition with Core needle should be considered since it achieves comparable tissue sampling adequacy and accuracy.
Literatur
1.
Zurück zum Zitat Erickson RA, Sayage-Rabie L, Beissner RS (2000) Factors predicting the number of EUS-guided fine-needle passes for diagnosis of pancreatic malignancies. Gastrointest Endosc 51:184–190CrossRefPubMed Erickson RA, Sayage-Rabie L, Beissner RS (2000) Factors predicting the number of EUS-guided fine-needle passes for diagnosis of pancreatic malignancies. Gastrointest Endosc 51:184–190CrossRefPubMed
2.
Zurück zum Zitat Hawes RH (2010) The evolution of endoscopic ultrasound: improved imaging, higher accuracy for fine needle aspiration and the reality of endoscopic ultrasound-guided interventions. Curr Opin Gastroenterol 26:436–444PubMed Hawes RH (2010) The evolution of endoscopic ultrasound: improved imaging, higher accuracy for fine needle aspiration and the reality of endoscopic ultrasound-guided interventions. Curr Opin Gastroenterol 26:436–444PubMed
3.
Zurück zum Zitat Hucl T, Wee E, Anuradha S, Gupta R et al (2013) Feasibility and efficiency of a new 22G core needle: a prospective comparison study. Endoscopy 45(10):792–798CrossRefPubMed Hucl T, Wee E, Anuradha S, Gupta R et al (2013) Feasibility and efficiency of a new 22G core needle: a prospective comparison study. Endoscopy 45(10):792–798CrossRefPubMed
4.
Zurück zum Zitat Iglesias-Garcia J, Poley JW, Larghi A et al (2011) Feasibility and yield of a new EUS histology needle: results from a multicenter, pooled, cohort study. Gastrointest Endosc 73(6):1189–1196CrossRefPubMed Iglesias-Garcia J, Poley JW, Larghi A et al (2011) Feasibility and yield of a new EUS histology needle: results from a multicenter, pooled, cohort study. Gastrointest Endosc 73(6):1189–1196CrossRefPubMed
5.
Zurück zum Zitat Larghi A, Iglesias-Garcia J, Poley JW et al (2013) Feasibility and yield of a novel 22-gauge histology EUS needle in patients with pancreatic masses: a multicenter prospective cohort study. Surg Endosc 27(10):3733–3738CrossRefPubMed Larghi A, Iglesias-Garcia J, Poley JW et al (2013) Feasibility and yield of a novel 22-gauge histology EUS needle in patients with pancreatic masses: a multicenter prospective cohort study. Surg Endosc 27(10):3733–3738CrossRefPubMed
6.
Zurück zum Zitat Bang JY, Hebert-Magee S, Trevino J et al (2012) Randomized trial comparing the 22-gauge aspiration and 22-gauge biopsy needle for EUS-guided sampling of solid pancreatic mass lesions. Gastrointest Endosc 76:321–327CrossRefPubMedPubMedCentral Bang JY, Hebert-Magee S, Trevino J et al (2012) Randomized trial comparing the 22-gauge aspiration and 22-gauge biopsy needle for EUS-guided sampling of solid pancreatic mass lesions. Gastrointest Endosc 76:321–327CrossRefPubMedPubMedCentral
7.
Zurück zum Zitat Ashida R, Yasukawa S, Yanagisawa A et al (2014) Prospective multicenter randomized controlled trial of histological diagnostic yield comparing 25G EUS-FNA needles with and without a core trap in patients with solid pancreatic masses. Gastrointest Endosc 79(5s):AB111CrossRef Ashida R, Yasukawa S, Yanagisawa A et al (2014) Prospective multicenter randomized controlled trial of histological diagnostic yield comparing 25G EUS-FNA needles with and without a core trap in patients with solid pancreatic masses. Gastrointest Endosc 79(5s):AB111CrossRef
8.
Zurück zum Zitat Wani S, Muthusamy R, Komanduri S et al (2014) Fine needle biopsy (FNB) is more cost-effective than fine needle aspiration (FNA) for endoscopic ultrasound guided tissue sampling: an economic analysis. Gastrointest Endosc 79(5S):AB189CrossRef Wani S, Muthusamy R, Komanduri S et al (2014) Fine needle biopsy (FNB) is more cost-effective than fine needle aspiration (FNA) for endoscopic ultrasound guided tissue sampling: an economic analysis. Gastrointest Endosc 79(5S):AB189CrossRef
9.
Zurück zum Zitat Fabbri C, Luigiano C, Maimone A et al (2015) Endoscopic ultrasound-guided fine-needle biopsy of small solid pancreatic lesions using a 22-gauge needle with side fenestration. Surg Endosc 29(6):1586–1590CrossRefPubMed Fabbri C, Luigiano C, Maimone A et al (2015) Endoscopic ultrasound-guided fine-needle biopsy of small solid pancreatic lesions using a 22-gauge needle with side fenestration. Surg Endosc 29(6):1586–1590CrossRefPubMed
10.
Zurück zum Zitat Habibzadeh F, Yadollahie M (2013) Number needed to misdiagnose: a measure of diagnostic test effectiveness. Epidemiology 24(1):170CrossRefPubMed Habibzadeh F, Yadollahie M (2013) Number needed to misdiagnose: a measure of diagnostic test effectiveness. Epidemiology 24(1):170CrossRefPubMed
12.
Zurück zum Zitat Hewitt MJ, McPhail MJ, Possamai L et al (2012) EUS-guided FNA for diagnosis of solid pancreatic neoplasms: a meta-analysis. Gastrointest Endosc 75:319–331CrossRefPubMed Hewitt MJ, McPhail MJ, Possamai L et al (2012) EUS-guided FNA for diagnosis of solid pancreatic neoplasms: a meta-analysis. Gastrointest Endosc 75:319–331CrossRefPubMed
13.
Zurück zum Zitat Hébert-Magee S, Bae S, Varadarajulu S et al (2013) The presence of a cytopathologist increases the diagnostic accuracy of endoscopic ultrasound-guided fine needle aspiration cytology for pancreatic adenocarcinoma: a meta-analysis. Cytopathology 24(3):159–171CrossRefPubMedPubMedCentral Hébert-Magee S, Bae S, Varadarajulu S et al (2013) The presence of a cytopathologist increases the diagnostic accuracy of endoscopic ultrasound-guided fine needle aspiration cytology for pancreatic adenocarcinoma: a meta-analysis. Cytopathology 24(3):159–171CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat Schmidt RL, Witt BL, Matynia AP et al (2013) Rapid on-site evaluation increases endoscopic ultrasound-guided fine-needle aspiration adequacy for pancreatic lesions. Dig Dis Sci 58:872–882CrossRefPubMed Schmidt RL, Witt BL, Matynia AP et al (2013) Rapid on-site evaluation increases endoscopic ultrasound-guided fine-needle aspiration adequacy for pancreatic lesions. Dig Dis Sci 58:872–882CrossRefPubMed
15.
Zurück zum Zitat Wani S, Muthusamy VR, Komanduri S (2014) EUS-guided tissue acquisition: an evidence-based approach (with videos). Gastrointest Endosc 80:939–959CrossRefPubMed Wani S, Muthusamy VR, Komanduri S (2014) EUS-guided tissue acquisition: an evidence-based approach (with videos). Gastrointest Endosc 80:939–959CrossRefPubMed
16.
Zurück zum Zitat Jhala NC, Jhala DN, Chieng DC et al (2003) Endoscopic ultrasound-guided fine-needle aspiration. A cytopathologist’s perspective. Am J Clin Pathol 120:351–367CrossRefPubMed Jhala NC, Jhala DN, Chieng DC et al (2003) Endoscopic ultrasound-guided fine-needle aspiration. A cytopathologist’s perspective. Am J Clin Pathol 120:351–367CrossRefPubMed
17.
Zurück zum Zitat Larghi A, Eguia V, Hassan C et al (2014) Economic crisis: the right time to widen endoscopic ultrasound utilization. Endoscopy 46:80–81PubMed Larghi A, Eguia V, Hassan C et al (2014) Economic crisis: the right time to widen endoscopic ultrasound utilization. Endoscopy 46:80–81PubMed
18.
Zurück zum Zitat Kalaitzakis E, Panos M, Sadik R et al (2009) Clinicians’ attitudes towards endoscopic ultrasound: a survey of four European countries. Scand J Gastroenterol 44:100–107CrossRefPubMed Kalaitzakis E, Panos M, Sadik R et al (2009) Clinicians’ attitudes towards endoscopic ultrasound: a survey of four European countries. Scand J Gastroenterol 44:100–107CrossRefPubMed
19.
Zurück zum Zitat Dumonceau JM, Koessler T, van Hooft JE, Fockens P (2012) Endoscopic ultrasonography-guided fine needle aspiration: relatively low sensitivity in the endosonographer population. World J Gastroenterol 18(19):2357–2363CrossRefPubMedPubMedCentral Dumonceau JM, Koessler T, van Hooft JE, Fockens P (2012) Endoscopic ultrasonography-guided fine needle aspiration: relatively low sensitivity in the endosonographer population. World J Gastroenterol 18(19):2357–2363CrossRefPubMedPubMedCentral
20.
Zurück zum Zitat Lee YN, Moon JH, Kim HK et al (2014) Core biopsy needle versus standard aspiration needle for endoscopic ultrasound-guided sampling of solid pancreatic masses: a randomized parallel-group study. Endoscopy 46:1056–1062CrossRefPubMed Lee YN, Moon JH, Kim HK et al (2014) Core biopsy needle versus standard aspiration needle for endoscopic ultrasound-guided sampling of solid pancreatic masses: a randomized parallel-group study. Endoscopy 46:1056–1062CrossRefPubMed
21.
Zurück zum Zitat Vanbiervliet G, Napoleon B, Saint Paul MC et al (2014) Core needle versus standard needle for endoscopic ultrasound-guided biopsy of solid pancreatic masses: a randomized crossover study. Endoscopy 46:1063–1070CrossRefPubMed Vanbiervliet G, Napoleon B, Saint Paul MC et al (2014) Core needle versus standard needle for endoscopic ultrasound-guided biopsy of solid pancreatic masses: a randomized crossover study. Endoscopy 46:1063–1070CrossRefPubMed
22.
Metadaten
Titel
The presence of rapid on-site evaluation did not increase the adequacy and diagnostic accuracy of endoscopic ultrasound-guided tissue acquisition of solid pancreatic lesions with core needle
verfasst von
Carlo Fabbri
Lorenzo Fuccio
Adele Fornelli
Filippo Antonini
Rosa Liotta
Leonardo Frazzoni
Alberto Larghi
Antonella Maimone
Silvia Paggi
Paolo Gusella
Luca Barresi
Anna Maria Polifemo
Elio Iovine
Giampiero Macarri
Vincenzo Cennamo
Ilaria Tarantino
Publikationsdatum
18.05.2016
Verlag
Springer US
Erschienen in
Surgical Endoscopy / Ausgabe 1/2017
Print ISSN: 0930-2794
Elektronische ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-016-4960-4

Weitere Artikel der Ausgabe 1/2017

Surgical Endoscopy 1/2017 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

CME: 2 Punkte

Prof. Dr. med. Gregor Antoniadis Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

CME: 2 Punkte

Dr. med. Benjamin Meyknecht, PD Dr. med. Oliver Pieske Das Webinar S2e-Leitlinie „Distale Radiusfraktur“ beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

CME: 2 Punkte

Dr. med. Mihailo Andric
Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.