Skip to main content
Erschienen in: Oral and Maxillofacial Surgery 2/2020

09.03.2020 | Original Article

The use of optical scanner for the fabrication of maxillary obturator prostheses

verfasst von: Matteo Brucoli, Paolo Boffano, Andrea Pezzana, Chiara Corio, Arnaldo Benech

Erschienen in: Oral and Maxillofacial Surgery | Ausgabe 2/2020

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Maxillectomy following tumors or, more rarely, traumatic injuries may result in maxillary defects that may determine physical dysfunctions and functional impairment of speech and swallowing. The aim of our study was to present our experience in the management of post-maxillectomy patients by the use of obturator prostheses that were obtained by 3D digital casts via an intraoral scanner.

Methods

Patients with maxillary defects following maxillary and/or palatal resection or maxillary traumatic avulsion were selected for this clinical study between 2015 and 2018. Five to 6 months after surgery, a definitive obturator prosthesis was fabricated thanks to an intraoral scanner. The following parameters of clinical outcome were considered: the absence of fluid leakage, the recovery of phonation, the recovery of swallowing, and personal satisfaction.

Results

Twenty-eight patients (20 males, 8 females) fulfilled the inclusion criteria and were included in the study. Most patients had a maxillary and/or palatal defect because of a malignant tumor. On the whole, 93% of patients reported a complete absence of fluid leakage between maxillary sinuses or nasal fossa and oral cavity; most patients reported a good or complete recovery of phonation and swallowing.

Conclusions

Digital technology for the fabrication of maxillary obturator prosthesis may be effective and useful. The reduced laboratory working time, the avoidance of the risk of aspiration of impression materials, and the overcome of the difficulties associated with whole tissue undercut impression are just some of the most important advantages that have been encountered thanks to this promising technology.
Literatur
1.
Zurück zum Zitat Kreeft AM, Krap M, Wismeijer D, Speksnijder CM, Smeele LE, Bosch SD, Muijen MS, Balm AJ (2012) Oral function after maxillectomy and reconstruction with an obturator. Int J Oral Maxillofac Surg 41(11):1387–1392CrossRef Kreeft AM, Krap M, Wismeijer D, Speksnijder CM, Smeele LE, Bosch SD, Muijen MS, Balm AJ (2012) Oral function after maxillectomy and reconstruction with an obturator. Int J Oral Maxillofac Surg 41(11):1387–1392CrossRef
2.
Zurück zum Zitat Dos Santos DM, de Caxias FP, Bitencourt SB, Turcio KH, Pesqueira AA, Goiato MC (2018) Oral rehabilitation of patients after maxillectomy. A systematic review. Br J Oral Maxillofac Surg 56(4):256–266CrossRef Dos Santos DM, de Caxias FP, Bitencourt SB, Turcio KH, Pesqueira AA, Goiato MC (2018) Oral rehabilitation of patients after maxillectomy. A systematic review. Br J Oral Maxillofac Surg 56(4):256–266CrossRef
3.
Zurück zum Zitat Noh K, Pae A, Lee JW, Kwon YD (2016) Fabricating a tooth- and implant-supported maxillary obturator for a patient after maxillectomy with computer-guided surgery and CAD/CAM technology: a clinical report. J Prosthet Dent 115(5):637–642CrossRef Noh K, Pae A, Lee JW, Kwon YD (2016) Fabricating a tooth- and implant-supported maxillary obturator for a patient after maxillectomy with computer-guided surgery and CAD/CAM technology: a clinical report. J Prosthet Dent 115(5):637–642CrossRef
4.
Zurück zum Zitat Jiang FF, Hou Y, Lu L, Ding XX, Li W, Yan AH (2015) Functional evaluation of a CAD/CAM prosthesis for immediate defect repair after total maxillectomy: a case series of 18 patients with maxillary sinus cancer. J Esthet Restor Dent 27(Suppl 1):S80–S89CrossRef Jiang FF, Hou Y, Lu L, Ding XX, Li W, Yan AH (2015) Functional evaluation of a CAD/CAM prosthesis for immediate defect repair after total maxillectomy: a case series of 18 patients with maxillary sinus cancer. J Esthet Restor Dent 27(Suppl 1):S80–S89CrossRef
5.
Zurück zum Zitat Ting-Shu S, Jian S (2015) Intraoral digital impression technique: a review. J Prosthodont 24(4):313–321CrossRef Ting-Shu S, Jian S (2015) Intraoral digital impression technique: a review. J Prosthodont 24(4):313–321CrossRef
6.
Zurück zum Zitat Soltanzadeh P, Su JM, Habibabadi SR, Kattadiyil MT (2019) Obturator fabrication incorporating computer-aided design and 3-dimensional printing technology: a clinical report. J Prosthet Dent 121(4):694–697CrossRef Soltanzadeh P, Su JM, Habibabadi SR, Kattadiyil MT (2019) Obturator fabrication incorporating computer-aided design and 3-dimensional printing technology: a clinical report. J Prosthet Dent 121(4):694–697CrossRef
7.
Zurück zum Zitat Ye H, Ma Q, Hou Y, Li M, Zhou Y (2017) Generation and evaluation of 3D digital casts of maxillary defects based on multisource data registration: a pilot clinical study. J Prosthet Dent 118(6):790–795CrossRef Ye H, Ma Q, Hou Y, Li M, Zhou Y (2017) Generation and evaluation of 3D digital casts of maxillary defects based on multisource data registration: a pilot clinical study. J Prosthet Dent 118(6):790–795CrossRef
8.
Zurück zum Zitat Kattadiyil MT, Mursic Z, AlRumaih H, Goodacre CJ (2014) Intraoral scanning of hard and soft tissues for partial removable dental prosthesis fabrication. J Prosthet Dent 112(3):444–448CrossRef Kattadiyil MT, Mursic Z, AlRumaih H, Goodacre CJ (2014) Intraoral scanning of hard and soft tissues for partial removable dental prosthesis fabrication. J Prosthet Dent 112(3):444–448CrossRef
Metadaten
Titel
The use of optical scanner for the fabrication of maxillary obturator prostheses
verfasst von
Matteo Brucoli
Paolo Boffano
Andrea Pezzana
Chiara Corio
Arnaldo Benech
Publikationsdatum
09.03.2020
Verlag
Springer Berlin Heidelberg
Erschienen in
Oral and Maxillofacial Surgery / Ausgabe 2/2020
Print ISSN: 1865-1550
Elektronische ISSN: 1865-1569
DOI
https://doi.org/10.1007/s10006-020-00836-9

Weitere Artikel der Ausgabe 2/2020

Oral and Maxillofacial Surgery 2/2020 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.