Abstract

We prospectively compared the utility and precision of preoperative templating performed in printed films (analogue) with that performed on digital radiographs (digital) in 69 patients undergoing primary total hip replacement. Five patients were excluded when misplacement of the marker resulted in a magnification error greater that 10%; in the remaining patients (64 hips), the cup size was within ± one size in 62 (97%) of the analogue and 52 (81%) of the digital (p = 0.01) plans. The stem size was within ± one size in 63 (98%) of the analogue and 60 (94%) of the digital (p = 0.39) plans. The distance from the proximal corner of the lesser trochanter to the center of the prosthetic head (LTCD) in the analogue differed by 5 mm or more from the digital plan in nine cases (14%). Analogue preoperative planning yielded more predictable results than digital planning, particularly in terms of acetabular component size and LTCD that dictates limb lengthening-shortening. The sources of error were not clearly explained by variations in magnification. Inconsistent positioning of the magnification marker may jeopardise the safe implementation of digital templating.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Bono JV (2004) Digital templating in total hip arthroplasty. J Bone Jt Surg Am 86-A(Suppl 2):118–122 Bono JV (2004) Digital templating in total hip arthroplasty. J Bone Jt Surg Am 86-A(Suppl 2):118–122
2.
Zurück zum Zitat Capone A, Salvati EA (1993) L’impianto dell’artroprotesi di anca in soggetti con coxartrosi secondaria a displasia. Considerazioni teoriche e chirurgiche. Gion Itali Ortop Traumatol 19:479–494 Capone A, Salvati EA (1993) L’impianto dell’artroprotesi di anca in soggetti con coxartrosi secondaria a displasia. Considerazioni teoriche e chirurgiche. Gion Itali Ortop Traumatol 19:479–494
3.
Zurück zum Zitat Carter LW, Stovall DO, Young TR (1995) Determination of accuracy of preoperative templating of noncemented femoral prostheses. J Arthroplasty 10:507–513PubMed Carter LW, Stovall DO, Young TR (1995) Determination of accuracy of preoperative templating of noncemented femoral prostheses. J Arthroplasty 10:507–513PubMed
4.
Zurück zum Zitat Clarke IC, Gruen T, Matos M, Amstutz HC (1976) Improved methods for quantitative radiographic evaluation with particular reference to total-hip arthroplasty. Clin Orthop Relat Res 83–91 Clarke IC, Gruen T, Matos M, Amstutz HC (1976) Improved methods for quantitative radiographic evaluation with particular reference to total-hip arthroplasty. Clin Orthop Relat Res 83–91
5.
Zurück zum Zitat Eggli S, Pisan M, Muller ME (1998) The value of preoperative planning for total hip arthroplasty. J Bone Jt Surg Br 80:382–390CrossRef Eggli S, Pisan M, Muller ME (1998) The value of preoperative planning for total hip arthroplasty. J Bone Jt Surg Br 80:382–390CrossRef
6.
Zurück zum Zitat Gonzalez Della Valle A, Comba F, Zoppi A, Salvati EA (2006) Favourable mid-term results of the VerSys CT polished cemented femoral stem for total hip arthroplasty. Int Orthop 30:381–386PubMedCrossRef Gonzalez Della Valle A, Comba F, Zoppi A, Salvati EA (2006) Favourable mid-term results of the VerSys CT polished cemented femoral stem for total hip arthroplasty. Int Orthop 30:381–386PubMedCrossRef
7.
Zurück zum Zitat Gonzalez Della Valle A, Padgett DE, Salvati E (2005) Preoperative planning for primary total hip arthroplasty. J Am Acad Orthop Surg 13:455–462 Gonzalez Della Valle A, Padgett DE, Salvati E (2005) Preoperative planning for primary total hip arthroplasty. J Am Acad Orthop Surg 13:455–462
8.
Zurück zum Zitat Gonzalez Della Valle A, Slullitel G, Piccaluga F, Salvati EA (2005) The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty. J Arthroplasty 20:51–58PubMedCrossRef Gonzalez Della Valle A, Slullitel G, Piccaluga F, Salvati EA (2005) The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty. J Arthroplasty 20:51–58PubMedCrossRef
9.
Zurück zum Zitat Gonzalez Della Valle A, Su E, Zoppi A, Sculco TP, Salvati EA (2004) Wear and periprosthetic osteolysis in a match-paired study of modular and nonmodular uncemented acetabular cups. J Arthroplasty 19:972–977PubMedCrossRef Gonzalez Della Valle A, Su E, Zoppi A, Sculco TP, Salvati EA (2004) Wear and periprosthetic osteolysis in a match-paired study of modular and nonmodular uncemented acetabular cups. J Arthroplasty 19:972–977PubMedCrossRef
10.
Zurück zum Zitat Gonzalez Della Valle A, Zoppi A, Peterson MG, Salvati EA (2005) A rough surface finish adversely affects the survivorship of a cemented femoral stem. Clin Orthop Relat Res 158–163 Gonzalez Della Valle A, Zoppi A, Peterson MG, Salvati EA (2005) A rough surface finish adversely affects the survivorship of a cemented femoral stem. Clin Orthop Relat Res 158–163
11.
Zurück zum Zitat González Della Valle A, Zoppi A, Peterson MG, Salvati EA (2004) Clinical and radiographic results associated with a modern, cementless modular cup design in total hip arthroplasty. J Bone Jt Surg Am 86-A:1998–2003 González Della Valle A, Zoppi A, Peterson MG, Salvati EA (2004) Clinical and radiographic results associated with a modern, cementless modular cup design in total hip arthroplasty. J Bone Jt Surg Am 86-A:1998–2003
12.
Zurück zum Zitat González Della Valle A, Zoppi A, Peterson MGE, Salvati EA (2004) Age affects the perception of leg length discrepancy in patients with and without a total hip arthroplasty. Hip Int 14:249–253 González Della Valle A, Zoppi A, Peterson MGE, Salvati EA (2004) Age affects the perception of leg length discrepancy in patients with and without a total hip arthroplasty. Hip Int 14:249–253
13.
Zurück zum Zitat Goodman SB, Adler SJ, Fyhrie DP, Schurman DJ (1988) The acetabular teardrop and its relevance to acetabular migration. Clin Orthop 236:199–204PubMed Goodman SB, Adler SJ, Fyhrie DP, Schurman DJ (1988) The acetabular teardrop and its relevance to acetabular migration. Clin Orthop 236:199–204PubMed
14.
Zurück zum Zitat Gorski JM, Schwartz L (1986) A device to measure X-ray magnification in preoperative planning for cementless arthroplasty. Clin Orthop Relat Res 1986:302–306 Gorski JM, Schwartz L (1986) A device to measure X-ray magnification in preoperative planning for cementless arthroplasty. Clin Orthop Relat Res 1986:302–306
15.
Zurück zum Zitat Knight JL, Atwater RD (1992) Preoperative planning for total hip arthroplasty. Quantitating its utility and precision. J Arthroplasty 7 (Suppl):403–409PubMedCrossRef Knight JL, Atwater RD (1992) Preoperative planning for total hip arthroplasty. Quantitating its utility and precision. J Arthroplasty 7 (Suppl):403–409PubMedCrossRef
16.
Zurück zum Zitat Massin P, Schmidt L, Engh CA (1989) Evaluation of cementless acetabular component migration. An experimental study. J Arthroplasty 4:245–251PubMedCrossRef Massin P, Schmidt L, Engh CA (1989) Evaluation of cementless acetabular component migration. An experimental study. J Arthroplasty 4:245–251PubMedCrossRef
17.
Zurück zum Zitat Pellicci PM, Bostrom M, Poss R (1998) Posterior approach to total hip replacement using enhanced posterior soft tissue repair. Clin Orthop 1998:224–228 Pellicci PM, Bostrom M, Poss R (1998) Posterior approach to total hip replacement using enhanced posterior soft tissue repair. Clin Orthop 1998:224–228
18.
Zurück zum Zitat The B, Diercks RL, Stewart RE, van Ooijen PM, van Horn JR (2005) Digital correction of magnification in pelvic x rays for preoperative planning of hip joint replacements: theoretical development and clinical results of a new protocol. Med Phys 32:2580–2589PubMedCrossRef The B, Diercks RL, Stewart RE, van Ooijen PM, van Horn JR (2005) Digital correction of magnification in pelvic x rays for preoperative planning of hip joint replacements: theoretical development and clinical results of a new protocol. Med Phys 32:2580–2589PubMedCrossRef
19.
Zurück zum Zitat The B, Diercks RL, van Ooijen PM, van Horn JR (2005) Comparison of analog and digital preoperative planning in total hip and knee arthroplasties. A prospective study of 173 hips and 65 total knees. Acta Orthop 76:78–84PubMedCrossRef The B, Diercks RL, van Ooijen PM, van Horn JR (2005) Comparison of analog and digital preoperative planning in total hip and knee arthroplasties. A prospective study of 173 hips and 65 total knees. Acta Orthop 76:78–84PubMedCrossRef
20.
Zurück zum Zitat White SP, Shardlow DL (2005) Effect of introduction of digital radiographic techniques on pre-operative templating in orthopaedic practice. Ann R Coll Surg Engl 87:53–54PubMedCrossRef White SP, Shardlow DL (2005) Effect of introduction of digital radiographic techniques on pre-operative templating in orthopaedic practice. Ann R Coll Surg Engl 87:53–54PubMedCrossRef
Metadaten
Titel
The utility and precision of analogue and digital preoperative planning for total hip arthroplasty
verfasst von
Alejandro González Della Valle
Fernando Comba
Nicole Taveras
Eduardo A. Salvati
Publikationsdatum
01.06.2008
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 3/2008
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-006-0317-2

Weitere Artikel der Ausgabe 3/2008

International Orthopaedics 3/2008 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.