Skip to main content
Erschienen in: Pediatric Cardiology 4/2018

01.02.2018 | Original Article

The Ratio Fallacy, with Special Reference to the Cardiac Index

verfasst von: Julien I. E. Hoffman

Erschienen in: Pediatric Cardiology | Ausgabe 4/2018

Einloggen, um Zugang zu erhalten

Abstract

When comparing cardiac outputs in children of different sizes, or deciding on the normality of these outputs, we often convert the absolute output to the output per m2 body surface area—the cardiac index. For small infants, this leads to potentially large errors. The best way to evaluate these outputs is to determine their z values.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Henry WL, Ware J, Gardin JM, Hepner SI, McKay J, Weiner M (1978) Echocardiographic measurements in normal subjects. Growth-related changes that occur between infancy and early adulthood. Circulation 57:278–285CrossRefPubMed Henry WL, Ware J, Gardin JM, Hepner SI, McKay J, Weiner M (1978) Echocardiographic measurements in normal subjects. Growth-related changes that occur between infancy and early adulthood. Circulation 57:278–285CrossRefPubMed
2.
Zurück zum Zitat Rogé CL, Silverman NH, Hart PA, Ray RM (1978) Cardiac structure growth pattern determined by echocardiography. Circulation 57:285–290CrossRefPubMed Rogé CL, Silverman NH, Hart PA, Ray RM (1978) Cardiac structure growth pattern determined by echocardiography. Circulation 57:285–290CrossRefPubMed
3.
Zurück zum Zitat Dallaire F, Bigras JL, Prsa M, Dahdah N (2015) Bias related to body mass index in pediatric echocardiographic Z scores. Pediatr Cardiol 36:667–676CrossRefPubMed Dallaire F, Bigras JL, Prsa M, Dahdah N (2015) Bias related to body mass index in pediatric echocardiographic Z scores. Pediatr Cardiol 36:667–676CrossRefPubMed
4.
Zurück zum Zitat Dallaire F, Bigras JL, Prsa M, Dahdah N (2015) Erratum to: Bias related to body mass index in pediatric echocardiographic Z scores. Pediatr Cardiol 36:1316CrossRefPubMed Dallaire F, Bigras JL, Prsa M, Dahdah N (2015) Erratum to: Bias related to body mass index in pediatric echocardiographic Z scores. Pediatr Cardiol 36:1316CrossRefPubMed
6.
Zurück zum Zitat du Bois D, du Bois EF (1916) A formula to estimate the approximate surface area if height and weight be known. Arch Int Med 17:863–871CrossRef du Bois D, du Bois EF (1916) A formula to estimate the approximate surface area if height and weight be known. Arch Int Med 17:863–871CrossRef
7.
Zurück zum Zitat Sluysmans T, Colan SD (2005) Theoretical and empirical derivation of cardiovascular allometric relationships in children. J Appl Physiol 99:445–457CrossRefPubMed Sluysmans T, Colan SD (2005) Theoretical and empirical derivation of cardiovascular allometric relationships in children. J Appl Physiol 99:445–457CrossRefPubMed
8.
Zurück zum Zitat Haycock GB, Schwartz GJ, Wisotsky DH (1978) Geometric method for measuring body surface area: a height-weight formula validated in infants, children, and adults. J Pediatr 93:62–66CrossRefPubMed Haycock GB, Schwartz GJ, Wisotsky DH (1978) Geometric method for measuring body surface area: a height-weight formula validated in infants, children, and adults. J Pediatr 93:62–66CrossRefPubMed
9.
Zurück zum Zitat Tanner JM (1949) Fallacy of per-weight and per-surface area standards, and their relation to spurious correlation. J Appl Physiol 2:1–15CrossRefPubMed Tanner JM (1949) Fallacy of per-weight and per-surface area standards, and their relation to spurious correlation. J Appl Physiol 2:1–15CrossRefPubMed
11.
Zurück zum Zitat Reeves JT, Grover RF, Filley GF, Blount SG Jr (1961) Cardiac output in normal resting man. J Appl Physiol 16:276–278CrossRefPubMed Reeves JT, Grover RF, Filley GF, Blount SG Jr (1961) Cardiac output in normal resting man. J Appl Physiol 16:276–278CrossRefPubMed
12.
Zurück zum Zitat Sproul A, Simpson E (1964) Stroke volume and related hemodynamic data in normal children. Pediatrics 33:912–918PubMed Sproul A, Simpson E (1964) Stroke volume and related hemodynamic data in normal children. Pediatrics 33:912–918PubMed
13.
Zurück zum Zitat Cayler GG, Rudolph AM, Nadas AS (1963) Systemic blood flow in infants and children with and without heart disease. Pediatrics 32:186–201PubMed Cayler GG, Rudolph AM, Nadas AS (1963) Systemic blood flow in infants and children with and without heart disease. Pediatrics 32:186–201PubMed
15.
Zurück zum Zitat Carlsson M, Andersson R, Bloch KM, Steding-Ehrenborg K, Mosen H, Stahlberg F, Ekmehag B, Arheden H (2012) Cardiac output and cardiac index measured with cardiovascular magnetic resonance in healthy subjects, elite athletes and patients with congestive heart failure. J Cardiovasc Magn Reson 14:51CrossRefPubMedPubMedCentral Carlsson M, Andersson R, Bloch KM, Steding-Ehrenborg K, Mosen H, Stahlberg F, Ekmehag B, Arheden H (2012) Cardiac output and cardiac index measured with cardiovascular magnetic resonance in healthy subjects, elite athletes and patients with congestive heart failure. J Cardiovasc Magn Reson 14:51CrossRefPubMedPubMedCentral
16.
Zurück zum Zitat de Simone G, Devereux RB, Daniels SR, Mureddu G, Roman MJ, Kimball TR, Greco R, Witt S, Contaldo F (1997) Stroke volume and cardiac output in normotensive children and adults. Assessment of relations with body size and impact of overweight. Circulation 95:1837–1843CrossRefPubMed de Simone G, Devereux RB, Daniels SR, Mureddu G, Roman MJ, Kimball TR, Greco R, Witt S, Contaldo F (1997) Stroke volume and cardiac output in normotensive children and adults. Assessment of relations with body size and impact of overweight. Circulation 95:1837–1843CrossRefPubMed
17.
Zurück zum Zitat Alverson DC, Eldridge M, Dillon T, Yabek SM, Berman W Jr (1982) Noninvasive pulsed Doppler determination of cardiac output in neonates and children. J Pediatr 101:46–50CrossRefPubMed Alverson DC, Eldridge M, Dillon T, Yabek SM, Berman W Jr (1982) Noninvasive pulsed Doppler determination of cardiac output in neonates and children. J Pediatr 101:46–50CrossRefPubMed
18.
Zurück zum Zitat Emmanouilides GC, Moss AJ, Monset-Couchard M, Marcano BA, Rzeznic B (1970) Cardiac output in newborn infants. Biol Neonate 15:186–197CrossRefPubMed Emmanouilides GC, Moss AJ, Monset-Couchard M, Marcano BA, Rzeznic B (1970) Cardiac output in newborn infants. Biol Neonate 15:186–197CrossRefPubMed
19.
Zurück zum Zitat Mellander M, Sabel KG, Caidahl K, Solymar L, Eriksson B (1987) Doppler determination of cardiac output in infants and children: comparison with simultaneous thermodilution. Pediatr Cardiol 8:241–246CrossRefPubMed Mellander M, Sabel KG, Caidahl K, Solymar L, Eriksson B (1987) Doppler determination of cardiac output in infants and children: comparison with simultaneous thermodilution. Pediatr Cardiol 8:241–246CrossRefPubMed
20.
Zurück zum Zitat Walther FJ, Siassi B, Ramadan NA, Ananda AK, Wu PY (1985) Pulsed Doppler determinations of cardiac output in neonates: normal standards for clinical use. Pediatrics 76:829–833PubMed Walther FJ, Siassi B, Ramadan NA, Ananda AK, Wu PY (1985) Pulsed Doppler determinations of cardiac output in neonates: normal standards for clinical use. Pediatrics 76:829–833PubMed
21.
Zurück zum Zitat Delanaye P, Mariat C, Cavalier E, Krzesinski JM (2009) Errors induced by indexing glomerular filtration rate for body surface area: reductio ad absurdum. Nephrol Dial Transplant 24:3593–3596CrossRefPubMed Delanaye P, Mariat C, Cavalier E, Krzesinski JM (2009) Errors induced by indexing glomerular filtration rate for body surface area: reductio ad absurdum. Nephrol Dial Transplant 24:3593–3596CrossRefPubMed
22.
Zurück zum Zitat Piepsz A, Tondeur M, Ham H (2008) Escaping the correction for body surface area when calculating glomerular filtration rate in children. Eur J Nucl Med Mol Imaging 35:1669–1672CrossRefPubMed Piepsz A, Tondeur M, Ham H (2008) Escaping the correction for body surface area when calculating glomerular filtration rate in children. Eur J Nucl Med Mol Imaging 35:1669–1672CrossRefPubMed
23.
Zurück zum Zitat Krovetz LJ, McLoughlin TG, Mitchell MB, Schiebler GL (1967) Hemodynamic findings in normal children. Pediatr Res 1:122–130CrossRefPubMed Krovetz LJ, McLoughlin TG, Mitchell MB, Schiebler GL (1967) Hemodynamic findings in normal children. Pediatr Res 1:122–130CrossRefPubMed
24.
Zurück zum Zitat Skimming JW, Cassin S, Nichols WW (1997) Calculating vascular resistances. Clin Cardiol 20:805–808CrossRefPubMed Skimming JW, Cassin S, Nichols WW (1997) Calculating vascular resistances. Clin Cardiol 20:805–808CrossRefPubMed
Metadaten
Titel
The Ratio Fallacy, with Special Reference to the Cardiac Index
verfasst von
Julien I. E. Hoffman
Publikationsdatum
01.02.2018
Verlag
Springer US
Erschienen in
Pediatric Cardiology / Ausgabe 4/2018
Print ISSN: 0172-0643
Elektronische ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-018-1823-x

Weitere Artikel der Ausgabe 4/2018

Pediatric Cardiology 4/2018 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.